AD515LH - 8-Pin Precision Operational Amplifier | Analog Devices
Référence : AD515LH ✓ ActifAD515LH Présentation
An operational amplifier is a voltage-gain amplifier intended for open-loop and feedback operation. Its inverting and non-inverting inputs compare two signals, while the output drives the difference between them with the polarity selected by the feedback network. When negative feedback is applied, the closed-loop behavior is primarily determined by external resistors and stable passive components. This makes precision op-amps useful where signal gain, input impedance, offset behavior, and output drive must be evaluated as a complete circuit.
The AD515LH is specified as a commercial-grade part with 8 wire terminals in a round metal-can package. The listed nominal supply voltage of 15 V places it among conventional dual-supply precision-amplifier designs. Its maximum input offset voltage of 1000 uV is an important selection criterion because the input offset error can appear directly at the output of a low-gain precision stage. Designers should include offset and bias-current effects in their error budget rather than treating the amplifier as an ideal component.
The AD515LH is identified in available replacement information as an older AD515-series device, and OPA128 is listed as a replacement for it. Replacement selection requires comparison of package lead assignment, supply range, input offset voltage, input bias current, input voltage range, noise, slew rate, supply current, and operating temperature. A device with a matching package can still require circuit changes if its electrical limits or pin functions differ. The manufacturer datasheet and the pin-description table should be the authority for each replacement.
Typical uses include precision current-to-voltage conversion, low-level transducer amplification, laboratory measurement front ends, feedback control loops, and signal-conditioning modules. In these applications, the external feedback network establishes gain, while layout and guarding become increasingly important as source impedance and required accuracy rise. Stable reference components, short sensitive traces, and careful treatment of ground returns can prevent parasitic effects from overwhelming the intrinsic amplifier performance.
For a new design, verify the exact supply voltage, common-mode input range, output swing, operating temperature range, and electrical limits for the selected ordering code. When replacing an installed AD515LH, compare every lead against the replacement data sheet and account for obsolete-part risk, component tolerances, and any changes in stability or compensation requirements. Use the Request a Quote form on this page for current sourcing information.
This page combines package and sourcing information with a focused drop-in comparison, selection guidance, and practical engineering notes. It distinguishes confirmed electrical attributes from parameters that require direct manufacturer-datasheet confirmation, helping engineers assess the AD515LH for legacy repair, redesign, and precision-signal-chain requirements.
Alternatives de remplacement direct pour AD515LH — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.
AD549LHZ
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
AD504LHZ
✅ Remplacement direct ⚠️ Spécifications non vérifiées📋 Alternative de référence (hors catalogue)
AD547LHZ
✅ Remplacement direct ⚠️ Spécifications non vérifiées📋 Alternative de référence (hors catalogue)
AD548LHZ
✅ Remplacement direct ⚠️ Spécifications non vérifiées📋 Alternative de référence (hors catalogue)
OPA128
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
AD515LH Valeurs maximales et caractéristiques électriques
| Amplifier Type | Operational Amplifier |
| Number of Terminals | 8 |
| Temperature Grade | Commercial |
| Terminal Form | Wire |
| Package Shape | Round |
| Nominal Supply Voltage | 15 V |
| Maximum Input Offset Voltage | 1000 uV |
| Circuit Count | 1 amplifier |
| Type de montage | Through-hole wire lead |
Guide de configuration des broches du AD515LH round
Configuration des broches du AD515LH (boîtier round). Ce composant analogique comporte des broches d'entrée, de sortie et d'alimentation. Consultez la fiche technique du fabricant pour les configurations des broches d'annulation d'offset, de compensation et d'activation. Idéal pour le conditionnement de signaux et les circuits amplificateurs.
Aucune donnée de brochage détaillée disponible pour AD515LH.
Consultez la fiche technique pour la configuration complète des broches.
Applications typiques
AD515LH convient pour 6 applications: Precision Transducer Measurement, Low-Level Signal Conditioning, Current-to-Voltage Conversion, Laboratory Instrumentation Front End, Feedback Control Loop, Legacy Instrumentation Repair.
Precision Transducer Measurement
The AD515LH fits a precision transducer-amplifier position when the circuit must amplify a small differential sensor signal and the design can accept the listed 1000 uV maximum input offset voltage. Its 15 V nominal supply fits conventional dual-rail instrumentation architectures, while the single amplifier provides a straightforward differential input stage. The external feedback resistors establish the conversion gain, so their tolerance and temperature coefficient should be included in the measurement uncertainty. Source impedance is equally important: bias-current error can be significant with high-impedance sensors, so the input bias current and common-mode range must be confirmed from the manufacturer data sheet before finalizing the circuit.
Low-Level Signal Conditioning
The AD515LH is suitable for a low-level signal-conditioning channel when modest offset contribution is acceptable and the desired closed-loop gain can be implemented with stable feedback components. The confirmed 1000 uV maximum input offset voltage is the primary error figure to place into the channel error budget, alongside resistor mismatch and source impedance effects. Its single-amplifier configuration allows a compact implementation around one device rather than requiring separate input and output stages. Check the amplifier's input common-mode range against the sensor's full output span and verify output swing at the required load, because the nominal 15 V supply alone does not describe either operating limit.
Current-to-Voltage Conversion
AD515LH can form the active element of a precision current-to-voltage converter when the target signal is generated by a photodiode, sensor, or resistive branch. A transimpedance circuit places feedback resistance from output to the inverting input, converting input current into output voltage while the non-inverting input establishes the reference. The candidate's 8-terminal round package provides a conventional through-hole implementation, but parasitic capacitance and board leakage become increasingly important as feedback resistance rises. Verify input bias current and input voltage noise in the data sheet, keep the summing node compact, and include guard structures where the required precision cannot tolerate leakage from contaminated or humid board surfaces.
Laboratory Instrumentation Front End
The AD515LH is appropriate for a laboratory instrumentation front end where a single precision amplifier must process a bipolar or referenced low-level signal. Its commercial-grade designation and 15 V nominal supply make it relevant to conventional bench equipment built around positive and negative rails. The design should explicitly budget the 1000 uV maximum input offset voltage and confirm that input bias current is low enough for the source impedance. Feedback-component selection, grounding, and guarding can matter more than nominal amplifier speed in a DC measurement path, especially when the output is digitized by a low-resolution converter or used for drift-sensitive calibration.
Feedback Control Loop
The AD515LH may be used in a feedback-control loop where low-level error signals must be amplified around a bias point and the loop bandwidth remains below the amplifier's verified stability and slew-rate capabilities. The 15 V nominal supply supports ordinary dual-supply control electronics, while the single amplifier can implement an inverting, non-inverting, or differential configuration. Before selecting it, compare the 1000 uV maximum input offset voltage against the minimum control error that the system can tolerate. Check output-current capability, capacitive-load stability, and recovery behavior against the driven plant, and ensure the feedback components are positioned to minimize added phase delay.
Legacy Instrumentation Repair
AD515LH is especially relevant to repairing legacy 8-pin round-package instrumentation in which changing the PCB land pattern is undesirable and the original amplifier's exact ordering code has become difficult to obtain. Its commercial grade, 8 wire terminals, and 15 V nominal supply identify the legacy circuit class, but the replacement decision must preserve the original lead functions and electrical behavior. OPA128 is identified as a replacement candidate, while AD549LHZ can serve as another same-package precision-amplifier comparison. Validate either choice against offset voltage, bias current, supply limits, output swing, and stability before installation, and retain the original part when its measured performance is uniquely required.
Données de référence d'ingénierie pour AD515LH — comparaison, recommandations de conception et informations de conformité.
Guide de sélection
Comparaison avec les alternatives
| Paramètre | Ce produit | AD549LHZ | AD504LHZ | AD547LHZ | AD548LHZ | OPA128 |
|---|---|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Texas Instruments |
| Package | 8-terminal round wire-lead package | TO-99-8 | TO-99-8 | TO-99-8 | TO-99-8 | TO-99-8 |
| Number of Circuits | 1 | 1 | 1 | 1 | 1 | 1 |
| Replacement Status | AD515LH | Nearby precision-amplifier comparison | Low-bias-current precision-amplifier alternative | Low-bias-current precision-amplifier alternative | Low-bias-current precision-amplifier alternative | Explicitly identified as an AD515LH replacement |
Principaux différenciateurs
- Legacy-compatible commercial precision-amplifier package (vs OPA128)
- Lower maximum input offset voltage than the AD549LHZ comparison (vs AD549LHZ)
- Same-package legacy continuity (vs AD547LHZ)
- Explicit replacement path with package compatibility (vs OPA128)
Notes de conception
Do not treat every AD515-family ordering code as automatically interchangeable. The AD515LH is identified as a commercial-grade, 8-terminal wire-lead device with a 15 V nominal supply and 1000 uV maximum input offset voltage. Before replacing it, compare all eight lead functions and verify the replacement's supply range, common-mode range, output swing, input bias current, and offset voltage. A package outline match alone does not establish electrical compatibility.
Keep the amplifier's inverting-input and feedback nodes physically compact, especially in a transimpedance or high-gain configuration. Route sensitive input conductors away from power-switching nodes and provide a clean ground-return path beneath the measurement circuit. Guarding may be necessary when source impedance is high or board contamination can create leakage comparable with the specified input-bias-current error. Confirm the exact input-bias-current limit in the manufacturer data sheet before fixing the required board cleanliness level.
Use precision feedback resistors and include their tolerance and temperature coefficient in the closed-loop accuracy calculation. The AD515LH's listed maximum input offset voltage is 1000 uV, so for a non-inverting stage with gain G, its maximum direct output contribution is the offset multiplied by G. This calculation is an estimate based on the published maximum offset and the selected noise gain; verify actual accuracy through circuit simulation and measurement using the final source and load conditions.
Informations de conformité