ADS1210PG4 - 24-Bit Delta-Sigma ADC, 18-PDIP | Texas Instruments
Référence : ADS1210PG4 ✓ Actif| Qté | Prix unitaire | Total |
|---|---|---|
| 1 | $14.5 | $14,50 |
| 10 | $12.95 | $129,50 |
| 100 | $11.4 | $1 140,00 |
| 500 | $10.2 | $5 100,00 |
| 1 000 | $9.1 | $9 100,00 |
ADS1210PG4 Présentation
An ADC (analog-to-digital converter) is a mixed-signal integrated circuit that converts a continuous analog voltage into a discrete digital code; the delta-sigma architecture in particular uses oversampling and noise-shaping to push quantization noise away from the signal band of interest, then decimates to a lower-rate high-resolution output. The ADS1210PG4 sits in the precision data-acquisition tier, well below SAR ADCs in raw speed but well above them in noise-free resolution, making it the device of choice when measuring low-frequency transducer signals such as strain gauges, RTDs, thermocouples, and weigh-scale load cells.
Key features include a differential front end with wide common-mode range, self-calibration of offset and gain, on-chip input buffers, and a flexible SINC^4 digital filter with programmable sample rates from 1 Hz to 16 kHz via an external reference and clock. The integrated PGA provides gains from 1 to 16 in binary steps, allowing small transducer signals (millivolts) to be amplified before conversion and eliminating the need for an external instrumentation amp in many designs. Calibration modes (self, system, background) compensate for drift and PC-board leakage.
Typical applications include industrial weighing scales, process instrumentation (pressure, flow, temperature), smart sensor transmitters, portable medical instrumentation, and laboratory data loggers where single-supply +5V operation, high resolution, and a parallel-through-hole footprint simplify PCB and firmware design. When designing with the ADS1210PG4, treat the analog and digital grounds as split nets joined at a single point beneath the IC, place the 1 nF to 10 uF decoupling capacitors as close as possible to AVDD/DVDD pins, and drive the modulator clock with a clean low-jitter source. The 'G4' suffix denotes the Pb-free (RoHS) finish designation; the underlying silicon is identical to the legacy ADS1210P.
This page synthesizes distributor pricing, drop-in same-package alternatives, and practical design notes that complement rather than duplicate the manufacturer datasheet.
Alternatives de remplacement direct pour ADS1210PG4 — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.
Outil de comparaison rapide — sélectionnez des références alternatives pour une comparaison côte à côte :
ADS1210P
✅ Remplacement direct✓ En stock
$10.95 / unité
Voir la fiche technique →ADS1210PG4
✅ Remplacement direct ⚠️ Spécifications non vérifiées✓ En stock
$9.1 / unité
Voir la fiche technique →ADS1211P
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
ADS1210U/1KG4
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
ADS1259IPWR
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
ADS124S08IPBSR
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
ADS1210PG4 Valeurs maximales et caractéristiques électriques
| Résolution | 24 bits |
| Architecture | Delta-Sigma (Sigma-Delta) |
| Number of Input Channels | 1 differential (4 analog inputs via pin mux) |
| Input Type | Differential, bipolar/unipolar |
| Sampling Rate (Max) | 16 kS/s (19.5 kS/s modulator rate per some listings) |
| Effective Resolution at 10 Hz | 23 bits |
| Effective Resolution at 1 kHz | 20 bits |
| No-Missing-Code Performance | 22 bits |
| Integral Nonlinearity (INL) | 0.0015% (EL) max |
| Programmable Gain Amplifier | 1, 2, 4, 8, 16 |
| Data Interface | Serial, SPI-compatible |
| Tension de référence | External, differential |
| Tension d'alimentation | +5 V single supply |
| Température de fonctionnement | -40C to +85C |
| Boîtier / Format | 18-PDIP (0.300 inch, 7.62 mm) |
| Type de montage | Through-Hole |
| Packaging | Tube |
| Statut RoHS | Compliant (G4 = Pb-free finish) |
Configuration des broches de ADS1210PG4
| Broche 1 | AINP — Positive analog input (differential channel A) |
| Broche 2 | AINN — Negative analog input (differential channel A) |
| Broche 3 | VBIAS — Analog input bias voltage (bypass to AGND) |
| Broche 4 | AGND — Analog ground |
| Broche 5 | VREF+ — Positive reference input |
| Broche 6 | VREF- — Negative reference input |
| Broche 7 | AVDD — Analog +5V supply |
| Broche 8 | DVDD — Digital +5V supply |
| Broche 9 | DGND — Digital ground |
| Broche 10 | XIN — Crystal oscillator input |
| Broche 11 | XOUT — Crystal oscillator output |
| Broche 12 | SCLK — Serial interface clock |
| Broche 13 | SDOUT — Serial data output |
| Broche 14 | SDIN — Serial data input |
| Broche 15 | DRDY — Data ready (active low) |
| Broche 16 | SYNC — Synchronization input |
| Broche 17 | RESET — Reset input |
| Broche 18 | TEST — Test mode (tie to DGND in normal operation) |
Applications typiques
ADS1210PG4 convient pour 7 applications: Industrial Weigh Scales, Process Pressure Transmitters, Temperature Measurement (RTD / Thermocouple), Strain-Gauge and Bridge Sensor Systems, Portable Medical Instrumentation, Laboratory Data Acquisition Systems, Smart Sensor Transmitter Modules.
Industrial Weigh Scales
The ADS1210PG4 fits weigh-scale front ends because its 24-bit resolution and integrated PGA (gains 1-16) directly digitize the millivolt-level output of a load cell bridge without a separate instrumentation amplifier. With 23 effective bits at the 10 Hz output rate typical for static weighing, the converter resolves weight steps well below the resolution of mechanical scale platforms. The differential input accepts the bridge output plus a 5V excitation-derived common-mode voltage, simplifying analog signal chain. Per TI ADS1210 datasheet, on-chip self-calibration cancels offset and gain drift, ensuring long-term stable readings in factory-floor environments with thermal cycling.
Recommandé
Process Pressure Transmitters
The ADS1210PG4 is well-suited to 4-20 mA smart pressure transmitters and process instrumentation because its single +5V supply, low power, and 24-bit noise-free resolution digitize bridge-style pressure transducers with high accuracy. The differential input accepts the bridge output, while the on-chip PGA amplifies low-output sensors. The SPI-compatible serial interface links cleanly to low-cost microcontrollers in 2-wire loop-powered transmitters. According to the TI ADS1210 datasheet, the device supports system calibration, which removes PCB parasitic thermocouple errors introduced by the wiring harness.
Recommandé
Temperature Measurement (RTD / Thermocouple)
The ADS1210PG4 handles RTD and thermocouple thermometry because its integrated PGA (gains up to 16) boosts the small RTD-derived voltage to full-scale, and its 24-bit resolution resolves sub-0.01C temperature steps at 10 Hz data rates typical of thermal monitoring. The differential inputs reject common-mode thermocouple errors introduced by ground loops. Combined with an external precision reference and a current source for RTD excitation, the ADS1210PG4 supports 3-wire and 4-wire RTD measurement topologies. Per TI ADS1210 datasheet, the input common-mode range accommodates grounded-junction thermocouples referenced to AGND.
Recommandé
Strain-Gauge and Bridge Sensor Systems
The ADS1210PG4 is appropriate for strain-gauge signal conditioning where a Wheatstone bridge produces millivolt-level outputs and the design demands 24-bit noise-free resolution. The integrated PGA gains the signal directly without an external instrumentation amplifier, simplifying BOM. The 18-PDIP package through-hole mounting supports rugged mechanical-test fixtures. According to the TI ADS1210 datasheet, the on-chip self and system calibration compensates for bridge zero-offset and gain errors, enabling calibrated strain measurements in structural-health-monitoring systems.
Recommandé
Portable Medical Instrumentation
The ADS1210PG4 fits portable medical devices such as blood-pressure monitors, pulse oximeter front ends, and bedside patient monitors because its low-power single +5V operation, small size, and 24-bit resolution capture low-frequency bioelectric signals with high fidelity. The integrated PGA eliminates external analog stages, saving board space and reducing leakage paths. Per TI ADS1210 datasheet, the low-noise floor at low data rates enables direct digitization of EEG/ECG front-end outputs after a single instrumentation amplifier, simplifying battery-powered medical designs.
Recommandé
Laboratory Data Acquisition Systems
The ADS1210PG4 supports bench-top and laboratory data acquisition cards where the through-hole 18-PDIP package simplifies hand-built prototypes and where 24-bit resolution is required for slow sensor signals (pH meters, ion-selective electrodes, gas analyzers). The SPI serial interface is straightforward to bit-bang from any microcontroller or FPGA. Per TI ADS1210 datasheet, on-chip calibration and the flexible SINC^4 filter produce repeatable, low-noise measurements for laboratory-grade instruments, while the integrated PGA removes the need for external gain stages.
Recommandé
Smart Sensor Transmitter Modules
The ADS1210PG4 powers smart sensor transmitters because it combines a precision 24-bit delta-sigma ADC, integrated PGA, and SPI interface in a single chip, allowing designers to pair it with a low-cost microcontroller for HART, IO-Link, or wireless sensor modules. The differential analog inputs accept transducer outputs directly, while on-chip calibration corrects for sensor-specific offset and gain. According to the TI ADS1210 datasheet, the single +5V supply operation is compatible with industrial 24V loop-powered architectures after a front-end regulator, simplifying field-instrument design.
Recommandé
Récapitulatif des produits recommandés
Données de référence d'ingénierie pour ADS1210PG4 — comparaison, recommandations de conception et informations de conformité.
Guide de sélection
Comparaison avec les alternatives
| Paramètre | Ce produit | ADS1210P | ADS1211P | ADS1210U/1KG4 | ADS1259IPWR | ADS124S08IPBSR |
|---|---|---|---|---|---|---|
| Package | 18-PDIP (0.300 inch, 7.62 mm) | 18-PDIP - same | 18-PDIP - same | 18-SOIC - different footprint, SMT | 20-TSSOP - different | 32-TQFP - different |
| Brand | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments | Texas Instruments |
| Resolution | 24 bits | 24 bits | 24 bits | 24 bits | 24 bits | 24 bits |
| Architecture | Delta-Sigma | Delta-Sigma | Delta-Sigma | Delta-Sigma | Delta-Sigma | Delta-Sigma |
| Max Sample Rate | 16 kS/s | 16 kS/s | 16 kS/s | 16 kS/s | 14.4 kS/s (max data rate) | 4 kS/s |
| Integrated PGA | Yes (1, 2, 4, 8, 16) | Yes (1-16) | Yes (1-16) | Yes (1-16) | Yes | Yes (1-128) |
| Supply Voltage | +5 V single | +5 V single | +5 V single | +5 V single | 3.3 V or 5 V | 2.7 V to 5.25 V |
| Interface | SPI serial | SPI serial | SPI serial | SPI serial | SPI serial | SPI serial |
| Operating Temperature | -40C to +85C | -40C to +85C | -40C to +85C | -40C to +85C | -40C to +85C | -40C to +125C |
| Lead-Free (RoHS) | Yes (G4 finish) | No (legacy SnPb finish) | No | Yes (G4 finish) | Yes | Yes |
Principaux différenciateurs
- Through-hole 18-PDIP package with lead-free (G4) finish (vs ADS1210U (SOIC-18 SMT))
- Single +5V supply with integrated PGA (gains 1-16) (vs ADS124S08IPBSR (32-TQFP, 4-channel, 12 inputs))
- Pin-compatible upgrade path to ADS1211 for higher channel count (vs ADS1211P (multi-channel variant))
Notes de conception
The ADS1210PG4 requires a clean single +5V supply. Place a 10 uF tantalum (or ceramic) bulk capacitor at the board supply input and a 0.1 uF ceramic decoupling capacitor as close as possible to each of the AVDD (pin 7) and DVDD (pin 8) pins. The analog and digital grounds should be joined at a single star point beneath the IC to prevent digital switching noise from corrupting the analog front end. Per TI ADS1210 datasheet, supply ripple above 10 mVpp at the modulator clock frequency can leak through the modulator and degrade noise performance.
Route the analog input traces (AINP, AINN) as a tightly-coupled differential pair on the top layer with a continuous ground plane beneath them, and keep them away from digital lines (SCLK, SDOUT) to minimize capacitive coupling. Place the external reference and crystal components as close to their respective pins as possible. The TI ADS1210 datasheet layout section recommends a guard trace around AINP/AINN tied to AGND to suppress leakage on high-impedance sensor inputs. For through-hole 18-PDIP boards, hand-routing the analog section on a single layer often gives the best noise performance.
Do not leave the TEST pin floating; tie TEST (pin 18) directly to DGND to disable factory test modes. Ensure the XIN/XOUT crystal or external clock source meets the datasheet drive-level requirements; a low-amplitude or noisy clock couples directly into the modulator and degrades effective resolution. Always run on-chip self-calibration after power-up and after any change in PGA gain, reference voltage, or sample rate, because uncorrected offset can exceed several LSB at high PGA settings. Estimated: at gain=16 and 10 Hz output rate, uncorrected input-referred offset can shift readings by tens of microvolts if calibration is skipped.
Drive the modulator clock from a low-jitter source (crystal oscillator preferred over RC) because clock jitter is multiplied by the delta-sigma loop gain and appears as broadband noise on the output. The TI ADS1210 datasheet specifies a 60 kHz to 60 MHz modulator clock range; for 10 Hz output rate the modulator runs at a high oversampling ratio, so even 100 ns of clock jitter has a measurable effect on effective resolution. If synchronization across multiple ADS1210PG4 channels is required, drive all XIN pins from a common clock and use the SYNC pin to align conversions.
Informations de conformité
The 'G4' finish designation indicates Pb-free (RoHS-compliant) terminal plating. AEC-Q100 automotive qualification is NOT available for this part; use a TI automotive-grade ADC (e.g. ADS131A04-Q1) if automotive compliance is required.