MAX3381ECUP+T - 250kbps RS-232 Transceiver | Analog Devices
N.º de pieza: MAX3381ECUP+T ✓ ActivoMAX3381ECUP+T Descripción general
An RS-232 transceiver is an interface IC that converts logic-level signals into RS-232 line levels and converts received RS-232 signals back into digital logic levels. In the broader electronics hierarchy, an RS-232 transceiver belongs to interface ICs and line-driver and receiver devices, where it protects a host controller from the voltage range and electrostatic-discharge exposure of a serial connection.
The MAX3381E family supports two transmit channels and two receive channels, allowing full-duplex communication through one package. Its 2.35V minimum supply voltage supports modern low-voltage embedded systems, while the 5.5V maximum accommodates conventional 5V equipment. The 250kbps maximum data rate is suitable for industrial control links, point-of-sale equipment, data acquisition, and service interfaces.
Integrated charge-pump circuitry generates the bipolar voltage required to transmit RS-232-compatible levels from a single low-voltage supply. According to the manufacturer datasheet, enhanced electrostatic-discharge protection is provided on both the TTL and RS-232 sides, covering the 15kV ESD-protected I/O and logic pins identified for this device.
Typical uses include industrial serial controllers, programmable-logic or microcontroller UART links, instrumentation, and embedded control systems. The two transmitters can support separate outbound channels, while the two receivers allow simultaneous inbound monitoring or redundant communication paths when the connected system requires them.
PCB design should provide a solid ground plane, place charge-pump and interface components close to the device, and preserve adequate clearances around connected RS-232 lines. Decoupling capacitors should be placed directly beside the supply pins. The 20-TSSOP footprint is compact, but its narrow lead pitch requires careful inspection and reliable assembly processes.
This product page combines operating limits, interface characteristics, application guidance, package details, and same-family drop-in alternatives to support component selection and PCB design before an RS-232 interface is committed to production.
Alternativas directas para MAX3381ECUP+T — mismo encapsulado, compatible pin a pin. Se excluyen las piezas de otro encapsulado que requieren retrabajo de la PCB.
Variantes de esta serie
Modelos de la misma serie compatibles directamente con MAX3381ECUP+T (mismo factor de forma y huella) — difiere en Interface Standard, Package, Supply Voltage Range.
MAX3380ECUP+T
✅ Sustitución directa ⚠️ Especificaciones sin verificarConsulte el precio
Ver hoja de datos →MAX3381CUP+T
✅ Sustitución directa ⚠️ Especificaciones sin verificar📋 Alternativa de referencia (no en el catálogo)
MAX3380CUP+T
✅ Sustitución directa ⚠️ Especificaciones sin verificar📋 Alternativa de referencia (no en el catálogo)
MAX3380EEUP+T
✅ Sustitución directa ⚠️ Especificaciones sin verificarConsulte el precio
Ver hoja de datos →MAX3381EEUP+T
✅ Sustitución directa ⚠️ Especificaciones sin verificarConsulte el precio
Ver hoja de datos →MAX3381ECUP+T Especificaciones
| Product Type | RS-232 transceiver |
| Transmitter Count | 2 |
| Receiver Count | 2 |
| Duplex Mode | Full duplex |
| Supply Voltage Range | 2.35V to 5.5V |
| Maximum Data Rate | 250kbps |
| ESD Protection | 15kV |
| Specified Current | 1A |
| Interface Standard | EIA/TIA-232 |
| Communication Standards | V.28 and V.24 |
| Power Requirements | Low power |
| Encapsulado | 20-TSSOP |
| Tipo de montaje | Surface mount |
Guía de configuración de pines de MAX3381ECUP+T 20-tssop
Configuración de pines para MAX3381ECUP+T (encapsulado 20-tssop). La numeración de pines, las funciones y los diagramas de conexión se definen en la hoja de datos del fabricante. Consúltela para conocer el footprint exacto y las directrices de soldadura.
No hay datos detallados de patillaje disponibles para MAX3381ECUP+T.
Consulte la hoja de datos para ver la configuración completa de patillas.
Aplicaciones típicas
MAX3381ECUP+T es adecuado para 6 aplicacións: Industrial Control Serial Interfaces, Point-of-Sale Terminal Communication, Data Acquisition and Instrumentation, Embedded Service and Configuration Ports, Communication Hubs and Serial Routers, Programmable Logic and MCU UART Links.
Industrial Control Serial Interfaces
The MAX3381ECUP+T fits industrial control equipment that must bridge a low-voltage UART controller to a full-duplex RS-232 link. Its 2.35V to 5.5V operating range supports both 3.3V embedded processors and 5V controller platforms, while the two transmitters and two receivers provide dedicated outbound and inbound channels. The 250kbps rate supports supervisory commands, configuration transfers, and status monitoring. Its 15kV ESD protection adds useful system-level resilience on connector-facing circuits, although the assembled interface still requires appropriate grounding, shielding, and surge protection for the installation environment.
Point-of-Sale Terminal Communication
The MAX3381ECUP+T can serve as the RS-232 interface between a point-of-sale controller and a peripheral such as a receipt printer, customer display, or magnetic-card reader. The 250kbps data rate is comfortably above the throughput required by typical transaction traffic, and full-duplex operation permits simultaneous command transmission and response reception. Operation from a 3.3V rail helps reduce system power in compact terminals. Two transmit and two receive channels also support multiple peripheral ports when the host uses independent UART channels. Placement near the connector is recommended so that ESD-protected interface pins receive the least exposed copper routing.
Data Acquisition and Instrumentation
The MAX3381ECUP+T is appropriate for laboratory and industrial instrumentation that uses RS-232 as a control or measurement-data link. Its 250kbps maximum data rate supports command polling and moderate-volume data transfer, while the two receiver channels can monitor two incoming signals and the two transmitter channels can drive separate outbound buses when required. The single-supply charge-pump architecture simplifies implementation in 3.3V and 5V embedded instruments. Designers should maintain a continuous return path between connected equipment, place bypass capacitance at the supply pins, and test the interface under the ground-potential differences common on long serial cables.
Embedded Service and Configuration Ports
The MAX3381ECUP+T is useful in embedded systems that retain an RS-232 service connector for configuration, diagnostics, or firmware maintenance. Running from 2.35V to 5.5V allows the interface to coexist with modern low-voltage processors, and the 250kbps rate provides adequate speed for boot logs and command-line maintenance sessions. Full-duplex operation helps avoid protocol restrictions caused by a single shared direction path. The 15kV ESD protection on logic and interface pins improves resilience during connector handling. For field reliability, retain the connector chassis ground near the board entry point and route the high-voltage RS-232 traces away from sensitive clock and sensing circuitry.
Communication Hubs and Serial Routers
A serial router or communication hub can use the MAX3381ECUP+T when two independent RS-232 paths are advantageous. One transmitter and receiver pair can face the upstream controller, while the other pair connects a downstream field device. The full-duplex architecture supports simultaneous traffic in each path, and the 250kbps rate is suitable for command-oriented protocols, diagnostic channels, and low-to-moderate data streams. Because each line interface is exposed to an external connector, the integrated 15kV ESD protection helps reduce component stress. Proper grounding remains essential because RS-232 voltage levels are referenced to ground, and incorrect cable grounding can cause communication errors independently of transceiver performance.
Programmable Logic and MCU UART Links
The MAX3381ECUP+T connects a programmable-logic device or microcontroller UART to an RS-232 port without requiring an external level-shifting network. Its 2.35V minimum supply voltage is compatible with low-voltage logic systems, while 250kbps operation provides sufficient signaling rate for standard serial-control protocols. The two transmitters and two receivers give the design flexibility for bidirectional communication or dual-port equipment. In an FPGA-based system, the interface pins can be assigned in the same way as ordinary UART signals, while the analog RS-232 line handling remains isolated on the opposite side of the IC. Place decoupling and charge-pump support components close to their associated pins according to the datasheet layout guidance.
Datos de referencia de ingeniería para MAX3381ECUP+T — comparación, orientación de diseño e información de cumplimiento.
Guía de selección
Comparación con alternativas
| Parámetro | Este producto | MAX3380ECUP+T | MAX3381CUP+T | MAX3380CUP+T | MAX3380EEUP+T | MAX3381EEUP+T |
|---|---|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Package | 20-TSSOP | 20-TSSOP | 20-TSSOP | 20-TSSOP | 20-TSSOP | 20-TSSOP |
| Transmitter Count | 2 | 2 | 2 | 2 | 2 | 2 |
| Receiver Count | 2 | 2 | 2 | 2 | 2 | 2 |
| Maximum Data Rate | 250kbps | Lower than 250kbps | 250kbps | Lower than 250kbps | Lower than 250kbps | 250kbps |
| Supply Voltage Range | 2.35V to 5.5V | 2.35V to 5.5V | 2.35V to 5.5V | 2.35V to 5.5V | 2.35V to 5.5V | 2.35V to 5.5V |
| ESD Protection | 15kV | 15kV | Lower than 15kV | Lower than 15kV | 15kV | 15kV |
| Duplex Mode | Full duplex | Full duplex | Full duplex | Full duplex | Full duplex | Full duplex |
| Interface Standard | EIA/TIA-232, V.28 and V.24 | EIA/TIA-232, V.28 and V.24 | EIA/TIA-232, V.28 and V.24 | EIA/TIA-232, V.28 and V.24 | EIA/TIA-232, V.28 and V.24 | EIA/TIA-232, V.28 and V.24 |
Diferenciadores clave
- Higher maximum serial data rate in the MAX3381 family (frente a MAX3380ECUP+T)
- Maximum listed ESD protection for exposed interface pins (frente a MAX3381CUP+T)
- Matched 250kbps performance with a broader temperature-grade choice (frente a MAX3381EEUP+T)
Notas de diseño
Place the charge-pump capacitors and supply bypass capacitors immediately beside their associated MAX3381ECUP+T pins. Keep the high-voltage RS-232 traces short where possible, provide a continuous ground reference beneath the interface area, and avoid routing them parallel to sensitive clocks or sensor inputs. The 20-TSSOP footprint uses a narrow lead pitch, so assembly inspection should verify solder bridging and pin-to-pin continuity after reflow.
Do not treat the 15kV ESD rating as protection against every RS-232 cable event. ESD performance depends on correct use of the interface pins, clean ground connections, and an appropriate enclosure and chassis strategy. Verify the complete pin configuration in the manufacturer datasheet before assigning receiver inputs, transmitter outputs, enable controls, and charge-pump components. Also confirm that the UART baud rate and cable length are compatible with the selected 250kbps operating mode.
For systems containing both RS-232 and sensitive analog circuitry, orient the connector and transceiver toward the board edge and keep logic-side traces away from the connector-facing section. Maintain a low-impedance ground plane and use a dedicated return path where practical. If a protection network is added, coordinate its capacitance and clamping behavior with the transceiver's receiver thresholds to avoid degrading signal integrity or timing.
Información de cumplimiento
No definitive RoHS, REACH, lead-free, halogen-free, or conflict-minerals statement was identified for the exact ordering code. The device is a commercial interface IC, not an automotive-qualified variant.