AD976ACNZ - 16-Bit 200 kSPS ADC | Analog Devices
MPN: AD976ACNZ ✓ فعالAD976ACNZ نمای کلی
An ADC is an analog-to-digital converter, a semiconductor that samples a continuous analog voltage and converts it into a numeric value. Within the broader hierarchy of data-acquisition ICs, converters are classified by resolution, conversion architecture, sampling rate, and interface type. The AD976A combines a 16-bit resolution with a successive-approximation architecture, making it suitable for systems that require more precision than 12-bit converters but do not need the throughput of high-speed flash or pipeline converters.
Principal features include 16-bit resolution, one analog input, 200 kSPS throughput, a parallel interface, and single 5 V operation. The 200 kSPS rate provides 5 microseconds per conversion, making the device appropriate for industrial instrumentation, communications, test equipment, control systems, and other acquisition paths operating in the hundreds-of-kilohertz range. A parallel interface also provides a direct connection to digital logic or a suitable data-acquisition interface.
The AD976A is the 200 kSPS member of the AD976 family, while the original AD976 is specified at 100 kSPS. Successive-approximation conversion uses a capacitor array, comparator, and successive comparison stages to determine the digital result. This architecture is well suited to precision measurements where conversion latency, resolution, and power efficiency matter more than very high sampling throughput.
Typical uses include digitizing process-control signals, sampling transducers, capturing low-frequency waveforms, conditioning sensor outputs, and feeding parallel ADC data into digital signal processing or control logic. The device can support instrumentation systems in which a sensor signal is buffered, scaled to the converter's input range, sampled, and then processed as a 16-bit value.
For layout and assembly, place the input and reference circuitry close to the converter and follow the pin-description table in the Analog Devices AD976 datasheet when assigning every 28-pin DIP connection. Keep analog and digital return currents separated where practical, provide stable supply bypassing, and verify signal settling before the sampling instant. The plastic DIP package is suitable for conventional through-hole assembly and prototype or legacy equipment.
This product page combines the AD976ACNZ electrical identity, package and ordering information with practical selection guidance, a comparison table, and design-focused implementation notes. It also highlights the important distinction between the 200 kSPS AD976A and the 100 kSPS original AD976 when evaluating system timing and replacement decisions.
جایگزینهای drop-in برای AD976ACNZ — همان پکیج، سازگار پینبهپین. قطعات با پکیج متفاوت که نیاز به تغییر PCB دارند مستثنی هستند.
گونهها در این سری
مدلهای همسری که جایگزین مستقیم هستند برای AD976ACNZ (همان فرمفاکتور و فوتپرینت) — متفاوت در Mounting Type, Resolution, Sampling Rate, Architecture, Input Type.
هیچ جایگزین مستقیمی برای این محصول موجود نیست.
درخواست جایگزینAD976ACNZ حداکثر مقادیر مجاز و مشخصات الکتریکی
| رزولوشن | 16 bit |
| Conversion Architecture | Successive approximation (SAR) |
| Input Count | 1 analog input |
| نرخ نمونهبرداری | 200 kSPS |
| Conversion Time | 5 us at 200 kSPS |
| ولتاژ تغذیه | 5 V |
| Analog Supply Voltage Range | 4.75 V to 5.25 V |
| Data Interface | Parallel |
| بستهبندی | 28-pin plastic DIP |
| Package Body Width | 0.600 in (15.24 mm) |
| دمای کاری | -40°C to +85°C |
| Maximum Power Dissipation | 100 mW |
| نوع نصب | Through-hole |
| Shipping Method | Tube |
راهنمای پیکربندی پین AD976ACNZ 0.600 in (15.24 mm)
پیکربندی پین برای AD976ACNZ (پکیج 0.600 in (15.24 mm)). این قطعه آنالوگ دارای پینهای ورودی، خروجی و تغذیه است. برای پیکربندیهای پین offset null، جبرانسازی و فعالسازی به دیتاشیت سازنده مراجعه کنید. ایدهآل برای مدارهای شرطیسازی سیگنال و تقویتکننده.
داده پینآوت تفصیلی موجود نیست برای AD976ACNZ.
به دیتاشیت برای پیکربندی کامل پینها.
کاربردهای معمول
AD976ACNZ مناسب است برای 6 کاربردs: Industrial Process Signal Acquisition, Transducer Measurement Systems, Communications Signal Capture, Test and Measurement Instruments, Waveform Monitoring and Control, Medical Signal Monitoring.
Industrial Process Signal Acquisition
The AD976ACNZ fits industrial process-monitoring paths that need 16-bit numerical resolution at up to 200 kSPS. Its 5-microsecond conversion interval allows the converter to sample conditioned pressure, temperature, level, or vibration signals more rapidly than the original 100 kSPS AD976 family. The front end should buffer the sensor output, scale it to the converter's permitted analog range, and allow adequate settling before each sample. A parallel interface then transfers each 16-bit result to acquisition logic without a serial-conversion stage.
Transducer Measurement Systems
The AD976ACNZ is well suited to transducer measurement systems in which a conditioned analog voltage must be converted for digital filtering, compensation, or control. A 16-bit converter preserves substantially more numerical detail than a 12-bit device, while the 200 kSPS sampling rate supports changing sensor conditions. The conditioning stage must provide low-noise amplification and suitable drive impedance, and the converter's reference and supply arrangements must remain stable enough to preserve measurement integrity across the operating temperature range.
Communications Signal Capture
The AD976ACNZ can serve as the sampling element in low- or moderate-bandwidth communications equipment when the channel bandwidth does not require a higher-rate converter. Its 200 kSPS rate permits 200,000 samples per second, and the 16-bit output supports digital filtering, demodulation, or protocol processing after conversion. Designers should use the manufacturer's acquisition and timing information to determine whether a 5-microsecond sampling interval satisfies the required bandwidth and aliasing margin.
Test and Measurement Instruments
The AD976ACNZ is appropriate for laboratory and industrial test equipment that captures analog waveforms at rates up to 200 kSPS. Sixteen-bit resolution provides detailed sample values, and the parallel interface is useful when the converter feeds FPGA, DSP, or microprocessor-based acquisition logic. The analog input network must suppress out-of-band energy, the reference must remain stable, and PCB routing should minimize digital switching disturbance around the converter.
Waveform Monitoring and Control
For waveform monitoring and feedback-control equipment, the AD976ACNZ combines 200 kSPS throughput with a 16-bit successive-approximation architecture. This allows the controller to observe rapidly changing analog conditions, calculate a numeric representation, and apply corrections through its control loop. The design should account for the 5-microsecond conversion interval, acquisition settling requirements, and propagation delay through downstream digital processing so that sampled values remain synchronized with the physical system.
Medical Signal Monitoring
The AD976ACNZ can be used in medical monitoring modules that acquire low-bandwidth sensor signals requiring higher resolution than a basic 12-bit converter. The 200 kSPS rate is sufficient for many physiological or diagnostic sensor signals, while the parallel output supports digital processing of acquired samples. A medical design still requires suitable input isolation, protection, low-noise analog conditioning, reference design, and validation for its intended system; regulatory qualification is not implied by the converter itself.
دادههای مرجع مهندسی برای AD976ACNZ — مقایسه، راهنمای طراحی و اطلاعات انطباق.
راهنمای انتخاب
مقایسه با جایگزینها
| پارامتر | این محصول |
|---|---|
| Package | 28-pin plastic DIP |
| Brand | Analog Devices |
| Resolution | 16 bit |
| Conversion Architecture | Successive approximation (SAR) |
| Sampling Rate | 200 kSPS |
| Conversion Time | 5 us at 200 kSPS |
| Input Count | 1 analog input |
| Supply Voltage | 5 V |
| Analog Supply Voltage Range | 4.75 V to 5.25 V |
| Data Interface | Parallel |
| Operating Temperature | -40°C to +85°C |
| Maximum Power Dissipation | 100 mW |
تفاوتهای کلیدی
- Twice the sampling rate of the original AD976 family (در مقابلAD976CNZ)
- Higher resolution than common lower-resolution converters (در مقابلADS774JU)
- Through-hole package supports conventional DIP assembly (در مقابلADS774JU)
یادداشتهای طراحی
Route the parallel data bus away from the analog input and reference paths, and keep switching-node copper beneath the analog signal area to a minimum. Place bypass capacitors close to the supply and ground pins, then use the Analog Devices AD976 datasheet pin-description table to route every 28-pin connection. Because the package has no dedicated EP, each physical DIP position must be checked against the manufacturer drawing before drilling or assembling the board.
Design the analog input network so that the source settles to the required accuracy within the acquisition interval. At 200 kSPS, the sampling interval is 5 microseconds, making source impedance, capacitor selection, and switch resistance important. Check settling against the converter's acquisition specification rather than estimating from the conversion time alone, and keep the input away from digital clock and data nets.
Do not treat every AD976-family ordering code as an interchangeable substitute. The AD976A provides 200 kSPS, while the original AD976 provides 100 kSPS, and package suffix changes can alter the physical package or temperature grade. Before replacement, verify resolution, sampling rate, supply range, interface, pin names, pin numbering, and package dimensions against the manufacturer datasheet.
Decouple the single 5 V supply close to the converter and keep return-current paths compact. The documented maximum power dissipation is 100 mW, but actual dissipation depends on supply voltage, operating rate, output activity, and ambient conditions. Use the manufacturer's recommended supply and bypass arrangement to prevent supply disturbance from propagating into the analog input or reference node.
اطلاعات انطباق
Compliance status was not established in the available manufacturer, distributor, or cross-reference information.