SN75138N - Quad Bus Transceiver | Texas Instruments
N.º de pieza: SN75138N ✓ ActivoSN75138N Descripción general
A bus transceiver is an interface IC that connects digital logic to a shared or point-to-point transmission line. Its driver stage translates TTL logic into an appropriate line-level output, while its receiver stage converts the returned signal into a logic-compatible output. In the SN75138N, the receiver input is internally connected to the corresponding driver output, allowing each channel to support two-way bus communication.
The SN75138N includes common driver-strobe TTL-compatible inputs and clamp diodes on its driver outputs. The common strobe inputs provide a coordinated way to control all four open-collector drivers, which is useful when multiple devices must enter or leave a bus state together. The 100 mA open-collector output capability also permits the drivers to sink substantial bus current while supporting wired-AND behavior on a shared bus.
Each of the four channels is electrically identical, which simplifies system design when several devices communicate through the same package. The high-input-impedance receivers reduce loading on the transmission line, while the high-threshold receivers help distinguish active bus states from noise or inactive line conditions. The open-collector outputs require an external pull-up resistor when used with a wired bus.
Typical applications include bidirectional single-ended data links, computer peripheral interfaces, industrial control buses, test equipment, and embedded systems that require several independently controlled transceiver channels. The combination of four channels, TTL-compatible logic, and open-collector bus outputs is particularly useful when a design needs bidirectional data flow without assigning a separate transceiver IC to each signal.
When laying out the PCB, place the device close to the connector or transmission-line interface and route driver and receiver paths to minimize stub lengths and crosstalk. Provide a suitable pull-up resistor on each wired-AND bus, and check the total sink current from all connected drivers. The 16-pin PDIP package also requires adequate spacing around the leads for through-hole insertion and soldering.
This page consolidates the SN75138N function, verified technical characteristics, package information, design guidance, and replacement considerations. It supports faster component selection by separating verified device facts from practical PCB, bus, and sourcing guidance engineers can apply during design-in.
Alternativas directas para SN75138N — mismo encapsulado, compatible pin a pin. Se excluyen las piezas de otro encapsulado que requieren retrabajo de la PCB.
No hay alternativas directas disponibles para este producto.
Solicitar alternativasSN75138N Especificaciones
| Product Type | Quadruple bus transceiver |
| Number of Channels | 4 channels |
| Transceiver Configuration | 4 transmitter and 4 receiver channels |
| Tensión de alimentación | 5 V |
| Encapsulado | 16-pin PDIP |
| Tipo de montaje | Through-hole |
| Receiver Input Impedance | High impedance |
| Receiver Switching Threshold | High threshold |
| Driver Input Compatibility | TTL-compatible |
| Strobe Input Compatibility | TTL-compatible |
| Driver Output Type | Open-collector |
| Open-Collector Output Current | 100 mA |
| Output Protection | Clamp diodes |
| Communication Mode | Two-way, single-ended |
Guía de configuración de pines de SN75138N 16-pin pdip
Configuración de pines para SN75138N (encapsulado 16-pin pdip). La numeración de pines, las funciones y los diagramas de conexión se definen en la hoja de datos del fabricante. Consúltela para conocer el footprint exacto y las directrices de soldadura.
No hay datos detallados de patillaje disponibles para SN75138N.
Consulte la hoja de datos para ver la configuración completa de patillas.
Aplicaciones típicas
SN75138N es adecuado para 6 aplicacións: Bidirectional Single-Ended Data Links, Computer Peripheral Interfacing, Industrial Control Signal Bus, Test and Measurement Equipment, Legacy Embedded System Bus Interface, Wired-AND Control Network.
Bidirectional Single-Ended Data Links
The SN75138N is suitable when a system needs four independent two-way communication paths between TTL logic and a single-ended transmission line. Each channel combines a TTL-compatible open-collector driver with a high-impedance receiver, allowing the same conductor to carry outbound data and return a response. Using four channels in one 16-pin PDIP reduces package count, while the open-collector architecture supports wired-AND behavior when the bus includes pull-up resistors.
Recomendado
Computer Peripheral Interfacing
The four-channel architecture of the SN75138N can connect multiple peripheral-control or status signals to older TTL-compatible computer equipment. Each driver accepts TTL logic and provides an open-collector bus output capable of sinking up to 100 mA, while each receiver returns a TTL-compatible signal. The common driver-strobe inputs are useful when related output channels must be enabled together, helping simplify control of a multi-signal peripheral interface.
Recomendado
Industrial Control Signal Bus
The SN75138N can support low- or moderate-speed control and status signaling between a controller and remote equipment over single-ended lines. Its high-impedance receiver inputs limit loading, and the open-collector outputs permit shared-bus wired-AND operation with suitable pull-up components. For industrial equipment, use the manufacturer electrical limits and environmental qualifications to confirm that the device matches the enclosure temperature, noise, and ESD requirements.
Recomendado
Test and Measurement Equipment
A four-channel bus transceiver is useful in test fixtures and legacy instrumentation that require bidirectional command, response, and status paths. The SN75138N combines four receivers and four open-collector drivers in a single 16-pin PDIP, allowing several instrument-control lines to share one interface component. Keep driver and receiver routes away from sensitive analog sections, terminate buses according to the system topology, and verify timing margins at the intended communication rate.
Recomendado
Legacy Embedded System Bus Interface
The SN75138N can bridge TTL-compatible embedded logic to external single-ended bus lines where four bidirectional channels are required. Driver inputs and common strobes use familiar TTL levels, while high-impedance receivers help preserve signal integrity on the line. Because open-collector outputs require pull-up resistors, the system's voltage, resistance, capacitance, and sink-current budget must be evaluated before the board is released for production.
Recomendado
Wired-AND Control Network
The SN75138N's open-collector outputs are suited to wired-AND control networks in which multiple devices can pull a shared line low. Four independent channels allow several related signals to use the same interface technique, while the common strobe inputs can coordinate driver states. Every shared line requires an appropriate pull-up resistor, and the design must account for simultaneous low states from multiple drivers when calculating resistor values and maximum bus current.
Recomendado
Resumen de productos recomendados
Datos de referencia de ingeniería para SN75138N — comparación, orientación de diseño e información de cumplimiento.
Guía de selección
Comparación con alternativas
| Parámetro | Este producto |
|---|---|
| Package | 16-pin PDIP |
| Brand | Texas Instruments |
| Product Type | Quadruple bus transceiver |
| Number of Channels | 4 |
| Supply Voltage | 5 V |
| Driver Output Type | Open-collector |
| Open-Collector Output Current | 100 mA |
| Receiver Input Impedance | High impedance |
| Driver and Strobe Input Logic | TTL-compatible |
| Communication Mode | Two-way, single-ended |
Notas de diseño
The SN75138N uses open-collector driver outputs, so every positive-high bus must include a suitable pull-up resistor. Confirm the resistor against the bus voltage, capacitance, signal rise-time requirement, and the maximum sink current from all connected drivers. Avoid assuming that an open-collector output actively drives a high level; the external pull-up performs that function.
Place the SN75138N near the connector or transmission-line interface and keep each driver and receiver route short. Minimize stubs and maintain the intended return path beneath the signal where practical. Poorly positioned traces can increase ringing, crosstalk, and susceptibility to induced noise, particularly when several open-collector outputs share a bus or when the connected line has appreciable capacitance.
Use the common driver-strobe inputs as intended rather than enabling only some drivers in a coordinated bus without checking the resulting bus state. Review the SN75138 truth table and enable requirements in the manufacturer documentation. A driver that is unexpectedly active or disabled can hold the wired-AND line low, preventing other nodes from communicating.
Keep the 16-pin PDIP away from high-current switching paths, inductors, and high-voltage switching nodes. The DIP footprint requires adequate board clearance for the leads and assembly tooling. If the transceiver connects to a connector, place the pull-up resistors close enough to minimize exposed high-impedance trace length, but still follow the bus's required topology and current-budget calculations.
Información de cumplimiento
RoHS, REACH, lead-free, halogen-free, and conflict-minerals status were not established from the verified product records. AEC-Q100 is not applicable because the verified device is a through-hole interface IC rather than an automotive-qualified orderable variant.