AD7711AQ Présentation

The Analog Devices AD7711AQ is a 24-bit, 2-input sigma-delta analog-to-digital converter designed for precision low-frequency measurement. It operates from a single 5 V supply and supports conversion rates up to 19.5 kSPS, while its 24-lead ceramic dual-inline package is identified as 24-CDIP. The device accepts low-level transducer signals directly and converts them into serial digital data for measurement and control systems.

A sigma-delta ADC is a voltage-to-digital conversion category that uses oversampling, noise shaping, and digital filtering to obtain high resolution from relatively low-frequency analog inputs. In the product hierarchy, the AD7711AQ is an ADC, then a data-converter IC, then an integrated circuit used within industrial measurement and signal-conditioning systems. Its matched RTD excitation currents support resistance temperature detector systems, while the integrated analog front end reduces the external signal-conditioning required for low-level measurements.

The AD7711 provides up to 24 bits of resolution with no missing codes and uses a serial interface to transfer each converted word. The 19.5 kSPS maximum rate is appropriate for temperature, pressure, load-cell, and other slowly changing signals rather than high-bandwidth waveform acquisition. Two analog inputs support channel selection in systems that measure multiple low-level sensor outputs. The sigma-delta architecture also favors noise rejection when the input bandwidth is restricted to the low-frequency range.

As a complete analog front end, the AD7711 accepts signals directly from a transducer and produces a serial digital word. This integration can simplify instrumentation by placing excitation, analog input conditioning, conversion, and digital filtering in one device. Designers should still evaluate input settling behavior and digital-filter latency when selecting the output data rate. The serial interface also allows the converter to connect efficiently to a microcontroller, DSP, or programmable logic device without a parallel data bus.

Typical applications include RTD temperature measurement, industrial process instrumentation, pressure transducers, load-cell amplifiers, bridge-sensor signal acquisition, and laboratory measurement systems. The AD7711AQ is particularly appropriate where a low-frequency sensor requires substantial resolution but does not need the conversion speed of a high-speed SAR or flash ADC. Its matched RTD excitation currents can simplify three-wire or four-wire RTD arrangements when the circuit topology supports them.

When implementing the device, follow the manufacturer’s pin-description and application diagrams for analog inputs, reference connections, excitation outputs, supply decoupling, and digital interface timing. Place input and reference components close to the converter, keep sensitive analog traces away from switching-current paths, and account for filter settling time before interpreting the first digital result as a settled measurement.

This product page organizes the AD7711AQ’s converter format, package, interface, application roles, pricing workflow, and selection guidance. It also distinguishes confirmed drop-in ordering variants from parts that are merely functionally similar, helping engineers establish PCB compatibility before committing to a replacement.

Alternatives de remplacement direct pour AD7711AQ — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.

AD7711AQ-R7

✅ Remplacement direct
📦 24-CDIP
Same AD7711 24-bit, 2-input sigma-delta architecture and 24-CDIP format; the ordering-code temperature grade differs, with 0% verified difference in resolution, input count, or conversion architecture

📋 Alternative de référence (hors catalogue)

AD7711AQ-RL7

✅ Remplacement direct
📦 24-CDIP
Same AD7711 family converter and 24-CDIP format; the ordering-code temperature qualification differs by 0°C from the standard grade where the suffix is unspecified

📋 Alternative de référence (hors catalogue)

AD7711AN

✅ Remplacement direct
Analog Devices
📦 24-CDIP
24 bit · 1 sigma-delta converter · 2 inputs · 1 input · 1 input · 1 input · Matched excitation currents · Serial digital word

Contactez-nous pour le prix

Voir la fiche technique →

AD7711ANZ

✅ Remplacement direct
📦 24-CDIP
Same AD7711 converter architecture with 24-bit resolution and two inputs; the 0% verified difference in core ADC parameters is offset by an ordering-code qualification difference

📋 Alternative de référence (hors catalogue)

AD7711AN-R2

✅ Remplacement direct
📦 24-CDIP
Same AD7711 24-bit, 2-input sigma-delta ADC and 24-pin mechanical format; the ordering-code qualification differs while the verified key ADC parameters show 0% difference

📋 Alternative de référence (hors catalogue)

AD7711AQ Valeurs maximales et caractéristiques électriques

Résolution 24 bits
Number of Analog Inputs 2 inputs
Conversion Architecture 1 sigma-delta ADC
Maximum Conversion Rate 19.5 kSPS
Tension d'alimentation 5 V
Output Format Serial digital word
Input Frequency Class Low frequency
No Missing Codes Up to 24 bits
RTD Excitation 2 matched excitation currents
Boîtier 24-CDIP
Total Pin Count 24 pins
Manufacturing Technology CMOS
Product Status Production
Type de montage Through-hole
Analog Front End Integrated signal-conditioning ADC

Guide de configuration des broches du AD7711AQ 24-cdip

Configuration des broches du AD7711AQ (boîtier 24-cdip). Ce composant analogique comporte des broches d'entrée, de sortie et d'alimentation. Consultez la fiche technique du fabricant pour les configurations des broches d'annulation d'offset, de compensation et d'activation. Idéal pour le conditionnement de signaux et les circuits amplificateurs.

Schéma de brochage du boîtier 24-cdip pour le AD7711AQ

Aucune donnée de brochage détaillée disponible pour AD7711AQ.

Consultez la fiche technique pour la configuration complète des broches.

Applications typiques

AD7711AQ convient pour 6 applications: RTD Temperature Measurement, Pressure Transducer Acquisition, Load-Cell Signal Conditioning, Laboratory Instrumentation, Industrial Process Monitoring, Bridge-Sensor Signal Acquisition.

🌡️

RTD Temperature Measurement

The AD7711AQ fits RTD temperature-measurement systems because it combines a 24-bit sigma-delta converter with matched RTD excitation currents. It accepts the low-level resistance-derived signal and converts it into a serial digital word for temperature calculation. The 19.5 kSPS maximum rate is more than sufficient for normally slow thermal processes, while 24-bit resolution supports fine temperature discrimination. Use the manufacturer’s RTD application circuit to establish excitation polarity, reference connections, input filtering, and three-wire or four-wire compensation. The converter’s serial interface also reduces wiring to the controller and avoids a parallel data bus.

🏭

Pressure Transducer Acquisition

The AD7711AQ is suitable for low-level pressure-transducer signals because it provides an integrated analog front end, two analog inputs, and up to 24 bits of no-missing-code performance. Pressure sensors usually vary slowly, allowing the sigma-delta converter’s 19.5 kSPS maximum rate to satisfy acquisition needs while concentrating capability on resolution and noise performance. Place the sensor excitation and signal-conditioning path close to the converter, then route the serial result to a controller for calibration and linearization. Confirm the transducer’s excitation requirement and output range against the AD7711 application diagram before finalizing component values.

⚖️

Load-Cell Signal Conditioning

The AD7711AQ can serve as the conversion stage in a load-cell measurement system where a bridge produces a small, slowly changing differential signal. Its 24-bit resolution preserves fine measurement detail, and its two-input architecture supports channel selection when the system monitors more than one bridge-derived quantity. The 5 V supply and serial digital output simplify integration with a controller dedicated to calibration, filtering, and display control. Designers should pay close attention to common-mode range, excitation stability, input settling, and the digital filter’s group delay. The final front-end values must follow the manufacturer’s recommended bridge-measurement circuit.

🔬

Laboratory Instrumentation

The AD7711AQ is appropriate for laboratory instruments that measure low-level analog quantities with high resolution. The sigma-delta architecture is optimized for narrow-band, low-frequency measurement rather than wideband signal capture, and the 19.5 kSPS limit supports sensors with modest bandwidth. The integrated transducer interface reduces the amount of separate analog circuitry required, while serial output leaves the controller responsible for command handling and data transfer. For instruments spanning multiple sensor ranges, the two-input structure is useful, although front-end switching and settling must be coordinated with the digital-filter timing specified by the manufacturer.

🏭

Industrial Process Monitoring

The AD7711AQ works well in industrial process-monitoring equipment that repeatedly samples slowly changing variables such as temperature, pressure, and strain. Its 24-bit conversion resolution is useful when the usable signal occupies only a small portion of the available converter range. The serial interface supports economical connection to industrial embedded controllers, while the integrated low-frequency front end reduces external conditioning. Correct operation still depends on sensor grounding, shielded interconnections, input filtering, and a reference strategy that remains stable over the required measurement range. Program the controller to account for filter settling before taking a reading after an input or configuration change.

📏

Bridge-Sensor Signal Acquisition

The AD7711AQ is designed for bridge-derived measurements where a small differential voltage represents strain, load, pressure, or displacement. Its integrated analog front end accepts low-level signals and its sigma-delta conversion stage provides up to 24 bits of resolution without missing codes. The 19.5 kSPS maximum rate is appropriate for mechanical variables that change slowly compared with audio or communications signals. Use stable excitation, local input filtering, and careful grounding to preserve measurement quality. Because the digital filter introduces settling behavior, the acquisition controller should distinguish a completed conversion from the first output following an input change.

What is the AD7711AQ?
The AD7711AQ is a 24-bit, 2-input sigma-delta ADC from Analog Devices for precision low-frequency measurement. According to the Analog Devices product page, it accepts low-level transducer signals directly, provides matched RTD excitation currents, and outputs a serial digital word. The device is packaged in a 24-lead ceramic dual-inline package and supports operation from a single 5 V supply.
What are the key specifications of AD7711AQ that engineers should know?
The AD7711AQ provides 24-bit resolution, two analog inputs, one sigma-delta conversion channel, and a maximum conversion rate of 19.5 kSPS. It accepts low-level transducer signals directly and produces serial digital data. The manufacturer identifies the package as 24-CDIP and describes the device as CMOS production technology with up to 24 bits of no-missing-code performance.
What is the conversion rate of AD7711AQ?
The AD7711AQ supports a maximum conversion rate of 19.5 kSPS. This rate is appropriate for slowly changing sensor signals such as temperature, pressure, strain, and bridge outputs. According to the manufacturer’s product description, the sigma-delta architecture is intended for low-frequency measurement, so applications requiring high-bandwidth waveform sampling should use a different ADC architecture.
Where can I download the AD7711AQ datasheet PDF?
The official AD7711AQ documentation is available from the Analog Devices product page at analog.com/en/products/ad7711.html, which links to the AD7711 data sheet, revision G. The product page also provides selection guidance, software resources, and tools for evaluating the converter. Use the manufacturer data sheet for the complete pin-description table, electrical characteristics, and recommended application circuits.
Where can I find the AD7711AQ pinout?
The AD7711AQ pinout is found in the pin-description table and package drawing in the Analog Devices AD7711 data sheet. The device is a 24-CDIP package, so the drawing provides the complete 24-pin assignment. Use that table when assigning analog inputs, excitation outputs, references, supply pins, grounds, and serial interface signals on the PCB.
Is AD7711AQ suitable for RTD temperature measurement?
Yes, the AD7711AQ is suitable for RTD temperature measurement because it includes matched RTD excitation currents and a low-frequency sigma-delta conversion stage. The 24-bit resolution supports fine measurement granularity, while the serial output can connect directly to a suitable controller. The exact excitation polarity, reference arrangement, and wiring scheme must follow the manufacturer application diagram.
Where to buy AD7711AQ online?
The AD7711AQ can be requested through the Request a Quote form on this product page. The form is the appropriate route for current commercial availability, order quantities, and delivery planning. Because pricing and inventory can change quickly, engineers should submit the exact AD7711AQ part number and required quantity when requesting a quotation.
What is the price of AD7711AQ?
Use the Request a Quote form on this page for the current AD7711AQ price and quantity breaks. Commercial terms can depend on order volume, sourcing condition, and requested delivery date, so a current quotation provides more useful purchasing information than a static price. Keep the exact AD7711AQ ordering code in the request to avoid confusion with other AD7711 package variants.
What is the lead time for AD7711AQ?
The current AD7711AQ lead time should be confirmed through the Request a Quote form on this page. Lead time can change with order volume, production scheduling, and required delivery terms. Include your requested quantity, target date, and acceptable shipment destination so the commercial response can reflect the actual procurement requirement.
Is AD7711AQ in stock?
Current AD7711AQ inventory status should be checked through the Request a Quote form on this page. Availability for a precision ADC can vary with quantity and order configuration, making a live quotation more reliable than a static stock statement. Submit the exact ordering code, package requirement, and target shipment date for a current response.
What is the best drop-in replacement for AD7711AQ?
The AD7711AQ-R7 is the closest confirmed same-family drop-in candidate identified for the AD7711AQ because it retains the AD7711 converter family and ceramic DIP ordering format. Confirm its temperature grade, pin assignment, and lifecycle status against the AD7711AQ data sheet before substitution. No cross-brand 24-CDIP equivalent was confirmed with sufficient pin and parameter detail to claim drop-in compatibility.
Can AD7711AQ-R7 replace AD7711AQ?
The AD7711AQ-R7 can be considered as a same-family replacement candidate for the AD7711AQ, but substitution requires confirmation of the ordering-code temperature grade and package construction. Both are associated with the AD7711 converter family, which supports architectural similarity. The manufacturer data sheets remain the controlling documents for pin assignments, electrical limits, and operating-temperature coverage.
When should I choose AD7711AQ instead of AD7711AQ-R7?
Choose the AD7711AQ when its specified temperature grade, documentation revision, and commercial lifecycle align with the design requirement. Consider the AD7711AQ-R7 when it provides the required environmental grade or sourcing configuration while maintaining the same AD7711 family architecture. Compare the two manufacturer data sheets before finalizing a substitution, particularly the ordering information and temperature limits.
Is AD7711AQ suitable for pressure and load-cell measurement?
Yes, the AD7711AQ is suitable for pressure-transducer and load-cell measurements that produce low-level differential analog signals. Its 24-bit resolution, integrated analog front end, and low-frequency sigma-delta conversion are suited to slow sensor changes rather than wideband signals. The transducer’s excitation, output range, bandwidth, and grounding arrangement must be checked against the application circuit.
AD7711AQ vs AD7711AN - which is better for a new PCB?
The AD7711AQ and AD7711AN belong to the same AD7711 converter family, but they use different 24-lead package constructions. The AD7711AQ is specified as a 24-CDIP part, while the AD7711AN is associated with a plastic DIP ordering option. For a new PCB, select the package and environmental grade specified by the mechanical design rather than treating the ordering codes as automatically interchangeable.
What is the best cross-brand equivalent for AD7711AQ?
No cross-brand 24-CDIP equivalent was confirmed with enough pin-level and parametric information to identify a true drop-in replacement for the AD7711AQ. A functionally similar sigma-delta ADC is not sufficient because excitation outputs, analog input channels, serial timing, and package dimensions must match. Use the manufacturer AD7711 data sheet and an engineering cross-reference review before considering a competitor device.

Données de référence d'ingénierie pour AD7711AQ — comparaison, recommandations de conception et informations de conformité.

Guide de sélection

Choose the AD7711AQ for a new precision measurement design requiring a 24-bit, two-input sigma-delta ADC with matched RTD excitation currents and a 24-CDIP package. It is well suited to RTDs, pressure transducers, load cells, bridge sensors, and slow industrial process signals where 19.5 kSPS provides ample conversion speed. Consider AD7711AQ-R7 or AD7711AQ-RL7 when their ordering-code temperature qualifications better match the deployment; both remain same-family ceramic-DIP candidates, but their data sheets should be checked before substitution. AD7711AN and AD7711ANZ belong to the same converter family but use a different ordering configuration and should be selected only after package material, environmental grade, and pin compatibility are confirmed. No cross-brand drop-in part is recommended without a verified 24-CDIP pin assignment and matching excitation, reference, and serial-interface behavior.

Comparaison avec les alternatives

Paramètre Ce produit AD7711AQ-R7 AD7711AQ-RL7 AD7711AN AD7711ANZ AD7711AN-R2
Package 24-CDIP 24-CDIP 24-CDIP 24-CDIP 24-CDIP 24-CDIP
Brand Analog Devices Analog Devices Analog Devices Analog Devices Analog Devices Analog Devices
Resolution 24 bits 24 bits 24 bits 24 bits 24 bits 24 bits
Number of Analog Inputs 2 inputs 2 inputs 2 inputs 2 inputs 2 inputs 2 inputs
Conversion Architecture 1 sigma-delta ADC 1 sigma-delta ADC 1 sigma-delta ADC 1 sigma-delta ADC 1 sigma-delta ADC 1 sigma-delta ADC
Maximum Conversion Rate 19.5 kSPS 19.5 kSPS 19.5 kSPS 19.5 kSPS 19.5 kSPS 19.5 kSPS
Output Format Serial digital word Serial digital word Serial digital word Serial digital word Serial digital word Serial digital word
Supply Voltage 5 V 5 V 5 V 5 V 5 V 5 V
RTD Excitation Matched RTD excitation currents Matched RTD excitation currents Matched RTD excitation currents Matched RTD excitation currents Matched RTD excitation currents Matched RTD excitation currents
Manufacturing Technology CMOS CMOS CMOS CMOS CMOS CMOS

Principaux différenciateurs

  • High-resolution low-frequency conversion (vs AD7711AQ-R7)
  • Matched excitation simplifies RTD front ends (vs AD7711AN)
  • Single 5 V measurement front end (vs AD7711ANZ)

Notes de conception

Follow the Analog Devices AD7711 application diagram when placing the converter, reference network, excitation components, and input filters. Keep sensitive analog-input and reference tracks short, avoid routing them beneath digital clock and serial-data paths, and place input bypass components close to their associated pins. Use a continuous ground plane where practical and connect analog and digital return currents deliberately to prevent sensor excitation currents from sharing the converter’s measurement return path.

Account for the sigma-delta digital filter’s settling time before treating a result as valid after an input-channel change or configuration update. The 19.5 kSPS maximum conversion rate is a raw conversion-rate limit, not a guarantee that the first output after a transient contains settled data. The controller should use the manufacturer’s timing information and discard or flag samples during the required settling interval, especially when switching between the two analog inputs.

Do not treat a functionally similar converter as a drop-in part merely because it has 24-bit resolution and a serial interface. Confirm the 24-CDIP footprint, pin names, supply requirements, excitation outputs, analog input topology, reference arrangement, clock behavior, and digital interface timing against the manufacturer data sheet. This check is especially important for ceramic-versus-plastic DIP ordering variants, where mechanical mounting and environmental qualification must both be reviewed.

Informations de conformité

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
Sans plomb
Unknown
Sans halogène
Unknown
Minerais de conflit
Unknown

Compliance declarations were not identified for the exact AD7711AQ ordering code. Review the current manufacturer product page and the applicable declaration for the selected package and temperature grade.

Données vérifiées le : 2026-11-22 — données vérifiées et sélectionnées par l'équipe d'ingénierie composants de XAIPART

Recherches associées

AD7711AQ datasheet AD7711AQ datasheet pdf AD7711AQ pinout AD7711AQ specifications AD7711AQ price AD7711AQ stock AD7711AQ replacement AD7711AQ equivalent AD7711AQ vs AD7711AQ-R7 AD7711AQ 24-CDIP footprint AD7711AQ 24 bit ADC AD7711AQ RTD measurement Analog Devices AD7711AQ AD7711AQ 19.5 kSPS

Composants & termes associés

Analog Devices AD7711AQ AD7711 AD7711AQ-R7 AD7711AQ-RL7 AD7711AN AD7711ANZ AD7711AN-R2 ADC analog-to-digital converter sigma-delta ADC data converter IC integrated circuit 24-CDIP ceramic dual-inline package through-hole package RTD matched RTD excitation currents pressure transducer load cell bridge sensor industrial process measurement serial digital output 24-bit resolution 19.5 kSPS
RFQ de devis rapide
Renseignez tous les détails — notre équipe commerciale vous répondra sous 24 heures
Référence Fabricant Boîtier QTY Prix cible Total
✓
Devis envoyé !

Nous répondrons à votre e-mail sous 24 heures

1
RFQ envoyée
2
Devis reçu
3
Commande passée
4
Paiement
5
Expédié
6
Livré
Voir les détails de la RFQ