Analog Devices

AD640BD - 120 MHz 50 dB Logarithmic Amplifier | Analog Devices

MPN: AD640BD ✓ فعال
10 dB per stage Vdss 2.3 mA Id 20-lead ceramic dual in-line package (20-CDIP) Package DC to 120 MHz Speed
حداقل سفارش: 1 |

AD640BD نمای کلی

The Analog Devices AD640BD is a monolithic, dc-coupled demodulating logarithmic amplifier providing 50 dB of dynamic range from dc to 120 MHz in a 20-lead ceramic dual in-line package. Its five cascaded amplifier and limiter stages each contribute 10 dB of small-signal gain, while five associated full-wave detectors generate an output proportional to the logarithm of the absolute input voltage.

A logarithmic amplifier is a signal-chain component whose output represents the logarithm of its input amplitude rather than the input waveform itself. This makes the AD640 useful for power measurement, spectrum analysis, IF and RF level detection, receiver signal-strength indication, and instrumentation that must display or process level over a wide amplitude range. The AD640 belongs to the broader logarithmic-amplifier and special-purpose amplifier hierarchy.

The AD640 architecture uses five cascaded stages with 10 dB small-signal voltage gain and a -3 dB bandwidth of 350 MHz per stage. Each stage includes a full-wave detector whose output current depends on the absolute value of the stage input. The detector outputs are summed to create a logarithmic video output scaled at 1 mA per decade, or 50 µA per decade of input signal.

Successive detection allows the summed detector outputs to approximate a logarithmic response over the operating range. The device is laser calibrated to improve consistency between units. The Analog Devices product page states that one AD640 provides up to 50 dB of dynamic range from dc to 120 MHz, while two devices connected in cascade can provide up to 95 dB of dynamic range at reduced bandwidth.

Typical uses include broadband RF power detection, receiver AGC loops, oscilloscope and spectrum-analyzer auxiliary detectors, communication-system level monitoring, and wideband test equipment. Because the response is dc coupled, the AD640 can also detect very low-frequency or slowly varying envelope signals rather than only RF carrier envelopes.

The principal design consideration is bandwidth allocation. Each internal stage contributes 10 dB of gain and has a 350 MHz -3 dB bandwidth, but the assembled device is specified for 120 MHz operation. Output filtering is normally used to smooth the summed detector response, and system impedance, grounding, and decoupling must be controlled to preserve accurate logarithmic behavior at low signal levels.

جایگزین‌های drop-in برای AD640BD — همان پکیج، سازگار پین‌به‌پین. قطعات با پکیج متفاوت که نیاز به تغییر PCB دارند مستثنی هستند.

هیچ جایگزین مستقیمی برای این محصول موجود نیست.

درخواست جایگزین

AD640BD حداکثر مقادیر مجاز و مشخصات الکتریکی

Device Type DC-coupled demodulating logarithmic amplifier
Frequency Range DC to 120 MHz
Dynamic Range 50 dB
Cascade Dynamic Range 95 dB with two devices at reduced bandwidth
Internal Stage Count 5 cascaded amplifier/limiter stages
Small-Signal Voltage Gain 10 dB per stage
Stage -3 dB Bandwidth 350 MHz per stage
Output Scaling 1 mA per decade (50 µA per decade)
Detection Scheme Successive detection with full-wave detectors
Calibration Laser calibrated
جریان تغذیه 2.3 mA
بسته‌بندی 20-lead ceramic dual in-line package (20-CDIP)
نوع نصب Through-hole
Circuit Count 1 logarithmic amplifier per package
وضعیت RoHS Supported
Input Coupling DC-coupled

راهنمای پیکربندی پین AD640BD 20-lead ceramic dual in-line package (20-cdip)

پیکربندی پین برای AD640BD (پکیج 20-lead ceramic dual in-line package (20-cdip)). این قطعه آنالوگ دارای پین‌های ورودی، خروجی و تغذیه است. برای پیکربندی‌های پین offset null، جبران‌سازی و فعال‌سازی به دیتاشیت سازنده مراجعه کنید. ایده‌آل برای مدارهای شرطی‌سازی سیگنال و تقویت‌کننده.

نمودار پین‌آوت پکیج 20-lead ceramic dual in-line package (20-cdip) برای AD640BD

داده پین‌آوت تفصیلی موجود نیست برای AD640BD.

به دیتاشیت برای پیکربندی کامل پین‌ها.

کاربردهای معمول

AD640BD مناسب است برای 6 کاربردs: Broadband RF Power Detection, Receiver Automatic Gain Control Loop, Spectrum Analyzer Auxiliary Log Detector, IF Channel Level Monitoring, Wideband Test and Measurement Instrumentation, High-Dynamic-Range Cascaded Detection.

🌐

Broadband RF Power Detection

The AD640BD is suited to broadband RF level detection because it combines dc-to-120 MHz operation with a 50 dB dynamic range. Its five cascaded stages detect the absolute value of the input signal and produce a summed video current at 1 mA per decade, allowing a receiver or instrument to represent a wide range of carrier amplitudes with one logarithmic transfer characteristic. In a practical implementation, the current is converted to voltage and low-pass filtered before digitizing. Designers should account for the 350 MHz -3 dB bandwidth of each internal stage and verify calibration accuracy near the lower signal limit, where the datasheet notes greater deviation from calibration.

📱

Receiver Automatic Gain Control Loop

The AD640BD can serve as the detector inside a receiver automatic gain control loop because its output represents the logarithm of input amplitude rather than the RF waveform. The summing node therefore receives a control-friendly level signal covering up to 50 dB from one device, simplifying the relationship between detected amplitude and loop correction. Place a suitable low-pass filter after the video output to remove the detected ripple, then compare the filtered level with a reference in the loop amplifier. Two cascaded devices extend the range to 95 dB at reduced bandwidth, but temperature matching and gain calibration become increasingly important as the system approaches the low-level noise floor.

📺

Spectrum Analyzer Auxiliary Log Detector

An AD640BD can provide auxiliary logarithmic detection in spectrum-analysis or surveillance equipment, giving a direct indication of signal level across a wide instantaneous-frequency range. Its dc-coupled 120 MHz specification supports instruments that examine baseband through UHF signals, while the summed detector output allows display electronics to work with a compressed logarithmic response rather than a linear RF envelope. A transimpedance stage converts the 1 mA-per-decade video current into a voltage suitable for an ADC. Calibration tables may be needed near the lower detection limit, where the AD640 datasheet reports visible deviation for different input waveforms, particularly in pulse-oriented measurements.

🏭

IF Channel Level Monitoring

The AD640BD is useful when an IF chain needs continuous level monitoring without disrupting the signal path. Its dc-coupled logarithmic response allows the detector to observe the absolute amplitude of an IF waveform and present a compressed control or measurement signal spanning up to 50 dB. This can support carrier-quality monitoring, adaptive front-end control, and fault detection in communication equipment. The ceramic 20-CDIP package is through-hole, allowing a conventional leaded footprint with adequate spacing between sensitive input and output routes. Designers should keep the detector input return path short and verify that the chosen downstream filter preserves the intended response time without introducing excessive ripple.

🖥️

Wideband Test and Measurement Instrumentation

The AD640BD supports laboratory and field-test instruments that must measure changing signal amplitudes from dc through 120 MHz. Instead of switching between multiple front ends, an instrument can use the device's 50 dB single-stage dynamic range to derive a logarithmic indication directly from the waveform amplitude. The 1 mA-per-decade output scale is convenient for transimpedance conversion and digital calibration. When testing pulsed or complex waveforms, include per-waveform calibration checks because the manufacturer datasheet notes that low-level displacement can vary among different input shapes. Temperature stability and component matching become important if the instrument must maintain accuracy over a broad ambient range.

✈️

High-Dynamic-Range Cascaded Detection

Two AD640BD devices can be cascaded to increase the available dynamic range from 50 dB to as much as 95 dB, making the arrangement useful for wideband receivers that must observe weak and strong signals without changing gain. The first device detects and compresses the input, and the second detects the resulting logarithmic video signal. Because cascade operation is specified at reduced bandwidth, the usable frequency range must be confirmed for the complete chain. Matching the devices closely and maintaining similar operating temperatures improves consistency between the two calibration curves. Practical layouts should separate the sensitive detector input from the high-level video output and provide low-impedance grounding to avoid adding error to the logarithmic sum.

What is the operating frequency range of the AD640BD?
The AD640BD operates from dc to 120 MHz and is specified to provide up to 50 dB of dynamic range across that range. According to the Analog Devices AD640 product page and the manufacturer datasheet, the device is a dc-coupled demodulating logarithmic amplifier, so it can respond to low-frequency envelope signals as well as RF waveforms up to 120 MHz.
Where can I download the AD640BD datasheet PDF?
The AD640BD datasheet PDF is available directly from Analog Devices at the manufacturer data-sheet URL listed on this page. The document is titled for the AD640 family and is identified as Data Sheet Rev. D on the manufacturer product page. It contains the stage architecture, detector characteristics, calibration information, electrical specifications, and application information needed for circuit design.
How much dynamic range does the AD640BD provide?
A single AD640BD provides up to 50 dB of dynamic range from dc to 120 MHz. Analog Devices states that two AD640 devices in cascade can provide up to 95 dB of dynamic range, although operation at reduced bandwidth. Each of the five internal stages contributes 10 dB of small-signal voltage gain and uses a full-wave detector.
What is the output scaling of the AD640BD logarithmic amplifier?
The AD640BD output is scaled at 1 mA per decade, equivalent to 50 µA per decade of input signal. The five full-wave detector outputs are summed to form this logarithmic video output. In a practical receiver, the current output is usually converted to a voltage and low-pass filtered to recover the slowly varying envelope.
How does the AD640BD detect low-level RF signals?
The AD640BD uses five cascaded dc-coupled amplifier/limiter stages, each with 10 dB of small-signal gain, followed by associated full-wave detectors. Each detector output depends on the absolute value of its stage input, and the five outputs are summed through a successive detection scheme. This architecture produces an output proportional to the logarithm of the input amplitude.
What are the key specifications engineers should know about the AD640BD?
The AD640BD is a monolithic dc-coupled demodulating logarithmic amplifier rated for dc to 120 MHz operation with 50 dB of dynamic range. It contains five cascaded stages, each providing 10 dB of small-signal gain and a 350 MHz -3 dB bandwidth. Its summed video output scales at 1 mA per decade, and the device is packaged in a 20-CDIP ceramic package.
Can two AD640BD devices increase the logarithmic detection range?
Yes. Analog Devices states that two AD640 devices in cascade can deliver up to 95 dB of dynamic range instead of the 50 dB available from one device. The tradeoff is reduced bandwidth, because the additional cascade stage adds signal-path bandwidth limitations. Both devices must also be carefully matched and temperature-tracked for accurate calibration across the full range.
Is the AD640BD suitable for RF power detection?
The AD640BD is suitable for RF power detection because it detects the absolute value of the input waveform and converts it into a logarithmic video output. Its dc-to-120 MHz range covers many IF and RF measurement applications, and the 50 dB single-device dynamic range accommodates signals spanning a broad amplitude interval. Output filtering and calibration are critical near the lower detection limit.
What should I consider when cascading two AD640BD amplifiers?
When cascading two AD640BD devices, expect up to 95 dB of combined dynamic range but reduced bandwidth compared with one device. The Analog Devices AD640 datasheet discusses calibration errors at low signal levels, so accurate measurement requires matched devices, careful temperature management, and verification of the system response. The 20-CDIP package also requires adequate through-hole spacing and thermal handling.
What is the difference between the AD640BD and the AD640 product family?
The AD640BD is the packaged 20-CDIP orderable version of the AD640 logarithmic-amplifier family. The family is specified for 120 MHz operation and 50 dB of dynamic range, while AD640BD denotes the particular ceramic dual in-line package configuration. The family also supports two-device cascade operation for up to 95 dB of dynamic range at reduced bandwidth.
Can the AD640BD replace another logarithmic amplifier on the same PCB?
The AD640BD should only replace another amplifier after its pinout, supply requirements, calibration behavior, and bandwidth have been checked against the original device. No verified pin-compatible substitute for the AD640BD appears in the available cross-reference results. Because this is a 20-CDIP through-hole device with tightly coupled signal-processing behavior, a functional equivalent is not automatically a drop-in replacement.
What is the best drop-in replacement for the AD640BD?
No verified drop-in replacement for the AD640BD was identified in the available manufacturer and cross-reference information. The device uses a 20-CDIP ceramic package and a specific five-stage successive-detection architecture, so substitute parts must be validated against pin assignment, supply voltage, calibration range, temperature stability, and bandwidth. Request a Quote on this page to discuss sourcing options for the exact AD640BD orderable configuration.
Where can I buy the AD640BD online?
You can request a quote for the AD640BD through the Request a Quote form on this page. The form supports current sourcing of the exact 20-CDIP orderable configuration without relying on a static price table. Confirm the manufacturer lead time, minimum order quantity, and delivery terms with the supplier before releasing the design to production.
What is the lead time for the AD640BD?
Current lead time for the AD640BD should be requested through the Request a Quote form on this page. Availability can change with the exact package configuration and order volume, so procurement should confirm the production status, quantity breaks, and expected delivery schedule in the quotation. The Analog Devices product page lists the part within the AD640 family documentation.
Is the AD640BD in stock?
Stock availability for the AD640BD changes with demand and the exact 20-CDIP configuration. Use the Request a Quote form on this page to request current availability, minimum order quantity, and lead time for your required quantity. Because availability is quote-confirmed rather than permanently guaranteed, plan schedule-critical procurement around the supplier's written confirmation.
Is the AD640BD an appropriate choice instead of a detector diode or discrete detector?
The AD640BD is appropriate when the design needs calibrated logarithmic response across a wide frequency span and amplitude range. Unlike a simple diode detector, it combines dc coupling, five gain-and-detector stages, a defined logarithmic video-output slope, and laser calibration. A detector diode or discrete arrangement may be simpler for one frequency band, but it does not provide the AD640BD's integrated 120 MHz bandwidth and 50 dB range.

داده‌های مرجع مهندسی برای AD640BD — مقایسه، راهنمای طراحی و اطلاعات انطباق.

راهنمای انتخاب

The AD640BD is the appropriate choice when a design requires an integrated, dc-coupled logarithmic detector with operation from dc to 120 MHz and up to 50 dB of dynamic range from one device. Its successive-detection architecture, summed full-wave detector output, 1 mA-per-decade video scaling, and laser calibration provide a compact alternative to a multi-stage discrete detector implementation. Select two AD640BD devices when the design needs as much as 95 dB of range, accepting the specified reduction in cascade bandwidth and the additional calibration-matching burden. Do not substitute a generic logarithmic amplifier solely on bandwidth or package similarity. A valid alternative must also match the 20-CDIP pinout, supply requirements, detector transfer characteristic, calibration behavior, and temperature stability. For lower-cost systems that only need one narrow frequency band, a simpler discrete detector may be adequate, but it will not reproduce the AD640BD's integrated broadband performance.

یادداشت‌های طراحی

Low-level calibration is the main measurement pitfall for the AD640. The manufacturer datasheet indicates that output displacement can differ among input waveforms between approximately -10 dBV and -40 dBV. Use calibration appropriate to the expected signal shape, verify offset at the lowest required input level, and avoid interpreting small residual deviations as a change in the true logarithmic slope.

Route the detector input and video output as sensitive high-frequency paths. Keep the input return connection short, provide a continuous ground plane, and separate the video output from the input node to reduce coupling. Because each internal stage has a 350 MHz -3 dB bandwidth, even though the complete device is specified to 120 MHz, high-value board effects should be checked with the final component and trace layout.

The summed video output is a current signal with a nominal scale of 1 mA per decade. Convert it to voltage with a suitable transimpedance network and then low-pass filter the result. Choose the filter cutoff from the required measurement bandwidth, not from the AD640's 120 MHz input bandwidth, and confirm that the amplifier and converter operate within their own input and output ranges.

اطلاعات انطباق

RoHS
Compliant
REACH
Unknown
AEC-Q100
Not Applicable
بدون سرب
Unknown
بدون هالوژن
Unknown
مواد معدنی درگیری
Unknown

The product listing identifies RoHS as supported. No verified REACH, halogen-free, conflict-minerals, or AEC-Q100 information was identified for the AD640BD.

تاریخ تأیید داده‌ها: 2026-11-18 — داده‌ها توسط تیم مهندسی قطعات XAIPART تأیید و گردآوری شده است

جستجوهای مرتبط

ad640 datasheet AD640BD datasheet AD640BD pinout AD640BD 20-CDIP package AD640BD 120 MHz logarithmic amplifier AD640BD 50 dB dynamic range AD640BD output current per decade Analog Devices AD640BD AD640BD RF power detection AD640BD cascade dynamic range AD640BD equivalent AD640BD drop-in replacement AD640BD price AD640BD stock AD640BD lead time

قطعات و اصطلاحات مرتبط

Analog Devices AD640BD AD640 logarithmic amplifier demodulating amplifier special-purpose amplifier successive detection full-wave detector logarithmic video output dynamic range dc coupling 120 MHz bandwidth 350 MHz stage bandwidth 1 mA per decade 20-CDIP ceramic dual in-line package through-hole mounting broadband RF detection automatic gain control spectrum analysis IF level monitoring laser calibration RoHS
استعلام قیمت سریع RFQ
جزئیات کامل را پر کنید — تیم فروش ما ظرف 24 ساعت پاسخ خواهد داد
شماره قطعه سازنده بسته‌بندی QTY قیمت هدف قیمت کل
✓
استعلام قیمت ارسال شد!

ظرف ۲۴ ساعت به ایمیل شما پاسخ خواهیم داد

1
درخواست قیمت ارسال شد
2
استعلام دریافت شد
3
سفارش ثبت شد
4
پرداخت
5
ارسال شد
6
تحویل داده شد
مشاهده جزئیات RFQ