CD4051BCM - 8:1 240Ohm Analog Switch | onsemi | Multiplexer
Référence : CD4051BCM ✓ ActifCD4051BCM Présentation
An analog multiplexer is a semiconductor switching device that connects multiple signal paths to a shared resource. The broader hierarchy is analog switch, multiplexer or demultiplexer, interface IC, and semiconductor. This topology reduces the number of external pins and interconnects required when a controller must measure multiple analog inputs or distribute an analog signal among several destinations.
The CD4051BCM includes three digital control inputs for channel selection and one inhibit or disable input. Its digital control architecture allows a microcontroller or logic system to select the desired analog path. The principal channel characteristics identified for this device are its 240-ohm ON impedance and very low OFF leakage current, which are important when selecting it for sensor acquisition, signal routing, or precision analog measurement.
The CD4051BCM belongs to the CD4000 CMOS logic family and can operate as either an 8-channel multiplexer or an 8-channel demultiplexer, depending on how the common and individual channel terminals are connected. The 16-SOIC package supports conventional surface-mount assembly, while the device's principal application role remains the selection of one analog signal path from a group of eight.
Typical uses include multiplexed sensor interfaces, laboratory and test equipment, industrial control systems, data acquisition modules, and audio signal routing. It is particularly relevant when eight analog inputs must be presented to a single converter or processor without requiring a separate switch for every input. System designers should still evaluate signal range, switching speed, charge injection, and operating-voltage limits against the application.
For PCB design, keep the selected analog channel traces short and place the device close to the multiplexer output when possible. Route control inputs away from sensitive analog nets, use a solid ground reference, and follow the manufacturer datasheet for decoupling and unused-pin handling. Avoid presenting the logic selects as sufficient protection against excessive input or output voltage.
This page combines the verified product identity, a parameter-focused comparison, practical routing guidance, and carefully qualified replacement information. It distinguishes electrically similar devices from confirmed drop-in choices so engineers can evaluate footprint, control logic, signal integrity, and operating conditions before redesigning a board.
Alternatives de remplacement direct pour CD4051BCM — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.
MC74HC4051ADR2G
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
CD4051BCM Valeurs maximales et caractéristiques électriques
| Circuit Count | 1 circuit |
| Multiplexer Configuration | 8:1 |
| Channel Count | 8 channels |
| On-State Impedance | 240 ohm |
| Off-State Leakage Current | Very low |
| Device Type | Single 8-channel analog multiplexer/demultiplexer |
| Control Type | Digitally controlled |
| Nombre de broches | 16 pins |
| Boîtier | 16-SOIC |
| Type de montage | Surface mount |
| Storage Temperature Range | -65 °C to +150 °C |
| Maximum Power Dissipation | 700 mW |
| Maximum DC Supply Voltage | 18 VDC |
| Technology Family | CD4000 CMOS logic |
Guide de configuration des broches du CD4051BCM 16-soic
Configuration des broches du CD4051BCM (boîtier 16-soic). La numérotation des broches, les fonctions et les schémas de connexion sont définis dans la fiche technique du fabricant. Consultez-la pour l'empreinte exacte et les directives de soudage.
Aucune donnée de brochage détaillée disponible pour CD4051BCM.
Consultez la fiche technique pour la configuration complète des broches.
Applications typiques
CD4051BCM convient pour 6 applications: Multiplexed Sensor Acquisition, Industrial Control Signal Routing, Data Acquisition Modules, Test and Measurement Systems, Audio Signal Routing, Communication and Instrumentation Interfaces.
Multiplexed Sensor Acquisition
The CD4051BCM suits systems that must route one of eight analog sensor outputs into a shared converter or processor channel. Its 8:1 configuration reduces the number of analog connections required at the host device, while the 240-ohm ON impedance establishes the basic loading requirement for the selected source. Place the multiplexer near the sensor or converter interface to minimize additional trace resistance and capacitance. Verify that sensor output voltage, source impedance, acquisition time, and leakage current remain acceptable. The three select inputs can be driven by a microcontroller or logic decoder, but their levels and switching behavior must match the CD4051BCM control truth table.
Recommandé
Industrial Control Signal Routing
The CD4051BCM can route eight analog control or measurement channels through one common interface in industrial equipment. Its low ON impedance of 240 ohms is suitable when the receiving circuit has sufficiently high input impedance, while very low OFF leakage current helps isolate unselected channels. Keep the selected signal path away from digital clock and control routing to reduce coupling. Confirm the operating supply range and temperature rating for the installation environment. The common terminal should connect to the downstream measurement block, and each individual terminal should present a defined state when its channel is not selected.
Recommandé
Data Acquisition Modules
In a compact data-acquisition module, the CD4051BCM provides an efficient way to share one analog input channel among eight sources. Its single 8-channel structure supports both multiplexing and demultiplexing, depending on the external connection arrangement. This can reduce connector count and PCB routing complexity when several slow-changing measurements share one converter. Account for the 240-ohm series resistance when calculating source-loading error, and validate settling time before sampling. The mux should be positioned close to the converter input when the selected signal has a high source impedance or when cable capacitance could slow settling.
Recommandé
Test and Measurement Systems
The CD4051BCM can distribute or select one analog signal among eight destinations in a test fixture or measurement system. Its low OFF leakage current reduces interaction between unselected paths, and the 240-ohm ON impedance supports many high-impedance measurement circuits. Use a defined termination or bias arrangement for every unselected input to prevent floating nodes from introducing noise. Select controls should change only after the previous measurement has settled. Confirm signal amplitude, source impedance, and operating voltage against the datasheet limits before using the device with external test equipment.
Recommandé
Audio Signal Routing
The CD4051BCM may be used for low-bandwidth audio routing when its 240-ohm ON impedance and OFF leakage characteristics are acceptable for the selected path. It is particularly relevant to compact analog selectors that must connect one source to one of several outputs or choose between multiple audio inputs. Keep the audio trace short and provide a stable return path to minimize pickup. The digital selection lines should be driven cleanly and routed away from the audio path. Evaluate channel distortion, attenuation, switching transients, and input bias behavior in the finished circuit because those application-level characteristics depend on the surrounding network.
Recommandé
Communication and Instrumentation Interfaces
The CD4051BCM can select among eight external instrumentation lines in communication equipment or diagnostic interfaces. It provides a practical way to connect multiple analog sources to one processing channel without adding a dedicated package for each source. Place protection components before the mux when the selected lines connect to external connectors, because the device is intended for controlled signal conditions. Use a continuous ground reference and separate return currents from sensitive analog paths. Validate OFF-channel isolation, common-mode behavior, and settling time for the interface bandwidth. The channel-select logic should remain stable during conversion or measurement to avoid switching artifacts.
Recommandé
Récapitulatif des produits recommandés
Données de référence d'ingénierie pour CD4051BCM — comparaison, recommandations de conception et informations de conformité.
Guide de sélection
Comparaison avec les alternatives
| Paramètre | Ce produit | MC74HC4051ADR2G |
|---|---|---|
| Package | 16-SOIC | 16-SOIC |
| Brand | onsemi | onsemi |
| Logic Family | CD4000 CMOS | HC CMOS |
Principaux différenciateurs
- Established CD4000-family 8:1 switching arrangement (vs MC74HC4051ADR2G)
- Very low OFF leakage for unselected analog paths (vs MC74HC4051ADR2G)
- Single package handles eight analog channels (vs MC74HC4051ADR2G)
Notes de conception
Place the CD4051BCM close to the shared analog destination when the source impedance is high or the selected signal must settle quickly. Keep individual-channel and common-terminal traces short, provide a continuous ground reference, and keep the three digital select lines away from sensitive analog nets. Where possible, route the unselected channels toward defined impedances or terminations rather than allowing unused board inputs to float.
Include the 240-ohm ON impedance in the complete signal-path error budget. For a high-impedance receiving circuit this resistance is usually manageable, but it becomes more important with lower source impedance, long cables, high-frequency signals, or precision measurements. Check that the downstream input impedance does not create unacceptable attenuation and verify settling time after each channel change before sampling the converted value.
Do not treat the 18-VDC maximum DC supply rating as a general operating limit. Review the datasheet operating supply range, control-input thresholds, analog signal limits, and absolute-maximum conditions before power-up. Keep the inhibit and select inputs at valid logic levels whenever the analog path is active, and ensure external signals cannot exceed the device's permitted input or output voltage.
Follow the manufacturer datasheet for supply decoupling and unused-pin treatment. Provide a low-impedance ground connection and place any required bypass capacitor adjacent to the device. Because the CD4051BCM handles analog signals, give the common and selected channels a quiet return path and keep switching-node currents out of the sensitive signal reference. Review creepage, clearance, and connector protection when the mux is used with external equipment.
Informations de conformité
Compliance status is not established by the available product listings. The complete ordering information, material declarations, and manufacturer product documentation should be checked before a regulated design is released.