AD7711ASQ - 24-Bit Sigma-Delta ADC | Analog Devices
Référence : AD7711ASQ ✓ ActifAD7711ASQ Présentation
An ADC is an analog-to-digital converter, a semiconductor within the data-converter and signal-processing hierarchy. The AD7711 is specifically a sigma-delta ADC: its internal architecture converts the analog input into a bit-stream and digitally filters it to produce a high-resolution result. This approach is particularly effective for slow sensor signals where low noise and high effective resolution matter more than high sampling bandwidth.
Key features include conversion resolution of up to 24 bits without missing codes, two analog input channels, and a differential reference architecture. One channel normally serves as the main measurement input while the auxiliary channel can be selected to monitor a second voltage periodically. The serial output supports integration with external digital control and data-processing circuitry.
The device is intended to operate as a complete analog front end rather than a conventional high-speed sampling ADC. Its sigma-delta conversion technique, low-level input capability, and differential reference arrangement suit instrumentation in which the source impedance, reference quality, settling time, and digital averaging strategy strongly influence final measurement accuracy.
Typical measurement paths include pressure and force transducers, temperature sensors, bridge-based sensors, industrial process instrumentation, laboratory instruments, and low-level battery-powered monitoring systems. The auxiliary input can support periodic diagnostic or reference measurements when the transducer arrangement permits it.
When designing around the AD7711ASQ, use the manufacturer pin-description table to assign analog, reference, digital, and supply connections. Input and reference networks must be designed around the selected conversion rate and digital filter settings, because settling time and source impedance can affect the time needed to obtain a valid result.
This page combines the manufacturer’s device description, package information, family comparisons, sourcing guidance, and practical design considerations to support component selection, PCB planning, and low-frequency measurement-system development.
Alternatives de remplacement direct pour AD7711ASQ — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.
AD7711SQ
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
AD7711ASQ Valeurs maximales et caractéristiques électriques
| Converter Type | Sigma-delta ADC |
| Résolution | Up to 24 bits without missing codes |
| Analog Input Count | 2 inputs |
| Differential Analog Input | 1 input |
| Single-Ended Analog Input | 1 input |
| Reference Input | Differential reference input |
| Output Format | Serial digital word |
| Primary Measurement Category | Low-frequency measurement |
| Boîtier | 24-CDIP |
| Type de montage | Through-hole |
Guide de configuration des broches du AD7711ASQ 24-cdip
Configuration des broches du AD7711ASQ (boîtier 24-cdip). Ce composant analogique comporte des broches d'entrée, de sortie et d'alimentation. Consultez la fiche technique du fabricant pour les configurations des broches d'annulation d'offset, de compensation et d'activation. Idéal pour le conditionnement de signaux et les circuits amplificateurs.
Aucune donnée de brochage détaillée disponible pour AD7711ASQ.
Consultez la fiche technique pour la configuration complète des broches.
Applications typiques
AD7711ASQ convient pour 6 applications: Industrial Pressure Transducer Interface, Temperature and RTD Instrumentation, Precision Force and Load Measurement, Low-Level Process Monitoring, Laboratory and Test Equipment, Battery-Powered Sensor Node.
Industrial Pressure Transducer Interface
The AD7711ASQ fits low-level industrial pressure measurement because it accepts a transducer-derived voltage and converts it into a serial digital result with up to 24-bit resolution. Place the sensor excitation and conditioning network ahead of the differential input, and use the differential reference arrangement to reduce sensitivity to supply and common-mode variation. The sigma-delta architecture is suited to slow pressure signals that change over seconds or minutes rather than waveforms requiring high-rate sampling. Final accuracy depends on selecting a compatible excitation scheme, observing the manufacturer’s input and reference limits, and allowing enough settling time for the programmed digital filter behavior.
Recommandé
Temperature and RTD Instrumentation
The AD7711ASQ is appropriate for RTD, thermocouple, and resistance-based temperature measurement where the sensor produces a low-level analog signal and the required conversion speed is low. Its differential input can support a carefully balanced bridge or current-excitation network, while the auxiliary single-ended input provides a way to monitor a second voltage periodically when the circuit architecture permits it. The 24-bit conversion capability provides a useful starting point for resolving small temperature-induced voltage changes. Engineers should still budget for excitation drift, reference accuracy, lead resistance, digital-filter settling time, and electrical-noise coupling around the sensitive analog nodes.
Recommandé
Precision Force and Load Measurement
The AD7711ASQ can serve as the conversion element in a precision force, load-cell, or strain-gauge measurement system because it directly handles low-level differential sensor signals and supports high-resolution serial output. A typical design places the strain bridge close to the converter, limits switch resistance and thermal gradients, and drives the differential reference from a stable source. The sigma-delta method favors slow force changes where sensitivity and repeatability matter more than sampling speed. Use the manufacturer’s recommended application circuits to establish filtering and grounding, then validate the complete signal chain for excitation drift, common-mode range, filter settling, and calibration stability.
Recommandé
Low-Level Process Monitoring
The AD7711ASQ is well suited to industrial process monitoring when the measured variable appears as a small differential voltage and must be digitized for supervisory control or data logging. Its two analog inputs can support a primary measurement channel and periodic auxiliary monitoring when the process permits. Because the converter emphasizes resolution rather than high-rate sampling, it fits temperature, level, flow, and chemical-sensor loops with relatively slow dynamics. A robust implementation should isolate sensitive inputs from switching converters, maintain a low-noise reference, provide stable sensor excitation, and account for the conversion and digital-filter settling time before taking each result.
Recommandé
Laboratory and Test Equipment
The AD7711ASQ can form the measurement core of laboratory instrumentation that records small voltages with high resolution and reports results over a serial interface. Its differential input and reference arrangement are valuable when the source is balanced and the instrument must reject supply noise or common-mode variation. The converter is most appropriate for chopped, scanned, or slowly varying measurements rather than wideband oscilloscope acquisition. Designers should determine the required output rate, digital filtering, calibration coefficients, and interrupt or polling strategy, then ensure that analog input settling and reference settling are included in the acquisition timing.
Recommandé
Battery-Powered Sensor Node
The AD7711ASQ can support low-power sensor nodes that periodically measure slowly changing inputs and transmit the converted values through a serial interface. Its sigma-delta architecture is suited to low-bandwidth measurements, while the differential reference and input paths can help maintain signal integrity in compact multi-sensor systems. Power savings depend on the complete implementation because the converter’s supply current, operating mode, reference circuit, and required conversion interval determine the average demand. Use the datasheet’s mode and timing tables to select the acquisition profile, disable functions when permitted, and separate sensitive analog routing from digital and wireless subsystem switching activity.
Recommandé
Récapitulatif des produits recommandés
Données de référence d'ingénierie pour AD7711ASQ — comparaison, recommandations de conception et informations de conformité.
Guide de sélection
Comparaison avec les alternatives
| Paramètre | Ce produit | AD7711SQ |
|---|---|---|
| Package | 24-CDIP | 24-CDIP |
| Brand | Analog Devices | Analog Devices |
| Converter Type | Sigma-delta ADC | Sigma-delta ADC |
| Resolution | Up to 24 bits | Up to 24 bits |
| Analog Inputs | 2 inputs: one differential and one single-ended | 2 inputs: one differential and one single-ended |
| Reference Input | Differential | Differential |
| Output Format | Serial digital word | Serial digital word |
| Primary Application | Low-frequency measurement | Low-frequency measurement |
Principaux différenciateurs
- Complete low-frequency analog front end (vs AD7711SQ)
- Direct transducer-oriented integration (vs AD7711SQ)
- Dual-input measurement architecture (vs AD7711SQ)
Notes de conception
Route the differential analog input as a short, tightly matched pair on a quiet section of the PCB, and keep the analog reference network physically separate from digital switching nodes. Connect the return path to the device’s designated ground and analog-ground pins according to the manufacturer layout guidance. A 24-CDIP footprint also requires care at the board edge: leave sufficient clearance for insertion, removal, soldering, and inspection without placing tall components where they interfere with the socket or package.
Do not treat 24-bit resolution as guaranteed system accuracy. Effective performance also depends on the selected conversion rate, digital filter, reference voltage, input source impedance, analog noise, settling time, and calibration. Confirm that each result is read only after the required digital filter and conversion interval have elapsed. The auxiliary channel may also require different filtering and settling behavior, so validate both channels as part of the measurement sequence.
Keep the reference source quiet because reference noise appears directly in the conversion result. Avoid routing reference and sensitive input traces beneath digital clocks, high-current switching nodes, or display and relay return paths. Use the manufacturer’s recommended reference and input capacitance values, place those components close to the corresponding pins, and maintain a continuous ground reference beneath sensitive routes. Validate the completed board across temperature and supply variation because PCB leakage and contaminated surfaces can affect very low-level measurements.
Informations de conformité
Compliance attributes require confirmation from the current manufacturer product documentation or declaration for the exact ordering code.