TCAN1051HGVD - 5 Mbps Fault-Protected CAN FD | Texas Instruments
N.º de pieza: TCAN1051HGVD ✓ ActivoTCAN1051HGVD Descripción general
A CAN transceiver is the physical-layer interface between a CAN controller and a CAN bus. The TCAN1051HGVD combines a CAN transmitter, CAN receiver, bus-driver protection, and I/O level shifting in one package. Within the product hierarchy, it belongs to the CAN transceiver class of interface integrated circuits, connecting automotive and industrial embedded systems to a differential CAN network.
The device supports CAN FD data rates up to 5 Mbps, as indicated by the G designation in the TCAN1051HGV family. Its VIO pin permits the RXD and other digital I/O interface voltage to operate independently from VCC. The family meets the ISO 11898-2:2016 high-speed CAN physical-layer standard and the ISO 11898-5:2007 standard. Fault-protection features help improve system behavior when the bus experiences abnormal conditions.
TCAN1051HGVD operates from a 4.5 V to 5.5 V transceiver supply and supports an extended temperature range of -55 °C to 125 °C. Its 8-SOIC package offers a compact surface-mount footprint for industrial controllers, vehicle electronics, gateways, and embedded CAN nodes. The VIO architecture is especially useful when the host controller uses 3.3 V logic while the CAN side uses 5 V.
Typical applications include CAN FD gateways, industrial automation equipment, automotive body and chassis modules, building-control systems, robotics, and embedded communications equipment. The part is appropriate when a design needs higher CAN FD throughput, bus-fault handling, and host-side voltage flexibility while retaining a conventional 8-pin SOIC footprint.
PCB design should preserve the differential CANH and CANL route as a controlled-impedance pair, keep the transceiver close to the connector, and provide the power and ground decoupling recommended by the manufacturer datasheet. Confirm the VIO voltage, mode-control logic, bus termination, and transceiver-versus-controller pin mapping before releasing a layout.
This page combines manufacturer specifications, practical application guidance, pin-level design considerations, and drop-in alternatives to support component selection, schematic review, PCB layout, sourcing, and second-source qualification.
Alternativas directas para TCAN1051HGVD — mismo encapsulado, compatible pin a pin. Se excluyen las piezas de otro encapsulado que requieren retrabajo de la PCB.
Variantes de esta serie
Modelos de la misma serie compatibles directamente con TCAN1051HGVD (mismo factor de forma y huella) — difiere en Operating Temperature Range, Package, Product Type.
TCAN1042HGV
✅ Sustitución directa📋 Alternativa de referencia (no en el catálogo)
TCAN1042HGD
✅ Sustitución directa ⚠️ Especificaciones sin verificar📋 Alternativa de referencia (no en el catálogo)
TCAN1051HGD
✅ Sustitución directa ⚠️ Especificaciones sin verificar📋 Alternativa de referencia (no en el catálogo)
TCAN1051HGVDRQ1
✅ Sustitución directaConsulte el precio
Ver hoja de datos →ATA6564-GAQW1
✅ Sustitución directa📋 Alternativa de referencia (no en el catálogo)
TCAN1051HGVD Especificaciones
| Product Type | Fault-protected CAN FD transceiver |
| Maximum Data Rate | 5 Mbps |
| Transceiver Supply Voltage Range | 4.5 V to 5.5 V |
| Secondary I/O Supply | VIO pin for I/O level shifting |
| CAN Physical-Layer Standard | ISO 11898-2:2016 |
| Fault-Protection Standard | ISO 11898-5:2007 |
| Rango de temperatura de funcionamiento | -55 °C to 125 °C |
| Encapsulado | 8-SOIC (D), 3.90 mm width |
| Número de pines | 8 pins |
| Tipo de montaje | Surface mount |
| Transceiver Type | 1 transmit, 1 receive half CANbus |
| Operating Modes | Normal and silent |
| Logic Supply Input | VIO |
| Transceiver Supply Input | VCC |
| CAN Bus Differential Pins | CANH and CANL |
| Controller Interface Pins | TXD and RXD |
| Standby Control | STB |
| Manufacturer Operating-Mode Description | Normal and silent modes |
Configuración de pines de TCAN1051HGVD
| Pin 1 | CANH — CAN bus high terminal |
| Pin 2 | CANL — CAN bus low terminal |
| Pin 3 | VCC — Transceiver supply voltage input |
| Pin 4 | GND — Device ground |
| Pin 5 | VIO — Secondary I/O supply input for level shifting |
| Pin 6 | RXD — CAN receive data output |
| Pin 7 | TXD — CAN transmit data input |
| Pin 8 | STB — Standby mode control input |
Aplicaciones típicas
TCAN1051HGVD es adecuado para 6 aplicacións: Industrial CAN FD Gateway, Automotive Body Control Module, Robotics Motor Coordination Network, Building Control and HVAC Equipment, Embedded Test and Measurement Instrument, Portable Diagnostics and Service Tool.
Industrial CAN FD Gateway
The TCAN1051HGVD fits industrial gateways that must bridge a 5 Mbps CAN FD segment to an Ethernet, serial, or embedded host controller. Its 8-SOIC package preserves a compact transceiver footprint, while the VIO supply permits 3.3 V host-side interfacing when the logic rail is selected appropriately. The 4.5 V to 5.5 V VCC range supports regulated 5 V bus-side power. Its fault-protected CAN front end is useful in installations where wiring faults, shorts, or transients are more likely than in a short bench harness.
Recomendado
Automotive Body Control Module
TCAN1051HGVD is applicable to body-control and chassis electronics that exchange CAN FD frames with sensors, actuators, and body modules. A 5 Mbps bus rate provides higher update bandwidth than the family’s 2 Mbps versions, while the -55 °C to 125 °C rating covers demanding temperature environments. The separate VIO input allows the digital interface to match the selected controller logic level. Automotive qualification status must be confirmed for the exact ordering variant before production release.
Recomendado
Robotics Motor Coordination Network
The TCAN1051HGVD can serve as the network interface for robot controllers coordinating drives, position feedback, and safety-related status. Operating at up to 5 Mbps reduces the time required to transfer motion commands and diagnostics across the CAN FD network. The VIO level-shifting function supports integration with 3.3 V controller logic while the CAN-side supply operates at 5 V. Fault protection adds resilience to field-wiring conditions, although cable routing, common-mode grounding, and termination still require careful design.
Recomendado
Building Control and HVAC Equipment
TCAN1051HGVD suits building-control equipment that uses CAN FD for HVAC controllers, room modules, sensors, and service interfaces. The extended 5 Mbps rate is useful when a controller aggregates diagnostics and sensor traffic across several bus participants. The SOIC package allows placement near a removable connector, while VIO supports host-side voltage flexibility. In long building wirings, maintain the recommended bus topology, use balanced routing, and place 120 Ω termination only at the two physical endpoints.
Recomendado
Embedded Test and Measurement Instrument
The TCAN1051HGVD is suitable for compact test equipment that communicates with DUTs or calibration systems over CAN FD. Its 5 Mbps capability shortens transfer time for waveform tables, configuration blocks, and diagnostic logs. The VIO input lets the transceiver connect to lower-voltage embedded controllers while preserving a 5 V CAN physical layer. For laboratory use, fault protection helps manage accidental bus shorts, although operators should still disable outputs and verify bus voltages before connecting equipment.
Recomendado
Portable Diagnostics and Service Tool
TCAN1051HGVD can be used in handheld or vehicle-service diagnostic adapters that exchange CAN FD data with an ECU or subsystem. The small SOIC footprint supports compact boards, and VIO enables connection to 3.3 V or other compatible host-interface voltage levels. A 5 Mbps link improves the time required to read identifiers, transfer data, and complete bus checks. The extended temperature rating supports ruggedized equipment, but enclosure grounding and protection against external cable transients remain system-level responsibilities.
Recomendado
Resumen de productos recomendados
Datos de referencia de ingeniería para TCAN1051HGVD — comparación, orientación de diseño e información de cumplimiento.
Guía de selección
Comparación con alternativas
| Parámetro | Este producto | TCAN1042HGV | TCAN1042HGD | TCAN1051HGD | TCAN1051HGVDRQ1 | ATA6564-GAQW1 |
|---|---|---|---|---|---|---|
| Package | 8-SOIC (D) | 8-SOIC (D) | 8-SOIC (D) | 8-SOIC (D) | 8-SOIC (D) | 8-SOIC |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Microchip Technology |
| I/O Level Shifting | Yes, VIO input | Yes, VIO version | No VIO suffix | No VIO suffix | Yes, VIO version | VIO behavior requires verification |
| Number of Pins | 8 pins | 8 pins | 8 pins | 8 pins | 8 pins | 8 pins |
Diferenciadores clave
- Matches the 5 Mbps data rate of the closest same-package Texas Instruments alternatives (frente a TCAN1042HGV)
- Uses the VIO-enabled TCAN1051HGV interface configuration (frente a TCAN1051HGD)
- Provides a documented automotive ordering path within the same core family (frente a TCAN1051HGVDRQ1)
- Cross-brand option retains the 8-pin SOIC format (frente a ATA6564-GAQW1)
Notas de diseño
Route CANH and CANL as a closely coupled differential pair from the TCAN1051HGVD to the bus connector. Avoid adding test pads or routing discontinuities that create impedance mismatches, and keep the pair away from switching nodes and high-current return paths. Place the transceiver close to the connector when possible, but position its ground connection and decoupling capacitors according to the manufacturer application circuit.
Treat VCC and VIO as separate supply domains. Decouple each supply at the device with the capacitance and placement specified in the manufacturer datasheet, and verify that VIO matches the RXD and control-interface voltage levels used by the host controller. The 4.5 V to 5.5 V VCC range must be respected independently of VIO; tying the two rails together is not a substitute for understanding the level-shifting architecture.
Do not add 120 Ω termination indiscriminately at the transceiver. A CAN network normally requires 120 Ω at each of its two physical endpoints, or two 60 Ω resistors per endpoint. Fault protection does not correct an incorrectly terminated network. Also check STB polarity and the meaning of normal and silent mode in the selected family member before firmware drives the control pin.
Plan the board footprint from the 8-SOIC datasheet drawing rather than from a generic SOIC library. Verify lead pitch, body width, solder-pad dimensions, pin numbering, and tube orientation during library creation. The exposed body is not a designated electrical pin, and the VIO net must remain distinguishable from VCC in both schematic capture and PCB layout.
Información de cumplimiento
The TCAN1051HGV family documentation identifies ISO 11898-2:2016 and ISO 11898-5:2007 physical-layer standards. RoHS, REACH, lead-free, halogen-free, conflict-minerals, and exact AEC-Q100 status were not established from the referenced product summary and must be confirmed in the manufacturer documentation for the exact ordering code.