ADM233LJNZ - 120kbps RS-232 Transceiver | Analog Devices
Référence : ADM233LJNZ ✓ ActifADM233LJNZ Présentation
A line transceiver is an interface circuit that translates logic-level signals into RS-232 voltage levels and converts received RS-232 signals back into digital logic levels. Within the interface hierarchy, it belongs to the RS-232 transceiver family of communication ICs, where it bridges modern controller logic and legacy point-to-point serial equipment. The ADM233L is particularly useful when a system cannot provide the traditional ±12 V RS-232 supply.
The integrated DC-DC conversion system produces the bipolar voltages required by RS-232 from a single 5 V rail, eliminating the need for external charge-pump components. The device supports 120 kbps signaling, provides two transmit channels and two receive channels, and uses small 1 µF external capacitors as stated by Analog Devices. Its dual-driver, dual-receiver arrangement makes it suitable for links requiring one bidirectional channel plus one additional direction, or for a design that can be configured differently around the two driver and receiver sections.
The ADM233L is intended for EIA-232-E and V.28 interfaces where 12 V is unavailable. Its single-supply architecture simplifies power distribution while retaining the voltage levels expected by RS-232 equipment. Because RS-232 is a single-ended, unbalanced interface, board layout should keep the driver outputs and receiver inputs away from sensitive analog and high-speed digital traces. The transmitter and receiver functions should also be routed so outgoing and incoming signals do not unnecessarily share long parallel paths.
Typical uses include industrial serial-control links, data-acquisition equipment, service interfaces, test systems, and embedded controllers communicating with RS-232 peripherals. The 120 kbps rate is appropriate for configuration commands, telemetry, firmware transfer, and general-purpose serial control where longer distances and noise immunity are more important than very high throughput. A null modem or crossover arrangement is still required when connecting two similarly configured data-terminal devices.
The principal design consideration is decoupling and signal integrity. Place the specified 1 µF capacitors close to their associated pins, provide a stable 5 V supply, and route each RS-232 signal as a direct point-to-point channel. Avoid long unprotected traces adjacent to switching nodes or high-current return paths. For industrial equipment, verify the complete board against the applicable EMC requirements and provide appropriate chassis grounding at the connector rather than relying on the logic ground alone.
This product overview combines the confirmed ADM233LJNZ electrical features, package details, interface standards, and practical RS-232 layout guidance with drop-in comparison information intended to accelerate component selection and PCB redesign planning.
Alternatives de remplacement direct pour ADM233LJNZ — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.
Variantes de cette série
Modèles de la même série directement compatibles avec ADM233LJNZ (même facteur de forme et même empreinte) — différant par Interface Standard, Maximum Data Rate.
ADM233LJN
✅ Remplacement directContactez-nous pour le prix
Voir la fiche technique →ADM233LAN
✅ Remplacement directContactez-nous pour le prix
Voir la fiche technique →ADM233LANZ
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
MAX203CPP+G36
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
MAX203ECPP+G36
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
ADM233LJNZ Spécifications
| Device Type | 2/2 RS-232 line transceiver |
| Number of Drivers | 2 |
| Number of Receivers | 2 |
| Maximum Data Rate | 120 kbps |
| Tension d'alimentation | 5 V |
| RS-232 Output Swing | Approximately ±9 V |
| External Capacitor Value | 1 µF |
| Interface Standard | EIA-232-E |
| Interface Standard | V.28 |
| Boîtier | 20-pin PDIP |
| Package Pin Count | 20 pins |
| Type de montage | Through-hole |
| Integrated DC-DC Converters | On-board |
| External Power-Supply Requirement | No external ±12 V supply |
Guide de configuration des broches du ADM233LJNZ 20 pins
Configuration des broches du ADM233LJNZ (boîtier 20 pins). La numérotation des broches, les fonctions et les schémas de connexion sont définis dans la fiche technique du fabricant. Consultez-la pour l'empreinte exacte et les directives de soudage.
Aucune donnée de brochage détaillée disponible pour ADM233LJNZ.
Consultez la fiche technique pour la configuration complète des broches.
Applications typiques
ADM233LJNZ convient pour 6 applications: Industrial Serial Control, Data Acquisition Equipment, Embedded Equipment Interface, Test and Measurement Systems, Service and Configuration Port, Telemetry and Remote Control.
Industrial Serial Control
The ADM233LJNZ is appropriate for industrial controllers that communicate with legacy RS-232 equipment through a 5 V supply. Its 120 kbps data rate supports configuration commands, status reporting, and moderate firmware transfers without requiring an external ±12 V rail. The two transmitters and two receivers provide flexible channel allocation for a bidirectional control link or separate point-to-point paths. On-board DC-DC conversion generates the approximately ±9 V driver swing internally. Designers should still route the RS-232 traces away from switching power nodes and verify the enclosure’s ESD and surge-protection requirements.
Recommandé
Data Acquisition Equipment
The ADM233LJNZ fits data-acquisition instruments that expose a compact RS-232 command or measurement interface. At up to 120 kbps, it can transfer sampled status data, configuration records, and diagnostic commands over a point-to-point cable. Its single 5 V operation is useful when the instrument already has a low-voltage control rail but lacks space for external bipolar generation circuitry. Two drivers and two receivers permit a bidirectional command path plus a separate reporting channel. Place the required 1 µF capacitors near the device and use protected connector-side routing where cables enter industrial or laboratory equipment.
Recommandé
Embedded Equipment Interface
Embedded systems can use the ADM233LJNZ to bridge low-voltage controller logic and an RS-232 peripheral without a separate negative supply. The integrated converters produce the bipolar voltage required for approximately ±9 V driver output, while the receiver channels return EIA-232-E-compatible signals to digital logic. The 120 kbps rate is suitable for configuration menus, boot-loader messages, and supervisory telemetry rather than continuous high-bandwidth transfers. Because RS-232 is unbalanced and single-ended, keep the interface away from high-current switching paths and provide a defined signal-ground strategy at the cable connector.
Recommandé
Test and Measurement Systems
The ADM233LJNZ can provide a compact RS-232 control port for test and measurement instruments that already operate from a 5 V logic rail. The 120 kbps interface rate is sufficient for remote commands, calibration records, measurement-result transfers, and equipment self-tests. On-board DC-DC converters reduce the external power-component count, making the device useful where panel space is constrained. The two-driver, two-receiver organization supports flexible test fixtures and adapters. Keep the transceiver away from high-voltage switching stages, and use the manufacturer pin description and external-capacitor layout to avoid introducing signal-integrity problems near sensitive measurement circuitry.
Recommandé
Service and Configuration Port
A service port built around the ADM233LJNZ can provide reliable configuration access for network appliances, industrial controllers, and peripheral equipment. The 120 kbps rate is more than adequate for command sequences, boot configuration, and diagnostic text, while the integrated DC-DC system avoids a separate ±12 V supply section. Two driver and two receiver channels allow implementation of a primary bidirectional port and an auxiliary channel when needed. Maintain direct point-to-point routing, provide chassis-to-signal-ground provisions at the connector, and evaluate the complete assembly for electrostatic-discharge and conducted-noise requirements.
Recommandé
Telemetry and Remote Control
The ADM233LJNZ supports telemetry links between a control system and remotely located instruments or vehicle-like industrial equipment. Its 120 kbps ceiling permits periodic status reporting, command acknowledgments, and moderate configuration-file transfers. The single 5 V supply requirement is convenient for embedded systems with limited power architecture, while onboard DC-DC conversion supplies the required RS-232 voltage levels. The two transmitters and two receivers can support separate command and telemetry directions. Because the interface is single-ended, route incoming and outgoing signals to minimize parallel-trace coupling and include appropriate protection at any externally accessible cable connection.
Recommandé
Récapitulatif des produits recommandés
Données de référence d'ingénierie pour ADM233LJNZ — comparaison, recommandations de conception et informations de conformité.
Guide de sélection
Comparaison avec les alternatives
| Paramètre | Ce produit | ADM233LJN | ADM233LAN | ADM233LANZ | MAX203CPP+G36 | MAX203ECPP+G36 |
|---|---|---|---|---|---|---|
| Package | 20-pin PDIP | 20-pin PDIP - same | 20-pin PDIP - same | 20-pin PDIP - same | 20-pin PDIP - same | 20-pin PDIP - same |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Maxim Integrated | Maxim Integrated |
| Device Type | 2/2 RS-232 transceiver | 2/2 RS-232 transceiver | RS-232 transceiver | RS-232 transceiver | RS-232 transceiver | RS-232 transceiver |
Principaux différenciateurs
- Active lifecycle option within the ADM233L family (vs ADM233LJN)
- Single 5 V supply with integrated bipolar generation (vs MAX203CPP+G36)
- Confirmed 2/2 channel arrangement at 120 kbps (vs ADM233LANZ)
Notes de conception
Place the manufacturer-required 1 µF capacitors close to their associated ADM233LJNZ pins, with short ground returns and no intervening test pads where practical. Keep the 5 V trace and capacitor connections compact because they support the internal DC-DC conversion that creates the approximately ±9 V RS-232 swing. Route the external RS-232 lines directly between the transceiver and connector rather than sharing paths with clocks, relay contacts, or switching-converter outputs.
RS-232 is a single-ended interface, so the physical cable route should be kept away from high-current switching nodes and motors. Maintain separation between outgoing TX and incoming RX routes, especially when both are present in the same harness. If the board connects to an external cable, place the connector near the chassis entry and evaluate protection components for the required electrostatic-discharge and surge environment before finalizing the layout.
Do not substitute based only on the 20-pin PDIP outline. Before replacing the ADM233LJNZ with ADM233LJN, ADM233LAN, ADM233LANZ, MAX203CPP+G36, or MAX203ECPP+G36, compare the complete pin-description tables, external-capacitor values, supply requirements, driver and receiver channel assignments, and temperature grades. The ADM233LJN is obsolete, while the operating and qualification details of the other candidates require confirmation before production use.
Informations de conformité
The manufacturer product page and cross-reference information do not establish the requested environmental, lead-free, halogen-free, or conflict-minerals declarations. The device is an industrial and commercial RS-232 interface IC rather than an automotive-qualified AEC-Q100 component.