محصولات (44,000+)

INA125TDA2 - 10000:1 Instrumentation Amplifier | Texas Instruments
INA125TDA2

INA125TDA2 - 10000:1 Instrumentation Amplifier | Texas Instruments

The Texas Instruments INA125TDA2 is a single-circuit instrumentation amplifier with an integrated precision voltage reference, a maximum voltage gain of 10000, and a 17-terminal bare-die package. It is designed for precision measurement systems that require differential signal amplification, high common-mode rejection, and adjustable gain. The device also provides a nominal gain-bandwidth product of 0.15 MHz and maximum nonlinearity of 0.004%. An instrumentation amplifier is a precision analog amplifier optimized for measuring small differential signals superimposed on a larger common-mode voltage. Its internal architecture is designed to provide high input impedance, controlled differential gain, and strong rejection of common-mode interference. This makes instrumentation amplifiers distinct from general-purpose operational amplifiers and places them within the amplifier IC hierarchy used for sensor conditioning, bridge excitation, and high-precision signal acquisition. Key characteristics include a maximum voltage gain of 10000, minimum common-mode rejection ratio of 107 dB, nominal bandwidth of 0.15 MHz, and maximum nonlinearity of 0.004%. The integrated precision voltage reference supports applications that need a controlled reference in addition to differential amplification. The single-circuit implementation also reduces the number of separate amplifiers needed for one measurement channel. The INA125 architecture supports programmable gain through external components and is suited to analog front ends where signal gain must be selected according to sensor output and input range. Its high common-mode rejection is valuable when a low-level sensor signal is measured in the presence of system-level interference. Because the INA125TDA2 is supplied as bare die, final package options, pin assignments, bonding details, and production integration requirements must be confirmed directly with Texas Instruments before a PCB or multichip-module design is released. Typical applications include bridge-based pressure and force measurement, precision current sensing, laboratory instrumentation, industrial sensor interfaces, and medical monitoring circuits. In a bridge circuit, the device can amplify the small differential bridge voltage while rejecting much of the common excitation voltage and its associated noise. The integrated reference can also support excitation or signal-conditioning systems that require a stable, controlled reference. The most important design consideration is package integration because INA125TDA2 is a die rather than a standard molded package. Designers should obtain the manufacturer’s die-product documentation and bonding information before assigning pads, defining the footprint, or estimating assembly yield. Input filtering, reference bypassing, gain-setting resistors, and output settling should also be evaluated against the selected gain and measurement bandwidth. This page combines the identified electrical characteristics with application guidance, design considerations, sourcing information, and a transparent assessment of replacement options. The absence of confirmed pin-to-pin alternatives is itself important because a functionally similar amplifier in a different package is not a drop-in replacement.

RFQ تماس
INA125U - Precision Bridge Amplifier, 10V Ref | Texas Instruments
INA125U

INA125U - Precision Bridge Amplifier, 10V Ref | Texas Instruments

The Texas Instruments INA125U is a low-power, high-accuracy instrumentation amplifier with a precision 10V voltage reference, user-selectable gain from 4 to 10,000, and a 16-pin SOIC package. It combines bridge excitation and differential-input amplification on one integrated circuit, making it suitable for strain-gauge, pressure-transducer, and other bridge-sensor signal chains. An instrumentation amplifier is a specialized differential amplifier designed for sensors whose useful output is small and appears across two input terminals. Its internal architecture provides high input impedance, accurate differential gain, and strong common-mode rejection. The INA125 adds a precision reference output, allowing a bridge circuit to be excited and its output measured relative to a stable midpoint. The INA125U offers a 2.7V to 36V supply range, low 460µA quiescent current, maximum 250µV input offset voltage, maximum 2µV/°C offset drift, and a sleep mode. A single external resistor sets the gain, while the integrated amplifier can provide 150kHz bandwidth according to the retrieved product data. These features balance precision, power consumption, and measurement speed for portable and industrial instrumentation. Electrically, the device is intended for bridge outputs and other low-level differential sources. Input common-mode range, reference accuracy, gain error, and maximum input voltage must be checked against the actual bridge excitation and sensor output. The SOIC package also requires careful attention to ground return paths and supply decoupling when low-level signals are measured. Typical uses include quarter-bridge and full-bridge strain sensors, load-cell front ends, pressure and force measurement, biomedical instrumentation, industrial process controls, and precision data-acquisition systems. The 10V reference can simplify excitation when the sensor and measurement chain require a defined bridge supply. The most important design consideration is preserving common-mode and differential signal integrity. Place input and reference grounding deliberately, use low-noise supply bypass capacitors, and verify that the selected gain resistor stays within its recommended range. This page combines verified manufacturer and distributor information with practical application guidance and explicit data gaps rather than estimating unprovided specifications.

RFQ تماس
INA125U/2K5 - Low-Power Precision Instrumentation Amplifier with 2.5V Reference
INA125U/2K5

INA125U/2K5 - Low-Power Precision Instrumentation Amplifier with 2.5V Reference

The Texas Instruments INA125U/2K5 is a low-power, high-accuracy instrumentation amplifier with an integrated precision voltage reference, delivered in a 16-pin SOIC package. It provides complete bridge excitation and precision differential-input amplification on a single integrated circuit, with gain set from 4 V/V to 10,000 V/V by one external resistor. Key headline figures are a 2.7 V to 36 V supply range (±18 V maximum total supply), an input bandwidth of 0.15 MHz, a 100 dB CMRR and 38 nV/√Hz input noise at 1 kHz, all in a 16-lead SOIC. An instrumentation amplifier is a differential-input amplifier optimized for measuring small signals buried in noise and common-mode interference. The category hierarchy runs instrumentation amplifier -> differential amplifier -> amplifier IC -> integrated circuit -> semiconductor. Unlike a discrete op-amp difference stage, an INA offers high input impedance, matched resistors, excellent common-mode rejection and a single-gain-set resistor, which is why it dominates strain-gauge, bridge and ratiometric sensor front ends. Key features include a 50 uV maximum input offset voltage, a 2 uV/°C input offset voltage temperature coefficient, a 460 uA typical supply current for low-power designs, a 2 V/µs slew rate, and 60 µs settling time. The internal reference supplies a stable excitation voltage for bridge circuits, and an enable/shutdown pin supports power management. Overvoltage protection guards inputs during industrial transients. Technically, the device uses a three-op-amp topology with laser-trimmed internal feedback resistors, so gain accuracy depends only on the external gain resistor. The on-board precision reference makes ratiometric conversion with an ADC possible without a second supply, and the reference can also serve as an external excitation source. The single external gain resistor keeps the calibration chain short, which supports the 0.075% gain error class of the device. Typical applications include strain-gauge and load-cell front ends, isolated transmitter analog sections, bridge-powered sensor modules, medical monitoring instrumentation, and 4-20 mA loop signal conditioning where the reference eliminates a separate excitation supply. When designing around the INA125U/2K5, keep the gain resistor close to the RG pin and use the recommended supply bypassing. Because it is a linear amplifier with a wide supply range, excessive headroom at high gain costs power and heat; choose the smallest gain that meets the sensitivity target. This page consolidates distributor availability, drop-in same-family alternatives, parameter-by-parameter comparison, and practical layout notes that are not collected in a single place in the manufacturer datasheet.

RFQ تماس
INA125UA - Precision Bridge Instrumentation Amplifier | TI
INA125UA

INA125UA - Precision Bridge Instrumentation Amplifier | TI

The Texas Instruments INA125UA is a low-power, high-accuracy instrumentation amplifier with an integrated precision voltage reference, one differential input channel, and a 16-pin SOIC package. A single external resistor sets the gain from 4 to 10,000 V/V, while the integrated bridge excitation and reference circuitry support complete sensor-conditioning solutions in one IC. An instrumentation amplifier is a specialized analog signal-conditioning IC designed to amplify small differential voltages while rejecting common-mode interference. Its functional hierarchy is instrumentation amplifier, differential amplifier, analog front end, and signal-conditioning IC. This device is particularly useful when a sensor produces a small differential output and the measurement environment contains noise, ground-potential differences, or substantial common-mode voltage. The INA125UA combines differential-input amplification, adjustable gain, bridge excitation, and a precision voltage reference in one package. Its gain range of 4 to 10,000 V/V allows the same device family to serve strain-gauge, pressure-sensor, and resistive-bridge systems. The single-resistor gain-setting arrangement simplifies calibration and reduces the number of external components required for many precision measurement circuits. The device is laser-trimmed for accuracy, and the family operates across a supply range of 2.7 V to 36 V. The INA125UA ordering option is supplied in a 16-pin SOIC package for surface-mount assembly. The integrated reference can support excitation or output-referencing requirements where an external precision reference would otherwise increase component count and introduce another error source. Typical uses include strain-gauge load cells, resistive pressure and temperature sensors, current-shunt instrumentation, industrial process monitoring, and precision laboratory measurement systems. It is especially appropriate when differential signal integrity, adjustable gain, and integrated bridge excitation are needed within one analog front end. The wide supply range also allows operation from low-voltage portable systems through higher-voltage industrial measurement equipment. Designers should follow the TI datasheet for the exact gain-resistor equation, reference-output behavior, input and output range, supply decoupling, and common-mode limitations. Place bypass capacitors close to the supply pins, keep sensitive differential routes compact and symmetric, and verify that transducer excitation, input common-mode voltage, output swing, and gain remain within their permitted operating limits. This page organizes the INA125UA specifications, pin package, application guidance, comparison parameters, and drop-in alternatives. It also identifies the engineering trade-offs between same-footprint family members and provides sourcing workflows for price, availability, and lead-time requests.

RFQ تماس
INA126P - 36V MicroPower Precision INA | Texas Instruments
INA126P

INA126P - 36V MicroPower Precision INA | Texas Instruments

The Texas Instruments INA126P is a precision micropower instrumentation amplifier rated for a 36 V maximum supply, with 175 µA quiescent current, 250 µV input offset voltage, and gain values set by an external resistor. It is supplied in an 8-pin PDIP package for through-hole industrial, portable, and measurement-instrumentation designs. An instrumentation amplifier is a differential analog-front-end IC that amplifies the voltage difference between two inputs while rejecting common-mode interference. INA126 belongs to the instrumentation-amplifier hierarchy within operational amplifiers and analog signal-chain ICs. Its two-op-amp architecture supports accurate, low-noise acquisition from sensors, bridges, and low-level transducers, especially where power consumption and input precision are important. The verified features include 250 µV offset, 175 µA typical quiescent current, and operation from ±1.35 V to ±18 V, corresponding to a stated 36 V maximum supply condition. The INA126 family also provides programmable gains of 1, 10, 100, or 1000 through the external gain resistor. These values make it suitable for battery-powered instrumentation, industrial measurement, portable diagnostics, and sensor interfaces where common-mode rejection and low bias current are more valuable than wide bandwidth. The device uses a two-op-amp internal architecture rather than a three-op-amp topology, helping keep power consumption low. Because the gain depends on the external resistor and its matching, PCB resistor placement, source impedance balance, input filtering, grounding, and reference-connection practices directly influence accuracy. The 8-pin PDIP package is mechanically straightforward for through-hole assembly but requires adequate lead spacing and clean soldering practice. Typical applications include bridge-based pressure and load measurement, low-level sensor conditioning, portable medical or industrial instrumentation, battery-operated data acquisition, and differential signal acquisition where a precision offset and low supply current are required. For single-supply systems, the output-reference arrangement must be designed to keep the output within the input and output common-mode limits. The principal design trade-off is the relatively modest micropower-focused feature set versus higher-bandwidth or lower-noise instrumentation amplifiers. Confirm supply voltage, input range, gain resistor, output swing, reference connection, and common-mode limits against the manufacturer datasheet before committing a PCB design. This page combines verified manufacturer and distributor information with design guidance, selection criteria, and same-package comparison context for engineers evaluating the INA126P.

RFQ تماس
INA126PA - 36V Micropower Instrumentation Amplifier | TI
INA126PA

INA126PA - 36V Micropower Instrumentation Amplifier | TI

The Texas Instruments INA126PA is a single-channel, precision micropower instrumentation amplifier with a 36 V maximum supply rating, 250 µV input offset voltage, 175 µA quiescent current per channel, and an 8-pin PDIP package. It is designed to acquire accurate, low-noise differential signals while consuming very little power. The two-operating-amplifier architecture supports common-mode rejection and differential signal conditioning in compact, portable, and industrial instrumentation systems. An instrumentation amplifier is a specialized amplifier category used to amplify the difference between two input signals while rejecting common-mode voltage. Within the amplifier hierarchy, an instrumentation amplifier is a precision analog amplifier, while an operational amplifier is a more general-purpose building block. The INA126PA belongs to the micro-power instrumentation-amplifier family and combines differential input measurement, adjustable gain, and low bias current in one integrated circuit. The principal advantages are low power consumption, low offset voltage, a wide operating-supply range of ±1.35 V to ±18 V, and operation from a single supply down to 2.7 V. According to the manufacturer datasheet, the device uses 175 µA per channel and provides a gain adjustment range of 1 V/V to 1000 V/V. These characteristics suit battery-powered and portable measurement systems where amplifier power can materially affect available operating time. The INA126PA uses a two-operating-amplifier architecture for accurate, low-noise differential-signal acquisition. Its instrumentation-amplifier function is useful when the wanted signal is smaller than the voltage shared by both input nodes. The low 175 µA quiescent current is particularly important in portable instrumentation and data-acquisition systems, while the 250 µV offset specification supports precision measurement of small differential voltages. Typical applications include portable sensor acquisition, industrial process measurement, battery-operated diagnostic equipment, low-current transducers, and differential voltage sensing. In each case, the device can condition a low-level differential input before it reaches an ADC or another signal-processing stage. Its single- and dual-supply flexibility allows it to be used with compact analog systems operating from low-voltage sources as well as higher-voltage industrial rails. Designers should verify the exact gain-setting resistor against the manufacturer gain table and preserve the input and reference-pin arrangements shown in the datasheet. The reference input should be connected to a defined low-impedance voltage, and unused inputs must not be allowed to float. PCB layout should keep the gain-setting resistor close to the device to minimize added noise and instability in sensitive measurement circuits. This product page consolidates verified manufacturer and distributor information, lifecycle guidance, package details, replacement analysis, and practical design guidance. It also distinguishes verified drop-in candidates from changes requiring a different package, helping engineers avoid confusing functional equivalence with literal PCB-level replaceability.

RFQ تماس
INA126U - 36V Micropower Instrumentation Amp | Texas Instruments
INA126U

INA126U - 36V Micropower Instrumentation Amp | Texas Instruments

The Texas Instruments INA126U is a single-circuit micropower precision instrumentation amplifier rated for a 36 V total supply, with 175 µA quiescent current per channel, 250 µV offset, and an 8-pin SOIC package. Its differential-input architecture supports accurate, low-noise signal acquisition where common-mode interference, source impedance mismatch, and power consumption must all be controlled. An instrumentation amplifier is a specialized amplifier and the final member of the signal-chain hierarchy: sensor output → differential input → instrumentation amplifier → ADC or measurement system. Unlike a general-purpose operational amplifier, an instrumentation amplifier internally supports high input impedance and accurate differential gain, reducing errors when both inputs originate from balanced sensors, resistive bridges, or shunt measurements. The INA126 family uses a two-op-amp architecture optimized for precision and micropower operation. Verified headline features include a 36 V maximum supply, 175 µA per-channel quiescent current, and 250 µV offset. The manufacturer describes the device for accurate, low-noise differential-signal acquisition across a wide operating voltage range of ±1.35 V to ±18 V. These properties suit portable instruments and low-power acquisition systems where battery energy is limited but input-referred accuracy remains important. The single amplifier in the INA126U also avoids the extra power and board area associated with an unnecessary dual channel. The INA126U can be configured through an external gain-setting resistor. Because its instrumentation-amplifier architecture rejects common-mode signals before they reach the output, it is particularly useful when the wanted differential signal is much smaller than the voltage shared by both inputs. Designers must still verify input and output common-mode limits, maximum differential input voltage, gain-bandwidth behavior, resistor tolerance, output swing, and the sensor output range for the intended supply voltage. Precision performance ultimately depends on resistor matching and careful grounding as well as the amplifier itself. Typical uses include battery-powered sensor interfaces, portable measurement instruments, current-shunt amplifiers, bridge-signal conditioning, and low-power data-acquisition front ends. The 175 µA per-channel quiescent current is particularly useful where idle current directly affects battery life. The 250 µV offset specification gives designers a defined input-referred error reference, while the 36 V supply capability supports higher-voltage industrial systems when the individual input and output ranges are observed. For PCB implementation, keep the external gain resistor close to the gain-setting pins, use a stable low-noise reference plane, and place input-protection capacitance only after checking its effect on bandwidth and transient response. Avoid long parallel input traces, maintain symmetric routing where practical, and provide local supply bypassing. Verify common-mode headroom at worst-case sensor voltage and load current rather than relying only on nominal supply conditions. This page combines verified manufacturer facts, distributor pricing, same-package alternatives, and application-oriented design guidance. It also distinguishes documented values from parameters requiring confirmation from the complete manufacturer datasheet, helping engineers move from component selection to a defensible low-power sensor-board design.

RFQ تماس
INA126U/2K5 - 36V MicroPower Instrumentation Amplifier | Texas Instruments
INA126U/2K5

INA126U/2K5 - 36V MicroPower Instrumentation Amplifier | Texas Instruments

Texas Instruments INA126U/2K5 is a precision, micropower instrumentation amplifier with a 36 V maximum supply voltage, 175 µA quiescent current, and 250 µV input offset voltage, supplied in an 8-pin SOIC package. Designed for low-level differential-signal acquisition, it combines a two-op-amp architecture with high input impedance and low power consumption for portable instrumentation, industrial measurement, and sensor-interface applications. An instrumentation amplifier is a specialized amplifier that measures the voltage difference between two inputs while rejecting common-mode voltage. Its place in the signal-chain hierarchy is sensor front end → instrumentation amplifier → precision analog signal chain. Unlike a general-purpose operational amplifier, an instrumentation amplifier provides purpose-built differential input handling and high common-mode rejection for bridges, sensors, and measurement systems. The INA126 family provides low quiescent current of 175 µA per channel and supports supply voltages from ±1.35 V to ±18 V. Its 250 µV offset specification supports accurate measurement of small differential signals, while the wide 36 V total supply range permits operation from compact dual supplies or a single supply when the signal and reference levels are compatible with the device architecture. The INA126 uses a two-op-amp instrumentation-amplifier topology rather than a three-op-amp configuration. This reduces circuit complexity and can reduce board area, while preserving the differential-input behavior required by precision measurement systems. The gain arrangement associated with the /2K5 ordering option distinguishes this version from other INA126 gain and package configurations, so the full ordering information should be checked before substituting a part in an existing design. Typical uses include bridge-transducer excitation and readout, battery-powered sensor acquisition, current measurement, industrial process monitoring, and portable medical or test equipment. Low quiescent current is particularly valuable when the amplifier must remain active while the overall instrument consumes little power. The 36 V supply capability also supports higher-voltage industrial measurement systems when appropriate input common-mode and output-range conditions are met. When laying out the circuit, use the pin-description table in the manufacturer datasheet for all connections and preserve the reference and supply decoupling arrangement shown by Texas Instruments. Input filtering, resistor placement, and guarding can materially affect accuracy in high-impedance sensor nodes. The output-reference connection should also be treated as part of the measurement system because its voltage influences the output level and can be used for bipolar-signal offsetting. This page combines the manufacturer product description, ordering distinctions, cross-reference findings, comparison guidance, and practical implementation advice. It highlights where the INA126U/2K5 fits in low-power precision acquisition and identifies the parameter checks engineers should complete before approving a replacement or redesign.

RFQ تماس
INA126UA - 36V Precision MicroPower Instrumentation Amplifier | TI
INA126UA

INA126UA - 36V Precision MicroPower Instrumentation Amplifier | TI

The Texas Instruments INA126UA is a single-channel precision instrumentation amplifier with a 36 V maximum supply, 175 µA quiescent current per channel, 250 µV input offset voltage, and an 8-pin SOIC package. It is designed for accurate, low-noise differential-signal acquisition where low power consumption and high common-mode rejection are important. An instrumentation amplifier is a differential-input amplifier optimized for measuring small signals embedded in larger common-mode voltages. Its internal gain stage rejects common-mode noise and converts the differential difference between two inputs into a single-ended output. The INA126 belongs to the broader hierarchy of instrumentation amplifier, precision amplifier, analog signal-conditioning IC, and semiconductor. The INA126UA uses a two-op-amp architecture with external gain-setting resistors. Its precision input offset voltage supports accurate bridge, current-sense, and sensor measurements, while the 175 µA per channel quiescent current suits battery-powered and portable equipment. The 250 µV input offset specification is particularly useful when the measured differential signal is small relative to the allowed error. The device supports supply voltages from 2.7 V to 36 V total, corresponding to the documented operating range of ±1.35 V to ±18 V. Its 200 kHz bandwidth suits relatively slow precision measurements rather than high-speed waveform capture. The two-op-amp topology balances low noise and low quiescent current with a practical gain-setting arrangement using an external resistor. Typical uses include strain-gauge and RTD signal conditioning, low-side current measurement, bridge excitation, biomedical instrumentation, and portable sensor acquisition. For bridge-based sensors, the instrumentation amplifier rejects ground offsets and common-mode interference before the signal reaches an ADC. For battery-powered systems, the 175 µA per channel current helps limit standby consumption. Choose the INA126UA when the design requires a precision single-channel amplifier with an 8-pin SOIC footprint and very low quiescent current. Verify the selected gain, output swing, supply voltage, bandwidth, and output-reference arrangement against the manufacturer datasheet. Input and reference pins should be routed away from switching nodes and noisy return currents. This page combines device specifications, verified drop-in alternatives, application guidance, package details, and selection trade-offs to help engineers evaluate the INA126UA before circuit implementation.

RFQ تماس
INA126UAG4 - 36V Precision Instrumentation Amplifier | TI
INA126UAG4

INA126UAG4 - 36V Precision Instrumentation Amplifier | TI

The Texas Instruments INA126UAG4 is a precision, micropower instrumentation amplifier designed for accurate differential signal acquisition. Its three headline characteristics are a 36 V maximum supply capability, 175 µA typical quiescent current per channel, and 250 µV input offset voltage. The device is packaged in an 8-pin SOIC, allowing it to fit compact industrial, instrumentation, and low-power signal-conditioning designs. An instrumentation amplifier is a specialized amplifier optimized for measuring small differential signals superimposed on a larger common-mode voltage. Its internal two-op-amp architecture provides accurate differential gain while rejecting common-mode interference. In the broader hierarchy, an instrumentation amplifier belongs to the amplifier IC category and provides a dedicated function for sensor front ends, where preserving signal integrity is more important than simply amplifying a single-ended voltage. The INA126 family combines precision offset performance with very low power consumption. Its 175 µA per channel quiescent current supports battery-powered and portable equipment, while the 36 V supply range provides headroom for industrial measurement systems. The manufacturer identifies the device as a precision instrumentation amplifier for accurate, low-noise differential signal acquisition, with nominal gain set by an external resistor. A two-op-amp architecture is used to establish the differential gain and reject common-mode voltage. An external gain-setting resistor lets the circuit adapt across a broad range of sensor sensitivities, while an accessible reference path can support bipolar or offset output systems. Because the INA126UAG4 is a single-channel device, systems requiring simultaneous differential measurements should use a dual-channel implementation or multiple matched devices. Typical uses include bridge and strain-gauge signal conditioning, pressure and temperature sensor interfaces, current-shunt measurements, and low-power industrial data acquisition. The 200 kHz bandwidth identified for the INA126 family is suitable for many precision rather than high-speed signal chains. It is particularly useful when slow-changing sensor outputs must be measured accurately with limited supply current. Designers should place input and gain-setting components close to the device, follow the manufacturer reference-circuit topology, and verify input common-mode and output-swing limits at the intended supply voltage. Input filtering should reject out-of-band interference without unnecessarily reducing bandwidth. Because gain is set externally, resistor tolerance and parasitic resistance directly affect gain accuracy and should be included in the system error budget. This page combines manufacturer specifications, sourcing guidance, compatible-family comparisons, and practical design considerations to support faster component selection. It also identifies where application-specific verification is required before a precision measurement design is released for production.

RFQ تماس
INA128HD - 130dB CMRR Low-Power Instrumentation Amplifier | TI
INA128HD

INA128HD - 130dB CMRR Low-Power Instrumentation Amplifier | TI

The Texas Instruments INA128HD is a precision, low-power instrumentation amplifier with 130 dB CMRR, 700 µA typical quiescent current, and a 1.3 MHz gain-bandwidth product, housed in an 8-pin SOIC package. It accepts input protection to ±40 V, supports supply voltages up to ±18 V, and uses one external resistor to set gain from 1 to 10,000. The INA128HD is the high-temperature member of the INA128-HT family and is intended for precision bridge, sensor, and low-level differential-signal measurement. An instrumentation amplifier is a specialized amplifier that amplifies the voltage difference between two inputs while rejecting signals common to both inputs. This three-operational-amplifier architecture belongs to the broader measurement-amplifier and analog-signal-conditioning hierarchy. It is especially useful when a small sensor voltage is mixed with a larger common-mode voltage and the measurement requires high input impedance, accurate differential gain, and low output offset. Key characteristics include 25 µV typical offset voltage, 93 dB minimum CMRR at gain settings of 100 or higher, a 4 V/µs slew rate, and a gain equation based on a 49.4 kΩ gain-setting resistor. Input bias current is listed as 50 nA typical. These features allow the INA128HD to preserve small differential signals while rejecting power-supply ripple, ground offsets, and other common-mode disturbances. The INA128 uses a current-feedback input stage to maintain usable bandwidth at higher closed-loop gains. A single resistor between the gain-setting terminals establishes the desired gain, while the internal amplifier stages provide differential sensing and single-ended output. The manufacturer describes the INA128-HT as a laser-trimmed design with low offset and high CMRR, making it appropriate for precision analog front ends where gain accuracy and signal purity are more important than minimum cost. Typical uses include Wheatstone bridge sensing, pressure and force measurement, biomedical instrumentation, industrial sensor acquisition, and low-level differential receiver circuits. The 8-pin SOIC package is also practical for high-density analog boards, although the specified operating temperature range and total input error should be checked against the mechanical and environmental requirements of the target equipment. For PCB design, place the gain resistor close to pins 1 and 8 to minimize parasitic resistance and instability. Keep input and reference-node routing away from switching nodes and high-current return paths. Check the maximum differential input voltage, common-mode range, supply limits, and output swing in the manufacturer datasheet before finalizing the sensor interface. This product page combines manufacturer specifications, sourcing guidance, application analysis, and same-package drop-in comparisons. It also highlights practical PCB and signal-integrity considerations that help engineers evaluate the INA128HD beyond a basic parametric component listing.

RFQ تماس
INA128P - 130dB CMRR Precision INA | Texas Instruments
INA128P

INA128P - 130dB CMRR Precision INA | Texas Instruments

The Texas Instruments INA128P is a precision, low-power instrumentation amplifier with 130 dB CMRR, a 700 µA quiescent current, and an 8-pin PDIP package. It provides 50 µV maximum offset voltage, 0.5 µV/°C maximum offset drift, 5 nA maximum input bias current, and 1.3 MHz bandwidth. The device accepts supply voltages from ±2.25 V to ±18 V and supports input protection to ±40 V. An instrumentation amplifier is a specialized amplifier-IC category designed to amplify small differential sensor signals while rejecting common-mode interference. INA128P belongs to the instrumentation-amplifier hierarchy, which also includes differential amplifiers and analog front ends for measurement systems. Its three-op-amp architecture provides accurate differential gain, high input impedance, and flexible gain selection with an external resistor. Key features include a low offset voltage of 50 µV maximum and low offset drift of 0.5 µV/°C maximum. The 130 dB CMRR figure minimizes errors when a sensor signal is small relative to its common-mode voltage. Current-feedback input circuitry preserves bandwidth at higher gain, including 200 kHz bandwidth at a gain of 100. Input bias current remains low at 5 nA maximum, which is valuable for high-impedance sensors. The INA128P uses a versatile three-op-amp instrumentation-amplifier architecture and is available in an 8-pin plastic DIP package. Its ±2.25 V to ±18 V supply range supports dual-supply analog systems and higher-voltage industrial interfaces. The specified operating temperature range is -40 °C to +85 °C. The low 700 µA quiescent current helps reduce power consumption in portable and low-power measurement equipment. Typical applications include bridge and strain-gauge signal conditioning, current measurement, biomedical instrumentation, industrial sensor interfaces, precision data acquisition, and laboratory measurement systems. The device is particularly suitable when common-mode rejection and low offset are more important than very high bandwidth. The manufacturer datasheet also identifies current-feedback input circuitry for improved high-gain bandwidth. When designing around INA128P, choose the external gain resistor carefully because it determines gain accuracy and stability. Keep input and feedback routing compact, observe the specified supply limits, and verify common-mode voltage, input protection, and output-swing requirements against the actual sensor and measurement chain. The INA128P is not a power semiconductor, so safe-operating-area data is not applicable. This page combines verified manufacturer specifications, distributor availability information, cross-reference results, and practical design guidance for engineers evaluating precision sensor-signal conditioning.

RFQ تماس
INA128PA - 130dB CMRR Low-Power INA | Texas Instruments
INA128PA

INA128PA - 130dB CMRR Low-Power INA | Texas Instruments

The Texas Instruments INA128PA is a precision, low-power instrumentation amplifier with 130 dB CMRR, 700 µA quiescent current, and an 8-pin PDIP package. It uses a versatile three-op-amp architecture to amplify small differential signals while rejecting common-mode interference. Its specified low offset voltage, low drift, low bias current, wide supply range, and protected inputs make it suitable for precision measurement systems. The device supports gains from 1 through 10,000 using one external gain-setting resistor and retains useful bandwidth at high gain. An instrumentation amplifier is a specialized analog amplifier optimized for measuring low-level differential signals in the presence of large common-mode voltages. Its internal three-op-amp arrangement provides high input impedance, accurate differential gain, and strong common-mode rejection without requiring matched external resistors. INA128PA belongs to the instrumentation-amplifier hierarchy, which sits within signal-conditioning and amplifier ICs used in instrumentation, industrial control, biomedical measurement, and test equipment. Verified features include a maximum input offset voltage of 50 µV, maximum input voltage drift of 0.5 µV/°C, maximum input bias current of 5 nA, minimum CMR of 120 dB, input protection to ±40 V, and a supply range up to ±18 V. The low quiescent current is 700 µA, making the device suitable for power-conscious precision analog systems. According to the verified TI product data, the INA128 family provides 200 kHz bandwidth at a gain of 100. The three-op-amp internal design uses current-feedback input circuitry to preserve bandwidth as gain increases. This architecture is important when the measured signal is small and the source impedance is not negligible: the low 5 nA maximum bias current reduces loading of high-resistance sensors. The 130 dB CMRR specification helps reject common-mode voltage produced by motor systems, mains-coupled noise, or long sensor cables. Typical uses include precision current sensing, bridge-transducer amplification, biomedical instrumentation, portable measurement, laboratory equipment, and industrial process monitoring. The part can operate from dual or single supplies as supported by the family documentation, but the exact operating modes and output-swing limits should be checked against the manufacturer datasheet before final design release. For PCB implementation, keep the gain resistor close to the gain-setting pins and use a quiet ground return for the signal path. Input filtering, common-mode voltage limits, output settling, and supply decoupling must be evaluated for the target gain and bandwidth. Do not assume that the protected input rating removes the need for external transient protection in every system. This page combines verified manufacturer and distributor information, package-specific identification, application guidance, and cautious replacement analysis. Values not explicitly verified in the supplied data remain marked for engineering review rather than estimated.

RFQ تماس
INA128U - 130dB CMRR Precision Instrumentation Amplifier | TI
INA128U

INA128U - 130dB CMRR Precision Instrumentation Amplifier | TI

The Texas Instruments INA128U is a precision, low-power, three-op-amp instrumentation amplifier with 130 dB CMRR, a 700 µA quiescent current, and an 8-pin SOIC package. It operates from ±2.25 V to ±18 V, supports gains from 1 to 100,000 through an external gain-setting resistor, and is designed for measuring small differential signals superimposed on large common-mode voltages. An instrumentation amplifier is a differential amplifier optimized for sensors and balanced signal chains. Its internal three-op-amp architecture provides high input impedance and accurate differential gain, making it more practical than connecting a general-purpose op amp directly to a balanced source. Within the signal-processing hierarchy, an instrumentation amplifier is a specialized amplifier IC, while the INA128U also belongs to the broader precision analog and low-power signal-conditioning family. Key characteristics include a maximum input offset voltage of 50 µV, maximum offset drift of 0.5 µV/°C, maximum input bias current of 5 nA, and input protection to ±40 V. Current-feedback input circuitry maintains useful bandwidth at higher gain, including approximately 200 kHz at a gain of 100. The low 700 µA supply consumption supports battery-powered and portable measurement systems where amplifier power can materially affect operating time. The INA128U uses an external resistor to establish gain, simplifying programming when only one gain is required. Its three-op-amp topology offers accurate gain control and strong common-mode rejection, but requires adequate layout discipline around high-impedance inputs and the gain resistor. Input and output filtering must be selected carefully because excessive capacitance can affect stability or reduce usable bandwidth. Typical applications include bridge-transducer and pressure-sensor interfaces, precision current measurement, biomedical instrumentation, industrial process monitoring, and low-level differential sensing. The INA128U is particularly appropriate where a small sensor signal must be measured accurately in the presence of a much larger common-mode voltage and where low quiescent current is more important than very high bandwidth. For reliable operation, keep input and gain-resistor connections short, provide adequate input and output decoupling, and verify stability with the actual source impedance and cable capacitance. If the input can exceed the supply rails, use the specified protection method rather than assuming ordinary op-amp input clamps can safely absorb the applied voltage. The effective system accuracy also depends on resistor tolerance and temperature coefficient. This product record combines verified manufacturer specifications, distributor references, package and sourcing information, alternative-part analysis, and application guidance. It is intended to help engineers locate the datasheet, compare genuine same-package choices, estimate fit, and identify the design details that are not visible from a distributor listing alone.

RFQ تماس
INA128UA - 130dB CMRR Low-Power Instrumentation Amplifier
INA128UA

INA128UA - 130dB CMRR Low-Power Instrumentation Amplifier

The Texas Instruments INA128UA is a precision, low-power instrumentation amplifier with 130 dB CMRR, 700 uA quiescent current, and 1.3 MHz gain-bandwidth performance in an 8-pin SOIC package. Maximum input offset voltage is 50 uV, while input bias current is limited to 5 nA, making the device suitable for precision sensor-signal conditioning. An instrumentation amplifier is a specialized amplifier that amplifies the difference between two input signals while rejecting common-mode interference. Its internal three-op-amp architecture provides high input impedance, controlled differential gain, and strong common-mode rejection. In the power-management hierarchy, the INA128 belongs to the amplifier IC category, where it converts low-level differential sensor outputs into stable signals suitable for measurement, conversion, or control systems. Key characteristics include an externally adjustable gain from 1 to 10,000 V/V, input protection to ±40 V, and operation across dual supplies of ±2.25 V to ±18 V. The 130 dB CMRR suppresses common-mode noise from sensors and long cables, while the 50 uV maximum offset limits measurement error. Its 700 uA quiescent current also makes it appropriate for compact, low-power instrumentation. The INA128 uses a versatile three-op-amp architecture with current-feedback input circuitry. This structure supports usable bandwidth even at high gain, including approximately 200 kHz at a gain of 100. A precision gain-setting resistor between the RG pins establishes the differential gain, allowing the same device family to serve bridge, current-shunt, and general differential-signal applications. Typical uses include precision bridge transducers, strain-gauge sensing, medical instrumentation, industrial process-control equipment, and low-level current measurement. The ±40 V input protection rating can simplify protection around sensor inputs, although system designers must still maintain appropriate common-mode and supply operating limits. Designers should keep the gain resistor close to the RG pins, provide stable reference and supply bypassing, and check input and output common-mode ranges at the intended gain. Input bias-current errors, source-imbalance effects, resistor tolerance, and printed-circuit-board leakage should be included in the error budget for precision measurements. This page combines manufacturer specifications, package and pin information, drop-in replacement guidance, comparative parameters, and application-focused engineering guidance to support component selection, PCB implementation, and precision signal-chain design.

RFQ تماس
INA128UG4 - Low-Power Instrumentation Amplifier | TI
INA128UG4

INA128UG4 - Low-Power Instrumentation Amplifier | TI

Texas Instruments INA128UG4 is a precision, low-power instrumentation amplifier with 130 dB CMRR, 700 uA quiescent current, and a 1.3 MHz gain-bandwidth product in an 8-pin SOIC package. It is designed for low-level differential measurements where common-mode rejection, low offset voltage, and low input noise are more important than high-bandwidth signal processing. The device operates from ±2.25 V to ±18 V and supports a typical dual-supply configuration of ±15 V. An instrumentation amplifier is a specialized analog amplifier that measures the voltage difference between two inputs while rejecting large signals common to both inputs. Its internal three-amplifier topology provides high input impedance, accurate differential gain, and flexible gain selection through an external gain-setting resistor. The INA128 belongs to the broader precision-amplifier hierarchy and is commonly used with resistive sensors, strain gauges, bridge transducers, and high-impedance analog front ends. The INA128UG4 combines 130 dB CMRR with approximately 10 uV input offset voltage and 8 nV/sqrt(Hz) input noise. Its 700 uA supply current supports battery-powered and portable measurement systems where amplifier power consumption directly affects operating time. A 1.3 MHz bandwidth enables useful signal bandwidth, while a typical slew rate of 4 V/us supports accurate response to changing differential inputs. An external resistor on the gain-setting pins provides the gain relationship used for sensor conditioning. The device uses a precision internal architecture that is effective in systems where unwanted common-mode voltage can be substantially larger than the differential signal of interest. Its low noise and high CMRR reduce errors in bridge-based measurements, while the SOIC-8 package simplifies assembly in conventional surface-mount designs. Operation from ±2.25 V to ±18 V allows use with dual low-voltage rails or higher-voltage analog supplies, subject to the absolute maximum ratings in the manufacturer datasheet. Typical applications include weighing systems, industrial pressure and flow measurement, biomedical instrumentation, current-shunt monitoring, and laboratory sensor interfaces. In a bridge circuit, the amplifier can reject supply variation and large common-mode voltage while preserving the small differential output generated by the sensing element. The 700 uA quiescent current is particularly useful in portable equipment where each milliamp of supply demand can materially shorten battery life. The principal design consideration is resistor selection for the gain-setting network. Use stable, low-temperature-coefficient resistors and place them close to the relevant device pins to minimize added noise and parasitic resistance. Confirm common-mode range, output swing, supply current, and input bias behavior against the operating conditions before committing to a high-gain configuration. This page combines manufacturer specifications, package and pin information, sourcing guidance, parameter comparisons, and practical circuit-design notes. It also distinguishes confirmed pin-compatible alternatives from options that require additional electrical validation before production substitution.

RFQ تماس
INA129A - Precision Instrumentation Amplifier | Texas Instruments
INA129A

INA129A - Precision Instrumentation Amplifier | Texas Instruments

The Texas Instruments INA129A is a precision, low-power instrumentation amplifier packaged in an 8-pin SOIC. It offers excellent accuracy for general-purpose signal conditioning, with low offset voltage, low drift, low input bias current, high common-mode rejection, and input protection to ±40 V. Its versatile three-op-amp architecture supports externally set gains and current-feedback input circuitry that maintains wide bandwidth even at high gain, including 200 kHz at a gain of 100. An instrumentation amplifier is a specialized amplifier that amplifies the difference between two input signals while rejecting common-mode voltage and providing high input impedance. The INA129A belongs to the broader precision analog signal-conditioning hierarchy: instrumentation amplifier, differential amplifier, analog amplifier, and semiconductor. It is used where sensors, transducers, strain gauges, bridge circuits, and measurement front ends require accurate differential amplification with minimal disturbance to the source. The INA129 family is designed for low-power precision applications. A single external resistor sets the gain from 1 to 10,000, according to the manufacturer product information. The device provides a wide supply range of ±18 V, a minimum common-mode rejection of 120 dB, input bias current of 5 nA maximum, and input protection to ±40 V. Its current-feedback input stage is particularly useful in higher-gain designs because it preserves bandwidth better than a conventional voltage-feedback input arrangement. The INA129A can amplify low-level sensor signals in industrial measurement systems, bridge-based load cells, biomedical instrumentation, audio equipment, and data-acquisition systems. Its common-mode rejection helps suppress equal voltages appearing on both inputs, while high input impedance limits loading of the measured source. The ±40 V input protection provides additional robustness when connected to external wiring or larger transients, subject to the complete datasheet ratings and system design limits. When using INA129A, place the gain-setting resistor close to the appropriate gain pins and keep input and feedback traces short to reduce parasitic capacitance and noise pickup. Check supply decoupling, input common-mode range, output swing, and resistor tolerance before finalizing a design. Because the INA129A is a precision analog amplifier, grounding, shielding, clean references, and careful PCB layout can matter as much as nominal gain accuracy. This product page combines the verified INA129A electrical and physical details, manufacturer and distributor references, comparison parameters, and practical design guidance. The listed alternatives are limited to candidates supported by the supplied cross-reference data; package and pin compatibility should still be confirmed against the current manufacturer datasheet before substitution.

RFQ تماس
INA129P - Precision Low-Power 8-Pin Instrumentation Amp | TI
INA129P

INA129P - Precision Low-Power 8-Pin Instrumentation Amp | TI

The Texas Instruments INA129P is a precision, low-power instrumentation amplifier with one amplifier circuit, 120 dB minimum common-mode rejection, 50 uV maximum offset voltage, and a 200 kHz bandwidth at gain 100, packaged in an 8-pin PDIP. It accepts signals within the low-noise, low-offset instrumentation-amplifier class and supports wide bipolar supply operation up to ±18 V. An instrumentation amplifier is a specialized analog amplifier that measures a small differential voltage while rejecting common-mode interference. Its internal three-op-amp architecture supports high input impedance and adjustable gain, making it useful when a sensor produces a low-level signal and the surrounding wiring introduces substantial common-mode voltage. The INA129P is therefore positioned between a general-purpose operational amplifier and a more specialized precision measurement amplifier. Key features include 50 uV maximum offset voltage, 0.5 uV/°C maximum offset drift, 5 nA maximum input bias current, and input protection to ±40 V. The single external gain-setting resistor provides gain adjustment from 1 through 10,000 according to the manufacturer family information, while current-feedback input circuitry maintains useful bandwidth at higher gain. The stated 200 kHz bandwidth at gain 100 makes the device suitable for sensor and instrumentation signal paths rather than only static measurement. The INA129P uses a low-power instrumentation-amplifier architecture intended for precision measurement systems. Its common-mode rejection helps suppress voltage common to both inputs, and the low offset and drift reduce measurement error in bridge, current, and industrial sensor applications. The ±18 V supply capability provides flexibility for dual-supply analog systems, while the 8-pin PDIP format supports through-hole assembly and prototyping. Typical uses include bridge and load-cell signal conditioning, industrial process measurement, biomedical instrumentation, current sensing, and precision test equipment. The ±40 V input protection specification is useful when the amplifier is positioned near sensor wiring, although system-level protection and operating conditions still require engineering review. The principal design consideration is ensuring that the external gain resistor, supply bypassing, input protection, and common-mode range are matched to the sensor. For a new design, verify the exact INA129P pinout and electrical limits against the current Texas Instruments datasheet before layout release. This page consolidates verified distributor snippets, manufacturer family information, package details, and application guidance, while distinguishing documented specifications from information that requires design-team verification.

RFQ تماس
INA129PA - Precision Low-Power Instrumentation Amplifier | TI
INA129PA

INA129PA - Precision Low-Power Instrumentation Amplifier | TI

The Texas Instruments INA129PA is a precision, low-power instrumentation amplifier in an 8-pin plastic DIP package, with a maximum input offset voltage of 50 uV, maximum offset drift of 0.5 uV/degC, maximum input bias current of 5 nA, and minimum common-mode rejection of 120 dB. Its input stage tolerates voltages from -40 V to +40 V, while its supply range extends to plus or minus 18 V. These characteristics make it appropriate for precision signal conditioning where low offset, low drift, high common-mode rejection, and input protection are important. An instrumentation amplifier is a differential analog IC used to amplify the voltage difference between two inputs while rejecting signals common to both inputs. The INA129 belongs to the broader instrumentation-amplifier, amplifier-IC, and analog-semiconductor hierarchy. Its internal gain-setting arrangement supports precise amplification of small differential signals in sensor interfaces, industrial measurement systems, and laboratory equipment. The verified device features distinguish the INA129 from ordinary general-purpose operational amplifiers. A 50 uV maximum input offset voltage reduces the effect of input-referred mismatch, while the 0.5 uV/degC maximum drift limits offset variation with temperature. Maximum input bias current of 5 nA is especially relevant when the source impedance is high. Minimum CMRR of 120 dB suppresses common-mode interference, and the -40 V to +40 V input protection range helps the interface tolerate larger external voltages than the internal operating range. The INA129 supports a wide supply range of plus or minus 18 V. A wide operating range allows the amplifier to process signals within systems using higher-voltage rails while retaining the low-power characteristics highlighted for this device. Exact gain, bandwidth, quiescent-current, input-voltage, and output-voltage limits were not available in the supplied verified data and should be taken from the manufacturer datasheet before final design release. Typical uses include bridge-sensor interfaces, current-shunt measurement, precision data acquisition, industrial process monitoring, and low-level differential signal conditioning. For bridge or shunt circuits, the 120 dB minimum CMRR helps reject common-mode noise, while low offset voltage and drift reduce measurement error. The protected inputs may improve robustness when transients or nearby switching nodes can appear at the input terminals. Designers should verify the gain equation, external resistor value, permissible input and output swing, and supply-current limits against the current manufacturer datasheet. Input filtering, source-impedance balancing, grounding, and placement near the measured signal are also important because excessive imbalance can degrade CMRR and the low-offset performance expected from this precision device. This page combines verified manufacturer and distributor information with practical selection guidance, application analysis, pricing context, and verified drop-in alternatives. It distinguishes documented INA129PA characteristics from information that remains unavailable, helping engineers make a more reliable instrumentation-amplifier choice without inventing specifications.

RFQ تماس
INA129PG4 Precision Instrumentation Amplifier | Texas Instruments
INA129PG4

INA129PG4 Precision Instrumentation Amplifier | Texas Instruments

The Texas Instruments INA129PG4 is a precision, low-power instrumentation amplifier rated for a 700 µA supply current, 1.3 MHz gain-bandwidth product, and 8-PDIP package. It provides a 120 dB minimum common-mode rejection ratio, a 50 µV maximum offset voltage, and a 5 nA maximum input bias current for accurate differential-signal conditioning. An instrumentation amplifier is a specialized amplifier category designed to amplify the difference between two input signals while rejecting common-mode voltage. The instrumentation-amplifier hierarchy includes differential amplifiers, analog signal-conditioning ICs, amplifiers, and semiconductor devices. Its three-op-amp architecture and current-feedback input stage make it suitable for sensors and measurement systems in which small differential signals are superimposed on a larger common-mode voltage. Key characteristics include 4 V/µs slew rate, low offset drift of 0.5 µV/5°C maximum, and input protection to +40 V. The wide supply range extends to +18 V, while the input architecture retains a bandwidth of 200 kHz at a gain of 100. These characteristics support precision bridge, current-shunt, and sensor-amplification circuits without requiring a high-power amplifier. The INA129PG4 uses a versatile three-op-amp architecture. A single external resistor establishes the gain, allowing the same device to serve multiple measurement ranges. Its current-feedback input circuitry is designed to preserve usable bandwidth at higher closed-loop gains. The combination of low supply current, low offset, high CMRR, and protected inputs makes it especially useful for compact, low-power measurement instruments. Typical applications include bridge-sensor signal conditioning, portable instrumentation, industrial process monitoring, medical measurement interfaces, and low-level differential-signal acquisition. Its protected inputs can simplify front-end design when the source may produce transient overvoltage, although the complete application must still satisfy the device's absolute maximum ratings. For a new PCB, use the manufacturer pin-description table to assign all eight DIP connections and place the gain resistor close to the gain-setting pin. Check supply voltage, common-mode input range, input impedance, and output swing at the intended gain before finalizing component values. This product page combines the manufacturer specifications, package details, replacement analysis, parameter comparisons, and practical design guidance to help engineers evaluate the INA129PG4 before committing a precision measurement circuit to production.

RFQ تماس
INA129SHKJ - 8-Pin Precision Instrumentation Amplifier | TI
INA129SHKJ

INA129SHKJ - 8-Pin Precision Instrumentation Amplifier | TI

The Texas Instruments INA129SHKJ is a single-circuit, precision instrumentation amplifier in an 8-pin ceramic flat package (8-CFP). It supports an external-resistor gain range from 1 to 10,000, operates from wide dual supplies up to ±18 V, and provides input protection to ±40 V. Its nominal gain-bandwidth characteristic is 1.3 MHz, with a 4 V/µs slew rate. The device is designed for low-level differential measurements where common-mode rejection, low offset voltage, and controlled input bias current are important. An instrumentation amplifier is a specialized differential amplifier designed to amplify the difference between two input signals while rejecting common-mode voltage, supply variation, and other disturbances that appear equally at both inputs. Its typical hierarchy is instrumentation amplifier → differential amplifier → analog signal-conditioning IC → semiconductor. Unlike a general-purpose operational amplifier, an instrumentation amplifier commonly integrates input buffers, a differential gain stage, and feedback resistors in a high-precision package. The INA129SHKJ provides several characteristics suited to demanding measurement systems. Its gain is established with one external resistor, and its gain equation is compatible with the AD620, allowing familiar gain-selection calculations. The device is laser trimmed for low offset voltage, with a typical value of 25 µV, and its input bias current is listed as 50 nA typical. Typical common-mode rejection is 95 dB, while the manufacturer identifies 93 dB CMRR at gains of 100 or greater. Input protection extends to ±40 V for applications in which transient or fault voltages may appear at the measurement terminals. Electrically, the INA129 combines internal gain-setting elements with a single external resistor, making gain selection straightforward across a wide range. The 1.3 MHz gain-bandwidth figure supports operation across sensor instrumentation, bridge measurement, and industrial monitoring applications, although the usable bandwidth depends on the selected gain. The 4 V/µs slew rate provides adequate large-signal response for many low- and medium-frequency sensing systems. Low quiescent current and low input bias current also help reduce loading of high-impedance transducers. Typical uses include current shunt measurement, strain-gauge and resistance bridge excitation, precision sensor interfaces, industrial process monitoring, and high-voltage measurement systems where protected inputs are advantageous. The ceramic package and broad specified temperature range make the INA129SHKJ particularly relevant to harsh-environment instrumentation, including industrial, aerospace, and defense systems where long-term thermal stability and input robustness are essential. Designers should account for input and output common-mode limits, external resistor tolerance and temperature coefficient, input filtering, supply bypass capacitance, and PCB thermal performance. A single resistor sets the gain, but its tolerance directly affects gain accuracy. The protected inputs should still be analyzed for continuous overvoltage, because protection is not a substitute for correctly rating external circuitry. Reference-ground connections and exposed pad or ceramic-package thermal paths should follow the manufacturer's pin and layout guidance. This page combines package, electrical, pricing, sourcing, and lifecycle information with application guidance and engineering checks for the INA129SHKJ. It also highlights the distinction between exact package equivalence and merely similar instrumentation amplifiers, helping buyers evaluate replacement risk before committing to a board-level substitution.

RFQ تماس
INA129SHKQ - ±18V Precision Instrumentation Amplifier | TI
INA129SHKQ

INA129SHKQ - ±18V Precision Instrumentation Amplifier | TI

The Texas Instruments INA129SHKQ is a precision, low-power instrumentation amplifier with a gain of 10 V/V, a 1.3 MHz gain-bandwidth product, and a 4 V/µs slew rate, packaged in an 8-pin ceramic SOIC. It operates from a wide ±18 V supply and provides a military temperature range of -55°C to 210°C for precision signal-chain applications requiring elevated-temperature operation. An instrumentation amplifier is a specialized differential-input amplifier optimized for measuring small signals superimposed on large common-mode voltages. Its internal gain-setting architecture, high input impedance, and common-mode rejection distinguish it from general-purpose operational amplifiers. The INA129 belongs to the instrumentation-amplifier hierarchy within signal-chain ICs and analog measurement systems, where it converts low-level sensor outputs into a robust differential signal suitable for analog-to-digital conversion. Key characteristics include 25 µV typical offset voltage, 50 nA typical input bias current, and 95 dB typical common-mode rejection. The gain equation is compatible with the AD620, with a single external resistor setting gain from 1 to 10000. Input protection extends to ±40 V, while the wide ±18 V supply range supports industrial, military, and high-voltage measurement systems. A low 2 mA typical quiescent current also limits power consumption in portable or distributed instrumentation. Internally, the INA129 combines a precision input stage, difference amplifier, gain-setting network, and laser-trimmed offset compensation. Its common-mode rejection of 93 dB at gains of 100 or higher helps suppress supply noise and unwanted common-mode signals. The 1.3 MHz bandwidth supports moderately fast measurements while the 4 V/µs slew rate preserves large-signal response through the output stage. Typical uses include bridge-transducer amplification, current-shunt measurement, precision pressure sensing, ECG instrumentation, and high-voltage sensor interfaces. The ceramic SOIC package supports controlled thermal and environmental performance where an extended -55°C to 210°C operating range is required. Applications requiring only industrial-temperature grades should evaluate lower-cost standard-package variants before releasing a production design. PCB design should use short differential input traces, solid grounding around the gain resistor, and decoupling close to the supply pins. Input filtering must preserve the sensor bandwidth while limiting high-frequency noise. Because the INA129SHKQ is a high-temperature military-grade option, designers should verify thermal margins, solder assembly constraints, sourcing requirements, and all operating conditions against the Texas Instruments INA129-HT documentation. This product overview combines the device function, electrical limits, environmental ratings, replacement considerations, and application-level guidance into a practical engineering reference for instrumentation-amplifier design.

RFQ تماس
INA129SJD - Precision Low-Power Instrumentation Amplifier | TI
INA129SJD

INA129SJD - Precision Low-Power Instrumentation Amplifier | TI

The Texas Instruments INA129SJD is a precision, low-power instrumentation amplifier with a typical supply current of 700 µA, input protection across ±40 V, and a wide ±18 V supply range. The device is offered in an 8-pin CDIP package with a 0.300-inch, 7.62 mm lead spacing. Its instrumentation-amplifier architecture is intended for differential sensor signals where accurate gain, high common-mode rejection, and low input bias current are important. An instrumentation amplifier is a specialized amplifier category designed to amplify small differential signals while rejecting large common-mode voltages. INA129 belongs to the broader hierarchy of operational amplifiers, amplifier ICs, and analog signal-chain semiconductors. It is particularly useful when a sensor output is much smaller than the voltage referenced to ground and must be measured accurately in industrial, medical, or test equipment. Key characteristics include a typical input bias current of 50 nA, a typical common-mode rejection ratio of 95 dB, and a slew rate of 4 V/µs. The INA129-HT family uses a gain equation compatible with the AD620, making it appropriate for designs based on familiar INA129 or AD620 gain-setting networks. The input stage also supports operation where transient voltage appears at the measurement inputs, while low quiescent current helps limit power consumption in continuously energized equipment. The INA129SJD combines differential measurement capability with a low-power architecture suitable for battery-operated and space-constrained instruments. Its typical 700 µA supply current supports efficient operation when the amplifier remains active during long measurement intervals. Designers can use the external gain resistor to establish the required amplification while preserving the differential input arrangement and common-mode rejection characteristics. Typical uses include bridge-strip and RTD sensor interfaces, isolated industrial monitoring, medical instrumentation, battery-powered data acquisition, and precision laboratory measurement. The high input impedance associated with the 50 nA typical bias current reduces loading on high-impedance sources. In systems with substantial ground offsets, the 95 dB typical common-mode rejection helps preserve measurement integrity. When laying out the circuit, keep the input, feedback, and gain-resistor paths compact and electrically symmetric to minimize parasitic imbalance. Place input protection and filtering components only after checking their capacitance, leakage, and tolerance effects on input bias current and common-mode performance. Verify the power-supply arrangement against the ±18 V operating range and the ±40 V protected-input condition. This product overview combines the manufacturer specifications with package information, application guidance, and compatible same-family options for engineers evaluating instrumentation-amplifier selections. The comparison and design notes emphasize practical fit, package compatibility, and the trade-offs between precision, protection, power, and gain functionality.

RFQ تماس
INA129U - ±18V Precision Instrumentation Amp | Texas Instruments
INA129U

INA129U - ±18V Precision Instrumentation Amp | Texas Instruments

The Texas Instruments INA129U is a precision, low-power instrumentation amplifier with a 1.3 MHz gain-bandwidth product, 120 dB minimum common-mode rejection, and an 8-pin SOIC package. It accepts single or dual supplies up to ±18 V and uses one external resistor to set gain from 1 through 10,000. Designed around a versatile three-op-amp architecture, the INA129U supports accurate differential measurement while preserving wide common-mode range and robust input protection. An instrumentation amplifier is a specialized amplifier category that measures the voltage difference between two inputs while rejecting signals common to both nodes. INA129U belongs to the hierarchy instrumentation amplifier, differential amplifier, analog signal-conditioning IC, and power-management-independent semiconductor. Its three-op-amp topology provides high input impedance, precise differential gain, and improved common-mode rejection compared with a simple difference amplifier. Key verified features include maximum offset voltage of 50 µV, maximum offset drift of 0.5 µV/°C, maximum input bias current of 5 nA, and differential input protection extending to ±40 V. The current-feedback input circuitry maintains useful bandwidth at higher closed-loop gains, including 200 kHz at a gain of 100. These characteristics make the device useful where small transducer outputs must be amplified accurately in the presence of a larger common-mode voltage. The INA129 gain equation uses a 49.4 kΩ external resistor to support drop-in replacement with comparable instrumentation amplifiers. Gain accuracy depends on that resistor and associated layout parasitics, so designers should follow the manufacturer gain-setting guidance and preserve a symmetric input path. Low bias current is especially valuable for high-impedance sensor sources, while high CMR suppresses supply and ground disturbances that appear equally on both inputs. Typical uses include bridge-transducer signal conditioning, isolated low-voltage sensing, current-shunt measurement, biomedical acquisition, industrial sensor interfaces, laboratory instrumentation, and portable diagnostic equipment. For these applications, the ±40 V protected inputs can reduce accidental overload risk, although external protection and supply limits still require validation. The principal design consideration is keeping both input paths symmetric and placing the gain resistor close to the device. Incorrect Kelvin routing or unequal input impedance can degrade CMR and offset performance. The 8-pin SOIC also makes PCB assembly straightforward, while exposed thermal behavior and supply noise still require normal analog-layout practices. This page consolidates verified manufacturer and distributor information, package details, purchasing context, applications, and replacement guidance. It also distinguishes explicitly supported drop-in candidates from parts that require engineering review, helping designers compare the INA129U with alternatives rather than treating them as automatic equivalents.

RFQ تماس