Texas Instruments

OPA104BM - Low-Noise JFET Op Amp | Texas Instruments

MPN: OPA104BM ✓ فعال
±5 V to ±20 V Vdss 0.15 pA Id TO-99-8 metal can Package
حداقل سفارش: 1 |

OPA104BM نمای کلی

The Texas Instruments OPA104BM is a single-circuit JFET operational amplifier with extremely low input bias current, packaged in an 8-pin TO-99 metal-can package. The device operates from ±5 V to ±20 V, making it appropriate for precision instrumentation, low-level signal conditioning, transducers, and high-impedance sensor interfaces. Its 0.15 pA input bias current is the headline specification that makes the OPA104BM suitable for circuits where amplifier input current would otherwise disturb the measured signal.

A JFET operational amplifier is a voltage-input amplifier whose input stage uses junction field-effect transistors. It belongs to the operational amplifier hierarchy, which sits within analog ICs, analog signal-chain ICs, and semiconductor devices. Unlike bipolar-input amplifiers, JFET-input amplifiers can offer exceptionally low input bias current while retaining useful voltage-noise performance. This makes the OPA104BM appropriate for electrostatic sensors, photodetectors, chemical sensors, and laboratory instruments in which source impedance may be very high.

The OPA104BM combines a JFET input stage, one amplifier circuit, and a wide ±5 V to ±20 V operating range. The specified 0.15 pA input bias current helps minimize errors when working with picoamp-level leakage or very high source impedances. Its TO-99-8 mechanical format provides an eight-terminal metal-can package with a 4.7 mm lead pitch. Because it is a single amplifier rather than a quad device, systems requiring several precision channels must use multiple packages or choose a different multi-channel amplifier family.

The metal-can construction and through-hole lead format distinguish the OPA104BM from modern surface-mount operational amplifiers. Its long connection leads and metal shell are useful where a conventional through-hole footprint is preferred, for example in laboratory equipment, selected industrial instrumentation, and legacy control systems. Designers should treat the package pin arrangement as critical: the TO-99 lead numbering and function sequence must be checked against the manufacturer pin-description table before assigning input, output, supply, offset-null, and compensation connections.

Typical uses include precision current-to-voltage conversion, guarded sensor amplifiers, low-leakage capacitance measurements, photodiode signal conditioning, and analog instrumentation powered from split supplies. A ±5 V operating range supports low-voltage systems, while operation up to ±20 V accommodates higher-voltage laboratory rails. The amplifier is particularly useful when source current must remain small compared with the signal being measured, provided the circuit also maintains suitable common-mode voltage, output swing, noise, and stability for the selected feedback network.

A key design consideration is that low bias current alone does not determine overall measurement accuracy. Input capacitance, source impedance, resistor thermal noise, offset voltage, input common-mode range, output swing, and printed-circuit-board contamination can dominate the error budget. Guarding, clean PCB layouts, suitable resistor values, and stable reference supplies are therefore essential. This page combines package information, source-family drop-in options, parameter comparisons, and application guidance to support design decisions beyond a basic distributor listing.

جایگزین‌های drop-in برای OPA104BM — همان پکیج، سازگار پین‌به‌پین. قطعات با پکیج متفاوت که نیاز به تغییر PCB دارند مستثنی هستند.

OPA104CM

✅ جایگزین مستقیم ⚠️ مشخصات تأییدنشده
📦 TO-99-8 metal can
Same 8-terminal TO-99 footprint and 0 pin-count difference; ordering code differs in package or grade construction, so confirm temperature limits and qualification.

📋 جایگزین مرجع (خارج از کاتالوگ)

OPA104DM

✅ جایگزین مستقیم ⚠️ مشخصات تأییدنشده
📦 TO-99-8 metal can
Same 8-terminal TO-99 footprint and 0 pin-count difference; ordering code differs in grade or construction, with temperature and lifecycle details requiring confirmation.

📋 جایگزین مرجع (خارج از کاتالوگ)

OPA104TM

✅ جایگزین مستقیم ⚠️ مشخصات تأییدنشده
📦 TO-99-8 metal can
Same 8-terminal TO-99 footprint and 0 pin-count difference; ordering code differs in temperature-grade or package construction without changing the pin count.

📋 جایگزین مرجع (خارج از کاتالوگ)

OPA104UM

✅ جایگزین مستقیم ⚠️ مشخصات تأییدنشده
📦 TO-99-8 metal can
Same 8-terminal TO-99 footprint and 0 pin-count difference; ordering code differs in temperature-grade or package construction, requiring an ordering-table review.

📋 جایگزین مرجع (خارج از کاتالوگ)

OPA104BM

✅ جایگزین مستقیم ⚠️ مشخصات تأییدنشده
Texas Instruments
📦 TO-99-8 metal can
JFET operational amplifier · 1 circuit · 0.15 pA · ±5 V to ±20 V · TO-99-8 metal can · 8 terminals · 4.7 mm

برای قیمت تماس بگیرید

مشاهده دیتاشیت ←

OPA104BM حداکثر مقادیر مجاز و مشخصات الکتریکی

Amplifier Type JFET operational amplifier
Number of Circuits 1 circuit
Input Bias Current 0.15 pA
Supply Voltage Range ±5 V to ±20 V
بسته‌بندی TO-99-8 metal can
Number of Terminals 8 terminals
Lead Pitch 4.7 mm
نوع نصب Through-hole
Package Shape Round
Terminal Form Wire
وضعیت RoHS unknown
REACH Status unknown
AEC-Q100 Qualification not_applicable

راهنمای پیکربندی پین OPA104BM round

پیکربندی پین برای OPA104BM (پکیج round). این قطعه آنالوگ دارای پین‌های ورودی، خروجی و تغذیه است. برای پیکربندی‌های پین offset null، جبران‌سازی و فعال‌سازی به دیتاشیت سازنده مراجعه کنید. ایده‌آل برای مدارهای شرطی‌سازی سیگنال و تقویت‌کننده.

نمودار پین‌آوت پکیج round برای OPA104BM

داده پین‌آوت تفصیلی موجود نیست برای OPA104BM.

به دیتاشیت برای پیکربندی کامل پین‌ها.

کاربردهای معمول

OPA104BM مناسب است برای 6 کاربردs: Photodiode Signal Conditioning, High-Impedance Sensor Interface, Precision Current-to-Voltage Conversion, Laboratory Instrumentation, Low-Level Analog Signal Conditioning, Audio and Measurement Buffers.

📷

Photodiode Signal Conditioning

OPA104BM fits photodiode and phototransistor preamplifiers because its 0.15 pA input bias current limits the current drawn from a high-impedance detector. The device can be configured as a transimpedance amplifier with feedback resistance and compensation capacitance selected for the detector capacitance, bandwidth, and settling requirements. Its ±5 V to ±20 V supply range supports split analog rails commonly used around optical receivers. The principal benefit is reduced error from input leakage, although total accuracy still depends on resistor thermal noise, photodiode capacitance, input protection leakage, and guard-ring construction.

🧩

High-Impedance Sensor Interface

OPA104BM is appropriate for electrochemical, capacitive, piezoelectric, and other sensors whose source impedance is high enough that amplifier bias current could disturb the measurement. Its 0.15 pA input bias current allows very small sensor currents to develop measurable voltages across a practical feedback network. The circuit should still include input clamping, defined guarding, and a bias-return path so the amplifier inputs do not float. Engineers must also verify common-mode range, output swing, and stability because ultra-low input current does not remove those separate design constraints.

⚡

Precision Current-to-Voltage Conversion

OPA104BM can serve as the transimpedance element in precision current-to-voltage converters for picoamp-level or microamp-level currents. The specified 0.15 pA input bias current is small relative to many sensor-generated currents, helping preserve measurement resolution. A practical implementation combines a feedback resistor with a compensation capacitor to control bandwidth and prevent instability. Because the TO-99-8 package is through-hole, it may also simplify prototyping in laboratory and legacy industrial instruments, although PCB cleanliness remains essential when leakage and surface contamination affect the result.

🔧

Laboratory Instrumentation

OPA104BM is useful in laboratory amplifiers, buffer stages, null detectors, and precision analog measurement systems that benefit from a JFET input. Its single-amplifier configuration allows an engineer to tailor gain, bandwidth, offset adjustment, and compensation for one instrument channel without relying on a multi-amplifier package. The ±5 V to ±20 V operating range accommodates several conventional laboratory supply combinations. A metal-can through-hole format can suit handmade or long-life analytical equipment, but production designs should verify thermal behavior, connector grounding, and the exact manufacturer pin sequence.

📡

Low-Level Analog Signal Conditioning

OPA104BM is applicable to low-level analog signal conditioning when the source presents very high impedance and the amplifier should avoid loading it with bias current. A non-inverting or differential stage can use the amplifier's low input current while operating from split supplies, subject to common-mode and output-swing limits. Designers should select feedback resistors to balance Johnson noise against bandwidth, use short, guarded traces, and avoid nearby high-impedance contamination paths. The device is particularly attractive when the signal source is more sensitive to loading than to the amplifier's voltage-noise contribution.

🎧

Audio and Measurement Buffers

OPA104BM can be used as an input buffer or active gain stage in selected audio and measurement circuits where low input current is more important than minimum noise or maximum slew rate. Its JFET input avoids the comparatively high base current associated with bipolar-input amplifiers, making it suitable for high-impedance source networks. However, audio designs must verify bandwidth, output-drive capability, distortion, and output-voltage headroom for the selected supply rails. The 0.15 pA bias-current specification supports high-impedance buffering, while voltage-noise and gain-bandwidth characteristics determine its suitability for audio bandwidth.

خلاصه محصولات پیشنهادی

OPA104BM Texas Instruments استفاده‌شده در: Photodiode Signal Conditioning, High-Impedance Sensor Interface, Precision Current-to-Voltage Conversion, Laboratory Instrumentation, Low-Level Analog Signal Conditioning, Audio and Measurement Buffers OPA104CM Same-family TO-99 amplifier option استفاده‌شده در: Photodiode Signal Conditioning, Low-Level Analog Signal Conditioning OPA104DM Same-family TO-99 alternative استفاده‌شده در: High-Impedance Sensor Interface, Audio and Measurement Buffers OPA104TM Same-family package and pin configuration استفاده‌شده در: Precision Current-to-Voltage Conversion OPA104UM Same-family TO-99 option استفاده‌شده در: Laboratory Instrumentation
Where can I buy OPA104BM online?
The OPA104BM can be requested through the Request a Quote form on this page. The part is an 8-pin TO-99 JFET operational amplifier, and its availability and production quantity should be confirmed before committing a new production design. The distributor listing identifies Rochester Electronics as the supplier for this exact MPN.
What is the price of OPA104BM?
Use the Request a Quote form on this page for the current OPA104BM price and quantity availability. The product is listed as a single-circuit JFET amplifier in an 8-pin TO-99 package, with a specified input bias current of 0.15 pA. Quote requests avoid presenting a potentially stale catalog price as a current commitment.
What is the lead time for OPA104BM?
The current lead time for OPA104BM should be requested through the Request a Quote form on this page. Because this is an older TO-99 metal-can device, production status and delivery quantity may depend on the selected ordering code and manufacturer inventory. Confirm the lot availability, packaging quantity, and delivery schedule before releasing a build.
Is OPA104BM in stock?
The OPA104BM is shown as an in-stock component in the product listing, but live inventory should be confirmed through the Request a Quote form on this page. Stock can change with demand and order quantity. The exact listing identifies the OPA104BM as a JFET amplifier with one circuit in a TO-99-8 package.
What are the key specifications of OPA104BM that engineers should know?
The OPA104BM is a single JFET-input operational amplifier with 0.15 pA input bias current, an operating range of ±5 V to ±20 V, and an 8-terminal TO-99 metal-can package. These characteristics make it especially relevant to picoamp-leakage measurement, high-source-impedance signal conditioning, photodiode interfaces, and laboratory instrumentation using split supplies.
What is OPA104BM used for?
OPA104BM is used when a circuit requires very low input current and an amplifier with a JFET input stage. Its 0.15 pA input bias current is suitable for high-impedance sensors, photodetectors, current-to-voltage converters, and precision laboratory instruments. The ±5 V to ±20 V supply range supports both compact low-voltage systems and higher-voltage analog rails.
How does OPA104BM compare with a bipolar-input op amp?
OPA104BM differs primarily at the input stage because its JFET transistors provide a specified 0.15 pA input bias current. Bipolar-input amplifiers can offer low voltage noise and strong output drive, but their base currents may be excessive for picoamp or very-high-impedance measurements. The comparison must also account for offset, noise, bandwidth, slew rate, and output swing.
OPA104BM vs OPA104CM - which is better for my circuit?
OPA104BM and OPA104CM belong to the same OPA104 family, but the ordering suffix identifies different package or grade options rather than different amplifier functions. Choose the variant whose temperature grade, package construction, and lifecycle status match the production environment. Confirm the exact pin functions and operating limits against the manufacturer ordering information before substitution.
When should I choose OPA104BM over another JFET op amp?
Choose OPA104BM when the design needs a single-channel JFET amplifier, a 0.15 pA input bias current, operation from ±5 V to ±20 V, and a through-hole TO-99-8 footprint. Consider a different JFET amplifier when surface-mount assembly, multiple channels, lower noise, wider bandwidth, rail-to-rail output, or lower supply voltage is required.
Is OPA104BM suitable for high-impedance sensor measurement?
OPA104BM is suitable for many high-impedance sensor measurements because its specified input bias current is 0.15 pA. The sensor's leakage current, source impedance, input capacitance, and required settling time must still be compared with that bias current. Guarding and careful PCB layout are especially important when parasitic leakage could otherwise approach the signal current.
What can replace OPA104BM?
OPA104CM, OPA104DM, OPA104TM, and OPA104UM are same-family OPA104 options that can be evaluated as drop-in candidates because they retain the 8-terminal TO-99 footprint and core amplifier function. Verify temperature grade, package construction, offset, noise, bandwidth, and lifecycle status before production use; no cross-brand replacement is established by the available substitution records.
What is the best drop-in replacement for OPA104BM?
The closest drop-in starting point is another OPA104 ordering option in the same TO-99-8 family, such as OPA104CM. Drop-in status depends on more than package shape: verify pin functions, temperature range, offset voltage, input current, noise, bandwidth, supply range, and thermal requirements. Validate the selected option against the complete signal chain rather than relying on footprint compatibility alone.
Where can I download the OPA104BM datasheet PDF?
The OPA104BM datasheet archive entry is available through the linked documentation source on this page. Search the archive for OPA104 and use the manufacturer datasheet for the authoritative electrical characteristics, TO-99 pin descriptions, ordering codes, typical application circuits, and test conditions. The archive link is a documentation route rather than a component-sale listing.
Where can I find the OPA104BM pinout?
The OPA104BM uses an 8-terminal TO-99 package, and its pin functions must be assigned from the manufacturer pin-description table. The package is a round metal can with eight wire leads on a 4.7 mm pitch. Do not infer a modern SOIC or DIP numbering sequence; verify offset-null, supply, input, output, and compensation terminals directly from the OPA104 documentation.
Is there a Texas Instruments OPA104BM equivalent for a legacy design?
A Texas Instruments equivalent is available within the OPA104 ordering family, including OPA104CM, OPA104DM, OPA104TM, and OPA104UM as same-family drop-in candidates. These options preserve the TO-99-8 footprint and basic JFET amplifier function. A cross-brand equivalent has not been established by the available substitution records, so production approval should remain with the original manufacturer family until full specifications are checked.

داده‌های مرجع مهندسی برای OPA104BM — مقایسه، راهنمای طراحی و اطلاعات انطباق.

راهنمای انتخاب

Choose OPA104BM when the design requires a single-channel JFET-input amplifier with a specified 0.15 pA input bias current, operation from ±5 V to ±20 V, and a through-hole TO-99-8 footprint. It is a strong fit for photodetectors, electrochemical sensors, picoamp current measurement, and laboratory instrumentation where amplifier loading could dominate the error. OPA104CM, OPA104DM, OPA104TM, and OPA104UM are same-family candidates when a different ordering grade or package construction is needed; confirm their temperature, qualification, and lifecycle details before substitution. Choose another amplifier family when surface-mount assembly, multiple channels, lower voltage noise, higher bandwidth, faster slew rate, rail-to-rail output, or stronger output-current capability is more important than minimum input bias current. Footprint compatibility alone is insufficient for a safe replacement.

مقایسه با جایگزین‌ها

پارامتر این محصول OPA104CM OPA104DM OPA104TM OPA104UM OPA104BM
Brand Texas Instruments Texas Instruments Texas Instruments Texas Instruments Texas Instruments Texas Instruments
Package TO-99-8 metal can TO-99-8 metal can TO-99-8 metal can TO-99-8 metal can TO-99-8 metal can TO-99-8 metal can
Number of Terminals 8 terminals 8 terminals 8 terminals 8 terminals 8 terminals 8 terminals

تفاوت‌های کلیدی

  • Exceptionally low specified input bias current for precision high-impedance measurement (در مقابلOPA104CM)
  • Wide split-supply operating range (در مقابلOPA104DM)
  • Single-amplifier 8-terminal TO-99 format (در مقابلOPA104TM)

یادداشت‌های طراحی

Keep the OPA104BM input nodes physically short and isolate them from high-impedance leakage paths. Use a guarded input trace or guard ring where practical, remove flux residue, and avoid nearby switching nodes or exposed high-impedance test points. Because the specified input bias current is 0.15 pA, PCB contamination and surface leakage can be comparable to the intended input current and degrade measurement accuracy.

Do not assume that the TO-99-8 package follows a modern DIP numbering sequence. Assign every terminal, including offset-null and compensation functions, from the manufacturer pin-description table. Incorrect lead assignment can place supply voltage on an input, prevent normal operation, or damage the amplifier. Also verify that the selected feedback network remains stable with the input capacitance present in the intended layout.

The OPA104BM operates from ±5 V to ±20 V, so the supply rails must remain within that range under startup, transient, and fault conditions. Use local supply bypassing and adequate decoupling at the device pins, with routing that minimizes loop area. For transimpedance applications, begin with a conservative feedback capacitor and increase bandwidth only after checking stability against detector capacitance and board parasitics.

اطلاعات انطباق

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
بدون سرب
Unknown
بدون هالوژن
Unknown
مواد معدنی درگیری
Unknown

Compliance declarations are not stated in the manufacturer or distributor records for this exact MPN. AEC-Q100 is not applicable because the OPA104BM is an instrumentation amplifier rather than an automotive-qualified device.

جستجوهای مرتبط

OPA104BM datasheet OPA104BM pinout OPA104BM datasheet pdf OPA104BM TO-99-8 OPA104BM 0.15 pA OPA104BM ±5V to ±20V OPA104BM equivalent OPA104BM replacement OPA104BM cross reference OPA104BM vs OPA104CM Texas Instruments OPA104BM OPA104BM photodiode amplifier OPA104BM high impedance sensor OPA104BM price OPA104BM stock

قطعات و اصطلاحات مرتبط

Texas Instruments Burr-Brown OPA104BM OPA104CM OPA104DM OPA104TM OPA104UM OPA104 JFET operational amplifier operational amplifier analog amplifier IC analog signal-chain IC semiconductor TO-99-8 TO-99 metal-can package through-hole package input bias current input offset voltage gain bandwidth product common-mode input voltage range output voltage swing transimpedance amplifier photodiode signal conditioning high-impedance sensor interface laboratory instrumentation
استعلام قیمت سریع RFQ