ICL7129ACPL+ - 4.5-Digit Low-Noise LCD ADC | Maxim Integrated
N.º de pieza: ICL7129ACPL+ ✓ ActivoICL7129ACPL+ Descripción general
Alternativas directas para ICL7129ACPL+ — mismo encapsulado, compatible pin a pin. Se excluyen las piezas de otro encapsulado que requieren retrabajo de la PCB.
Variantes de esta serie
Modelos de la misma serie compatibles directamente con ICL7129ACPL+ (mismo factor de forma y huella) — difiere en Converter Type, Display Output, Mounting Type, Resolution.
ICL7129CPL
✅ Sustitución directaConsulte el precio
Ver hoja de datos →ICL7129ACPL+2
✅ Sustitución directa📋 Alternativa de referencia (no en el catálogo)
TC7129CKW
✅ Sustitución directa📋 Alternativa de referencia (no en el catálogo)
ICL7117CPL+
✅ Sustitución directaConsulte el precio
Ver hoja de datos →ICL7106CPLZ
✅ Sustitución directa📋 Alternativa de referencia (no en el catálogo)
ICL7129ACPL+ Valores máximos y características eléctricas
| Converter Type | 4.5-digit single-chip successive-integration ADC |
| Display Output | Multiplexed LCD drivers |
| Input Configuration | High-impedance differential inputs |
| Resolución | 4.5 digits; +/-19,999 counts |
| Conversion Technology | Successive integration |
| Polarity Detection | Automatic polarity detection |
| Ratiometric Operation | True ratiometric operation |
| Input Noise | 3 uV peak-to-peak for ICL7129A |
| Range Changing | 10:1 range-changing input |
| Encapsulado | 40-pin PDIP |
| Tipo de montaje | Through-hole DIP |
Guía de configuración de pines de ICL7129ACPL+ 40-pin pdip
Configuración de pines para ICL7129ACPL+ (encapsulado 40-pin pdip). Este componente analógico presenta pines de entrada, salida y alimentación. Consulte la hoja de datos del fabricante para conocer las configuraciones de los pines de ajuste de offset, compensación y habilitación. Ideal para circuitos de acondicionamiento de señal y amplificadores.
No hay datos detallados de patillaje disponibles para ICL7129ACPL+.
Consulte la hoja de datos para ver la configuración completa de patillas.
Aplicaciones típicas
ICL7129ACPL+ es adecuado para 6 aplicacións: Digital Voltmeter, Digital Panel Meter, Laboratory Measurement Instrument, Process Control Monitor, Weighing Scale Display, Temperature Measurement Instrument.
Digital Voltmeter
The ICL7129ACPL+ is suited to a precision digital voltmeter because it combines a 4.5-digit ADC, high-impedance differential inputs, true ratiometric operation, and automatic polarity detection. The instrument can use the converter's multiplexed LCD drivers to present the measured voltage directly without a separate display-driver IC. Input conditioning should include protection, filtering, and a stable reference arrangement selected for the intended voltage range. The 40-pin PDIP format is convenient for laboratory prototypes, educational instruments, and repair-oriented panel-meter designs where through-hole construction and direct LCD support are priorities.
Recomendado
Digital Panel Meter
A digital panel meter can use the ICL7129ACPL+ to convert a conditioned sensor or process signal into a 4.5-digit LCD reading. Automatic polarity detection simplifies bipolar measurements, while the 10:1 range-changing input supports designs that need more than one measurement scale. The integrated multiplexed LCD drivers reduce the number of external interface components and help create a compact instrument front panel. Panel-meter engineers should verify the LCD segment configuration, reference voltage, input common-mode limits, and timing requirements against the manufacturer datasheet before finalizing the PCB.
Recomendado
Laboratory Measurement Instrument
The low-noise 4.5-digit conversion and high-impedance differential input arrangement make the ICL7129ACPL+ useful in laboratory instruments that display slow or medium-speed measurements with high resolution. The ICL7129A family's listed 3 uV peak-to-peak input noise supports precision measurement designs, although the complete signal chain must remain quiet. A practical implementation places the converter close to the input network, uses careful grounding, and selects a stable reference. The multiplexed LCD output provides a readable result without requiring a separate display interface in the basic measurement instrument.
Recomendado
Process Control Monitor
The ICL7129ACPL+ can serve as the measurement and display front end of a process-control monitor when the input is conditioned into the converter's supported range. Its automatic polarity detection and true ratiometric operation are useful for signals derived from sensors or bridge-like excitations, while the 4.5-digit format provides more display resolution than a 3.5-digit meter. For industrial deployment, the design must protect the analog input from transients and maintain a low-noise reference and ground arrangement. The PDIP package is appropriate for through-hole industrial control boards that require serviceability and visual operator feedback.
Recomendado
Weighing Scale Display
A weighing-scale display can use the ICL7129ACPL+ when the load-cell or transducer signal is amplified, filtered, and referenced with sufficient stability. The 4.5-digit resolution provides 19,999 count positions, while ratiometric operation can help maintain scale accuracy when the excitation and measurement paths share a controlled reference relationship. The LCD drivers are appropriate for a compact operator display. Calibration, input offset, gain trimming, excitation noise, and mechanical vibration remain system-level concerns; the converter should be positioned away from high-current switching paths to avoid contaminating the measurement.
Recomendado
Temperature Measurement Instrument
The ICL7129ACPL+ is applicable to temperature measurement instruments that use a linearized sensor signal and a local LCD. The 4.5-digit display resolution can show fractional temperature information, and the high-impedance input supports the external signal-conditioning network required by thermocouple or RTD front ends. Input bias, common-mode behavior, and leakage from the protection network should be checked because they can create errors in high-impedance temperature sensors. A stable reference and carefully routed ground plane are essential, while the multiplexed LCD output keeps the display interface compact.
Recomendado
Resumen de productos recomendados
Datos de referencia de ingeniería para ICL7129ACPL+ — comparación, orientación de diseño e información de cumplimiento.
Guía de selección
Comparación con alternativas
| Parámetro | Este producto | ICL7129CPL | ICL7129ACPL+2 | TC7129CKW | ICL7117CPL+ | ICL7106CPLZ |
|---|---|---|---|---|---|---|
| Package | 40-pin PDIP | 40-pin PDIP | 40-pin PDIP | 40-pin PDIP | 40-pin PDIP | 40-pin PDIP |
| Brand | Maxim Integrated | Maxim Integrated | Maxim Integrated | Texas Instruments | Maxim Integrated | Maxim Integrated |
| Conversion Method | Successive integration | Successive integration | Successive integration | Successive integration | Dual-slope conversion | Dual-slope conversion |
Diferenciadores clave
- Higher display resolution than the 3.5-digit ICL7117CPL+ (frente a ICL7117CPL+)
- Integrated multiplexed LCD drive (frente a ICL7106CPLZ)
- Automatic polarity detection (frente a TC7129CKW)
Notas de diseño
Place the ICL7129ACPL+ close to the analog input and reference network, and route the LCD output traces away from sensitive measurement nodes. The 40-pin PDIP footprint provides generous mechanical spacing, but the analog input pins still require short traces and a continuous ground plane. Confirm the manufacturer pin-description table before assigning LCD segment, reference, supply, and analog signal connections.
Use a low-noise reference and bypass arrangement, and filter the input signal with values appropriate to the required response time. The device uses successive integration, so system timing and input settling must be coordinated with the measurement range. Avoid sharing high-current return paths between the sensor, reference, and display subsystem, since ground movement can appear directly as measurement error.
Do not assume that every 40-pin display-driver ADC is interchangeable. The ICL7129ACPL+ requires the correct 4.5-digit LCD segment arrangement, reference configuration, polarity behavior, and timing sequence. Before using ICL7117CPL+, ICL7106CPLZ, or another listed candidate, compare every pin function and the display timing diagrams in the manufacturer documentation.
Información de cumplimiento
The trailing plus suffix is associated with Maxim Integrated lead-free ordering, but no explicit RoHS, REACH, halogen-free, or conflict-minerals statement was identified. Automotive qualification is not stated.