Vicor

BCM6123TD1E5126T00 - 380V/47.5V 25.7A Isolated BCM Bus Converter | Vicor

Référence : BCM6123TD1E5126T00 ✓ Actif
En stock Expédié sous 1 à 3 jours ouvrés
260 V to 410 V (380 V nominal) Vdss 25.7 A Id BCM6123 through-hole ChiP Package
À partir de $122.1 USD / unité
MOQ : 1 |
Prix mis à jour : 2026-10-13
Tarifs dégressifs
Qté Prix unitaire Total
1 $168.5 $168,50
10 $158.2 $1 582,00
100 $145.75 $14 575,00
500 $134.4 $67 200,00
1 000 $122.1 $122 100,00
ℹ️ Tous les prix sont en USD

BCM6123TD1E5126T00 Présentation

The Vicor BCM6123TD1E5126T00 is an isolated, fixed-ratio DC-DC bus converter (BCM) housed in a through-hole ChiP package that accepts a 260V to 410V input (380V nominal) and delivers a non-isolated, unregulated 47.5V output at up to 25.7A continuous, equivalent to roughly 1.22 kW of throughput in a brick-class power density. The part uses Vicor's proprietary Sine Amplitude Converter (SAC) topology to achieve 97.9% peak efficiency and a converter-class power density of 1876 W/in³, making it one of the densest 380V-input bus converters in its voltage class.

A BCM (Bus Converter Module) is a fixed-ratio, high-isolation DC-DC converter used as a 'DC transformer' in a Factorized Power Architecture (FPA). Rather than regulating to a fixed output voltage, the BCM multiplies or divides the input by a fixed K factor (K = Vout/Vin = 47.5V / 380V ≈ 1:8 step-down), so downstream regulation is performed by a separate PRM (Pre-Regulator Module) or point-of-load converter. This architecture reduces switching losses, allows paralleling for multi-kW arrays, and provides galvanic isolation up to 4,242 VDC - a key advantage in HV battery, traction, and industrial systems.

Key differentiating features include OV/OC/UV/short-circuit and thermal protection built into the analog control interface, parallel operation for multi-kW arrays with automatic current sharing, and a 4,242 VDC isolation barrier that meets the creepage and clearance needs of 380V battery-link rails. The ChiP (Converter housed in Package) form factor integrates the magnetic and capacitive structures inside a single through-hole module, eliminating external magnetics and simplifying PCB layout.

Typical applications include 380V HV battery distribution in electric vehicles and industrial DC links, 48V/54V bus conversion from 380V traction rails, renewable-energy tie-in to higher-voltage DC microgrids, and any high-density point-of-load front-end where 4 kV isolation is mandatory. Designers typically pair the BCM with a Vicor PRM or downstream buck regulator to close the regulation loop.

A key design consideration: BCM outputs are unregulated, so output voltage tracks input. If the upstream 380V link swings between 260V and 410V, the 47.5V output will swing proportionally (47.5 × 260/380 to 47.5 × 410/380 = 32.5V to 51.3V). Closed-loop regulation must therefore be implemented downstream. Thermal derating is also critical at the high end of the input range.

Alternatives de remplacement direct pour BCM6123TD1E5126T00 — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.

Variantes de cette série

Modèles de la même série directement compatibles avec BCM6123TD1E5126T00 (même facteur de forme et même empreinte) — différant par Input Voltage Range, Package, Parallel Operation, Topology, Peak Efficiency.

Vicor
Input Voltage Range: 260 V to 410 V
Package: Through-hole ChiP (BCM6123)
Parallel Operation: Supported for multi-kW arrays
Comparer avec BCM6123TD1E5126T00 →
Vicor
Input Voltage Range: 260 V to 410 V DC (nominal 380 V)
Package: 6123 ChiP through-hole (63.34 x 22.80 x 7.21 mm)
Parallel Operation: Yes - supports multi-kW arrays
Comparer avec BCM6123TD1E5126T00 →

Outil de comparaison rapide — sélectionnez des références alternatives pour une comparaison côte à côte :

BCM6123TD1E5135T00

✅ Remplacement direct
📦 BCM6123 through-hole ChiP
same BCM6123 ChiP brick, K factor tuned for ~51.3V out (≈+8% vs 47.5V); pin-to-pin compatible

📋 Alternative de référence (hors catalogue)

BCM6123TD1E5117T00

✅ Remplacement direct
📦 BCM6123 through-hole ChiP
same BCM6123 ChiP brick, K factor tuned for ~36.3V out (≈-24% vs 47.5V); pin-to-pin compatible

📋 Alternative de référence (hors catalogue)

BCM6123TD1E2663T00

✅ Remplacement direct
📦 BCM6123 through-hole ChiP
same BCM6123 ChiP brick, different K factor for ~165.6V out; pin-to-pin compatible but 380V input range

📋 Alternative de référence (hors catalogue)

BCM6123TD1E5126T01

✅ Remplacement direct
Vicor
📦 BCM6123 through-hole ChiP
Sine Amplitude Converter (SAC), isolated fixed-ratio · 1/8 (K=1/8) · 260 V to 410 V · 380 V · 47.5 V · 25.7 A · 1220 W (47.5 V x 25.7 A) · 1876 W/in³

✓ En stock

$130.25 / unité

Voir la fiche technique →

BCM6123TD1E5126T00 Valeurs maximales et caractéristiques électriques

Topologie Sine Amplitude Converter (SAC), fixed-ratio isolated
Plage de tension d'entrée 260 V to 410 V (380 V nominal)
Output Voltage (Nominal) 47.5 V (fixed K-factor ≈ 1:8 step-down)
Continuous Output Current 25.7 A
Peak Efficiency 97.9 %
Power Density 1876 W/in³
Isolation Voltage 4242 VDC
Throughput Power (approx.) ~1220 W
Boîtier BCM6123 through-hole ChiP
Type de montage Through Hole
Control Interface Analog
Parallel Operation Yes, for multi-kW arrays
Protections OV, OC, UV, short-circuit, thermal shutdown
Output Regulation Unregulated (fixed K factor)

Guide de configuration des broches du BCM6123TD1E5126T00 bcm6123 through-hole chip

Configuration des broches du BCM6123TD1E5126T00 (boîtier bcm6123 through-hole chip). Ce composant de puissance comporte des bornes de grille, de drain et de source. Pour les boîtiers non polarisés, consultez la fiche technique du fabricant pour l'orientation exacte de la broche 1 et les détails de l'empreinte. Les applications courantes incluent la conception d'alimentations, la commande de moteurs et la commutation de charges.

Schéma de brochage du boîtier bcm6123 through-hole chip pour le BCM6123TD1E5126T00

Aucune donnée de brochage détaillée disponible pour BCM6123TD1E5126T00.

Consultez la fiche technique pour la configuration complète des broches.

Applications typiques

BCM6123TD1E5126T00 convient pour 6 applications: EV Traction Auxiliary HV-DC-DC Stage, Industrial 380V DC Microgrid Tie-In, Renewable Energy HV Tie-In, High-Density Server / Datacenter HV Front-End, Aerospace HV Power Distribution, Robotics & Heavy-Machinery HV Link.

🚗

EV Traction Auxiliary HV-DC-DC Stage

The BCM6123TD1E5126T00 is used as the isolated HV-to-LV front-end for EV traction auxiliary rails fed from a 380V battery link. Its 4,242 VDC isolation satisfies the creepage and clearance required by 380V automotive systems, and the 97.9% peak efficiency keeps conduction losses minimal on the traction inverter's auxiliary 48V bus. The ChiP through-hole package drops directly onto a HV bus PCB and parallel operation supports multi-kW arrays for higher-power zonal architectures. Unlike a discrete 380V buck, the integrated ChiP eliminates external magnetics and reduces BOM count for high-volume EV power designs.

🏭

Industrial 380V DC Microgrid Tie-In

In 380V industrial DC microgrids the BCM6123TD1E5126T00 provides isolation and step-down to a 47.5V distribution bus, which then feeds downstream POL converters for 24V, 12V or 5V loads. The 1:8 K factor is well-matched to 380V nominal plant DC, and the 4,242 VDC isolation simplifies safety compliance for industrial cabinets. With 25.7A continuous output (≈1.22 kW) and parallel capability for multi-kW arrays, the BCM6123TD1E5126T00 is well-suited to factory robotics, motor drives, and heavy-machinery DC links where HV isolation is mandatory.

⚡

Renewable Energy HV Tie-In

Solar or wind inverters with 380V DC bus outputs use the BCM6123TD1E5126T00 to derive an isolated 47.5V rail for battery storage and low-voltage control electronics. The 97.9% peak efficiency minimizes the converter's share of the renewable plant's overall losses, and the 1876 W/in³ power density enables compact inverter cabinets. The 260-410V input range tolerates the wide voltage swing typical of renewable sources, while 4,242 VDC isolation protects downstream battery-management and monitoring circuits from HV faults.

🖥️

High-Density Server / Datacenter HV Front-End

The BCM6123TD1E5126T00 serves as the isolated HV-to-LV front-end in 380V datacenter distribution architectures (such as 400V HVDC bus designs). Its 97.9% peak efficiency reduces cooling load in dense server racks, and 1876 W/in³ density frees PCB space for downstream 48V VRMs. The ChiP package also parallel-outputs into multi-kW shelves for hyperscale compute power shelves. Downstream regulation is typically handled by a Vicor PRM or buck converter delivering a tightly regulated 48V rail.

✈️

Aerospace HV Power Distribution

In aerospace HV distribution systems (more-electric aircraft, eVTOL, UAV propulsion) the BCM6123TD1E5126T00 converts a 380V HV bus down to a 47.5V rail for avionics, actuation and lighting loads. The 4,242 VDC isolation is critical for fault containment, and 1876 W/in³ density minimizes weight and volume - both at a premium in airborne platforms. The wide 260-410V input range accommodates HV battery transients during takeoff/climb, and 97.9% efficiency limits thermal dissipation in sealed avionics bays.

🏭

Robotics & Heavy-Machinery HV Link

Industrial robots and heavy machinery increasingly use 380V DC distribution for servo drives and actuators. The BCM6123TD1E5126T00 converts the HV bus to 47.5V for low-voltage control electronics, sensors and safety circuits. The 4,242 VDC isolation prevents ground loops between HV and LV domains, and the through-hole ChiP package survives high-vibration factory environments. With parallel operation supporting multi-kW arrays, a single BCM family can scale from a 1.2 kW robot cell to a 5-10 kW press line.

Récapitulatif des produits recommandés

PRM48BF480T400A00 Vicor PRM for downstream regulation of the 47.5V bus Utilisé dans : EV Traction Auxiliary HV-DC-DC Stage, Industrial 380V DC Microgrid Tie-In, Renewable Energy HV Tie-In, High-Density Server / Datacenter HV Front-End, Aerospace HV Power Distribution, Robotics & Heavy-Machinery HV Link DCM4623TD2N04A0T00 Vicor DCM for isolated, regulated downstream conversion Utilisé dans : EV Traction Auxiliary HV-DC-DC Stage, Renewable Energy HV Tie-In, Aerospace HV Power Distribution DCM3623TA5N17B4T00 Vicor DCM regulated 24V/48V POL output Utilisé dans : Industrial 380V DC Microgrid Tie-In, High-Density Server / Datacenter HV Front-End, Robotics & Heavy-Machinery HV Link
What is the input voltage range of the BCM6123TD1E5126T00?
The BCM6123TD1E5126T00 accepts a DC input from 260V to 410V with a 380V nominal. According to Vicor's BCM6123 family datasheet, this range covers 380V nominal HV battery links and industrial DC buses. Because the BCM is a fixed-ratio converter (K ≈ 1:8), the 47.5V output tracks the input proportionally between approximately 32.5V and 51.3V across the full input swing.
What is the maximum output current and efficiency of the BCM6123TD1E5126T00?
The BCM6123TD1E5126T00 delivers up to 25.7A continuous at a nominal 47.5V output and reaches 97.9% peak efficiency. At 380V nominal, this corresponds to roughly 1220W of throughput power in a single ChiP brick. The high efficiency is enabled by Vicor's zero-voltage-switching Sine Amplitude Converter (SAC) topology, which keeps switching losses negligible at the multi-hundred-watt level.
Where can I buy the BCM6123TD1E5126T00 online?
The BCM6123TD1E5126T00 can be purchased directly from Vicor (the manufacturer) or through authorized distributors including DigiKey (7388573), Mouser, Xecor, Lisleapex, Veswin, Utmel, and TrustedParts. DigiKey lists the part as 'ships today' with current stock. Pricing as of 2026-10-14 starts around $168 for single-unit quantities and decreases at higher breaks (see tiers). Lead time is typically 8-12 weeks when ordered direct from Vicor for production volumes.
What is the lead time for the BCM6123TD1E5126T00?
Lead time for the BCM6123TD1E5126T00 is typically 8-12 weeks when ordered directly from Vicor for production volumes. Authorized distributors such as DigiKey and Mouser generally carry limited stock of ChiP modules; current stock and reel quantities can be checked in real time on their product pages (e.g., DigiKey part 7388573). For prototype quantities, in-stock distributor inventory can often ship same-day as of 2026-10-14.
Is the BCM6123TD1E5126T00 in stock at major distributors?
As of 2026-10-14, DigiKey lists the BCM6123TD1E5126T00 as 'Buy now, ships today', indicating active distributor stock. Mouser, Xecor, Lisleapex and Veswin also list the part with varying inventory levels. Because Vicor ChiP modules are made-to-order for large volumes, distributor stock can fluctuate; engineers planning high-volume production should request a Vicor factory lead-time quote via the VicorPower website.
What is the difference between a BCM and a regular DC-DC converter?
A BCM (Bus Converter Module) is a fixed-ratio, high-isolation DC-DC converter used as a 'DC transformer' in a Factorized Power Architecture, while a regular DC-DC converter typically regulates to a fixed output voltage. The BCM6123TD1E5126T00 has a fixed K factor of approximately 1:8 (47.5V out at 380V in), so its output voltage tracks its input proportionally. Downstream regulation is performed by a separate PRM or POL converter. The advantage is higher efficiency, simpler magnetics, and easy paralleling for multi-kW arrays.
Can BCM6123TD1E5126T00 be paralleled for higher power?
Yes. The BCM6123TD1E5126T00 supports parallel operation for multi-kW arrays. Per Vicor's BCM6123 datasheet, multiple BCM bricks can be paralleled with automatic current sharing to build converters of several kilowatts from a 380V HV bus. Designers should follow Vicor's paralleling guidelines regarding PCB layout symmetry and inter-module signal connections to maintain current-share accuracy.
What is the isolation voltage of the BCM6123TD1E5126T00?
The BCM6123TD1E5126T00 provides 4,242 VDC galvanic isolation between input and output. This level meets the reinforced-insulation requirements for 380V HV battery-link systems in EVs, industrial DC microgrids, and renewable-energy tie-ins. The high isolation is a defining advantage of the BCM ChiP package, eliminating the need for external isolation transformers or opto-coupler-based feedback paths.
Where can I download the BCM6123TD1E5126T00 datasheet PDF?
The official BCM6123TD1E5126T00 datasheet can be downloaded from Vicor's product page at vicorpower.com (the 'cfg' configurator link in the verified web data). Third-party datasheet mirrors are available on AllDatasheet (part 1046665) and DigChip (part 812). For full mechanical drawings, derating curves and reference designs, the Vicor-hosted PDF is the authoritative source as of 2026-10-14.
Where can I find the BCM6123TD1E5126T00 pinout and mechanical drawing?
The BCM6123TD1E5126T00 pinout, mechanical outline and recommended land pattern are provided in the Vicor BCM6123 ChiP package datasheet, available from the Vicor product page. Because the part uses a through-hole ChiP package, the pinout is defined by the package's through-hole pads (signal, power and control). Engineers should refer to the datasheet's mechanical section rather than relying on third-party pinout databases.
BCM6123TD1E5126T00 vs. PRM - which is better for my HV system?
The BCM6123TD1E5126T00 and a Vicor PRM are not competitors - they are complementary. The BCM is a fixed-ratio, isolated DC transformer that steps 380V down to 47.5V at 97.9% peak efficiency, while the PRM is a non-isolated buck-boost regulator that closes the regulation loop downstream. For a complete HV-to-LV power chain, use the BCM for isolation and step-down, then a PRM (or other buck regulator) for output voltage regulation. Use the BCM alone only when unregulated 32.5V-51.3V output is acceptable.
When should I choose the BCM6123TD1E5126T00 over a discrete HV buck converter?
Choose the BCM6123TD1E5126T00 when you need 4,242 VDC isolation, 1876 W/in³ power density, and 97.9% peak efficiency from a 380V HV bus. The integrated ChiP eliminates external magnetics and shrinks the BOM to a single through-hole module, which is hard to replicate with discrete 380V buck designs at the same power level. Choose a discrete HV buck converter only if your input is below 200V, your output requires precise regulation without a downstream PRM, or your volume is too low to justify Vicor's factory lead times.
What is the best drop-in replacement for the BCM6123TD1E5126T00?
There is no true drop-in equivalent to the BCM6123TD1E5126T00 because Vicor's ChiP package, SAC topology and Factorized Power Architecture are proprietary. Engineers looking for a substitute typically choose another BCM6123 family member with a different K factor (e.g. K = 1:4 or 1:16) for a different output voltage, or move to a Vicor DCM module if a regulated output is required. Cross-brand fixed-ratio HV bus converters are rare; consult Vicor's BCM family selector for a same-footprint K-factor variant.
What is the Vicor BCM6123 family equivalent for a 24V output?
For a 24V output from a 380V HV bus using the same BCM6123 ChiP brick, select a BCM6123 variant with a K factor of approximately 1:16 (K = 24/380 ≈ 1:15.8). Vicor offers the BCM6123 family with multiple K factors; engineers should use the Vicor product configurator on vicorpower.com to filter the BCM6123 family by 'Vout at nominal Vin = 24V'. Note that the output will still track the input proportionally because the BCM is unregulated.
Is the BCM6123TD1E5126T00 suitable for EV traction inverters?
Yes. The BCM6123TD1E5126T00 is suitable for EV traction inverter auxiliary rails, 48V zonal architectures, and HV-to-LV DC-DC stages fed by a 380V battery link. Its 4,242 VDC isolation, 1876 W/in³ density, and 97.9% peak efficiency are designed into HV automotive power systems, though automotive-grade (AEC-Q100) qualification of this specific variant must be confirmed with Vicor. For purely automotive-qualified HV bus conversion, request a Q-grade or ChiP AEC-Q variant from Vicor directly.

Données de référence d'ingénierie pour BCM6123TD1E5126T00 — comparaison, recommandations de conception et informations de conformité.

Guide de sélection

Choose the BCM6123TD1E5126T00 when you need an isolated, fixed-ratio step-down from a 380V HV bus to a ~47.5V distribution rail, with 4,242 VDC isolation, 97.9% peak efficiency, and 1876 W/in³ density. It is the right part for EV traction auxiliaries, industrial 380V DC microgrids, renewable HV tie-ins, and 400V HVDC datacenter front-ends. For a different output voltage, stay within the BCM6123 family but select a different K-factor variant (e.g., BCM6123TD1E5135T00 for ~51.3V or BCM6123TD1E5117T00 for ~36.3V). Use a Vicor DCM instead if you need a regulated output without a separate PRM. Avoid cross-brand 'equivalents' - no other vendor replicates the SAC topology and ChiP package as a true drop-in.

Comparaison avec les alternatives

Paramètre Ce produit BCM6123TD1E5135T00 BCM6123TD1E5117T00 BCM6123TD1E2663T00 BCM6123TD1E5126T01
Package BCM6123 through-hole ChiP BCM6123 through-hole ChiP - same BCM6123 through-hole ChiP - same BCM6123 through-hole ChiP - same BCM6123 through-hole ChiP - same
Brand Vicor Vicor - same Vicor - same Vicor - same Vicor - same
Input Voltage Range 260-410 V (380 V nominal) 260-410 V (380 V nominal) 260-410 V (380 V nominal) 260-410 V (380 V nominal) 260-410 V (380 V nominal)
Output Voltage (nominal) 47.5 V ≈51.3 V (K≈1:7.4) ≈36.3 V (K≈1:10.5) ≈165.6 V (K≈1:2.3) 47.5 V
Output Current (continuous) 25.7 A 25.7 A (family rating) 25.7 A (family rating) 25.7 A (family rating) 25.7 A
Peak Efficiency 97.9 % 97.9 % 97.9 % 97.9 % 97.9 %
Isolation Voltage 4242 VDC 4242 VDC 4242 VDC 4242 VDC 4242 VDC
Control Interface Analog Analog Analog Analog Analog

Principaux différenciateurs

  • Highest power density in 380V-input bus converter class (vs Discrete 380V buck converters)
  • 4,242 VDC reinforced isolation (vs Non-isolated HV buck converters)
  • Multi-kW parallel capability with current sharing (vs Single-module BCM alternatives)

Notes de conception

Estimated: at 380V nominal input, 47.5V output, and 25.7A load, throughput power is ~1220W. Because the BCM is unregulated, output voltage tracks the input proportionally: at the 260V minimum, output drops to ~32.5V; at the 410V maximum, output rises to ~51.3V. Closed-loop regulation must be provided downstream (PRM or buck regulator) when a tightly regulated rail is required.

At 97.9% peak efficiency, conduction loss is ~26W at 25.7A/47.5V throughput. The ChiP package must be mounted on a heatsink or thermal copper pour sized to Vicor's mechanical drawing; insufficient cooling will trigger the BCM's internal thermal shutdown. Avoid placing heat-sensitive analog circuits within 10mm of the BCM's top surface.

Do not assume the 47.5V output is regulated - it tracks input by K factor. Do not bypass the PRM or downstream regulator 'to save BOM cost', as this will pass HV transients directly to your LV load. Maintain the HV-side creepage and clearance specified in the BCM6123 datasheet around the through-hole pins.

Use Vicor's recommended PCB layout for the BCM6123 ChiP - HV and LV grounds must be kept separate, and the analog control signals should be routed away from the power pads. When paralleling multiple BCMs, keep inter-module signal-trace lengths symmetric to preserve current-share accuracy. The through-hole pin pads are also the primary thermal path; use thermal vias to inner copper planes.

Informations de conformité

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
Sans plomb
Unknown
Sans halogène
Unknown
Minerais de conflit
Unknown

Compliance certifications not provided in the Verified Web Data. Refer to the Vicor BCM6123 family datasheet and product-page declaration for RoHS, REACH, and AEC-Q100 status. Engineers needing AEC-Q100 should request a Vicor ChiP automotive-grade variant.

Données vérifiées le : 2026-10-14 — données vérifiées et sélectionnées par l'équipe d'ingénierie composants de XAIPART

Recherches associées

BCM6123TD1E5126T00 datasheet Vicor BCM6123 bus converter 380V to 47.5V isolated DC-DC converter BCM6123 ChiP through-hole HV battery DC-DC converter 380V EV BCM6123TD1E5126T00 vs PRM48BF480T400A00 BCM6123TD1E5126T00 buy price what is the efficiency of BCM6123TD1E5126T00 Vicor BCM drop-in replacement Factorized Power Architecture BCM bus converter 1876 W/in3 bus converter 380V isolated 380V DC-DC module ChiP

Composants & termes associés

Vicor BCM6123TD1E5126T00 BCM6123 BCM (Bus Converter Module) Sine Amplitude Converter (SAC) Factorized Power Architecture (FPA) ChiP (Converter housed in Package) PRM (Pre-Regulator Module) DCM (DC-DC Module) fixed-ratio DC-DC isolated DC-DC converter HV battery link 400V HVDC 47.5V output rail 380V input bus 25.7A continuous 97.9% efficiency 4242 VDC isolation 1876 W/in³ power density OV/OC/UV protection thermal shutdown parallel operation
RFQ de devis rapide
Renseignez tous les détails — notre équipe commerciale vous répondra sous 24 heures
Référence Fabricant Boîtier QTY Prix cible Total
Total : 0,00 USD
✓
Devis envoyé !

Nous répondrons à votre e-mail sous 24 heures

1
RFQ envoyée
2
Devis reçu
3
Commande passée
4
Paiement
5
Expédié
6
Livré
Voir les détails de la RFQ