ICL7137CPL-3 - 3.5-Digit Dual-Slope ADC | Maxim Integrated
N.º de pieza: ICL7137CPL-3 ✓ ActivoICL7137CPL-3 Descripción general
An analog-to-digital converter is an ADC, a mixed-signal integrated circuit that transforms a continuously varying voltage into a digital value. The ICL7137 family belongs to the display-driver ADC category, combining signal acquisition, conversion, and LED output in one monolithic device. This integration reduces the number of external interface components required for digital panel meters, laboratory instruments, and process-monitoring equipment.
The ICL7137CPL-3 provides a 3.5-digit measurement format, dual-slope conversion, differential input and reference capability, and direct LED display drive. According to the Analog Devices product page, its dual-slope conversion technique automatically rejects interference signals common in industrial environments. Differential input and reference arrangements also support ratiometric measurements of resistance and bridge transducers, where the relationship between the measured quantity and the excitation reference is more important than an absolute voltage reference.
The zero-integrator phase in Maxim's ICL7137 eliminates overrange hangover and hysteresis effects. This behavior helps the meter recover predictably when the input leaves its measurable range, avoiding residual integrator charge from influencing the next conversion. Excluding LED display current, the device supply current is below 200 µA, making it suitable for low-power instrumentation and battery-oriented measurement systems when the display is operated intermittently.
Typical uses include laboratory digital meters, process-control readouts, weighing scales, resistance meters, bridge-based sensors, and industrial panel instruments. The 40-pin PDIP package provides a through-hole format that remains practical for prototypes, educational instruments, and manually assembled industrial control boards. The package is larger than a modern surface-mount ADC, but its accessible pins simplify probing and replacement.
Design the reference, input, integration, and display networks according to the manufacturer datasheet. Pay particular attention to input-source impedance, reference stability, bypass-capacitor placement, and the grounding of the analog and digital return paths. Differential routing helps reject common-mode noise, but the source impedance must remain within the converter's specified limits to preserve accuracy.
This page combines the exact ordering information, 40-pin package identity, functional characteristics, comparison details, and practical design guidance needed to evaluate the ICL7137CPL-3 for a multiplexed LED-display measurement design.
Alternativas directas para ICL7137CPL-3 — mismo encapsulado, compatible pin a pin. Se excluyen las piezas de otro encapsulado que requieren retrabajo de la PCB.
Variantes de esta serie
Modelos de la misma serie compatibles directamente con ICL7137CPL-3 (mismo factor de forma y huella) — difiere en Package Type, Product Type, Supply Current.
ICL7137CPL+3
✅ Sustitución directa📋 Alternativa de referencia (no en el catálogo)
ICL7137CPL+
✅ Sustitución directaConsulte el precio
Ver hoja de datos →ICL7137CPL+
✅ Sustitución directaConsulte el precio
Ver hoja de datos →ICL7137CJL
✅ Sustitución directa📋 Alternativa de referencia (no en el catálogo)
ICL7137CPL-3 Valores máximos y características eléctricas
| Product Type | 3.5-digit dual-slope ADC with LED display driver |
| Resolution / Display Format | 3.5 digits |
| Conversion Technique | Dual-slope |
| Tipo de salida | Multiplexed seven-segment LED display drive |
| Corriente de alimentación | Less than 200 µA, excluding LED display current |
| Input Configuration | True differential input |
| Reference Configuration | True differential reference |
| Overrange Behavior | Zero-integrator phase eliminates overrange hangover and hysteresis effects |
| Temperature Grade | Commercial |
| Terminal Count | 40 terminals |
| Package Type | 40-pin PDIP |
| Package Code | DIP |
| Package Shape | Rectangular |
| Package Body Width | 0.600 in (15.24 mm) |
| Estilo de montaje | Through-hole |
| Carrier Type | Tube |
| Estado del ciclo de vida | Production |
Guía de configuración de pines de ICL7137CPL-3 0.600 in (15.24 mm)
Configuración de pines para ICL7137CPL-3 (encapsulado 0.600 in (15.24 mm)). Este componente analógico presenta pines de entrada, salida y alimentación. Consulte la hoja de datos del fabricante para conocer las configuraciones de los pines de ajuste de offset, compensación y habilitación. Ideal para circuitos de acondicionamiento de señal y amplificadores.
No hay datos detallados de patillaje disponibles para ICL7137CPL-3.
Consulte la hoja de datos para ver la configuración completa de patillas.
Aplicaciones típicas
ICL7137CPL-3 es adecuado para 6 aplicacións: Digital Panel Meter, Digital Resistance Meter, Bridge Transducer Interface, Laboratory Voltage Measurement, Process Monitoring Readout, Battery-Powered Meter.
Digital Panel Meter
The ICL7137CPL-3 is suitable for a standalone digital panel meter because it combines a 3.5-digit dual-slope ADC with direct seven-segment LED drive. The converter measures the analog input, drives the display multiplexing, and operates from a commercial temperature grade in a 40-pin PDIP package. Its dual-slope architecture automatically rejects periodic interference common in industrial environments, while the zero-integrator phase eliminates overrange hangover and hysteresis effects. Place the input, reference, integration, and bypass networks according to the manufacturer application circuit, and route the display-current return separately from the sensitive analog return where the layout guidance permits it.
Recomendado
Digital Resistance Meter
A resistance-measurement instrument can use the ICL7137CPL-3's differential input and reference arrangement to measure an unknown resistance against a known reference. The 3.5-digit display format provides adequate resolution for many bench-top and service instruments, while dual-slope conversion rejects periodic noise present on industrial test benches. The ICL7137 family is specifically identified as useful for ratiometric resistance measurements, where the measured value is derived from the ratio of input and reference signals. Component tolerances, reference stability, input leakage, and source impedance must be evaluated together to achieve the required accuracy.
Recomendado
Bridge Transducer Interface
The ICL7137CPL-3 fits bridge-based measurement systems because its true differential input and reference structure supports ratiometric sensing. A strain-gauge, pressure, or load-cell bridge can be excited by a reference source while the converter determines the bridge imbalance relative to that excitation. This arrangement reduces sensitivity to supply drift compared with an absolute-reference measurement. Dual-slope conversion rejects periodic interference, and the zero-integrator behavior improves recovery after an overrange condition. The exact bridge excitation, gain, input impedance, and compensation network should follow the ICL7137 datasheet and application guidance.
Recomendado
Laboratory Voltage Measurement
The ICL7137CPL-3 provides the core conversion and display function for a laboratory voltage meter while retaining a familiar through-hole architecture for educational and service equipment. Its 3.5-digit result format is appropriate for routine measurements that do not require higher resolution, and the multiplexed LED output avoids a separate display-driver IC. The dual-slope conversion method rejects periodic interference, while differential input and reference connections can reduce sensitivity to common-mode voltage. For bench instruments, calibrate gain and offset carefully and observe the source-impedance limits specified by the manufacturer.
Recomendado
Process Monitoring Readout
The ICL7137CPL-3 is applicable to a local process-monitoring readout where the measured variable must be presented directly to an operator. Its industrial-oriented dual-slope conversion rejects periodic interference, and differential sensing helps control errors caused by common ground potentials within a control panel. The integrated LED drive reduces component count and assembly complexity compared with a separated ADC and display interface. Commercial temperature grading suits many indoor industrial environments, although the enclosure temperature, supply tolerance, isolation strategy, and protection network must be checked independently. Validate the complete sensor loop against the required accuracy and update rate.
Recomendado
Battery-Powered Meter
The ICL7137CPL-3 can serve as the measurement core of a battery-powered meter when display duty cycle is controlled. The ICL7137 family's supply current is below 200 µA excluding LED display current, allowing the converter to remain suitable for low-power operation. Actual battery demand will usually be dominated by illumination of the seven-segment display, so designers should evaluate blanking, duty cycle, and the display's drive current. The commercial-grade 40-pin PDIP package is practical for hand-assembled prototypes and low- to moderate-volume instruments, while the manual assembly requirement should be considered for highly automated production.
Recomendado
Resumen de productos recomendados
Datos de referencia de ingeniería para ICL7137CPL-3 — comparación, orientación de diseño e información de cumplimiento.
Guía de selección
Comparación con alternativas
| Parámetro | Este producto | ICL7137CPL+3 | ICL7137CPL+ | ICL7137CPL | ICL7137CJL |
|---|---|---|---|---|---|
| Package | 40-pin PDIP | 40-pin PDIP | 40-pin PDIP | 40-pin PDIP | 40-pin PDIP |
| Brand | Maxim Integrated | Maxim Integrated | Maxim Integrated | Maxim Integrated | Maxim Integrated |
| Converter Type | Dual-slope ADC | Dual-slope ADC | Dual-slope ADC | Dual-slope ADC | Dual-slope ADC |
| Display Resolution | 3.5 digits | 3.5 digits | 3.5 digits | 3.5 digits | 3.5 digits |
| Mounting Style | Through-hole | Through-hole | Through-hole | Through-hole | Through-hole |
Diferenciadores clave
- Combines conversion and LED display drive in one device (frente a ICL7107CPLZ)
- Zero-integrator overrange recovery behavior (frente a ICL7137CPL)
- Commercial-grade ordering option (frente a ICL7137CJL)
Notas de diseño
Route the input, reference, integration, and bypass networks as short analog paths, and keep the seven-segment display-current returns from sharing sensitive return-current paths with the converter. Use a single low-impedance ground strategy consistent with the manufacturer's application circuit rather than assuming analog and digital returns can be separated arbitrarily. A 40-pin PDIP provides generous routing space, but lead inductance and long prototype wiring can still degrade measurement stability.
Do not treat ICL7137CPL-3, ICL7137CPL+3, ICL7137CPL+, and ICL7137CPL as automatically equivalent ordering codes. Confirm the complete manufacturer ordering table, temperature grade, lead finish, and production status before substitution. Likewise, ICL7137CJL is documented as a ceramic-temperature-grade family variant, so it should not replace a commercial-grade requirement without checking its numerical environmental limits and qualification details.
Estimated: converter supply consumption below 200 µA is specified excluding LED display current, so the total operating demand depends on digit count, segment illumination, and duty cycle. For battery operation, calculate average display load using the selected segment currents and compare the resulting peak supply requirement with the source capability. Add local bypass capacitance and provide adequate light-drive headroom rather than sizing the supply only from the converter's quiescent current.
Preserve the manufacturer's specified source-impedance limits because dual-slope accuracy depends on the input network charging the internal integration node accurately. A differential input arrangement is not automatically immune to unequal source impedances, so use closely matched components when both signal and reference paths require symmetry. Check input protection leakage and reference stability if the source impedance is high, since both can shift the displayed result.
Información de cumplimiento
No definitive RoHS, REACH, lead-free, halogen-free, or conflict-minerals statement is present in the product information used for this page. AEC-Q100 is not applicable because the ICL7137CPL-3 is identified as a commercial-grade instrumentation ADC rather than an automotive-qualified device.