AD640BD - 120 MHz 50 dB Logarithmic Amplifier | Analog Devices
Référence : AD640BD ✓ ActifAD640BD Présentation
A logarithmic amplifier is a signal-chain component whose output represents the logarithm of its input amplitude rather than the input waveform itself. This makes the AD640 useful for power measurement, spectrum analysis, IF and RF level detection, receiver signal-strength indication, and instrumentation that must display or process level over a wide amplitude range. The AD640 belongs to the broader logarithmic-amplifier and special-purpose amplifier hierarchy.
The AD640 architecture uses five cascaded stages with 10 dB small-signal voltage gain and a -3 dB bandwidth of 350 MHz per stage. Each stage includes a full-wave detector whose output current depends on the absolute value of the stage input. The detector outputs are summed to create a logarithmic video output scaled at 1 mA per decade, or 50 µA per decade of input signal.
Successive detection allows the summed detector outputs to approximate a logarithmic response over the operating range. The device is laser calibrated to improve consistency between units. The Analog Devices product page states that one AD640 provides up to 50 dB of dynamic range from dc to 120 MHz, while two devices connected in cascade can provide up to 95 dB of dynamic range at reduced bandwidth.
Typical uses include broadband RF power detection, receiver AGC loops, oscilloscope and spectrum-analyzer auxiliary detectors, communication-system level monitoring, and wideband test equipment. Because the response is dc coupled, the AD640 can also detect very low-frequency or slowly varying envelope signals rather than only RF carrier envelopes.
The principal design consideration is bandwidth allocation. Each internal stage contributes 10 dB of gain and has a 350 MHz -3 dB bandwidth, but the assembled device is specified for 120 MHz operation. Output filtering is normally used to smooth the summed detector response, and system impedance, grounding, and decoupling must be controlled to preserve accurate logarithmic behavior at low signal levels.
Alternatives de remplacement direct pour AD640BD — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.
Aucune alternative de remplacement direct disponible pour ce produit.
Demander des alternativesAD640BD Valeurs maximales et caractéristiques électriques
| Device Type | DC-coupled demodulating logarithmic amplifier |
| Frequency Range | DC to 120 MHz |
| Dynamic Range | 50 dB |
| Cascade Dynamic Range | 95 dB with two devices at reduced bandwidth |
| Internal Stage Count | 5 cascaded amplifier/limiter stages |
| Small-Signal Voltage Gain | 10 dB per stage |
| Stage -3 dB Bandwidth | 350 MHz per stage |
| Output Scaling | 1 mA per decade (50 µA per decade) |
| Detection Scheme | Successive detection with full-wave detectors |
| Calibration | Laser calibrated |
| Courant d'alimentation | 2.3 mA |
| Boîtier | 20-lead ceramic dual in-line package (20-CDIP) |
| Type de montage | Through-hole |
| Circuit Count | 1 logarithmic amplifier per package |
| Statut RoHS | Supported |
| Input Coupling | DC-coupled |
Guide de configuration des broches du AD640BD 20-lead ceramic dual in-line package (20-cdip)
Configuration des broches du AD640BD (boîtier 20-lead ceramic dual in-line package (20-cdip)). Ce composant analogique comporte des broches d'entrée, de sortie et d'alimentation. Consultez la fiche technique du fabricant pour les configurations des broches d'annulation d'offset, de compensation et d'activation. Idéal pour le conditionnement de signaux et les circuits amplificateurs.
Aucune donnée de brochage détaillée disponible pour AD640BD.
Consultez la fiche technique pour la configuration complète des broches.
Applications typiques
AD640BD convient pour 6 applications: Broadband RF Power Detection, Receiver Automatic Gain Control Loop, Spectrum Analyzer Auxiliary Log Detector, IF Channel Level Monitoring, Wideband Test and Measurement Instrumentation, High-Dynamic-Range Cascaded Detection.
Broadband RF Power Detection
The AD640BD is suited to broadband RF level detection because it combines dc-to-120 MHz operation with a 50 dB dynamic range. Its five cascaded stages detect the absolute value of the input signal and produce a summed video current at 1 mA per decade, allowing a receiver or instrument to represent a wide range of carrier amplitudes with one logarithmic transfer characteristic. In a practical implementation, the current is converted to voltage and low-pass filtered before digitizing. Designers should account for the 350 MHz -3 dB bandwidth of each internal stage and verify calibration accuracy near the lower signal limit, where the datasheet notes greater deviation from calibration.
Recommandé
Receiver Automatic Gain Control Loop
The AD640BD can serve as the detector inside a receiver automatic gain control loop because its output represents the logarithm of input amplitude rather than the RF waveform. The summing node therefore receives a control-friendly level signal covering up to 50 dB from one device, simplifying the relationship between detected amplitude and loop correction. Place a suitable low-pass filter after the video output to remove the detected ripple, then compare the filtered level with a reference in the loop amplifier. Two cascaded devices extend the range to 95 dB at reduced bandwidth, but temperature matching and gain calibration become increasingly important as the system approaches the low-level noise floor.
Recommandé
Spectrum Analyzer Auxiliary Log Detector
An AD640BD can provide auxiliary logarithmic detection in spectrum-analysis or surveillance equipment, giving a direct indication of signal level across a wide instantaneous-frequency range. Its dc-coupled 120 MHz specification supports instruments that examine baseband through UHF signals, while the summed detector output allows display electronics to work with a compressed logarithmic response rather than a linear RF envelope. A transimpedance stage converts the 1 mA-per-decade video current into a voltage suitable for an ADC. Calibration tables may be needed near the lower detection limit, where the AD640 datasheet reports visible deviation for different input waveforms, particularly in pulse-oriented measurements.
Recommandé
IF Channel Level Monitoring
The AD640BD is useful when an IF chain needs continuous level monitoring without disrupting the signal path. Its dc-coupled logarithmic response allows the detector to observe the absolute amplitude of an IF waveform and present a compressed control or measurement signal spanning up to 50 dB. This can support carrier-quality monitoring, adaptive front-end control, and fault detection in communication equipment. The ceramic 20-CDIP package is through-hole, allowing a conventional leaded footprint with adequate spacing between sensitive input and output routes. Designers should keep the detector input return path short and verify that the chosen downstream filter preserves the intended response time without introducing excessive ripple.
Recommandé
Wideband Test and Measurement Instrumentation
The AD640BD supports laboratory and field-test instruments that must measure changing signal amplitudes from dc through 120 MHz. Instead of switching between multiple front ends, an instrument can use the device's 50 dB single-stage dynamic range to derive a logarithmic indication directly from the waveform amplitude. The 1 mA-per-decade output scale is convenient for transimpedance conversion and digital calibration. When testing pulsed or complex waveforms, include per-waveform calibration checks because the manufacturer datasheet notes that low-level displacement can vary among different input shapes. Temperature stability and component matching become important if the instrument must maintain accuracy over a broad ambient range.
Recommandé
High-Dynamic-Range Cascaded Detection
Two AD640BD devices can be cascaded to increase the available dynamic range from 50 dB to as much as 95 dB, making the arrangement useful for wideband receivers that must observe weak and strong signals without changing gain. The first device detects and compresses the input, and the second detects the resulting logarithmic video signal. Because cascade operation is specified at reduced bandwidth, the usable frequency range must be confirmed for the complete chain. Matching the devices closely and maintaining similar operating temperatures improves consistency between the two calibration curves. Practical layouts should separate the sensitive detector input from the high-level video output and provide low-impedance grounding to avoid adding error to the logarithmic sum.
Recommandé
Récapitulatif des produits recommandés
Données de référence d'ingénierie pour AD640BD — comparaison, recommandations de conception et informations de conformité.
Guide de sélection
Notes de conception
Low-level calibration is the main measurement pitfall for the AD640. The manufacturer datasheet indicates that output displacement can differ among input waveforms between approximately -10 dBV and -40 dBV. Use calibration appropriate to the expected signal shape, verify offset at the lowest required input level, and avoid interpreting small residual deviations as a change in the true logarithmic slope.
Route the detector input and video output as sensitive high-frequency paths. Keep the input return connection short, provide a continuous ground plane, and separate the video output from the input node to reduce coupling. Because each internal stage has a 350 MHz -3 dB bandwidth, even though the complete device is specified to 120 MHz, high-value board effects should be checked with the final component and trace layout.
The summed video output is a current signal with a nominal scale of 1 mA per decade. Convert it to voltage with a suitable transimpedance network and then low-pass filter the result. Choose the filter cutoff from the required measurement bandwidth, not from the AD640's 120 MHz input bandwidth, and confirm that the amplifier and converter operate within their own input and output ranges.
Informations de conformité
The product listing identifies RoHS as supported. No verified REACH, halogen-free, conflict-minerals, or AEC-Q100 information was identified for the AD640BD.