INA145UA/2K5 - Programmable Gain Difference Amplifier | TI
N.º de pieza: INA145UA/2K5 ✓ ActivoINA145UA/2K5 Descripción general
A programmable-gain difference amplifier is a specialized operational-amplifier circuit that measures the voltage between two input terminals rather than amplifying a signal relative to ground. In the signal-chain hierarchy, it belongs to the differential amplifier family, combines with instrumentation-amplifier and operational-amplifier techniques, and ultimately supports analog front-end design. This distinction makes the INA145 particularly suitable for sensing differential sensor outputs while rejecting signals common to both inputs.
The Texas Instruments INA145 family provides programmable gain so the same physical circuit can accommodate signals over a broad range. The listed specifications include a slew rate of 0.45 V/µs, a 500 kHz bandwidth figure, a 200 µV offset-voltage specification and a 50 nA input-bias-current figure. At gain G = 1, the supplied specification excerpt identifies a 10 kΩ load connected to ground and the reference pin at 2.5 V. These values illustrate the importance of selecting the correct gain and reference configuration for the intended signal path.
The device can operate from a single +5 V supply under the conditions identified in the manufacturer specification excerpt. Its total input-bias-current condition includes a 10 kΩ feedback resistor associated with amplifier A2, while gain is defined as 1 V/V for the conditions noted. The electrical design therefore combines high input impedance with selectable gain, allowing small differential signals to be amplified without first converting them into a single-ended signal. The reference and feedback connections are central to accurate system-level gain and output-offset control.
Typical applications include current-sense and shunt monitoring, bridge-sensor signal conditioning, differential measurement front ends, instrumentation interfaces and industrial analog systems. In a shunt monitor, the amplifier can amplify the voltage across a low-value sense resistor while rejecting the common-mode voltage present across that resistor. In a bridge sensor, it supports measurement of a small differential output generated around a larger common-mode voltage. Its 500 kHz bandwidth figure also makes it relevant to moderate-speed sensing rather than only static temperature or pressure measurements.
Designers should preserve the input, output and reference pin assignments shown in the manufacturer pin-description table and should avoid treating the reference pin as an arbitrary external bias point. Differential input routing should be compact and symmetric to minimize conversion of common-mode noise into differential error. Supply bypassing, resistor tolerance and feedback-network stability directly affect accuracy, so the recommended application circuit and component values should be followed rather than substituting generic values without checking gain, bandwidth and output-swing requirements.
This page combines the exact ordering information, operating limits and application guidance associated with INA145UA/2K5 with same-package replacement options and practical design notes. It also highlights the 2,500-piece reel format, the distinction between the standard electrical device and package-ordering variants, and the measurement conditions engineers must preserve when comparing specifications across different gain settings.
Alternativas directas para INA145UA/2K5 — mismo encapsulado, compatible pin a pin. Se excluyen las piezas de otro encapsulado que requieren retrabajo de la PCB.
Variantes de esta serie
Modelos de la misma serie compatibles directamente con INA145UA/2K5 (mismo factor de forma y huella) — difiere en Offset Voltage, Package.
INA145UA/2K5E4
✅ Sustitución directa📋 Alternativa de referencia (no en el catálogo)
INA145UA
✅ Sustitución directaConsulte el precio
Ver hoja de datos →INA145UA/2K5.A
✅ Sustitución directa📋 Alternativa de referencia (no en el catálogo)
INA145UA/2K5 Valores máximos y características eléctricas
| Product Type | Programmable gain difference amplifier |
| Number of Circuits | 1 circuit |
| Supply Voltage Range, Dual | ±2.25 V to ±18 V |
| Typical Dual Supply Voltages | ±3 V, ±5 V, ±9 V, ±12 V and ±15 V |
| Single-Supply Test Condition | +5 V |
| Gain | Programmable; 1 V/V under specified gain = 1 conditions |
| Slew Rate | 0.45 V/µs |
| Bandwidth | 500 kHz |
| Offset Voltage | 200 µV |
| Input Bias Current | 50 nA |
| Rango de temperatura de funcionamiento | -40 °C to +85 °C |
| Reference Test Voltage | 2.5 V at gain = 1 |
| Load Resistance | 10 kΩ to ground under specified test conditions |
| Feedback Resistance | 10 kΩ associated with A2 under specified test conditions |
| Encapsulado | 8-pin SOIC (D) |
| Tipo de montaje | Surface mount |
| Shipping Format | Tape and reel, 2,500 devices per reel |
Guía de configuración de pines de INA145UA/2K5 8-pin soic (d)
Configuración de pines para INA145UA/2K5 (encapsulado 8-pin soic (d)). Este componente analógico presenta pines de entrada, salida y alimentación. Consulte la hoja de datos del fabricante para conocer las configuraciones de los pines de ajuste de offset, compensación y habilitación. Ideal para circuitos de acondicionamiento de señal y amplificadores.
No hay datos detallados de patillaje disponibles para INA145UA/2K5.
Consulte la hoja de datos para ver la configuración completa de patillas.
Aplicaciones típicas
INA145UA/2K5 es adecuado para 6 aplicacións: Shunt-Based Current Sensing, Bridge Sensor Signal Conditioning, Industrial Differential Voltage Monitoring, Instrumentation and Sensor Interfaces, Portable Sensor and Wearable Electronics, Communication and RF Control Loops.
Shunt-Based Current Sensing
The INA145UA/2K5 is appropriate for measuring the small differential voltage produced across a low-value current-shunt resistor. Its programmable-gain architecture can amplify the shunt voltage while rejecting the common-mode voltage developed across the resistive element, which helps avoid saturating the measurement chain. The listed 0.45 V/µs slew rate and 500 kHz bandwidth support moderate-speed current changes, while the 200 µV offset specification is important when working with low-amplitude shunt outputs. Select a gain that keeps the output within the amplifier's usable swing at maximum load current, and route the sense traces as a compact differential pair to minimize conversion of common-mode noise into measurement error.
Recomendado
Bridge Sensor Signal Conditioning
The INA145UA/2K5 fits resistive bridge sensing where the useful signal is the small voltage difference between two sensor nodes. Its difference-amplifier configuration rejects the larger common-mode component and allows gain to be selected for the expected bridge output. With a 500 kHz bandwidth figure, the device can accommodate modest mechanical or industrial dynamics without introducing the switching noise associated with a continuously converting pulse-width-modulated front end. The 50 nA input-bias-current value and 200 µV offset specification should be checked against the sensor impedance and resolution requirements. Keep the differential input routes symmetrical and follow the manufacturer reference configuration to preserve common-mode rejection and establish the intended output offset.
Recomendado
Industrial Differential Voltage Monitoring
The INA145UA/2K5 can condition a differential voltage in industrial monitoring equipment where the measured quantity is embedded within a larger common-mode range. Its ±2.25 V to ±18 V dual-supply capability provides flexibility for powered industrial systems, while the programmable gain lets one analog front end serve several input ranges. The specified -40 °C to +85 °C operating range covers many commercial and industrial environments. Designers should verify input and output limits against the actual rail voltage, use a stable reference arrangement, and account for the 0.45 V/µs slew rate when large transient inputs are possible. Differential routing and careful grounding are essential because any mismatch introduced after the amplifier cannot be recovered by downstream digitization.
Recomendado
Instrumentation and Sensor Interfaces
The INA145UA/2K5 serves as the analog front end in instrumentation interfaces that must recover a small differential sensor signal without grounding the sensor to the measurement system. Its high input impedance reduces loading, while the dedicated difference-amplifier topology improves rejection of common-mode voltage. Programmable gain supports scaling for several transducer sensitivities, and the listed 500 kHz bandwidth covers moderate-speed sensor dynamics. For instrumentation systems, the reference configuration determines output offset, so its tolerance and noise should be included in the complete error budget. Keep the two input nets together and away from switching nodes to preserve differential-signal integrity. The amplifier is best suited to precision and moderate-bandwidth interfaces rather than wideband video or very fast communications channels.
Recomendado
Portable Sensor and Wearable Electronics
The INA145UA/2K5 can amplify differential sensor outputs in compact portable equipment where battery efficiency, board area and usable signal bandwidth are important. The programmable gain allows a single amplifier selection to cover a wider input range than a fixed-gain device, reducing the need for multiple analog paths. Its 8-pin SOIC package simplifies routing compared with larger instrumentation-amplifier packages, and the single +5 V test condition demonstrates operation from a common system rail. The design must still account for supply headroom, output swing and the 0.45 V/µs slew rate. Use the lowest gain that provides the required signal-to-noise ratio, and verify that common-mode input limits are maintained during battery charging or sensor transitions.
Recomendado
Communication and RF Control Loops
The INA145UA/2K5 can support low-level differential monitoring in communication equipment, such as feedback measurement, detector conditioning or control-loop signal observation. Its 500 kHz bandwidth and 0.45 V/µs slew rate provide enough response for moderate-bandwidth supervisory loops, while programmable gain helps normalize small detected differential signals. This is not a substitute for a high-speed RF mixer or a multi-gigabit digital receiver. When the input is derived from an RF front end, engineers should verify common-mode range, input protection requirements and bandwidth behavior at the selected gain. Differential routing with symmetrical geometry and controlled return paths helps preserve the benefit of the difference amplifier, especially when the measured signal is small relative to the surrounding common-mode voltage.
Recomendado
Resumen de productos recomendados
Datos de referencia de ingeniería para INA145UA/2K5 — comparación, orientación de diseño e información de cumplimiento.
Guía de selección
Comparación con alternativas
| Parámetro | Este producto | INA145UA/2K5E4 | INA145UA | INA145UA/2K5.A |
|---|---|---|---|---|
| Package | 8-pin SOIC (D) | 8-pin SOIC (D) | 8-pin SOIC (D) | 8-pin SOIC (D) |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Product Type | Programmable gain difference amplifier | Programmable gain difference amplifier | Programmable gain difference amplifier | Programmable gain difference amplifier |
| Ordering Format | /2K5 tape-and-reel, 2,500 devices per reel | Includes /2K5 base designation and E4 suffix | No /2K5 reel designation | /2K5 base designation with .A suffix |
Diferenciadores clave
- Dedicated single-channel programmable-gain difference-amplifier architecture (frente a INA145UA)
- Factory-defined 2,500-piece tape-and-reel configuration (frente a INA145UA)
- Same 8-pin SOIC footprint within the documented INA145 ordering family (frente a INA145UA/2K5E4)
Notas de diseño
Route VIN+ and VIN- as a compact, symmetrical differential pair with continuous ground reference. Keep the pair away from switching nodes, relay contacts and high-current return paths because unequal coupling converts common-mode energy into differential error. Place associated feedback and reference components close to the relevant amplifier pins, and follow the manufacturer pin-description table when making PCB net assignments.
Do not assume that matching packages automatically make every INA145 ordering code equivalent. The /2K5 code denotes a 2,500-piece tape-and-reel shipment, while additional suffixes such as E4 and .A can carry ordering, grade or traceability semantics. For a production drop-in decision, compare the complete orderable MPN, pin assignments, operating-temperature grade, reel quantity, quality level and lifecycle status against the required BOM item.
Choose the programmed gain together with the required signal bandwidth instead of maximizing gain in isolation. The INA145UA/2K5 is listed at 500 kHz bandwidth and 0.45 V/µs slew rate, so a large gain reduction in bandwidth or a fast large-signal transition can limit signal fidelity. Use the manufacturer gain-setting and reference configuration, verify output swing at worst-case load, and place input and feedback components close to the device to minimize parasitic feedback.
Información de cumplimiento
No explicit RoHS, REACH, AEC-Q100, lead-free, halogen-free or conflict-minerals declaration was identified for the exact ordering code. The manufacturer product page and datasheet should be checked for current environmental and quality documentation.