AD7711AQ - 24-Bit 2-Input Sigma-Delta ADC | Analog Devices
料号: AD7711AQ ✓ 量产中AD7711AQ 概述
A sigma-delta ADC is a voltage-to-digital conversion category that uses oversampling, noise shaping, and digital filtering to obtain high resolution from relatively low-frequency analog inputs. In the product hierarchy, the AD7711AQ is an ADC, then a data-converter IC, then an integrated circuit used within industrial measurement and signal-conditioning systems. Its matched RTD excitation currents support resistance temperature detector systems, while the integrated analog front end reduces the external signal-conditioning required for low-level measurements.
The AD7711 provides up to 24 bits of resolution with no missing codes and uses a serial interface to transfer each converted word. The 19.5 kSPS maximum rate is appropriate for temperature, pressure, load-cell, and other slowly changing signals rather than high-bandwidth waveform acquisition. Two analog inputs support channel selection in systems that measure multiple low-level sensor outputs. The sigma-delta architecture also favors noise rejection when the input bandwidth is restricted to the low-frequency range.
As a complete analog front end, the AD7711 accepts signals directly from a transducer and produces a serial digital word. This integration can simplify instrumentation by placing excitation, analog input conditioning, conversion, and digital filtering in one device. Designers should still evaluate input settling behavior and digital-filter latency when selecting the output data rate. The serial interface also allows the converter to connect efficiently to a microcontroller, DSP, or programmable logic device without a parallel data bus.
Typical applications include RTD temperature measurement, industrial process instrumentation, pressure transducers, load-cell amplifiers, bridge-sensor signal acquisition, and laboratory measurement systems. The AD7711AQ is particularly appropriate where a low-frequency sensor requires substantial resolution but does not need the conversion speed of a high-speed SAR or flash ADC. Its matched RTD excitation currents can simplify three-wire or four-wire RTD arrangements when the circuit topology supports them.
When implementing the device, follow the manufacturer’s pin-description and application diagrams for analog inputs, reference connections, excitation outputs, supply decoupling, and digital interface timing. Place input and reference components close to the converter, keep sensitive analog traces away from switching-current paths, and account for filter settling time before interpreting the first digital result as a settled measurement.
This product page organizes the AD7711AQ’s converter format, package, interface, application roles, pricing workflow, and selection guidance. It also distinguishes confirmed drop-in ordering variants from parts that are merely functionally similar, helping engineers establish PCB compatibility before committing to a replacement.
直接替换替代料: AD7711AQ ——相同封装,引脚兼容。需要 PCB 改动的不同封装料号已排除。
AD7711AQ-R7
✅ 直接替换📋 参考替代料(不在目录中)
AD7711AQ-RL7
✅ 直接替换📋 参考替代料(不在目录中)
AD7711AN
✅ 直接替换联系询价
查看数据手册 →AD7711ANZ
✅ 直接替换📋 参考替代料(不在目录中)
AD7711AN-R2
✅ 直接替换📋 参考替代料(不在目录中)
AD7711AQ 最大额定值与电气特性
| 分辨率 | 24 bits |
| Number of Analog Inputs | 2 inputs |
| Conversion Architecture | 1 sigma-delta ADC |
| Maximum Conversion Rate | 19.5 kSPS |
| 电源电压 | 5 V |
| Output Format | Serial digital word |
| Input Frequency Class | Low frequency |
| No Missing Codes | Up to 24 bits |
| RTD Excitation | 2 matched excitation currents |
| 封装 | 24-CDIP |
| Total Pin Count | 24 pins |
| Manufacturing Technology | CMOS |
| Product Status | Production |
| 安装类型 | Through-hole |
| Analog Front End | Integrated signal-conditioning ADC |
AD7711AQ 24-cdip 引脚配置指南
AD7711AQ(24-cdip 封装)的引脚配置。 该模拟元件具有输入、输出和电源引脚。请参阅制造商数据手册以了解失调调零、补偿和使能引脚配置。适用于信号调理和放大器电路。
暂无详细引脚数据: AD7711AQ.
请参阅 数据手册 以查看完整引脚配置。
典型应用
AD7711AQ 适用于 6 应用s: RTD Temperature Measurement, Pressure Transducer Acquisition, Load-Cell Signal Conditioning, Laboratory Instrumentation, Industrial Process Monitoring, Bridge-Sensor Signal Acquisition.
RTD Temperature Measurement
The AD7711AQ fits RTD temperature-measurement systems because it combines a 24-bit sigma-delta converter with matched RTD excitation currents. It accepts the low-level resistance-derived signal and converts it into a serial digital word for temperature calculation. The 19.5 kSPS maximum rate is more than sufficient for normally slow thermal processes, while 24-bit resolution supports fine temperature discrimination. Use the manufacturer’s RTD application circuit to establish excitation polarity, reference connections, input filtering, and three-wire or four-wire compensation. The converter’s serial interface also reduces wiring to the controller and avoids a parallel data bus.
推荐
Pressure Transducer Acquisition
The AD7711AQ is suitable for low-level pressure-transducer signals because it provides an integrated analog front end, two analog inputs, and up to 24 bits of no-missing-code performance. Pressure sensors usually vary slowly, allowing the sigma-delta converter’s 19.5 kSPS maximum rate to satisfy acquisition needs while concentrating capability on resolution and noise performance. Place the sensor excitation and signal-conditioning path close to the converter, then route the serial result to a controller for calibration and linearization. Confirm the transducer’s excitation requirement and output range against the AD7711 application diagram before finalizing component values.
推荐
Load-Cell Signal Conditioning
The AD7711AQ can serve as the conversion stage in a load-cell measurement system where a bridge produces a small, slowly changing differential signal. Its 24-bit resolution preserves fine measurement detail, and its two-input architecture supports channel selection when the system monitors more than one bridge-derived quantity. The 5 V supply and serial digital output simplify integration with a controller dedicated to calibration, filtering, and display control. Designers should pay close attention to common-mode range, excitation stability, input settling, and the digital filter’s group delay. The final front-end values must follow the manufacturer’s recommended bridge-measurement circuit.
推荐
Laboratory Instrumentation
The AD7711AQ is appropriate for laboratory instruments that measure low-level analog quantities with high resolution. The sigma-delta architecture is optimized for narrow-band, low-frequency measurement rather than wideband signal capture, and the 19.5 kSPS limit supports sensors with modest bandwidth. The integrated transducer interface reduces the amount of separate analog circuitry required, while serial output leaves the controller responsible for command handling and data transfer. For instruments spanning multiple sensor ranges, the two-input structure is useful, although front-end switching and settling must be coordinated with the digital-filter timing specified by the manufacturer.
推荐
Industrial Process Monitoring
The AD7711AQ works well in industrial process-monitoring equipment that repeatedly samples slowly changing variables such as temperature, pressure, and strain. Its 24-bit conversion resolution is useful when the usable signal occupies only a small portion of the available converter range. The serial interface supports economical connection to industrial embedded controllers, while the integrated low-frequency front end reduces external conditioning. Correct operation still depends on sensor grounding, shielded interconnections, input filtering, and a reference strategy that remains stable over the required measurement range. Program the controller to account for filter settling before taking a reading after an input or configuration change.
推荐
Bridge-Sensor Signal Acquisition
The AD7711AQ is designed for bridge-derived measurements where a small differential voltage represents strain, load, pressure, or displacement. Its integrated analog front end accepts low-level signals and its sigma-delta conversion stage provides up to 24 bits of resolution without missing codes. The 19.5 kSPS maximum rate is appropriate for mechanical variables that change slowly compared with audio or communications signals. Use stable excitation, local input filtering, and careful grounding to preserve measurement quality. Because the digital filter introduces settling behavior, the acquisition controller should distinguish a completed conversion from the first output following an input change.
推荐
推荐产品汇总
工程参考数据: AD7711AQ ——对比、设计指导和合规信息。
选型指南
与替代料对比
| 参数 | 本产品 | AD7711AQ-R7 | AD7711AQ-RL7 | AD7711AN | AD7711ANZ | AD7711AN-R2 |
|---|---|---|---|---|---|---|
| Package | 24-CDIP | 24-CDIP | 24-CDIP | 24-CDIP | 24-CDIP | 24-CDIP |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Resolution | 24 bits | 24 bits | 24 bits | 24 bits | 24 bits | 24 bits |
| Number of Analog Inputs | 2 inputs | 2 inputs | 2 inputs | 2 inputs | 2 inputs | 2 inputs |
| Conversion Architecture | 1 sigma-delta ADC | 1 sigma-delta ADC | 1 sigma-delta ADC | 1 sigma-delta ADC | 1 sigma-delta ADC | 1 sigma-delta ADC |
| Maximum Conversion Rate | 19.5 kSPS | 19.5 kSPS | 19.5 kSPS | 19.5 kSPS | 19.5 kSPS | 19.5 kSPS |
| Output Format | Serial digital word | Serial digital word | Serial digital word | Serial digital word | Serial digital word | Serial digital word |
| Supply Voltage | 5 V | 5 V | 5 V | 5 V | 5 V | 5 V |
| RTD Excitation | Matched RTD excitation currents | Matched RTD excitation currents | Matched RTD excitation currents | Matched RTD excitation currents | Matched RTD excitation currents | Matched RTD excitation currents |
| Manufacturing Technology | CMOS | CMOS | CMOS | CMOS | CMOS | CMOS |
关键差异点
- High-resolution low-frequency conversion (对比 AD7711AQ-R7)
- Matched excitation simplifies RTD front ends (对比 AD7711AN)
- Single 5 V measurement front end (对比 AD7711ANZ)
设计说明
Follow the Analog Devices AD7711 application diagram when placing the converter, reference network, excitation components, and input filters. Keep sensitive analog-input and reference tracks short, avoid routing them beneath digital clock and serial-data paths, and place input bypass components close to their associated pins. Use a continuous ground plane where practical and connect analog and digital return currents deliberately to prevent sensor excitation currents from sharing the converter’s measurement return path.
Account for the sigma-delta digital filter’s settling time before treating a result as valid after an input-channel change or configuration update. The 19.5 kSPS maximum conversion rate is a raw conversion-rate limit, not a guarantee that the first output after a transient contains settled data. The controller should use the manufacturer’s timing information and discard or flag samples during the required settling interval, especially when switching between the two analog inputs.
Do not treat a functionally similar converter as a drop-in part merely because it has 24-bit resolution and a serial interface. Confirm the 24-CDIP footprint, pin names, supply requirements, excitation outputs, analog input topology, reference arrangement, clock behavior, and digital interface timing against the manufacturer data sheet. This check is especially important for ceramic-versus-plastic DIP ordering variants, where mechanical mounting and environmental qualification must both be reviewed.
合规信息
Compliance declarations were not identified for the exact AD7711AQ ordering code. Review the current manufacturer product page and the applicable declaration for the selected package and temperature grade.