Renesas Electronics Corporation ICS270PG is a field-programmable voltage-controlled crystal oscillator and triple-PLL clock synthesizer that generates up to eight high-quality, high-frequency clock outputs. It supports a maximum frequency of 200 MHz, uses a crystal input, provides CMOS outputs, includes PLL bypass, and is packaged in a 20-pin TSSOP measuring 0.173 inch, or 4.40 mm, wide.

A clock synthesizer is an integrated timing device that accepts a reference source and derives one or more stable, programmable clock outputs for digital systems. A VCXO adds voltage-controlled frequency adjustment to the crystal reference, while a PLL multiplies or divides that reference to produce the required output frequencies. The ICS270PG combines both functions in a clock and timing IC, allowing one reference crystal to serve multiple clock domains.

Its principal features include three phase-locked loops, PLL bypass capability, one internal clock circuit, a crystal reference input, and CMOS output signaling. The synthesizer can generate as many as eight outputs, including multiple reference clocks originating from a low-frequency reference source. This output flexibility reduces the number of separate oscillators required in systems requiring related but unequal clock rates.

The triple-PLL architecture separates clock-generation functions that might otherwise require multiple oscillator and divider combinations. PLL bypass is useful during configuration, test, or operating conditions where a directly derived clock path is preferred. CMOS outputs are suitable for interfacing with modern digital logic, while the 200 MHz maximum output frequency supports demanding processor, communications, data-conversion, and industrial control clock trees.

Typical applications include communications infrastructure, instrumentation, industrial automation, test and measurement equipment, data-acquisition systems, and embedded control platforms. In each case, the device can centralize multiple clock requirements around a crystal reference and provide programmable outputs instead of requiring a separate oscillator for each frequency domain. The multiple reference outputs can support communication links, data converters, memory interfaces, and digital control logic within one clock tree.

The principal design consideration is the device's programmed configuration and the resulting relationships among its three PLLs, reference outputs, and output dividers. Review the manufacturer datasheet's pin-description table, recommended external components, clock-output constraints, and programming procedure before laying out a new board. PCB placement should minimize clock traces and keep the crystal and associated components close to the device.

This product page summarizes the documented architecture, package information, output capability, and practical design considerations of the ICS270PG. It also distinguishes verified technical facts from details that still require confirmation from the manufacturer datasheet, helping engineers plan the architecture without overlooking programming, layout, or qualification work.

جایگزین‌های drop-in برای ICS270PG — همان پکیج، سازگار پین‌به‌پین. قطعات با پکیج متفاوت که نیاز به تغییر PCB دارند مستثنی هستند.

ICS270CG

✅ جایگزین مستقیم ⚠️ مشخصات تأییدنشده
📦 20-TSSOP
Same ICS270 family, 20-TSSOP footprint, triple-PLL VCXO architecture, and 200 MHz maximum frequency; temperature-grade details require confirmation from the manufacturer datasheet

📋 جایگزین مرجع (خارج از کاتالوگ)

ICS270PG مشخصات

Device Type Clock/Frequency Synthesizer, Fanout Buffer (Distribution)
Architecture Triple-PLL field-programmable VCXO clock synthesizer
Maximum Frequency 200 MHz
Number of Clock Circuits 1
PLL Count 3 PLLs
PLL Bypass Yes
Reference Input Crystal
نوع خروجی CMOS
Maximum Output Count 8 outputs
Reference Output Capability Multiple reference clocks from a low-frequency reference
Programmability Field programmable
Frequency Control Method Voltage-controlled crystal oscillator (VCXO)
بسته‌بندی 20-TSSOP
Package Width 0.173 inch (4.40 mm)
نوع نصب Surface Mount
وضعیت RoHS unknown
REACH Status unknown
AEC-Q100 Qualification not_applicable

راهنمای پیکربندی پین ICS270PG 0.173 inch (4.40 mm)

پیکربندی پین برای ICS270PG (پکیج 0.173 inch (4.40 mm)). شماره‌گذاری پایه‌ها، عملکردها و نمودارهای اتصال در دیتاشیت سازنده تعریف شده است. برای footprint دقیق و دستورالعمل‌های لحیم‌کاری به آن مراجعه کنید.

نمودار پین‌آوت پکیج 0.173 inch (4.40 mm) برای ICS270PG

داده پین‌آوت تفصیلی موجود نیست برای ICS270PG.

به دیتاشیت برای پیکربندی کامل پین‌ها.

کاربردهای معمول

ICS270PG مناسب است برای 6 کاربردs: Communications Clock Trees, Industrial Automation Systems, Test and Measurement Equipment, Data Acquisition Systems, Embedded Control Platforms, Network and Interface Timing.

🌐

Communications Clock Trees

The ICS270PG fits communications equipment that requires several related clock signals from one crystal reference. Its three-PLL architecture can derive up to eight outputs, including multiple reference clocks from a low-frequency source, while the documented maximum frequency reaches 200 MHz. This allows interface logic, converters, and control circuits to be organized around a common timing origin instead of using unrelated oscillators. The principal benefit is centralized clock management and fewer independent frequency-generation blocks. Engineers should still compare the required output frequencies, divider ratios, jitter, and channel relationships with the manufacturer programming and timing limits before finalizing the clock architecture.

🏭

Industrial Automation Systems

Industrial automation controllers can use the ICS270PG to distribute multiple programmable clocks required by sampling, communication, memory, and control subsystems. The device's triple-PLL VCXO topology accepts a crystal reference and can generate up to eight outputs, including multiple reference clocks. Using one synthesis device simplifies frequency relationships and may reduce the number of discrete oscillator paths. Its 200 MHz ceiling supports higher-speed digital subsystems while CMOS outputs connect to modern logic. Because the available product information does not state the industrial temperature range, qualification limits, or long-term availability commitments, confirm those requirements against the manufacturer documentation before production deployment.

🖥️

Test and Measurement Equipment

The ICS270PG is applicable to instrumentation that needs coherent clocks across acquisition, conversion, processing, and communication sections. A common crystal-derived reference and up to eight outputs allow clock domains to remain mathematically related, which can simplify calibration and synchronization reasoning. The triple-PLL architecture also permits programmable frequency relationships where supported by the configuration method. PLL bypass can support controlled test or reference-clock operating modes. For laboratory-grade instruments, verify output jitter, phase-noise behavior, temperature stability, and supply requirements in the manufacturer datasheet, since those characteristics are not quantified in the available product listing.

📊

Data Acquisition Systems

Data-acquisition designs often combine converters, digital signal processors, memory, and communications interfaces with related but unequal clock rates. The ICS270PG can serve this need through its crystal input, three PLLs, and as many as eight CMOS outputs derived from a low-frequency reference. Centralizing these signals can make clock routing and phase relationships easier to manage than a collection of independent oscillators. Its 200 MHz maximum frequency accommodates demanding digital processing paths. Designers should assign each output through the manufacturer's programming procedure and confirm that all divider ratios, output frequencies, and acquisition timing requirements remain valid across the complete operating range.

🧩

Embedded Control Platforms

An embedded control platform can benefit when it must support several related clock domains for processors, memory, serial links, and peripherals. The ICS270PG's triple-PLL VCXO architecture derives multiple outputs from one crystal reference, while PLL bypass provides an additional clock-path option for testing or operating modes. This approach can reduce oscillator component count and create a clear timing hierarchy. The 20-TSSOP package supports compact surface-mount assembly. Because controller interfaces, supply voltages, and timing tolerances vary considerably, check the complete electrical and programming requirements in the manufacturer datasheet before assigning ICS270PG outputs to a specific processor or peripheral.

🌐

Network and Interface Timing

Network interface equipment often needs multiple reference and working clocks distributed among high-speed logic, transceivers, and support circuits. The ICS270PG can generate up to eight CMOS clock outputs, including multiple reference clocks, from a crystal-based source using three PLLs. This makes it suitable for centralized timing in interface-centric designs, particularly where clock domains must remain coordinated. The 200 MHz maximum output frequency supports demanding digital logic, while bypass offers flexibility during diagnostic or configuration work. Validate lane-rate assumptions, clock-to-output uncertainty, jitter, and supply sequencing against the manufacturer limits, because the available listing does not quantify these timing specifications.

What is the ICS270PG?
The ICS270PG is a Renesas Electronics Corporation triple-PLL, field-programmable VCXO clock synthesizer capable of generating up to eight clock outputs. According to the ICS270 manufacturer datasheet, it accepts a crystal reference, provides CMOS clock outputs, supports PLL bypass, and operates up to 200 MHz. It is intended for systems that need multiple related clocks derived from one low-frequency reference rather than several independent oscillators.
What are the key specifications of ICS270PG that engineers should know?
The ICS270PG combines three PLLs, crystal-reference operation, PLL bypass, and as many as eight CMOS outputs in a 20-TSSOP package. Its documented maximum operating frequency is 200 MHz, and the package is listed as 0.173 inch, or 4.40 mm, wide. According to the ICS270 manufacturer datasheet, the device also provides multiple reference clocks from a low-frequency source, making it suitable for centralized clock-tree design.
What is the maximum output frequency of ICS270PG?
The maximum output frequency of the ICS270PG is 200 MHz. According to the ICS270 manufacturer datasheet, the device is a clock and frequency synthesizer with one clock circuit, a crystal input, CMOS output signaling, three PLLs, and PLL bypass capability. Confirm the applicable output-divider, PLL, and operating-condition limits for the specific configuration when planning a high-frequency clock tree.
How many clock outputs can ICS270PG generate?
The ICS270PG can generate up to eight high-quality, high-frequency clock outputs, including multiple reference clocks derived from a low-frequency source. According to the ICS270 manufacturer datasheet, this output count allows one programmable synthesizer to serve several clock domains. The exact output arrangement depends on the selected PLL and divider configuration.
Where can I download the ICS270PG datasheet PDF?
The ICS270PG datasheet PDF can be accessed through the linked datasheet page on alldatasheet.com, which identifies the part as a triple-PLL field-programmable VCXO clock synthesizer. The device documentation covers its architecture, electrical limits, pin configuration, clock outputs, and application information. Use the manufacturer datasheet as the controlling reference for design release and production testing.
Where can I find the ICS270PG pinout?
The ICS270PG pinout is located in the pin-description table of the manufacturer datasheet. This 20-pin TSSOP device includes control, programming, reference, PLL, and clock-output connections whose exact assignments must be followed during PCB layout. Consult the pin-description table and package drawing together so signal names, direction, and exposed package geometry remain consistent.
Can ICS270PG replace a discrete multi-oscillator clock design?
The ICS270PG can consolidate many oscillator functions because it offers three PLLs and up to eight outputs from a crystal-referenced architecture. According to the ICS270 manufacturer datasheet, multiple reference clocks can be generated from a low-frequency source. Consolidation is practical only when the required frequencies, output formats, jitter requirements, startup behavior, and reliability targets fit the synthesizer's specified operating conditions.
What can replace the ICS270PG?
No verified pin-compatible drop-in replacement for the ICS270PG was identified in the available cross-reference results. A valid replacement must use the same 20-TSSOP footprint, preserve pin-to-pin connectivity, and match the 200 MHz maximum frequency, triple-PLL architecture, crystal input, CMOS output type, bypass behavior, and programming interface. Review the manufacturer datasheet and validate any candidate in the target system before substitution.
Is ICS270PG suitable for communications equipment?
The ICS270PG is suitable for communications clock-tree applications that require multiple outputs from a common reference. Its documented three-PLL architecture, maximum 200 MHz operation, CMOS outputs, and ability to generate multiple reference clocks support centralized timing for communications systems. Confirm output jitter, phase-noise, voltage, and environmental requirements in the manufacturer datasheet for the intended channel and operating grade.
Is ICS270PG suitable for industrial control and test systems?
The ICS270PG can support industrial control, instrumentation, and test systems that need several related clock outputs rather than separate oscillators. According to the ICS270 manufacturer datasheet, the device provides up to eight outputs, a crystal reference, three PLLs, and PLL bypass. The industrial operating-temperature range must be confirmed separately because it is not stated in the available product listing.
When should I choose ICS270PG instead of a single-output oscillator?
Choose the ICS270PG when one reference must produce several programmable or related clock domains. It is less appropriate for a simple design requiring only one fixed-frequency oscillator with minimal configuration overhead. The decision should consider output count, required frequency relationships, programming effort, channel count, timing performance, PCB area, and whether PLL bypass or multi-reference capability provides measurable system value.
What is the difference between a VCXO and a fixed crystal oscillator?
A VCXO permits controlled adjustment of a crystal oscillator's frequency, while a fixed crystal oscillator is configured for one nominal frequency. The ICS270PG combines VCXO behavior with three PLLs, allowing a low-frequency reference to support multiple generated outputs. The additional control and synthesis capability is useful when frequencies must be related, adjustable, or distributed across several logic domains.
Does ICS270PG include PLL bypass?
Yes, the ICS270PG includes PLL bypass. According to the ICS270 manufacturer datasheet, bypass is part of the clock synthesizer's architecture alongside three PLLs and a crystal input. The available excerpt does not define the complete bypass routing or mode-transition timing, so use the manufacturer timing diagrams and pin table to determine the permitted operating sequence.
What design constraints matter for an ICS270PG PCB layout?
The principal ICS270PG layout constraint is to preserve clock signal integrity while following the manufacturer's routing and component-placement guidance. Keep the crystal, its required load network, the device, and decoupling connections compact and away from high-current switching paths. Provide a low-impedance ground and ground plane, avoid unnecessary stubs, use controlled-impedance routing where appropriate, and verify output timing at the load.
Where can I request a quote for ICS270PG?
Use the Request a Quote form on this page to request current ICS270PG commercial terms, quantity availability, and lead time. The visible product record identifies the 20-TSSOP package, while the currently available listings do not print qualifying quantity-break prices for the exact MPN. The quote team can confirm current supply, lot-related conditions, and shipment configuration for the requested quantity.

داده‌های مرجع مهندسی برای ICS270PG — مقایسه، راهنمای طراحی و اطلاعات انطباق.

راهنمای انتخاب

Choose the ICS270PG when a system needs up to eight related clock outputs, a crystal reference, and programmable frequency relationships from a compact 20-TSSOP timing device. Its three-PLL VCXO architecture is particularly useful when several converters, processors, memory components, or communication links need coordinated clocks rather than unrelated fixed-frequency oscillators. Choose ICS270CG only after confirming that its ordering code, temperature grade, lifecycle status, and electrical limits satisfy the design. Do not select either part solely from the 200 MHz headline figure: verify output jitter, phase noise, reference sensitivity, supply range, programming method, and package-level pin behavior in the manufacturer datasheet. A simple fixed-frequency clock tree may be more efficient when only one output is required. For a proposed substitution, preserve the 20-TSSOP footprint, pin-to-pin functions, crystal interface, PLL behavior, CMOS output loading, and programming sequence.

مقایسه با جایگزین‌ها

پارامتر این محصول ICS270CG
Brand Renesas Electronics Renesas Electronics
Package 20-TSSOP 20-TSSOP
Device Type Clock/Frequency Synthesizer, Fanout Buffer (Distribution) Clock/Frequency Synthesizer
Architecture Triple-PLL field-programmable VCXO clock synthesizer Triple-PLL field-programmable VCXO clock synthesizer
Maximum Frequency 200 MHz 200 MHz
Reference Input Crystal Crystal
Output Type CMOS CMOS
Maximum Output Count 8 outputs 8 outputs
PLL Bypass Yes Yes
Number of Clock Circuits 1 1

تفاوت‌های کلیدی

  • Multiple outputs from one crystal-referenced synthesizer (در مقابلICS270CG)
  • Maximum operating frequency (در مقابلICS270CG)
  • Clock-generation flexibility (در مقابلICS270CG)

یادداشت‌های طراحی

Place the ICS270PG close to the crystal and its required load network, then route the reference path away from switching nodes and other high-energy clock nets. Follow the manufacturer reference layout for component spacing and grounding. Use a continuous ground plane where practical, keep clock traces short, minimize vias and stubs, and avoid routing sensitive clock lines beneath digital or power-conversion areas that can inject crosstalk.

Treat every ICS270PG output as a potentially high-frequency clock signal. Confirm the target trace impedance, load capacitance, and termination strategy from the manufacturer interface specifications. Keep fanout branches short and balanced when clocks feed multiple destinations, and validate rise time, overshoot, ringing, and timing margin at the receiver rather than relying only on source-edge measurements.

Do not assume that three PLLs automatically provide three unrelated frequencies. Program each output only within the divider, PLL, and frequency constraints stated in the manufacturer datasheet, and account for reference accuracy when setting end frequencies. Confirm the behavior of PLL bypass during startup and mode changes so that downstream logic is not exposed to an unintended clock transition.

Follow the manufacturer guidance for supply voltage, decoupling, and output enable sequencing. Place required bypass capacitors at the device power pins and provide a return path that does not force clock or reference currents through long PCB traces. Verify startup, shutdown, and configuration behavior across all operating modes, especially when PLL bypass and multiple clock outputs interact with downstream reset logic.

اطلاعات انطباق

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
بدون سرب
Unknown
بدون هالوژن
Unknown
مواد معدنی درگیری
Unknown

The available product and distributor records do not state RoHS, REACH, lead-free, halogen-free, or conflict-minerals status. The ICS270PG is a general-purpose clock and timing IC rather than an automotive-qualified device.

تاریخ تأیید داده‌ها: 2026-11-05 — داده‌ها توسط تیم مهندسی قطعات XAIPART تأیید و گردآوری شده است

جستجوهای مرتبط

ICS270PG datasheet ICS270PG specifications ICS270PG pinout ICS270PG datasheet pdf ICS270PG triple PLL ICS270PG 200MHz clock ICS270PG VCXO ICS270PG equivalent ICS270PG replacement ICS270PG price ICS270PG stock Renesas ICS270PG ICS270PG 20-TSSOP package ICS270PG communications clock

قطعات و اصطلاحات مرتبط

Renesas Electronics Integrated Device Technology ICS270PG ICS270CG clock synthesizer clock and timing IC VCXO voltage-controlled crystal oscillator triple-PLL phase-locked loop PLL bypass crystal reference CMOS output field-programmable clock clock distribution frequency synthesizer 200 MHz 20-TSSOP TSSOP package family surface-mount package fanout buffer communications timing industrial automation test and measurement data acquisition
استعلام قیمت سریع RFQ
جزئیات کامل را پر کنید — تیم فروش ما ظرف 24 ساعت پاسخ خواهد داد
شماره قطعه سازنده بسته‌بندی QTY قیمت هدف قیمت کل
✓
استعلام قیمت ارسال شد!

ظرف ۲۴ ساعت به ایمیل شما پاسخ خواهیم داد

1
درخواست قیمت ارسال شد
2
استعلام دریافت شد
3
سفارش ثبت شد
4
پرداخت
5
ارسال شد
6
تحویل داده شد
مشاهده جزئیات RFQ