Analog Devices

AD623BNZ - Rail-to-Rail Instrumentation Amplifier | Analog Devices

Référence : AD623BNZ ✓ Actif
2.7 V to 12 V Vdss 8-pin PDIP Package
MOQ : 1 |

AD623BNZ Présentation

The Analog Devices AD623BNZ is a single-supply, rail-to-rail instrumentation amplifier with a 2.7 V to 12 V operating supply, 800 kHz bandwidth, 0.3 V/µs slew rate, and 100 µV maximum input offset voltage specification. The device is offered in an 8-pin PDIP package and is designed for precision signal conditioning when low cost, low power, and single-supply operation are important.

An instrumentation amplifier is a differential-input signal-conditioning IC that amplifies the voltage difference between two inputs while providing high input impedance and accurate differential gain. Within the analog signal-chain hierarchy, an instrumentation amplifier combines input-stage behavior, differential amplification, and output buffering in one package. It is commonly used where a small sensor signal must be measured accurately in the presence of common-mode voltage, source impedance, or grounding constraints.

The AD623 supports single-supply operation from 2.7 V to 12 V and also supports dual supplies. Its rail-to-rail output allows the output to approach the available supply range, improving utilization of limited power budgets. A user-programmable gain resistor provides gain adjustment, while the 800 kHz bandwidth supports signals extending well above audio frequency. The 0.3 V/µs slew rate provides useful response capability for moderate-bandwidth measurement systems.

The integrated three-op-amp architecture supports differential input sensing while maintaining high common-mode rejection when component matching and resistor accuracy are adequate. Gain is established with an external resistor rather than a fixed internal network, allowing the circuit designer to select sensitivity according to sensor output, analog input range, and required resolution. Careful reference-grounding and resistor selection remain essential because gain accuracy and common-mode rejection depend on these external implementation details.

Typical uses include bridge-transducer excitation and sensing, biomedical instrumentation, current monitoring, industrial process measurement, sensor interfaces, and portable data-acquisition systems. In a bridge circuit, the AD623 measures differential millivolt-level excitation changes while rejecting much of the common supply voltage. In a current-shunt monitor, it amplifies the voltage generated across the shunt without substantially loading the measured conductor.

Design with the 2.7 V to 12 V supply limits in mind, including input and output headroom at the selected supply voltage. Place bypass capacitors close to the supply pins, use a clean ground reference for the measurement system, and verify that source impedance and gain-resistor values do not compromise accuracy. The rail-to-rail output simplifies low-voltage operation but does not eliminate the need to check output swing under load.

This page combines the AD623BNZ electrical characteristics, package information, application guidance, comparison parameters, and verified replacement considerations to support faster component evaluation and PCB design.

Alternatives de remplacement direct pour AD623BNZ — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.

Variantes de cette série

Modèles de la même série directement compatibles avec AD623BNZ (même facteur de forme et même empreinte) — différant par Gain Programming, Package, Product Type.

Analog Devices
Gain Programming: Single external gain-set resistor
Package: 8-PDIP
Product Type: Instrumentation amplifier
Comparer avec AD623BNZ →

AD623ANZ

✅ Remplacement direct ⚠️ Spécifications non vérifiées
Analog Devices
📦 8-pin PDIP
Instrumentation amplifier · 1 circuit · 2.7 V to 12 V · 3 V to 12 V · Supported · Rail-to-rail · Single external gain-set resistor · 8-PDIP

Contactez-nous pour le prix

Voir la fiche technique →

AD623BNZ Valeurs maximales et caractéristiques électriques

Product Type Single-circuit instrumentation amplifier
Supply Voltage Range 2.7 V to 12 V
Single-Supply Operation Supported
Dual-Supply Operation Supported
Output Swing Rail-to-rail
Bandwidth 800 kHz
Slew Rate 0.3 V/µs
Input Offset Voltage 100 µV maximum
Number of Amplifiers 1 circuit
Gain Programming User-programmable resistor
Boîtier 8-pin PDIP
Nombre de broches 8 pins
Type de montage Through-hole PDIP

Guide de configuration des broches du AD623BNZ 8-pin pdip

Configuration des broches du AD623BNZ (boîtier 8-pin pdip). Ce composant analogique comporte des broches d'entrée, de sortie et d'alimentation. Consultez la fiche technique du fabricant pour les configurations des broches d'annulation d'offset, de compensation et d'activation. Idéal pour le conditionnement de signaux et les circuits amplificateurs.

Schéma de brochage du boîtier 8-pin pdip pour le AD623BNZ

Aucune donnée de brochage détaillée disponible pour AD623BNZ.

Consultez la fiche technique pour la configuration complète des broches.

Applications typiques

AD623BNZ convient pour 6 applications: Bridge Sensor Signal Conditioning, Portable Biomedical Sensor Interface, Industrial Current-Shunt Monitoring, Process Pressure and Flow Measurement, Portable Data Acquisition, Balanced Audio Measurement.

🏭

Bridge Sensor Signal Conditioning

The AD623BNZ fits strain-gauge, load-cell, and resistive bridge interfaces because it amplifies the small differential voltage generated by changes in bridge resistance. Its 2.7 V to 12 V supply range supports compact low-voltage measurement systems, while the 800 kHz bandwidth comfortably covers many static and dynamic mechanical measurements. The bridge excitation defines the available differential signal, so gain must be selected to keep the output within the rail-to-rail swing range. Use a clean reference ground and place the gain resistor where its value and tolerance can be controlled accurately.

💊

Portable Biomedical Sensor Interface

The AD623BNZ is suitable for portable biomedical sensing when the measured signal is differential and the system requires rail-to-rail output from a low-voltage supply. Operation down to 2.7 V supports battery-powered instrumentation, and the 800 kHz bandwidth accommodates many physiological and biosensor signals. The 100 µV maximum offset specification can be important when resolving small sensor outputs, although electrode impedance, patient protection, isolation, leakage, and medical qualification require separate evaluation. A high-impedance source and carefully grounded reference are especially important for low-level bioelectric measurements.

⚡

Industrial Current-Shunt Monitoring

The AD623BNZ can amplify the differential voltage across a current-sense shunt without directly interrupting the measured current path. Its differential-input architecture reduces sensitivity to the supply rail common to both shunt terminals, and the 0.3 V/µs slew rate supports moderate transient response. The 2.7 V to 12 V range supports both compact control systems and higher-voltage industrial rails. Select gain so that maximum expected current remains inside the output-swing range, and use Kelvin routing to avoid including copper and connector resistance in the measurement.

🏭

Process Pressure and Flow Measurement

The AD623BNZ is appropriate for process-control front ends that receive low-level differential signals from pressure, level, or flow transmitters. The instrumentation-amplifier configuration handles the difference between paired sensor outputs while rejecting much of their common-mode voltage. Its rail-to-rail output improves signal range in 3.3 V and 5 V systems, and the 800 kHz bandwidth is suitable for many flow and pressure loops without requiring a high-speed amplifier. Validate the transmitter output range, grounding method, and isolation requirements before connecting field wiring to the measurement circuit.

🖥️

Portable Data Acquisition

The AD623BNZ supports compact data-acquisition modules that measure sensor outputs under a 2.7 V to 12 V supply budget. Single-supply operation reduces system complexity, while rail-to-rail output permits the converter to use most of the available signal range. The 800 kHz bandwidth is suitable for many sensor channels requiring accurate amplification rather than high-frequency signal capture. The external gain resistor makes sensitivity easy to adapt across channels, although resistor tolerance and drift should be included in the total measurement uncertainty calculation.

🎧

Balanced Audio Measurement

The AD623BNZ can condition balanced audio or other differential signals when a single-supply measurement system is preferred. Its rail-to-rail output is useful in 5 V test equipment, and the 800 kHz bandwidth covers the full audio band with additional margin. The differential architecture helps reject common-mode hum or ground-potential differences that could otherwise affect the result. Use a stable gain resistor, maintain symmetrical input routing, and verify that the source impedance does not degrade CMRR or create excessive gain error.

What is the AD623BNZ?
The AD623BNZ is a single-circuit, rail-to-rail instrumentation amplifier from Analog Devices. According to the manufacturer datasheet, it operates from 2.7 V to 12 V and is packaged in an 8-pin PDIP. The device is intended for differential signal conditioning in sensor, bridge, biomedical, industrial, and portable measurement systems.
What is the operating voltage range of AD623BNZ?
The AD623BNZ operates from 2.7 V to 12 V and supports single- or dual-supply operation. The Analog Devices product page identifies the same 2.7 V to 12 V range for the AD623 family. Rail-to-rail output operation allows the output to use more of the available supply voltage than a fixed-output amplifier.
What are the key specifications of AD623BNZ that engineers should know?
The AD623BNZ provides an 800 kHz bandwidth, 0.3 V/µs slew rate, and 100 µV maximum input offset voltage specification. The manufacturer describes the AD623 as a low-cost, single-supply instrumentation amplifier with rail-to-rail output, user-programmable gain, and operation from 2.7 V to 12 V in an 8-pin PDIP package.
Where can I download the AD623BNZ datasheet PDF?
The official AD623BNZ datasheet PDF is available from Analog Devices at https://www.analog.com/media/en/technical-documentation/data-sheets/AD623.pdf. The document covers the AD623 family, including supply options, gain programming, electrical characteristics, application information, and package details. Use the manufacturer pin-description table when assigning PCB connections.
Where can I find the AD623BNZ pinout?
The AD623BNZ pinout is identified in the Analog Devices AD623 datasheet, which covers the 8-pin PDIP configuration. The public product material confirms an 8-pin PDIP package but does not provide a numbered pin table in its product summary. Use the manufacturer datasheet pin-description table and package drawing to verify every connection before PCB layout.
Can AD623BNZ replace AD623ANZ?
AD623ANZ is the closest same-package family alternative because it uses the same 8-pin PDIP AD623 architecture and pin assignment. The difference is the internal grade, so the replacement decision must include a comparison of offset voltage and other grade-specific limits before production use. Confirm the complete parameter table and qualification requirements for the intended application.
What can replace AD623BNZ?
AD623ANZ is a candidate for the same AD623 family in an 8-pin PDIP package, but it changes the internal grade. A verified cross-brand, pin-to-pin replacement with complete parametric confirmation was not identified. Because instrumentation-amplifier substitution affects accuracy, common-mode rejection, gain range, and supply compatibility, do not approve a replacement from function alone.
Is AD623BNZ suitable for bridge sensor measurements?
Yes, AD623BNZ is suitable for bridge sensor measurements when its supply range, bandwidth, and offset-voltage requirements match the circuit. Its differential-input architecture is appropriate for small bridge outputs, while the 800 kHz bandwidth supports many low-frequency strain and pressure signals. Gain is programmed with an external resistor and must be selected against the bridge excitation and input range.
Is AD623BNZ suitable for a 5 V sensor interface?
Yes, AD623BNZ is compatible with a 5 V system because its operating supply range extends from 2.7 V to 12 V. Rail-to-rail output improves headroom at this voltage, but the output must still remain within the loaded output-swing limits. Input common-mode range, gain, and reference-ground placement also require verification for the specific sensor.
AD623BNZ vs AD623ANZ — which is better for precision measurement?
AD623BNZ is the B-grade version, while AD623ANZ is the A-grade version of the same instrumentation-amplifier family in an 8-pin PDIP package. Choose by comparing the grade-specific offset-voltage limits and any other changed ratings in the manufacturer datasheet. The lower-offset A grade may be preferable for precision systems when the extra grade is needed.
When should I choose AD623BNZ over AD623ANZ?
Choose AD623BNZ when the B-grade offset-voltage specification satisfies the measurement budget and the lower-cost B grade is appropriate for the application. Choose AD623ANZ when the A-grade limit provides useful additional accuracy margin. Both use the same family architecture, so input common-mode range, supply compatibility, bandwidth, and external gain-resistor design must also be checked.
Where can I buy AD623BNZ online?
Use the Request a Quote form on this page to request AD623BNZ availability, pricing, and lead time from XAIPART. The AD623BNZ is an active Analog Devices catalog part with an 8-pin PDIP package. A quote request allows the exact suffix and package to be confirmed before ordering, which is important when production quantities are involved.
What is the lead time for AD623BNZ?
Lead time depends on current inventory, order quantity, and the confirmed AD623BNZ suffix. Submit a request through the Request a Quote form on this page to obtain the current production lead time and minimum-order information. For prototype assembly, requesting the exact 8-pin PDIP package in the same order reduces package-mismatch risk.
Is AD623BNZ in stock?
Current AD623BNZ stock should be confirmed through the Request a Quote form on this page rather than inferred from a listing page. Stock can vary with quantity and assembly requirements. Specify the required quantity, packaging method, and whether RoHS documentation is needed when requesting the quotation.
What are the AD623BNZ power and thermal considerations?
AD623BNZ supply voltage must remain between 2.7 V and 12 V, and bypass capacitors should be placed close to the power pins. Its operating temperature range and detailed power-dissipation limits are not stated in the product summary. Review the manufacturer datasheet’s absolute-maximum and thermal tables for the final ambient temperature, copper area, and package orientation.
How do I calculate AD623BNZ gain?
The AD623BNZ uses a user-programmable gain resistor. Follow the gain equation and reference-resistor guidance in the Analog Devices datasheet, then calculate the resistor tolerance contribution to total gain error. Also check that the selected gain and input signal keep the amplifier output inside its rail-to-rail operating limits under the expected load.

Données de référence d'ingénierie pour AD623BNZ — comparaison, recommandations de conception et informations de conformité.

Guide de sélection

Choose AD623BNZ when its 100 µV maximum input offset voltage meets the measurement-error budget and the application benefits from its 2.7 V to 12 V supply range, rail-to-rail output, and 800 kHz bandwidth. It is particularly suitable for bridge sensors, current-shunt monitoring, portable acquisition, and low-voltage industrial interfaces. Choose AD623ANZ when the A-grade 25 µV maximum offset voltage provides useful accuracy margin and the grade change does not conflict with sourcing requirements. Both alternatives use the same 8-pin PDIP footprint and retain the same supply range, bandwidth, slew rate, and gain architecture. No verified cross-brand drop-in candidate was identified, so changing manufacturers should not be treated as an automatic PCB-compatible substitution. Before approving any alternative, verify the full electrical limits, pin assignment, temperature range, gain equation, common-mode range, and lifecycle requirements.

Comparaison avec les alternatives

Paramètre Ce produit AD623ANZ
Brand Analog Devices Analog Devices
Package 8-pin PDIP 8-pin PDIP
Product Type Instrumentation amplifier Instrumentation amplifier
Number of Circuits 1 circuit 1 circuit
Supply Voltage Range 2.7 V to 12 V 2.7 V to 12 V
Output Swing Rail-to-rail Rail-to-rail
Bandwidth 800 kHz 800 kHz
Slew Rate 0.3 V/µs 0.3 V/µs
Input Offset Voltage 100 µV maximum 25 µV maximum
Gain Programming User-programmable resistor User-programmable resistor

Principaux différenciateurs

  • Single-supply operation extends to 2.7 V (vs AD623ANZ)
  • Rail-to-rail output improves low-voltage signal range (vs AD623ANZ)
  • 8-pin PDIP supports through-hole assembly (vs AD623ANZ)

Notes de conception

Place the supply bypass capacitor immediately beside the AD623BNZ supply and ground pins, with a short, low-inductance return path. The AD623 datasheet specifically recommends capacitive decoupling close to the power pins. Keep sensitive gain-resistor and feedback paths away from switching nodes and high-current return paths to avoid converting supply and ground disturbances into measurement error.

Do not assume that rail-to-rail output means the output can reach either supply rail under every load. Check the loaded output-swing limits, input common-mode range, and gain calculation from the manufacturer datasheet. At 2.7 V or 3.3 V operation, the available signal span and external gain resistor may need more conservative values than at 5 V or 12 V.

Route the two differential inputs as a balanced pair and connect their returns without unintended loops. Use a single low-noise ground reference for the sensor and instrumentation amplifier unless the system design requires an isolation barrier. For a current shunt, use Kelvin connections so copper resistance and solder-joint resistance are not included in the measured shunt voltage.

Include gain-resistor tolerance and temperature coefficient in the error budget rather than relying only on the nominal gain equation. Differential input bias current and source-imbalance effects can create additional output error. Use a resistor value recommended by the manufacturer where practical, and verify the complete signal chain with the actual sensor source impedance and cable length.

Informations de conformité

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
Sans plomb
Unknown
Sans halogène
Unknown
Minerais de conflit
Unknown

Compliance status is not established in the product information available for the exact AD623BNZ suffix. Request current supporting declarations when ordering.

Recherches associées

AD623BNZ datasheet AD623BNZ pinout AD623BNZ datasheet pdf AD623BNZ equivalent AD623BNZ replacement AD623BNZ vs AD623ANZ AD623BNZ 8-PDIP AD623BNZ 800 kHz AD623BNZ price AD623BNZ stock Analog Devices AD623BNZ AD623BNZ bridge sensor amplifier

Composants & termes associés

Analog Devices AD623BNZ AD623ANZ AD623 instrumentation amplifier differential amplifier signal-conditioning IC analog signal chain rail-to-rail output single-supply operation dual-supply operation user-programmable gain common-mode rejection input offset voltage gain resistor bridge sensor load cell current shunt biomedical instrumentation industrial process measurement 8-pin PDIP DIP package family through-hole package surface-mount electronics 800 kHz bandwidth
RFQ de devis rapide
Renseignez tous les détails — notre équipe commerciale vous répondra sous 24 heures
Référence Fabricant Boîtier QTY Prix cible Total
✓
Devis envoyé !

Nous répondrons à votre e-mail sous 24 heures

1
RFQ envoyée
2
Devis reçu
3
Commande passée
4
Paiement
5
Expédié
6
Livré
Voir les détails de la RFQ