TJA1042T/3/CM - 1 Mbps CAN Transceiver | NXP
N.º de pieza: TJA1042T/3/CM ✗ Fin de vidaTJA1042T/3/CM Descripción general
A CAN transceiver, also called a CAN physical-layer interface, converts logic-level signals from a CAN protocol controller into differential signals for the two-wire CAN bus. It also converts differential bus levels back into a controller-compatible receive signal. Within the hierarchy of interface ICs, the TJA1042T/3/CM implements the physical layer beneath the CAN protocol controller, while leaving message arbitration, framing, error handling, and protocol execution to the controller.
The TJA1042T/3/CM combines a 3.3 V or 5 V VIO interface with a high-speed CAN channel operating up to 1 Mbps. Standby mode reduces current consumption when the node does not need to transmit or receive. Bus wake-up capability permits a sleeping node to react to activity on the CAN bus, while passive behavior when unpowered helps define the state of the bus during shutdown or power-loss conditions.
The TJA1042T/3 version uses the VIO pin rather than the SPLIT function found on non-VIO TJA1042T and TJA1042CT variants. VIO allows the CAN controller-side interface voltage to be selected independently from the transceiver supply. This is particularly useful when the CAN controller operates at 3.3 V while the CAN physical layer uses a 5 V supply. The device supports differential transmit and receive and is designed for high-speed automotive CAN networks.
Typical applications include vehicle powertrain and body electronics, industrial automation equipment, building automation, robotics controllers, diagnostic systems, and distributed industrial sensors. Its standalone SOIC package also supports designs where the protocol controller and transceiver are separated for routing, isolation, or power-management reasons.
PCB design should preserve the CAN bus differential route and place termination only at the physical ends of the bus. Keep the CANL and CANH traces short, matched, and away from noisy switching nodes. Confirm VCC and VIO sequencing, respect the absolute maximum ratings, and verify wake-up and standby behavior against the system power-state requirements.
This page organizes the NXP transceiver’s key characteristics, sourcing information, drop-in replacement considerations, pin functions, and application guidance to support faster component evaluation and PCB design.
Alternativas directas para TJA1042T/3/CM — mismo encapsulado, compatible pin a pin. Se excluyen las piezas de otro encapsulado que requieren retrabajo de la PCB.
Variantes de esta serie
Modelos de la misma serie compatibles directamente con TJA1042T/3/CM (mismo factor de forma y huella) — difiere en Operating Temperature Range, Package, Product Type.
TCAN1042HD
✅ Sustitución directaConsulte el precio
Ver hoja de datos →TJA1042T/3/CM Especificaciones
| Product Type | High-speed CAN physical-layer transceiver |
| Maximum CAN Data Rate | 1 Mbit/s |
| Transceiver Supply Voltage VCC | 4.5 V to 5.5 V |
| Controller Interface Supply Voltage VIO | 2.8 V to 5.5 V |
| VIO Operating Modes | 3.3 V or 5 V microcontroller interface |
| CAN Bus Interface | 2-wire differential CAN bus |
| Operating Mode | High-speed mode |
| Power-Saving Mode | Standby mode with bus wake-up capability |
| Unpowered Behavior | Passive behavior |
| Interface Function | Differential transmit and receive |
| Microcontroller Interface | TXD and RXD signals |
| Encapsulado | 8-pin SOIC |
| Tipo de montaje | Surface mount |
| Rango de temperatura de funcionamiento | -40 °C to +125 °C |
| IEC 61000-4-2 ESD Protection | ±8 kV contact discharge and ±15 kV air discharge |
| Estado RoHS | Compliant |
| REACH Status | Compliant |
| Lead-Free Status | Lead-free |
Configuración de pines de TJA1042T/3/CM
| Pin 1 | TXD — Transmitter data input from the CAN controller |
| Pin 2 | GND — Ground connection |
| Pin 3 | VCC — Transceiver supply voltage input |
| Pin 4 | RXD — Receiver data output to the CAN controller |
| Pin 5 | VIO — Controller-side interface supply voltage input |
| Pin 6 | CANL — CAN bus low input and output |
| Pin 7 | CANH — CAN bus high input and output |
| Pin 8 | STB — Standby mode control input |
Aplicaciones típicas
TJA1042T/3/CM es adecuado para 6 aplicacións: Automotive Body Control Network, Industrial Automation Controller, Vehicle Diagnostic Gateway, Robotics Network Node, Building Automation Sensor Hub, Distributed Industrial Sensor Node.
Automotive Body Control Network
The TJA1042T/3/CM fits automotive body-control modules that require a 1 Mbit/s CAN physical layer while the host microcontroller operates from 3.3 V. Its VIO input range of 2.8 V to 5.5 V supports direct connection to a 3.3 V CAN controller, while VCC powers the bus-side interface from 5 V. Differential transmit and receive preserve noise immunity in a vehicle environment, and standby mode reduces consumption when the module is inactive.
Recomendado
Industrial Automation Controller
Industrial automation equipment can use the TJA1042T/3/CM to connect a controller to a field-level CAN bus carrying sensor commands, machine status, and diagnostic data. The transceiver supports communication rates up to 1 Mbit/s and separates the 2.8 V to 5.5 V controller-side VIO supply from the 5 V CAN side. Standby operation is useful for cyclic machines that spend time idle, while bus wake-up supports recovery from a low-power state when another node initiates traffic.
Recomendado
Vehicle Diagnostic Gateway
A vehicle diagnostic gateway benefits from the TJA1042T/3/CM because the device provides a high-speed differential CAN interface with a separate 3.3 V-compatible VIO rail. This allows a low-voltage gateway processor to communicate through a 5 V CAN physical layer without level-shifting every digital interface signal. Bus wake-up permits the gateway to activate when required, and passive unpowered behavior helps define the node state during ignition-off or supply-ramp conditions.
Recomendado
Robotics Network Node
The TJA1042T/3/CM is suitable for robot controllers that distribute actuator commands and collect position or fault information over a CAN bus. Its 1 Mbit/s capability supports responsive communication between motion-control and sensor nodes, while the VIO interface can operate directly with 3.3 V logic. Differential signaling improves noise immunity around motor drives and relays, although the PCB must maintain a controlled bus topology and place termination only at the two bus endpoints.
Recomendado
Building Automation Sensor Hub
A building-automation sensor hub can use the TJA1042T/3/CM to bridge a low-voltage controller to a 5 V CAN backbone operating at up to 1 Mbit/s. The separate VIO supply supports 3.3 V or 5 V host logic, and standby mode reduces consumption in rooms or zones that do not require continuous communication. Bus wake-up allows the hub to respond when another building controller starts a network transaction, supporting distributed HVAC, lighting, and access-control systems.
Recomendado
Distributed Industrial Sensor Node
Distributed sensor nodes can use the TJA1042T/3/CM when several remote measurement devices must exchange readings over a shared CAN network. The device combines a 1 Mbit/s physical layer with a 3.3 V-compatible VIO interface, reducing the need for external digital level translation. Standby mode lowers demand when measurements are not being reported, and wake-up capability allows a node to react to scheduled remote commands. Power and ground design should prevent conducted noise from coupling into CANL or CANH.
Recomendado
Resumen de productos recomendados
Datos de referencia de ingeniería para TJA1042T/3/CM — comparación, orientación de diseño e información de cumplimiento.
Guía de selección
Comparación con alternativas
| Parámetro | Este producto | TCAN1042H |
|---|---|---|
| Brand | NXP Semiconductors | Texas Instruments |
| Package | SOIC-8 | SOIC-8 |
| Maximum CAN Data Rate | 1 Mbit/s | 1 Mbit/s |
| Transceiver Supply Voltage VCC | 4.5 V to 5.5 V | 4.5 V to 5.5 V |
| Controller Interface Supply Voltage VIO | 2.8 V to 5.5 V | 3.0 V to 5.5 V |
| Minimum VIO | 2.8 V | 3.0 V |
| VCC Undervoltage Detection | 3.5 V | 3.8 V |
| Power-Saving Function | Standby mode with bus wake-up capability | Standby mode |
Diferenciadores clave
- Lower minimum VIO for controller-side interfacing (frente a TCAN1042H)
- Earlier VCC undervoltage detection (frente a TCAN1042H)
- Integrated bus wake-up and standby behavior (frente a TCAN1042H)
Notas de diseño
Route CANH and CANL as a close, length-matched differential pair and connect the 120 Ω termination only at the physical ends of the bus. Avoid stubs, test pads, and abrupt changes in layer geometry. Place the common-mode choke, termination network, and transceiver according to the NXP TJA1042 application guidance so that high-frequency CAN edges are not distorted by excessive trace or component parasitics.
Decouple VCC and VIO locally with the capacitance specified by the NXP manufacturer datasheet, and place the components at the associated pins rather than near the bus connector. Keep the 5 V CAN-side supply and 3.3 V or 5 V controller-side supply paths separate to prevent controller transients from coupling into the transceiver. Review startup, shutdown, and standby transitions to ensure no input is driven outside its supply limits.
Do not confuse pin 5 of the TJA1042T/3/CM with SPLIT. Pin 5 is VIO on this version, while SPLIT belongs to other TJA1042 family variants and is intended for split-termination circuitry. Confirm STB polarity and wake-up timing in the system controller. A pin-compatible-looking substitution can still change bus startup behavior even when its package and nominal data rate match.
Información de cumplimiento
The TJA1042 family is identified as RoHS and REACH compliant and lead-free. No specific AEC-Q100 qualification, halogen-free declaration, or conflict-minerals statement was identified for this exact order configuration.