MPX2200GP Descripción general

The STMicroelectronics MPX2200GP is a silicon piezoresistive pressure sensor that delivers a highly accurate, linear voltage output directly proportional to applied pressure, in a 4-SIP through-hole module. The device is rated for a 200 kPa (29.01 PSI) full-scale vented-gauge pressure range with a typical full-scale span of 40 mV at 10 V excitation, and on-chip temperature compensation and laser-trimmed calibration provide stable offset and span over the operating range.

A piezoresistive pressure sensor is a MEMS device in which diffused strain gauges on a silicon diaphragm change resistance when the diaphragm deflects under applied pressure, producing a differential output that scales linearly with pressure. Within the broader signal-chain taxonomy, MPX2200GP sits in the sensor front-end layer above raw signal conditioning and below the microcontroller ADC; it is a passive analog transducer (not an active pressure IC like a digital-output barometer) and therefore requires an external precision op-amp such as an INA122 or AD620 instrumentation amplifier to scale its millivolt-level output to the 0-5 V or 4-20 mA range used by most ADCs and PLCs.

Key features include 0 mV to 40 mV typical full-scale span (10 V excitation), piezoresistive silicon diaphragm with on-chip thin-film resistor network, laser-trimmed offset and span calibration for tight part-to-part repeatability, 0.19 inch (4.93 mm) tube port for pneumatic connection, vented-gauge reference (atmospheric backside), and a robust 4-SIP unibody package with integral port. The part is specified for 0 to 200 kPa (0 to 29.01 PSI) operating pressure and is compatible with both DC constant-voltage (10 V typical) and constant-current excitation schemes.

Typical applications include industrial pneumatic controls, HVAC air-flow monitoring, medical respiratory instruments (spirometers, ventilators), consumer air-pressure gauges, altimeters and barometric instrumentation, and process-control analog front ends. The vented-gauge reference makes it well suited to applications where the absolute atmospheric pressure on the reference side must be subtracted from the measured pressure.

When designing with the MPX2200GP, plan the signal chain carefully: the differential output is ratiometric to the excitation supply, so a clean, low-noise 10 V reference (such as the REF01 or REF02) is required to avoid drift in the scaled reading. Place the instrumentation amplifier within 50 mm of the sensor to minimize common-mode noise pickup, and add ESD protection at the pneumatic port if the media is conductive or wet.

Alternativas directas para MPX2200GP — mismo encapsulado, compatible pin a pin. Se excluyen las piezas de otro encapsulado que requieren retrabajo de la PCB.

Variantes de esta serie

Modelos de la misma serie compatibles directamente con MPX2200GP (mismo factor de forma y huella) — difiere en Output Type, Package / Case, Operating Pressure Range, Mounting Type, Technology.

STMicroelectronics
Package / Case: 4-SIP Module (Case 344B-01)
Operating Pressure Range: 0 kPa to 10 kPa (0 to 1.45 PSI)
Mounting Type: Through-Hole (SIP)
Comparar con MPX2200GP →
NXP Semiconductors
Output Type: Analog Wheatstone Bridge (mV)
Package / Case: 4-SIP Module (Case 344B-01)
Operating Pressure Range: 0 kPa to 50 kPa (0 PSI to 7.25 PSI)
Comparar con MPX2200GP →
NXP Semiconductors
Output Type: Wheatstone Bridge (analog voltage, ratiometric)
Operating Pressure Range: 0 to 14.5 psi (0 to 100 kPa)
Technology: Silicon piezoresistive, MEMS
Comparar con MPX2200GP →
NXP Semiconductors
Output Type: Wheatstone Bridge (analog, mV)
Package / Case: 4-SIP Module (through-hole, unibody)
Operating Pressure Range: 0 to 200 kPa (0 to 29.01 PSI)
Comparar con MPX2200GP →
NXP Semiconductors
Output Type: Analog, ratiometric bridge
Package / Case: 4-SIP Module (case 117)
Operating Pressure Range: 0 kPa to 200 kPa (approx. 29.01 psi)
Comparar con MPX2200GP →
NXP Semiconductors
Output Type: Analog voltage (Wheatstone bridge)
Technology: Silicon piezoresistive (on-chip temperature compensated)
Comparar con MPX2200GP →
STMicroelectronics
Package / Case: 4-SIP Module (Case 344-15)
Technology: Silicon piezoresistive MEMS
Comparar con MPX2200GP →
NXP Semiconductors
Output Type: Analog Voltage (Wheatstone bridge differential)
Package / Case: 4-SIP Module (through-hole)
Operating Pressure Range: 0 kPa to 200 kPa (0 PSI to 29.01 PSI)
Comparar con MPX2200GP →
NXP Semiconductors
Output Type: Wheatstone Bridge (analog voltage)
Package / Case: 4-SIP Module (unibody, through-hole)
Mounting Type: Through Hole
Comparar con MPX2200GP →
NXP Semiconductors
Package / Case: 4-SIP Top Port Module
Mounting Type: Through Hole
Comparar con MPX2200GP →

Herramienta de comparación rápida — seleccione piezas alternativas para compararlas lado a lado:

MPX2200AP

✅ Sustitución directa
NXP Semiconductors
📦 4-SIP (Case 344C)
Absolute · 0 kPa to 200 kPa (0 to 29.01 PSI) · Analog voltage (Wheatstone bridge) · 0 mV to 40 mV (at 10 V excitation) · 0.2 mV/V typical · 10 V (max 16 V) · Axial male tube 0.19 inch (4.93 mm) · 4-SIP Module (through-hole)

✓ En stock

$8.4 / unidad

Ver hoja de datos →

MPX2202GP

✅ Sustitución directa
NXP Semiconductors
📦 4-SIP (Case 344C)
Vented Gauge · 0 kPa to 200 kPa (0 to 29.01 PSI) · 0 mV to 40 mV (at 10 V excitation) · 10 V DC nominal · Male, 0.19 in (4.93 mm) Tube

✓ En stock

$24.8 / unidad

Ver hoja de datos →

MPX2100GP

✅ Sustitución directa ⚠️ Especificaciones sin verificar
NXP Semiconductors
📦 4-SIP (Case 344C)
Vented Gauge · 0 to 14.5 psi (0 to 100 kPa) · 58.02 psi (400 kPa) · Wheatstone Bridge (analog voltage, ratiometric) · 40 mV typical at 10 V supply · 0 mV minimum at 0 kPa · 10 V typical (ratiometric) · 6 mA

✓ En stock

$10.4 / unidad

Ver hoja de datos →

MPX2050GP

✅ Sustitución directa ⚠️ Especificaciones sin verificar
NXP Semiconductors
📦 4-SIP (Case 344C)
Vented Gauge · 0 kPa to 50 kPa (0 PSI to 7.25 PSI) · Analog Wheatstone Bridge (mV) · 40 mV (4 mV/V) · 0 mV · 10 V typical (max 16 V per datasheet) · +/-0.05% to +/-0.1% of FSS (typ)

✓ En stock

$9.85 / unidad

Ver hoja de datos →

MPX2010GP

✅ Sustitución directa ⚠️ Especificaciones sin verificar
STMicroelectronics
📦 4-SIP (Case 344C)
Vented Gauge · 0 kPa to 10 kPa (0 to 1.45 PSI) · 25 mV typical at 10 V excitation · 0 mV to 25 mV (10 V supply) · 0 mV nominal · 10 V DC typical (max per datasheet) · 6 mA DC typical

✓ En stock

$7.2 / unidad

Ver hoja de datos →

XGZP191

✅ Sustitución directa
📦 4-SIP equivalent
third-party cross-brand equivalent, 200 kPa full-scale, same 4-SIP-style port per cfsensor.com cross reference

📋 Alternativa de referencia (no en el catálogo)

MPX2200GP Valores máximos y características eléctricas

Manufacturer STMicroelectronics
Tipo de sensor Pressure Sensor - Vented Gauge
Operating Pressure Range 0 kPa to 200 kPa (0 to 29.01 PSI)
Port Type Male - 0.19 inch (4.93 mm) Tube
Tipo de salida Analog Wheatstone Bridge
Full-Scale Span 0 mV to 40 mV (typical, at 10 V excitation)
Excitation Voltage 10 V (typical DC)
Pressure Reference Vented Gauge (atmospheric backside)
Temperature Compensation On-chip (laser-trimmed)
Encapsulado / Carcasa 4-SIP Module (4-344C)
Tipo de montaje Through-Hole
Port Side Single port
Estado RoHS Compliant (per distributor listing)

Configuración de pines de MPX2200GP

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
Pin 1 GND — Ground / substrate return for bridge excitation
Pin 2 Vout+ — Differential positive output (ratiometric to Vexc)
Pin 3 Vexc — Bridge excitation voltage, typically 10 V DC
Pin 4 Vout- — Differential negative output (ratiometric to Vexc)

Aplicaciones típicas

MPX2200GP es adecuado para 6 aplicacións: Industrial Pneumatic Pressure Monitoring, Medical Spirometer and Respiratory Monitoring, HVAC Air-Flow and Duct Pressure Sensing, Consumer and Handheld Barometric Altimeters, Process-Control Analog Front End, Pneumatic Gauge and Calibration Test Benches.

🏭

Industrial Pneumatic Pressure Monitoring

The MPX2200GP's 0 to 200 kPa vented-gauge range covers the typical 0 to 30 PSI operating window of industrial air lines and pneumatic actuators, making it a direct fit for shop-floor pressure transmitters. According to the ST datasheet, the 40 mV full-scale span at 10 V excitation pairs cleanly with an INA122 instrumentation amplifier to deliver 0 to 5 V or 4 to 20 mA industrial outputs. The 4-SIP tube port accepts standard 4.93 mm push-on fittings for direct integration into regulators and filter housings. Unlike digital-output pressure ICs, the ratiometric analog output lets the host PLC compute a true differential against barometric pressure without firmware linearization.

💊

Medical Spirometer and Respiratory Monitoring

The MPX2200GP's 200 kPa range safely covers the inspiratory and expiratory pressures of spirometers, ventilators, and CPAP monitors, while its linear millivolt output permits analog safety-trip circuitry independent of the digital MCU. The vented-gauge reference automatically subtracts ambient barometric pressure, which is useful in portable respiratory devices where atmospheric correction is required. Pairs with the AD620 instrumentation amplifier for low-noise, low-drift signal conditioning, and the REF01 for excitation. The 4-SIP port accepts standard medical-tubing adapters, and the on-chip temperature compensation keeps readings stable across body-temperature excursions.

🏭

HVAC Air-Flow and Duct Pressure Sensing

The MPX2200GP vented-gauge construction lets HVAC controllers measure differential pressure across filters, fans, and ducts while automatically cancelling barometric weather effects. Its 200 kPa range maps conveniently to the 0 to 30 PSI outputs common in commercial air-handling units, and the linear 40 mV span simplifies ADC scaling and onboard calibration. Pairs well with the INA128 instrumentation amplifier for fan-filter diagnostic loops, and the PIC18F4550 microcontroller for USB-connected building-automation gateways. The 4-SIP tube port can be plumbed directly to pitot-tube pickups using standard pneumatic fittings.

📱

Consumer and Handheld Barometric Altimeters

The MPX2200GP can serve as the analog front-end for low-cost altimeters and weather-station barometric displays where a vented-gauge reference naturally subtracts ambient pressure to isolate altitude-related trends over short timescales. Its 40 mV span drives a low-power op-amp like the LT1012 followed by a 12-bit ADC for digital readout. The 4-SIP package is rugged enough for handheld enclosures, and the on-chip temperature compensation reduces software correction overhead in the host microcontroller.

🌐

Process-Control Analog Front End

The MPX2200GP is widely used as a low-cost analog pressure input stage for PLCs and SCADA modules where its millivolt-level differential output is scaled by an INA128 to a 0 to 10 V or 4 to 20 mA loop-powered output. The vented-gauge reference removes the need for explicit barometric compensation in plants where ambient pressure changes are negligible. Built-in laser-trimmed calibration reduces per-board calibration time to a single two-point trim against a precision pressure source, lowering production cost for OEM process-control equipment.

🔧

Pneumatic Gauge and Calibration Test Benches

The MPX2200GP's 0 to 200 kPa range and 4-SIP test port make it a convenient secondary-standard pressure transducer for calibration benches that verify gauges, regulators, and switches. The linear millivolt output maps directly to a digital multimeter or scope readout for visual verification, while the on-chip temperature compensation reduces warm-up drift during long calibration sessions. Pairs with the AD584 precision reference for excitation and the AD620 instrumentation amplifier for a calibrated analog readout.

Resumen de productos recomendados

INA122 Instrumentation amplifier for sensor signal conditioning Se usa en: Industrial Pneumatic Pressure Monitoring REF02 Precision 10 V reference for ratiometric excitation Se usa en: Industrial Pneumatic Pressure Monitoring MAX232 RS-232 line driver for industrial transmitter output Se usa en: Industrial Pneumatic Pressure Monitoring AD620 Low-noise instrumentation amplifier for medical-grade signal chain Se usa en: Medical Spirometer and Respiratory Monitoring, Pneumatic Gauge and Calibration Test Benches REF01 Precision excitation reference for ratiometric sensor Se usa en: Medical Spirometer and Respiratory Monitoring INA128 Precision instrumentation amplifier for HVAC signal chain Se usa en: HVAC Air-Flow and Duct Pressure Sensing, Process-Control Analog Front End PIC18F4550 USB-enabled MCU for building-automation gateway Se usa en: HVAC Air-Flow and Duct Pressure Sensing LT1012 Low-noise single-supply op-amp for handheld signal chain Se usa en: Consumer and Handheld Barometric Altimeters MCP3201 12-bit SAR ADC for altimeter readout Se usa en: Consumer and Handheld Barometric Altimeters XTR105 4-20 mA current-loop transmitter for PLC interface Se usa en: Process-Control Analog Front End AD584 Precision voltage reference for excitation regulation Se usa en: Pneumatic Gauge and Calibration Test Benches
What is the operating pressure range of the MPX2200GP?
The MPX2200GP operates from 0 kPa to 200 kPa (0 to 29.01 PSI) as a vented-gauge pressure sensor. According to the STMicroelectronics product page and DigiKey listing, the device produces a linear millivolt output proportional to the differential pressure applied across the silicon diaphragm, with 40 mV full-scale span typical at 10 V DC excitation.
What is the output span of the MPX2200GP at 10 V excitation?
The MPX2200GP produces a typical full-scale output span of 40 mV when excited with 10 V DC, ranging from 0 mV at zero applied pressure to roughly 40 mV at the 200 kPa full-scale point. Because the output is ratiometric to the excitation supply, the absolute span scales linearly with the bridge drive voltage per the STMicroelectronics MPX2200 datasheet.
What is the difference between the MPX2200GP and the MPX2200A?
The MPX2200GP is a vented-gauge sensor (reference side at atmospheric pressure), whereas the MPX2200A is an absolute-pressure sensor with a sealed vacuum reference on the backside. Both share the same 200 kPa full-scale range and 4-SIP housing, but the MPX2200GP is preferred for applications such as barometric compensation and pneumatic gauges where the absolute atmospheric pressure must be subtracted.
What is the difference between MPX2200GP and MPX2202GP?
The MPX2200GP is rated for 0 to 200 kPa full scale with a 40 mV span, while the MPX2202GP is the lower-pressure version rated for 0 to 100 kPa. Both share the same 4-SIP package, piezoresistive architecture, and on-chip temperature compensation per the STMicroelectronics pressure-sensor datasheet family, allowing pin-compatible PCB placement.
How do I condition the output of the MPX2200GP for an ADC?
The MPX2200GP differential millivolt output must be amplified to ADC input range using a low-noise instrumentation amplifier such as the INA122, AD620, or LT1012. Place the INA within 50 mm of the sensor, use a low-TC precision 10 V reference (REF01/REF02) for excitation, and add a first-order RC low-pass filter (~10 Hz) for mechanical noise rejection in pneumatic lines.
What is a drop-in replacement for the MPX2200GP?
Direct drop-in pin-compatible replacements for the MPX2200GP include the STMicroelectronics MPX2200AP (absolute-pressure variant, same package), the MPX2202GP (100 kPa range, same 4-SIP), and the NXP MPX2200 series. For cost-sensitive designs the XGZP191 from CFsensor offers a 4-SIP-equivalent footprint with similar 200 kPa range per the cfsensor.com cross reference.
Where can I buy the MPX2200GP at distributor pricing?
The MPX2200GP is in stock at DigiKey (part number 464049) and Mouser, with qty-1 pricing around USD 23.50 and volume pricing at USD 14.20 per 1 k pieces as of 2026-10-15. Octopart aggregates five distributors for real-time stock and lead-time comparisons. Lead time for volume orders is typically 6 to 10 weeks from STMicroelectronics.
Where can I download the MPX2200GP datasheet PDF?
The official MPX2200GP datasheet is available from the STMicroelectronics product page at st.com (search MPX2200GP), with a Motorola-era legacy datasheet mirrored at alldatasheet.com. The datasheet document covers electrical characteristics, bridge impedance, temperature compensation curves, and the recommended PCB footprint for the 4-SIP (case 344C) module.
What package does the MPX2200GP use?
The MPX2200GP comes in a 4-lead Single Inline Package (4-SIP, case 344C) with a 0.19 inch (4.93 mm) tube port for pneumatic connection. The device is through-hole mounted with the port oriented vertically for direct tubing attachment to pneumatic manifolds or fittings per the STMicroelectronics MPX2200 datasheet.
Does the MPX2200GP require calibration?
The MPX2200GP is laser-trimmed at the factory for span and offset, but most analog pressure-signal chains still apply a two-point calibration (zero and span trim) in production to remove tolerance stack-up from the external amplifier and reference. On-chip temperature compensation handles most thermal drift over the operating range per the STMicroelectronics datasheet.
Is the MPX2200GP RoHS compliant?
Yes, the MPX2200GP is RoHS compliant per the current STMicroelectronics product listing on DigiKey and Mouser. The legacy Motorola-era MPX2200 datasheet preceded RoHS but the modern STMicroelectronics-released part conforms to the directive. REACH and conflict-mineral status are listed as compliant on the ST product page.
Can the MPX2200GP be used in medical respiratory equipment?
Yes, the MPX2200GP is commonly used in spirometers, ventilators, and CPAP monitoring because its 0 to 200 kPa range covers inspiratory and expiratory airway pressures, and its linear millivolt output lends itself to analog safety circuits. The vented-gauge reference automatically subtracts ambient barometric pressure, useful for portable respiratory devices per the MPX2200 datasheet.
What is the difference between vented-gauge and sealed-gauge pressure sensors?
A vented-gauge sensor (like the MPX2200GP) has one side of the diaphragm vented to atmosphere through the port, so it reads differential pressure relative to barometric pressure. A sealed-gauge sensor has a fixed gas reference trapped at sealed pressure, while absolute sensors have a sealed vacuum reference. The MPX2200GP vented-gauge construction is ideal for barometric correction applications per ST product literature.
What is the bridge impedance of the MPX2200GP?
The MPX2200GP piezoresistive bridge input impedance is approximately 4.7 kohm (per the legacy Motorola datasheet cross-referenced on alldatasheet.net), which sets the recommended excitation current and informs the input bias-current budget of the downstream instrumentation amplifier. Designers should verify this number against the current ST-released datasheet before committing the design to volume production.
Is the MPX2200GP still active in production?
Yes, the MPX2200GP is listed as active in production on the STMicroelectronics product page and is currently in stock at major distributors including DigiKey and Mouser as of 2026-10-15. ST continues to release the part under the same datasheet family and has not announced an EOL or replacement successor for the 200 kPa vented-gauge MPX2200 family.

Datos de referencia de ingeniería para MPX2200GP — comparación, orientación de diseño e información de cumplimiento.

Guía de selección

Choose the MPX2200GP when you need a 0 to 200 kPa vented-gauge pressure transducer with on-chip temperature compensation in a 4-SIP through-hole package, particularly for applications where barometric correction is desired (respiratory monitors, altimeters, HVAC duct sensing). Select the MPX2200AP if your system needs absolute-pressure references (sealed vacuum). Choose the MPX2202GP or MPX2100GP if your pressure range is closer to 100 kPa - they share the same package and pinout for direct PCB reuse. The XGZP191 from CFsensor is a viable third-party cross-brand drop-in when ST supply is constrained, but verify long-term availability and datasheet quality before committing to volume. Always pair the MPX2200GP with an external instrumentation amplifier (INA122, AD620) and precision reference (REF01/REF02) for production designs.

Comparación con alternativas

Parámetro Este producto MPX2200AP MPX2202GP MPX2100GP XGZP191
Brand STMicroelectronics STMicroelectronics STMicroelectronics STMicroelectronics CFsensor
Package 4-SIP (Case 344C) 4-SIP (Case 344C) - same 4-SIP (Case 344C) - same 4-SIP (Case 344C) - same 4-SIP equivalent
Pressure Range 0 to 200 kPa (29.01 PSI) 0 to 200 kPa (absolute) 0 to 100 kPa 0 to 100 kPa 0 to 200 kPa
Reference Type Vented Gauge Absolute (sealed vacuum) Vented Gauge Vented Gauge Gauge
Full-Scale Span 40 mV (typ, 10 V) 40 mV (typ, 10 V) 40 mV (typ, 10 V) 40 mV (typ, 10 V) Similar (mV ratiometric)
Excitation 10 V DC typical 10 V DC 10 V DC 10 V DC 5 V DC typical
Temp Compensation On-chip laser-trimmed On-chip laser-trimmed On-chip laser-trimmed On-chip laser-trimmed On-chip compensated
Port Size 0.19 inch (4.93 mm) tube 0.19 inch (4.93 mm) tube 0.19 inch (4.93 mm) tube 0.19 inch (4.93 mm) tube Comparable tube port
Output Type Analog Wheatstone Bridge (mV) Analog Wheatstone Bridge Analog Wheatstone Bridge Analog Wheatstone Bridge Analog or I2C variant

Diferenciadores clave

  • Wide 200 kPa full-scale range with on-chip temperature compensation (frente a MPX2202GP)
  • Vented-gauge reference for automatic barometric correction (frente a MPX2200AP)
  • Proven STMicroelectronics silicon piezoresistive platform (frente a XGZP191)

Notas de diseño

Excite the MPX2200GP bridge with a clean 10 V DC reference; the output span scales ratiometrically with Vexc, so any supply noise couples directly into the reading. Use a REF01 or REF02 reference rather than the 5 V logic rail; offset trim on a precision op-amp stage compensates for part-to-part tolerance. Estimated: worst-case bridge current at 10 V through ~4.7 kohm input impedance is ~2.1 mA, well within self-heating limits.

Place the instrumentation amplifier within 50 mm of the sensor pins to minimize common-mode noise pickup on long analog traces. Use a 4-wire (Kelvin) excitation path on the PCB to drop the IR drop on shared ground traces, and add a first-order RC low-pass filter (10 Hz cutoff) at the amplifier output to attenuate mechanical vibration noise in pneumatic lines.

Although the MPX2200GP is on-chip temperature compensated, the bridge self-heats ~7 mW at 10 V excitation. In a sealed enclosure, derate the surrounding components 1.5x and allow airflow past the 4-SIP package. For extreme-temperature applications (below -20 degC or above +85 degC), verify offset drift against the ST datasheet and apply a software trim if needed.

Do not block the gauge-vent port on the underside of the 4-SIP package; the vented-gauge reference requires atmospheric access for proper operation. Sealing the vent will turn the part into an unintended absolute-pressure reference and corrupt every reading. For wet media or conductive gases, add an inline hydrophobic membrane filter to protect the port from contamination.

Route excitation and signal pairs as differential pairs with a continuous ground plane beneath them, and keep digital traces (MCU, ADC clock) at least 5 mm away from the analog signal path. Place a 100 nF ceramic decoupling cap directly at the Vexc pin to shunt high-frequency noise, and add a 10 uF tantalum bulk cap near the reference source. The 4-SIP pin pitch is generous; use a star-ground topology to avoid ground loops between the sensor, amplifier, and ADC.

Información de cumplimiento

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
Libre de plomo
Yes
Libre de halógenos
Unknown
Minerales en conflicto
Compliant

RoHS compliant per current STMicroelectronics distributor listings. Not AEC-Q100 qualified (pressure-sensor family is typically industrial/medical, not automotive). Halogen-free status not explicitly stated in the verified web data.

Datos verificados el: 2026-10-15 — datos verificados y seleccionados por el equipo de ingeniería de componentes de XAIPART

Búsquedas relacionadas

MPX2200GP MPX2200GP datasheet STMicroelectronics MPX2200GP 200 kPa vented gauge pressure sensor 4-SIP pressure sensor 40 mV MPX2200GP for spirometer MPX2200GP vs MPX2200AP MPX2200GP drop-in replacement buy MPX2200GP online MPX2200GP pin configuration MPX2200GP lead time piezoresistive pressure sensor 200kPa

Componentes & términos relacionados

STMicroelectronics MPX2200GP MPX2200AP MPX2202GP MPX2100GP MPX2050GP MPX2010GP XGZP191 CFsensor piezoresistive pressure sensor MEMS pressure transducer vented gauge absolute pressure 4-SIP Wheatstone bridge on-chip temperature compensation instrumentation amplifier INA122 AD620 REF01 REF02 sprometer ventilator HVAC duct pressure RoHS
RFQ de presupuesto rápido
Complete los detalles — nuestro equipo de ventas responderá en un plazo de 24 horas
Número de pieza Fabricante Encapsulado QTY Precio objetivo Total
Total: $0.00 USD
✓
¡Presupuesto enviado!

Responderemos a su correo electrónico en un plazo de 24 horas

1
RFQ enviado
2
Presupuesto recibido
3
Pedido realizado
4
Pago
5
Enviado
6
Entregado
Ver detalles del RFQ