CD4017BM - 10MHz CMOS Decade Counter | Texas Instruments
Référence : CD4017BM ✓ ActifCD4017BM Présentation
A decade counter is a sequential digital logic device that cycles through ten states. The CD4017BM combines a counter stage with ten individually decoded outputs, allowing one output to become active for each count state. In the broader semiconductor hierarchy, it belongs to the CD4000 CMOS logic family and functions as a counter and divider within general-purpose logic ICs. Its decoded outputs reduce the need for external binary decoding, simplifying many sequential-control designs.
The CD4017BM operates from the CD4000B series supply range identified in the manufacturer documentation for 5 V, 10 V, and 15 V parametric ratings. Its 10 MHz typical operating frequency is specified at 10 V peak-to-peak, so a power supply at or near 10 V provides the highest stated operating point in the available technical information. The counter also features standardized, symmetrical output characteristics and is tested for quiescent current at 20 V.
The Schmitt-trigger clock input helps reject slow transitions and electrical noise, while the separate clock-inhibit and reset inputs provide flexible control over counting. The ten decoded outputs support cyclic activation of one load at a time. Reset returns the counting sequence to its defined initial state, while clock inhibit allows the count to be held without disconnecting the clock source. These characteristics are useful in industrial controls, test fixtures, indicators, and embedded sequencing systems.
The part is suited to designs requiring more than ten count positions, particularly when individual decoded outputs are preferable to binary-coded outputs. It can implement decade sequencing, programmable timing references, step-counting mechanisms, and rotating indicators. Designers should account for unused outputs, supply decoupling, input pulse timing, and the propagation delays between clock transitions and decoded output changes when constructing reliable control circuits.
A key implementation consideration is that the operating frequency and output timing depend on supply voltage. The 10 MHz figure is a typical condition at 10 V peak-to-peak rather than a guarantee at every supply voltage. Confirm timing margins against the slowest valid supply and verify reset or inhibit behavior before using multiple decoded outputs to control safety-critical loads.
This product page combines the manufacturer-device identity, package information, functional characteristics, practical application guidance, verified source links, and same-footprint replacement information to support faster engineering evaluation and sourcing decisions.
Alternatives de remplacement direct pour CD4017BM — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.
Variantes de cette série
Modèles de la même série directement compatibles avec CD4017BM (même facteur de forme et même empreinte) — différant par Logic Family, Mounting Type, Package.
CD4017BMG4
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
CD4017BE
✅ Remplacement direct ⚠️ Spécifications non vérifiéesContactez-nous pour le prix
Voir la fiche technique →CD4017BM Valeurs maximales et caractéristiques électriques
| Product Type | CMOS decade counter with 10 decoded outputs |
| Logic Family | CD4000B CMOS |
| Typical Operating Frequency | 10 MHz at 10 V peak-to-peak |
| Counter Outputs | 10 decoded outputs |
| Number of Counter Elements | 1 element |
| Counter Width | 10-bit decade count sequence |
| Counting Edge | Positive clock transition |
| Clock Input Logic | Schmitt-trigger action |
| Clock Inhibit Input | Yes |
| Reset Input | Yes |
| Parametric Rating Supply Voltages | 5 V, 10 V, and 15 V |
| Quiescent Current Test Voltage | 20 V |
| Output Characteristics | Standardized and symmetrical |
| Operation Mode | Fully static |
| Boîtier | 16-pin SOIC |
| Type de montage | Surface mount |
Configuration des broches de CD4017BM
| Broche 1 | CLK — Clock input with Schmitt-trigger action |
| Broche 2 | CLKINH — Clock inhibit input |
| Broche 3 | RESET — Counter reset input |
| Broche 4 | Q0 — Decoded counter output 0 |
| Broche 5 | Q1 — Decoded counter output 1 |
| Broche 6 | Q2 — Decoded counter output 2 |
| Broche 7 | Q3 — Decoded counter output 3 |
| Broche 8 | VSS — Ground reference |
| Broche 9 | Q7 — Decoded counter output 7 |
| Broche 10 | Q6 — Decoded counter output 6 |
| Broche 11 | Q5 — Decoded counter output 5 |
| Broche 12 | Q4 — Decoded counter output 4 |
| Broche 13 | NC — Not connected |
| Broche 14 | Q9 — Decoded counter output 9 |
| Broche 15 | Q8 — Decoded counter output 8 |
| Broche 16 | VDD — Positive supply voltage |
Applications typiques
CD4017BM convient pour 6 applications: Stepper-Motor Phase Sequencing, Sequential LED Lighting, Industrial Test Sequence Control, Timer and Preset Selector, Traffic and Display Sequence Control, Digital State Machine.
Stepper-Motor Phase Sequencing
The CD4017BM suits basic stepper-motor sequencing because its ten decoded outputs provide sequential phase selection without an external binary decoder. A clock pulse advances one output at a time, while clock inhibit can pause the sequence and reset can establish a known starting phase. The 10 MHz typical operating frequency at 10 V peak-to-peak provides substantial timing margin for ordinary low-rate motor stepping. Because the decoded outputs are logic signals rather than power-stage drivers, the design must use suitable transistor or driver circuitry for the motor windings.
Recommandé
Sequential LED Lighting
The ten decoded outputs of the CD4017BM can rotate a group of indicators or lamps, creating moving-light, chase, or rotating display patterns with a small logic footprint. Each positive clock transition advances one decoded state when clock inhibit remains low. At the documented 10 MHz typical frequency under a 10 V peak-to-peak condition, the counter is far faster than most visual lighting sequences, so a slower clock divider can provide the intended timing. Current limiting and suitable switching stages remain necessary for LEDs or higher-current loads.
Recommandé
Industrial Test Sequence Control
A decade counter is useful in test fixtures that must activate test points, relay stages, or status indicators in a repeatable sequence. The CD4017BM provides one decoded output per count state, while reset returns the fixture to a known condition and clock inhibit provides a pause control. The Schmitt-trigger clock input improves transition handling for slow or noisy control signals. Fixture timing should be derived from a separate stable oscillator, and output loads must remain within the electrical ratings specified by the manufacturer datasheet.
Recommandé
Timer and Preset Selector
The CD4017BM can act as a ten-position timer or preset selector by combining a periodic clock with one of its decoded outputs. A chosen output can become the reference for a downstream timing interval, while reset establishes repeatable starting conditions and clock inhibit can extend a timing sequence. This approach simplifies designs that need more selection points than are available from a simple binary divider. Account for output propagation delay when two decoded states are used to form boundaries, and verify behavior across the intended supply voltage.
Recommandé
Traffic and Display Sequence Control
The ten decoded outputs support rotating indicators, warning sequences, and multiplexed display phases in control panels. Advancing the counter changes only the selected decoded state, allowing external circuitry to activate the corresponding lamp, relay, or display segment. The Schmitt-trigger clock helps reject slowly changing control transitions, while clock inhibit permits the sequence to be stopped without losing the clock connection. Designers should use suitable isolation or drive circuits for loads and must not treat a logic output as a direct power switch.
Recommandé
Digital State Machine
For simple sequential systems, the CD4017BM can implement a ten-state controller whose decoded outputs represent distinct phases of an operation. A clock event advances the active phase, reset initializes the process, and clock inhibit holds the current phase. This arrangement is useful for dispensing, batch-control, educational, and prototype sequencing where ten discrete states are required. The counter should be clocked from a clean source, and the design must prevent asynchronous reset or inhibit signals from producing unintended transitions near critical operating boundaries.
Recommandé
Données de référence d'ingénierie pour CD4017BM — comparaison, recommandations de conception et informations de conformité.
Guide de sélection
Comparaison avec les alternatives
| Paramètre | Ce produit | CD4017BMG4 | CD4017BE |
|---|---|---|---|
| Brand | Texas Instruments | Texas Instruments | Texas Instruments |
| Package | 16-pin SOIC | 16-pin SOIC - same | 16-pin SOIC - same |
| Counter Type | CMOS decade counter | CMOS decade counter | CMOS decade counter |
| Decoded Outputs | 10 outputs | 10 outputs | 10 outputs |
| Typical Operating Frequency | 10 MHz at 10 V peak-to-peak | 10 MHz at 10 V peak-to-peak | 10 MHz at 10 V peak-to-peak |
| Counting Edge | Positive clock transition | Positive clock transition | Positive clock transition |
| Clock Input | Schmitt-trigger action | Schmitt-trigger action | Schmitt-trigger action |
| Control Inputs | Clock inhibit and reset | Clock inhibit and reset | Clock inhibit and reset |
| Parametric Rating Voltages | 5 V, 10 V, and 15 V | 5 V, 10 V, and 15 V | 5 V, 10 V, and 15 V |
Principaux différenciateurs
- Direct documented package-compatible replacement (vs CD4017BMG4)
- Ten individually decoded outputs (vs CD4017BE)
- Schmitt-trigger clock input supports controlled transitions (vs CD4017BE)
Notes de conception
Connect the supply bypass capacitor directly to the VDD and VSS pins using short traces and a nearby ground return. The Schmitt-trigger clock improves transition handling but does not replace good signal conditioning. Keep the clock, inhibit, and reset nets away from switching-node copper, and use a solid ground plane so decoded output changes do not induce unintended clock edges.
Design clock and reset release timing around the propagation delay between an input transition and the corresponding decoded outputs. Reset and clock inhibit can be asynchronous control signals, so they should not be released close to a clock edge when a race could move the counter to an unintended state. Synchronizing externally generated reset commands or adding appropriate qualification logic improves repeatability.
Do not connect LEDs, relays, or stepper-motor windings directly to the counter outputs. Use transistor, MOSFET, or driver stages sized for the load and include the required flyback protection for inductive loads. Also avoid assuming that 10 MHz applies at every supply voltage: the published figure is typical at 10 V peak-to-peak, and timing must be verified at the circuit’s minimum operating voltage.
Informations de conformité
No explicit RoHS, REACH, lead-free, halogen-free, or conflict-minerals status was identified for the exact CD4017BM ordering code. AEC-Q100 qualification is not indicated.