AD8226BRZ-RL7 - Wide Supply Range In-Amp | Analog Devices
Référence : AD8226BRZ-RL7 ✓ Actif| Qté | Prix unitaire | Total |
|---|---|---|
| 1 | $8.55 | $8,55 |
| 10 | $7.86 | $78,60 |
| 100 | $6.52 | $652,00 |
| 500 | $5.48 | $2 740,00 |
| 1 000 | $4.98 | $4 980,00 |
| 3 000 | $4.75 | $14 250,00 |
AD8226BRZ-RL7 Présentation
An instrumentation amplifier (in-amp) is a precision differential amplifier with high input impedance and high common-mode rejection, used to amplify small signals in the presence of large common-mode voltages. It is a key building block in precision analog signal chains, often following a sensor bridge or transducer, and preceding an ADC. The AD8226 belongs to the family of instrumentation amplifiers, which are a subset of operational amplifiers optimized for differential measurement.
Key features of the AD8226 include a gain range of 1 to 1000 set by a single external resistor, rail-to-rail output swing, and a wide input voltage range that includes below ground. The device also offers excellent AC and DC performance, with a typical gain error of 0.1% (max) and gain drift of 10 ppm/°C (max). Quiescent current is only 350 µA (typical), making it suitable for low-power, battery-operated equipment. The AD8226 is specified over the extended industrial temperature range of -40°C to +125°C.
Technically, the AD8226 uses a three-op-amp topology with a precision laser-trimmed resistor network, ensuring high accuracy and stability. The input stage provides high common-mode rejection, while the output stage delivers rail-to-rail swing. The device is fully specified for both single and dual supply operation, and its input range extends below the negative rail, allowing it to handle signals that go slightly below ground.
Typical applications include industrial process control, bridge amplifiers, medical instrumentation, and data acquisition systems. The AD8226 is ideal for amplifying small differential signals from sensors such as strain gauges, thermocouples, and current shunt monitors. Its wide supply range and low power make it suitable for portable and battery-operated equipment.
When designing with the AD8226, ensure that the reference pin is properly driven to set the output common-mode voltage, and use a precision resistor for gain setting to maintain accuracy. Bypass the supply pins with 0.1 µF ceramic capacitors close to the device to ensure stability.
Alternatives de remplacement direct pour AD8226BRZ-RL7 — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.
Variantes de cette série
Modèles de la même série directement compatibles avec AD8226BRZ-RL7 (même facteur de forme et même empreinte) — différant par Gain Range, Input Offset Voltage, Quiescent Current, Operating Temperature Range, Amplifier Type.
Outil de comparaison rapide — sélectionnez des références alternatives pour une comparaison côte à côte :
AD8227BRZ
✅ Remplacement direct✓ En stock
$2.95 / unité
Voir la fiche technique →AD8223ARZ
✅ Remplacement direct ⚠️ Spécifications non vérifiées✓ En stock
$2.46 / unité
Voir la fiche technique →AD8221ARZ
✅ Remplacement direct ⚠️ Spécifications non vérifiées✓ En stock
$3.29 / unité
Voir la fiche technique →AD620ARZ
✅ Remplacement direct ⚠️ Spécifications non vérifiées✓ En stock
$7.2 / unité
Voir la fiche technique →INA826AID
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
AD8226BRZ-RL7 Valeurs maximales et caractéristiques électriques
| Product Category | Instrumentation Amplifier |
| Number of Channels | 1 Circuit |
| Gain Range | 1 to 1000 (set by 1 external resistor) |
| Single Supply Voltage | 4.5 V to 36 V |
| Dual Supply Voltage | ±2.25 V to ±18 V |
| Courant de repos | 350 µA typical |
| Gain Error | 0.1% max |
| Gain Drift | 10 ppm/°C max |
| Rail-to-Rail Output | Yes |
| Input Range Below Ground | Yes |
| Plage de température de fonctionnement | -40°C to +125°C |
| Boîtier / Format | 8-SOIC (BRZ suffix) |
| Type de montage | Surface Mount |
| Topologie | Three-op-amp instrumentation amplifier |
| Gain Setting Method | One external resistor |
| Reference Pin | Yes (sets output common-mode voltage) |
Configuration des broches de AD8226BRZ-RL7
| Broche 1 | RG — Gain-setting resistor terminal |
| Broche 2 | -IN — Inverting input |
| Broche 3 | +IN — Non-inverting input |
| Broche 4 | -VS — Negative supply |
| Broche 5 | REF — Reference pin (sets output common-mode voltage) |
| Broche 6 | OUT — Output |
| Broche 7 | +VS — Positive supply |
| Broche 8 | RG — Gain-setting resistor terminal |
Applications typiques
AD8226BRZ-RL7 convient pour 6 applications: Industrial Process Control, Bridge / Load Cell Amplifier, Medical ECG / Patient Monitoring, Data Acquisition Systems, Current Shunt Monitor, Portable / Battery-Powered Instrumentation.
Industrial Process Control
The AD8226BRZ-RL7 is ideal for industrial process control where 4-20 mA loop transmitters run from 24 V supplies. Its 4.5 V to 36 V single-supply range directly handles 24 V rails, while the 350 µA quiescent current keeps the loop budget low. The gain is set with one external resistor, so a single in-amp can serve many sensor types. The rail-to-rail output drives a precision ADC such as the AD7172-2BRUZ, enabling accurate bridge, thermocouple, and pressure sensor measurements in harsh noise environments.
Recommandé
Bridge / Load Cell Amplifier
Strain-gauge bridges generate small differential signals riding on a common-mode voltage near mid-supply. The AD8226BRZ-RL7’s wide input range and 0.1% max gain error preserve bridge accuracy, and gains from 1 to 1000 allow a single design to cover 10 kg to 1000 kg load cells. Use a precision metal-film resistor between RG pins to set the exact gain. After amplification, a 24-bit sigma-delta ADC like the AD7799BRUZ digitizes the signal with low noise.
Recommandé
Medical ECG / Patient Monitoring
Electrocardiogram (ECG) signals are low-level (0.5-5 mV) and contaminated by large 50/60 Hz common-mode voltages. The AD8226BRZ-RL7 can amplify these signals with high common-mode rejection while its low bias current preserves electrode integrity. Rail-to-rail output allows direct interface to single-supply ADC inputs. A driven-right-leg or reference pin connection can further suppress common-mode noise. The -40°C to +125°C temperature range supports body-worn and clinical monitors.
Recommandé
Data Acquisition Systems
Data acquisition systems need a flexible front end with high input impedance and programmable gain. The AD8226BRZ-RL7 delivers gains of 1 to 1000 using one resistor, so channel scaling can be updated without PCB changes. Its 350 µA quiescent current helps keep system power budgets low in multichannel boards. After the in-amp, a high-throughput ADC such as the AD7606BSTZ-4RL can capture synchronized samples. For lower-speed precision, the AD7172-2BRUZ provides 24-bit resolution.
Recommandé
Current Shunt Monitor
The AD8226BRZ-RL7 can amplify the small differential voltage across a shunt resistor in high-side current sensing applications. Its input voltage can go below ground, protecting against negative transients during inductive load switching. Set gain with one resistor; for example, 50 A through a 0.1 mΩ shunt produces 5 mV, requiring a gain of 100 to produce a 0.5 V ADC input. Pair with a precision ADC like the AD7124-4BRUZ-RL for industrial monitoring.
Recommandé
Portable / Battery-Powered Instrumentation
The AD8226BRZ-RL7 operates from a single supply as low as 4.5 V, making it suitable for two-cell Li-ion or four-cell alkaline systems. With only 350 µA typical quiescent current, it extends battery life in handheld field instruments. The rail-to-rail output maximizes the ADC input range. A zero-drift op amp such as the ADA4522-1ARZ can buffer the output when driving long cables or capacitive loads, while the in-amp remains the precision acquisition front end.
Recommandé
Récapitulatif des produits recommandés
Données de référence d'ingénierie pour AD8226BRZ-RL7 — comparaison, recommandations de conception et informations de conformité.
Guide de sélection
Comparaison avec les alternatives
| Paramètre | Ce produit | AD8227BRZ | AD8223ARZ | AD8221ARZ | AD620ARZ | INA826AID |
|---|---|---|---|---|---|---|
| Package | 8-SOIC | 8-SOIC | 8-SOIC | 8-SOIC | 8-SOIC | 8-SOIC |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Texas Instruments |
| Rail-to-Rail Output | Yes | Yes | Yes | Yes | Yes | Yes |
| Operating Temperature Range | -40°C to +125°C | -40°C to +125°C | -40°C to +125°C | -40°C to +125°C | -40°C to +125°C | -40°C to +125°C |
Principaux différenciateurs
- Gain range extends down to 1, unlike AD8227BRZ which has a minimum gain of 5 (vs AD8227BRZ)
- Lower quiescent current than AD620ARZ (vs AD620ARZ)
- Native Analog Devices portfolio support with low-cost, wide supply range (vs INA826AID)
Notes de conception
For AD8226, gain accuracy depends on the external resistor connected between pins 1 and 8. Use a 1% or better metal-film resistor and minimize parasitic capacitance to avoid frequency response peaking. Keep the gain resistor close to the pins and use a guard ring if the value is high (>100kΩ).
Place 0.1 µF low-ESR ceramic capacitors directly at V+ and V- pins to ground. For single-supply operation, add 10 µF bulk capacitor close to the device to handle load transients. The reference pin should be decoupled to ground with 0.1 µF to keep output common-mode stable.
AD8226 draws only 350 µA typical; however, output stage can source/sink several mA. In battery-powered designs, use a low-dropout regulator upstream and consider shutting down the in-amp with a series switch to save power in standby. Ensure input common-mode remains within specified input range to preserve linearity.
Informations de conformité
Compliance not explicitly listed in verified web data. Confirm on the Analog Devices product page for latest RoHS/REACH status.