MAX232MLP/883B - Dual RS-232 Transceiver | Maxim Integrated
N.º de pieza: MAX232MLP/883B ✓ ActivoMAX232MLP/883B Descripción general
An RS-232 transceiver is an interface IC that converts logic-level signals into RS-232 differential voltage levels and converts incoming RS-232 signals back into logic-compatible levels. The MAX232 family belongs to the broader line-driver and line-receiver hierarchy, connecting modern digital control systems with RS-232 equipment through the EIA/TIA-232E and V.28/V.24 interface specifications.
The MAX232MLP/883B provides two transmit channels and two receive channels, allowing a complete full-duplex RS-232 port to be implemented with one integrated circuit. Its 120 kb/s maximum data rate is suitable for configuration ports, diagnostic consoles, industrial control links, and service equipment. The single 5 V supply also simplifies system power design compared with older RS-232 implementations requiring positive and negative voltage rails.
The MAX232 family uses charge-pump circuitry to generate the positive and negative voltages required by RS-232 line levels from the 5 V supply. Charge-pump capacitors must be connected exactly as shown in the manufacturer datasheet, with suitable ceramic capacitance and effective loop layout. A receive and transmit path can operate simultaneously, supporting full-duplex communication through the integrated dual-channel arrangement.
Typical applications include industrial serial adapters, instrumentation interfaces, embedded-service ports, legacy peripheral connections, and data-acquisition equipment. The military-temperature ordering variant is relevant when environmental requirements exceed the standard commercial temperature range. Its 20-terminal ceramic package also differs mechanically from the 16-pin plastic-DIP and narrow-SOIC options offered elsewhere in the MAX232 family.
Board design should preserve the charge-pump connection paths and provide appropriate bypass capacitance close to the supply pins. Keep RS-232 signal routing away from sensitive analog or high-speed digital traces, use the specified external capacitors, and observe the absolute maximum ratings for supply and signal voltages. The interface is intended for RS-232 levels, not directly for TTL, CMOS, RS-485, or differential Ethernet signals.
This page combines the manufacturer product information, package characteristics, interface functions, and verified ordering information into an engineering-focused guide. It also identifies practical applications, same-footprint family alternatives, and design considerations that help shorten component selection and PCB implementation time.
Alternativas directas para MAX232MLP/883B — mismo encapsulado, compatible pin a pin. Se excluyen las piezas de otro encapsulado que requieren retrabajo de la PCB.
MAX232MLP
✅ Sustitución directa📋 Alternativa de referencia (no en el catálogo)
MAX232MLP/883
✅ Sustitución directa📋 Alternativa de referencia (no en el catálogo)
MAX232MLP/883B Especificaciones
| Product Type | RS-232 line transceiver |
| Transmitter Channels | 2 channels |
| Receiver Channels | 2 channels |
| Nominal Supply Voltage | 5 V |
| Maximum Data Rate | 120 kb/s |
| Interface Standard | EIA/TIA-232E and V.28/V.24 |
| Duplex Mode | Full duplex |
| Package Type | 20-LCC, no-lead |
| Package Dimensions | 8.9 mm x 8.9 mm |
| Package Code | QCCN |
| Package Shape | Square |
| Terminal Count | 20 terminals |
| Estilo de montaje | No-lead surface mount |
| Temperature Grade | Military |
| ESD HBM Rating | 2 kV |
Guía de configuración de pines de MAX232MLP/883B square
Configuración de pines para MAX232MLP/883B (encapsulado square). La numeración de pines, las funciones y los diagramas de conexión se definen en la hoja de datos del fabricante. Consúltela para conocer el footprint exacto y las directrices de soldadura.
No hay datos detallados de patillaje disponibles para MAX232MLP/883B.
Consulte la hoja de datos para ver la configuración completa de patillas.
Aplicaciones típicas
MAX232MLP/883B es adecuado para 6 aplicacións: Industrial Diagnostic Console, Data-Acquisition Equipment, Legacy Peripheral Interface, Instrumentation Service Port, Embedded Configuration Interface, Military-Grade Control Interface.
Industrial Diagnostic Console
The MAX232MLP/883B fits an industrial diagnostic console that must exchange RS-232 diagnostic data with a controller or service computer. Its two transmitters and two receivers support full-duplex operation, while the 120 kb/s maximum rate is more than adequate for command responses, configuration logs, and status polling. A single 5 V supply simplifies the interface supply rail. Place the transceiver between the controller logic and the isolated or protected RS-232 connector, following the manufacturer charge-pump capacitor values and keeping the connector-side return path away from sensitive analog circuitry.
Recomendado
Data-Acquisition Equipment
The MAX232MLP/883B is appropriate for laboratory and industrial data-acquisition equipment that must communicate over an RS-232 control port. The two independent transmit and receive channels can support separate command and telemetry links, and the 120 kb/s rate is suitable for moderate-volume sensor data and configuration information. Operating from 5 V avoids requiring separate positive and negative RS-232 rails. Use the device near the connector or cable entry point so unbalanced RS-232 signals do not cross sensitive measurement circuitry, and observe the specified charge-pump capacitor layout.
Recomendado
Legacy Peripheral Interface
The MAX232MLP/883B provides a practical bridge between modern digital logic and a legacy RS-232 peripheral. Two transmitters and two receivers allow more than one directional channel to share one interface IC, while full-duplex operation permits simultaneous command transmission and status reception. Its 120 kb/s limit is appropriate for many printers, scales, programmable instruments, and service interfaces. Confirm logic-level compatibility with the host controller, connect the appropriate RS-232 signal and ground conductors at the equipment boundary, and route the cable-side nets away from clocks, sensors, and high-impedance analog inputs.
Recomendado
Instrumentation Service Port
The MAX232MLP/883B is well suited to an instrumentation service port because it combines two full-duplex RS-232 channels with a maximum 120 kb/s data rate in a single 5 V-powered device. This allows a product to expose command, log, or calibration communication without allocating a separate transceiver for each direction. The 20-terminal no-lead LCC package supports dense ceramic or hybrid assemblies where a 16-pin DIP would be too large. Validate the environmental rating and /883B ordering requirements for the target system, and provide the external charge-pump capacitors with short, compact traces.
Recomendado
Embedded Configuration Interface
The MAX232MLP/883B can provide a compact configuration interface for embedded industrial equipment that must be programmed or monitored through a service connection. The integrated dual transmitter and dual receiver arrangement supports full-duplex exchanges without separate level-conversion ICs for each signal direction. Its 120 kb/s maximum rate is suitable for firmware-loading control messages, device identification, and configuration transfers rather than bulk file traffic. Use a single 5 V supply, place bypass and charge-pump capacitors close to their associated pins, and provide the appropriate logic thresholds for the controller connected to the transceiver.
Recomendado
Military-Grade Control Interface
The MAX232MLP/883B is appropriate for a military-grade control interface when the system requires the exact /883B ordering variant and its associated environmental and qualification specifications. The device supplies two RS-232 transmitters and two receivers from a 5 V source, supporting full-duplex control and status traffic up to 120 kb/s. Its 20-terminal QCCN ceramic LCC package supports compact, ruggedized assemblies where a plastic DIP or SOIC may be unsuitable. Before release, compare the complete ordering table, temperature limits, package tolerances, and test requirements against the system specification.
Recomendado
Resumen de productos recomendados
Datos de referencia de ingeniería para MAX232MLP/883B — comparación, orientación de diseño e información de cumplimiento.
Guía de selección
Comparación con alternativas
| Parámetro | Este producto | MAX232MLP | MAX232MLP/883 |
|---|---|---|---|
| Brand | Maxim Integrated | Maxim Integrated | Maxim Integrated |
| Package | 20-LCC | 20-LCC - same | 20-LCC - same |
| Transmitter Channels | 2 | 2 | 2 |
| Receiver Channels | 2 | 2 | 2 |
| Nominal Supply Voltage | 5 V | 5 V | 5 V |
| Maximum Data Rate | 120 kb/s | 120 kb/s | 120 kb/s |
| Duplex Mode | Full duplex | Full duplex | Full duplex |
| Ordering Variant | MAX232MLP/883B | MAX232MLP | MAX232MLP/883 |
Diferenciadores clave
- Exact /883B military ordering variant (frente a MAX232MLP)
- Dual full-duplex RS-232 channels in one package (frente a MAX232MLP/883)
- No-lead 20-terminal ceramic package (frente a MAX232MLP/883)
Notas de diseño
Place the MAX232MLP/883B charge-pump capacitors exactly as shown in the Maxim Integrated MAX232 datasheet and keep each capacitor's associated signal trace short. The no-lead 20-LCC footprint should follow the manufacturer package drawing, including terminal length, width, and exposed geometry. Confirm that the board accommodates the 8.9 mm by 8.9 mm ceramic package and that no-lead components are placed only where the assembly process supports their soldering profile.
Route RS-232 connector-side signals directly to the MAX232MLP/883B and keep them separated from clocks, ADC inputs, references, and other high-impedance analog nodes. The RS-232 interface is unbalanced and can pick up noise when routed across the board. Provide a continuous return path for each interface and use the connector-side ground reference according to the equipment architecture. Avoid long stubs and unnecessary test-point branches on charge-pump and line-driver nets.
Decouple the 5 V supply close to the transceiver with the capacitance specified by the manufacturer and account for the device's supply-current requirement in the upstream regulator design. Check every connected signal against the MAX232 absolute-maximum ratings, including off-state and powered-state input voltages. The internal charge pump generates bipolar RS-232 voltage from the single 5 V supply, so the external capacitor values and ESR characteristics remain part of the interface performance.
Do not treat RS-232 logic levels as direct TTL or CMOS levels, and do not connect the MAX232MLP/883B to an RS-485 bus. Verify the full ordering code, temperature grade, package dimensions, and qualification requirements before replacing MAX232MLP/883B with a related MAX232 suffix. A shared family name does not remove the need to compare pin assignments, electrical limits, ceramic-package tolerances, and procurement specifications.
Información de cumplimiento
The manufacturer material identifies the MAX232 family and its EIA/TIA-232E and V.28/V.24 applications. Specific RoHS, REACH, AEC-Q100, lead-free, halogen-free, and conflict-minerals statements for the exact MAX232MLP/883B ordering suffix require confirmation from the manufacturer documentation.