ICL7126CQH - 3.5-Digit LCD A/D Converter | Analog Devices
MPN: ICL7126CQH ✓ فعالICL7126CQH نمای کلی
The ICL7126CQH belongs to the ADC/DAC category of signal-conversion semiconductors. An A/D converter, also called an analog-to-digital converter, transforms a continuously varying analog voltage into a numeric code suitable for measurement, display, control, or data acquisition. A 3.5-digit converter can resolve approximately 1999 principal counts and is commonly used for panel meters, laboratory instruments, industrial readouts, and portable measurement systems where more resolution than a simple three-digit display provides is useful.
The manufacturer describes the ICL7126 family as a low-power device intended to drive liquid-crystal displays directly. Its integrated seven-segment decoders reduce the external logic required between the conversion result and the LCD. Direct LCD drive simplifies instrument construction by limiting the main external circuitry to the input network, timing components, display connections, and normal bypass or protection components described in the manufacturer data sheet.
The ICL7126CQH is specified in the 44-LCC J-lead package and appears on the manufacturer's product page as a production product. Analog Devices also recommends the ICL7136 for new designs, which is an important lifecycle consideration when selecting between continued use of an established converter and migration to a newer family member. The exact electrical limits, conversion timing, input impedance, reference characteristics, display-drive specifications, and environmental ratings should be taken from the ICL7126 manufacturer data sheet before release of a production circuit.
Common uses include digital panel meters, digital multimeters, laboratory measurement instruments, temperature controllers, process-monitoring displays, weighing systems, and portable data-acquisition equipment. The integrated display path is particularly useful where designers want a numeric readout without adding a separate display decoder or driver IC.
When designing around the ICL7126CQH, begin with the manufacturer pin-description table and application information rather than assigning signals by function alone. Confirm the LCD glass segment mapping, input-source range, reference arrangement, timing components, and bypass requirements directly against the data sheet. Also evaluate the suggested ICL7136 before committing to a long-lived design if the project is newly started.
This page organizes the verified package, display, resolution, interface, lifecycle, and sourcing details into an engineering-focused format. It also separates confirmed attributes from parameters that require direct comparison against the manufacturer data sheet, helping designers assess fit before committing the 44-LCC footprint to a PCB layout.
جایگزینهای drop-in برای ICL7126CQH — همان پکیج، سازگار پینبهپین. قطعات با پکیج متفاوت که نیاز به تغییر PCB دارند مستثنی هستند.
ICL7126CQH-D
✅ جایگزین مستقیم📋 جایگزین مرجع (خارج از کاتالوگ)
ICL7126CQH+D
✅ جایگزین مستقیم📋 جایگزین مرجع (خارج از کاتالوگ)
ICL7126CQH حداکثر مقادیر مجاز و مشخصات الکتریکی
| Product Type | 3.5-digit A/D converter with LCD display driver |
| رزولوشن | 3.5 digits |
| Display Digits or Characters | A/D 3.5 digits |
| Display Configuration | 7-segment |
| Display Type | LCD |
| نوع رابط | Direct LCD display interface |
| بستهبندی | 44-LCC (J-Lead) |
| Package Code | QCCJ |
| Package Shape | Square |
| Terminal Form | J Bend |
| Number of Terminals | 44 |
| Temperature Grade | Commercial |
| Conversion Method | Dual-slope A/D conversion |
| Integrated Functions | Seven-segment decoders, display drivers, reference, and clock |
| Process Technology | CMOS |
راهنمای پیکربندی پین ICL7126CQH square
پیکربندی پین برای ICL7126CQH (پکیج square). این قطعه آنالوگ دارای پینهای ورودی، خروجی و تغذیه است. برای پیکربندیهای پین offset null، جبرانسازی و فعالسازی به دیتاشیت سازنده مراجعه کنید. ایدهآل برای مدارهای شرطیسازی سیگنال و تقویتکننده.
داده پینآوت تفصیلی موجود نیست برای ICL7126CQH.
به دیتاشیت برای پیکربندی کامل پینها.
کاربردهای معمول
ICL7126CQH مناسب است برای 6 کاربردs: Digital Panel Meters, Laboratory Measurement Instruments, Industrial Process Readouts, Temperature Measurement Displays, Portable Data Acquisition, Weighing and Calibration Systems.
Digital Panel Meters
The ICL7126CQH fits digital panel meters that require a stable numeric LCD readout without a separate display-decoder IC. Its confirmed 3.5-digit resolution and seven-segment display architecture suit instrument scales that benefit from finer display resolution than a three-digit display. The dual-slope converter and integrated reference, clock, decoder, and display-driver blocks simplify the signal chain. Engineers should use the manufacturer data sheet to set the input range, timing, reference configuration, and segment mapping for the chosen LCD glass.
پیشنهادی
Laboratory Measurement Instruments
ICL7126CQH is appropriate for laboratory instruments where a three-and-a-half-digit LCD is the intended readout format. The integrated seven-segment decoder and LCD drivers remove several discrete display-interface functions, while the 3.5-digit result supports clear numerical readings in bench meters and process monitors. The device must be paired with suitable input conditioning and a matched display glass. Before layout release, verify timing, reference, bypass, and segment assignments against the manufacturer data sheet.
پیشنهادی
Industrial Process Readouts
The ICL7126CQH can be used in industrial process-monitoring equipment that presents a sensor-derived measurement on an LCD. A 3.5-digit format provides approximately 1999 principal counts, while direct seven-segment drive reduces the need for external display logic. Commercial temperature grade makes the part appropriate for many indoor industrial environments, subject to the exact environmental limits in the data sheet. Protection, isolation, calibration, and input filtering must be designed around the measured signal and operating environment.
پیشنهادی
Temperature Measurement Displays
ICL7126CQH is suitable for a compact temperature display when the sensor signal is conditioned to the converter's supported input range. Its integrated LCD path supports a clear 3.5-digit readout for thermometers, controllers, and environmental monitors. The external circuit should include the required sensor conditioning, input filtering, and reference components defined by the manufacturer application guidance. Verify the glass segment layout and startup behavior during prototype bring-up to prevent errors that resemble incorrect temperature readings.
پیشنهادی
Portable Data Acquisition
ICL7126CQH supports portable measurement products where a compact LCD provides immediate local feedback from a low-power acquisition system. The integrated conversion and display functions reduce board-area requirements, and the 3.5-digit readout offers useful resolution for portable scales, calibrators, and field-service instruments. Battery-operated designs still require careful attention to the converter's actual supply current and power-dissipation limits. Confirm those figures and the permitted input configuration directly from the manufacturer data sheet.
پیشنهادی
Weighing and Calibration Systems
ICL7126CQH can form the display section of a compact weighing or calibration instrument when the load-cell or sensor output is properly scaled. The 3.5-digit seven-segment readout provides a clear numerical result for bench scales and portable calibrators, while integrated decoding reduces display-interface complexity. A production design should validate zeroing, span, excitation stability, input filtering, and display calibration. The manufacturer timing and reference recommendations should be followed because they directly affect repeatability and initial reading recovery.
پیشنهادی
خلاصه محصولات پیشنهادی
دادههای مرجع مهندسی برای ICL7126CQH — مقایسه، راهنمای طراحی و اطلاعات انطباق.
راهنمای انتخاب
مقایسه با جایگزینها
| پارامتر | این محصول | ICL7126CQH-D | ICL7126CQH+D |
|---|---|---|---|
| Manufacturer | Analog Devices | Analog Devices | Analog Devices |
| Package | 44-LCC (J-Lead) | 44-LCC (J-Lead) | 44-LCC (J-Lead) |
| Package Code | QCCJ | QCCJ | QCCJ |
| Terminal Count | 44 | 44 | 44 |
| Terminal Form | J Bend | J Bend | J Bend |
| Conversion Method | Dual-slope | Dual-slope | Dual-slope |
| Resolution | 3.5 digits | 3.5 digits | 3.5 digits |
| Display Output | Direct 7-segment LCD | Direct 7-segment LCD | Direct 7-segment LCD |
| Lifecycle Recommendation | ICL7126 production; ICL7136 suggested for new designs | ICL7126 family ordering code | ICL7126 family ordering code |
تفاوتهای کلیدی
- Integrated display interface reduces external circuitry (در مقابلAD779JN)
- Purpose-built 3.5-digit numerical readout (در مقابلADS1254E)
- Established production family with manufacturer-supported migration path (در مقابلICL7136)
یادداشتهای طراحی
Use the manufacturer's pin-description table and LCD glass segment map before assigning tracks on the 44-LCC J-lead board. Keep the analog input and reference paths away from display segment outputs, especially when the converter is used with long LCD interconnects. The 44-LCC footprint has more pins than many low-cost microcontroller packages, so verify pad geometry and assembly clearances against the QCCJ drawing before committing the board outline.
Follow the manufacturer input-voltage, reference, and bypass requirements exactly. The confirmed package and converter architecture do not by themselves establish allowable supply combinations, so do not infer a safe rail from another ICL family member. Place required bypass capacitors close to their specified pins, maintain the recommended grounding topology, and keep switching-regulator and display-return currents out of the analog input and reference paths.
Do not treat mechanically similar LCDs as electrically interchangeable. Segment outputs, common-drive arrangements, and pin assignments can differ between display glasses. Validate the ICL7126CQH-to-LCD connection against the display datasheet and the converter pin table, then check every digit and annunciator segment during production test. Also verify the exact ICL7126 ordering suffix before treating ICL7126CQH-D or ICL7126CQH+D as a procurement substitute.
Plan the analog input and reference network close to the converter while allowing the display signals to reach the LCD connector without crossing sensitive measurement nodes. Confirm whether the chosen LCD interface uses common or segment-drive arrangements described in the data sheet. Maintain accessible test points for input, reference, and display timing so calibration and troubleshooting can be performed without redesigning the board.
اطلاعات انطباق
The verified records identify a commercial-grade integrated circuit but do not provide exact-ordering-code RoHS, REACH, lead-free, halogen-free, or conflict-minerals declarations. AEC-Q100 is not applicable because this is a commercial measurement IC rather than an automotive-qualified claim shown in the records.