TLV2453CN - Dual 6V RRIO Op Amp with Shutdown | TI
N.º de pieza: TLV2453CN ✓ ActivoTLV2453CN Descripción general
A rail-to-rail input/output operational amplifier is an analog amplifier whose input and output voltage ranges extend toward the positive and negative supply rails. Its place in the signal-chain hierarchy is amplifier IC, analog integrated circuit, semiconductor, and ultimately electronic component. The TLV2453 family serves general-purpose applications where low power, broad output swing, and shutdown control are more important than high bandwidth.
Key features include two amplifier channels, 220 kHz gain-bandwidth product, 23 uA per-channel quiescent current, rail-to-rail inputs and outputs, and a shutdown function. The amplifier also provides a typical 20 uV input offset voltage and approximately ±10 mA output drive capability. These characteristics make the device useful for battery-powered instrumentation, sensor interfaces, and low-energy signal-processing systems.
The 220 kHz gain-bandwidth product supports closed-loop operation at moderate signal frequencies while keeping quiescent power consumption low. Because the output can operate close to the supply rails, a 6 V system can retain useful signal range without a rail-to-rail output stage. Rail-to-rail input behavior improves common-mode range, although the input common-mode range, output swing limits, stability behavior, and noise characteristics should be checked against the manufacturer datasheet for the intended operating conditions.
Typical applications include portable sensor conditioning, low-current data acquisition, battery-powered monitoring, industrial signal interfaces, and embedded analog measurement systems. In each case, the 23 uA per-channel quiescent current reduces standing power demand, while the shutdown pin can disable the amplifier when the system does not require continuous operation.
Design around the 6 V maximum supply named for the device and verify input and output signal amplitudes before applying it to a precision measurement path. Keep sensitive input and feedback nodes away from switching nodes and noisy supply traces. When shutdown timing matters, account for the device's transition behavior and ensure the control signal remains within its specified voltage range.
This page organizes the TLV2453CN's electrical characteristics, package information, application guidance, design considerations, and verified substitute availability into an engineering-focused selection resource. It also distinguishes documented drop-in alternatives from parts that require a different footprint or a broader design review.
Alternativas directas para TLV2453CN — mismo encapsulado, compatible pin a pin. Se excluyen las piezas de otro encapsulado que requieren retrabajo de la PCB.
No hay alternativas directas disponibles para este producto.
Solicitar alternativasTLV2453CN Valores máximos y características eléctricas
| Number of Channels | 2 channels |
| Tensión de alimentación | 6 V |
| Gain-Bandwidth Product | 220 kHz |
| Corriente en reposo | 23 uA per channel |
| Input Common-Mode Range | Rail-to-rail |
| Output Swing | Rail-to-rail |
| Input Offset Voltage | 20 uV typical |
| Output Drive Capability | ±10 mA |
| Shutdown Function | Yes |
| Encapsulado | 14-PDIP |
| Recuento de pines | 14 pins |
| Tipo de montaje | Through-hole |
| Product Classification | Standard general-purpose amplifier |
Guía de configuración de pines de TLV2453CN 14-pdip
Configuración de pines para TLV2453CN (encapsulado 14-pdip). Este componente analógico presenta pines de entrada, salida y alimentación. Consulte la hoja de datos del fabricante para conocer las configuraciones de los pines de ajuste de offset, compensación y habilitación. Ideal para circuitos de acondicionamiento de señal y amplificadores.
No hay datos detallados de patillaje disponibles para TLV2453CN.
Consulte la hoja de datos para ver la configuración completa de patillas.
Aplicaciones típicas
TLV2453CN es adecuado para 6 aplicacións: Battery-Powered Sensor Conditioning, Portable Data Acquisition, Industrial Instrumentation, Low-Power Monitoring Systems, Analog Signal Buffering, Low-Energy Control Interfaces.
Battery-Powered Sensor Conditioning
The TLV2453CN is well suited to conditioning signals from low-power sensors because each channel draws 23 uA of quiescent current at the device's 6 V operating rating. Rail-to-rail inputs help accommodate sensor outputs that move close to either supply rail, while rail-to-rail outputs increase the usable span at the following ADC or controller input. Place the amplifier close to the sensor connector, keep feedback traces short, and use the shutdown control when continuous monitoring is unnecessary. Because sensor bias current and output loading can dominate the power budget, verify the complete signal-chain current before estimating battery life.
Portable Data Acquisition
A portable acquisition system can use both TLV2453CN channels to amplify sensor or transducer signals before conversion to digital data. The 220 kHz gain-bandwidth product provides useful bandwidth for many slowly varying industrial and portable measurements, while the low 23 uA per-channel quiescent current helps limit standby demand. Rail-to-rail input and output stages can improve signal utilization in compact systems operating from a low-voltage source. Apply the manufacturer datasheet limits to input voltage, output swing, common-mode range, and capacitive loading, and include anti-alias filtering after the amplifier when the sampled bandwidth requires it.
Industrial Instrumentation
The TLV2453CN can serve as a general-purpose front-end amplifier in industrial instrumentation that requires a 6 V supply, rail-to-rail signal handling, and two amplifier channels in one through-hole package. Its 220 kHz gain-bandwidth product is appropriate for many process-control and diagnostic signals rather than high-frequency communications paths. The shutdown function can isolate the analog section during idle intervals, but the control sequence should be coordinated with downstream converters and sensors. Maintain short analog traces, use a quiet reference or supply arrangement where needed, and confirm input impedance and offset behavior for the particular sensor source.
Low-Power Monitoring Systems
The TLV2453CN fits monitoring systems that periodically measure an analog condition and then enter a reduced-power state. Two channels can handle related inputs, such as a sensor signal and a temperature or threshold reference, while the 23 uA per-channel quiescent current limits the continuous load. Rail-to-rail operation is useful when the monitored signal occupies much of the available 6 V supply range. For duty-cycled designs, evaluate startup, shutdown timing, and input settling at the required sampling rate. Stable reference components and low-leakage PCB surfaces are especially important when the amplifier is expected to resolve small signals between measurement cycles.
Analog Signal Buffering
When a sensor or divider produces a signal that cannot directly drive the next circuit, the TLV2453CN can provide voltage buffering and level shifting within its rail-to-rail output range. The 220 kHz gain-bandwidth product allows operation as a unity-gain buffer at signal frequencies well below the amplifier's gain-bandwidth limit, subject to the stability and loading requirements in the manufacturer datasheet. A typical 20 uV input offset voltage can also be useful in moderate-precision buffering, although long feedback traces increase susceptibility to noise and coupling. Connect the unused amplifier channel according to the datasheet guidance rather than allowing an undefined input state.
Low-Energy Control Interfaces
The TLV2453CN can amplify control, feedback, or sensor-derived voltages in compact embedded systems that operate from a 6 V rail. Its dual-channel configuration reduces the number of amplifier packages needed when two related functions must be handled, while the shutdown input supports activity-based power management. The approximately ±10 mA output-drive capability is suitable for many high-impedance loads but does not imply heavy capacitive-load capability. Keep output paths short, check the load's DC and capacitive requirements, and design the shutdown control so it cannot float. This prevents unintended operation or excessive current in low-energy systems.
Datos de referencia de ingeniería para TLV2453CN — comparación, orientación de diseño e información de cumplimiento.
Guía de selección
Comparación con alternativas
| Parámetro | Este producto |
|---|---|
| Brand | Texas Instruments |
| Package | 14-PDIP |
| Number of Channels | 2 |
| Supply Voltage | 6 V |
| Gain-Bandwidth Product | 220 kHz |
| Quiescent Current | 23 uA per channel |
| Input Offset Voltage | 20 uV typical |
| Output Drive Capability | ±10 mA |
| Input and Output Swing | Rail-to-rail |
| Shutdown Function | Yes |
Diferenciadores clave
- Low-power dual-channel integration (frente a TLV2453CN versus a discrete single-channel implementation)
- Shutdown support (frente a TLV2453CN versus a conventional amplifier without shutdown)
- Rail-to-rail signal range (frente a TLV2453CN versus a conventional non-RRIO amplifier)
Notas de diseño
Calculate the complete power budget from the 6 V supply, sensor current, load current, and the TLV2453CN's 23 uA per-channel quiescent current. If the amplifier is disabled during inactive intervals, confirm the shutdown-control logic and account for transitions between operating states. Do not treat the 23 uA figure as total system consumption because bias current, output drive, and shutdown behavior depend on the actual operating condition.
Route sensitive amplifier inputs and high-impedance feedback connections away from switching-regulator, relay, and digital-clock traces. Keep the input and feedback paths short, connect the decoupling capacitor directly to the supply pins, and use a quiet ground-return path. The rail-to-rail input stage can reduce headroom limitations, but it does not remove susceptibility to parasitic pickup or unstable reference nodes.
Verify that input and output voltages remain inside the manufacturer-defined operating limits at the actual supply voltage; rail-to-rail labeling does not guarantee unlimited input range. Avoid leaving an unused amplifier input floating, and follow the datasheet recommendation for that pin. Also check capacitive loading against the stability guidance before driving long cables, ADC sampling networks, or other capacitive inputs directly from the amplifier.
Información de cumplimiento
Compliance attributes are not identified on the product information summarized for this device. Confirm current material and environmental declarations for the ordered TLV2453CN configuration with the manufacturer.