CM600DY-24T Présentation

The Mitsubishi Electric CM600DY-24T is a T-Series standard-type dual (half-bridge) insulated IGBT power module rated 1200 V collector-emitter voltage and 600 A collector current, intended for high-power switching use in a chassis-mount insulated package.

An IGBT (insulated-gate bipolar transistor) module combines multiple IGBT dies with freewheeling diodes on an isolated baseplate, forming the switching stage of a power converter. In the power-electronics hierarchy it sits above discrete transistors and below complete power assemblies: it is the core building block of inverters, converters, and motor drives. The dual (DY) configuration integrates a half bridge - high-side and low-side switch with complementary diodes - so a single module forms a complete inverter leg.

Key features of the T-Series CM600DY-24T include low power loss switching, high reliability construction, and an insulated package that simplifies heatsink mounting and inverter design. According to Mitsubishi Electric, the T-Series standard-type family contributes to energy savings and simplifies inverter design for industrial equipment. The #330G variant adds pre-applied PC-TIM (phase-change thermal interface material) for improved thermal coupling.

The half-bridge topology with integrated freewheeling diodes reduces stray inductance compared with discrete solutions, supporting hard-switched PWM operation in high-current inverters. Screw-terminal connections accept busbar and laminated busbar assemblies typical of high-power layouts.

Typical applications include industrial motor drives, UPS systems, welding power supplies, and servo amplifiers, where 1200 V class devices interface with 400-690 V AC line inputs via a DC bus.

Design consideration: because this is a chassis-mount module, thermal design dominates reliability - verify junction-to-case thermal resistance and heatsink flatness, and apply the manufacturer-specified mounting torque to the terminal and mounting screws to avoid die stress.

This page synthesizes distributor availability data, cross-reference alternatives, and practical design notes not found in the manufacturer datasheet.

Alternatives de remplacement direct pour CM600DY-24T — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.

Variantes de cette série

Modèles de la même série directement compatibles avec CM600DY-24T (même facteur de forme et même empreinte) — différant par Mounting Type, Package Type, Series.

Mitsubishi Electric
Mounting Type: Chassis Mount (screw-terminal)
Package Type: Insulated chassis-mount power module
Series: T-Series, 7th Generation Standard Type
Comparer avec CM600DY-24T →

Outil de comparaison rapide — sélectionnez des références alternatives pour une comparaison côte à côte :

CM600DY-24T#330G

✅ Remplacement direct
📦 Insulated chassis-mount module
identical die and ratings, PC-TIM pre-applied vs user-applied grease

📋 Alternative de référence (hors catalogue)

CM600DX-24T

✅ Remplacement direct
📦 Insulated chassis-mount module
newer X-series technology generation, same dual footprint, lower losses

📋 Alternative de référence (hors catalogue)

CM600DY-24S

✅ Remplacement direct
📦 Insulated chassis-mount module
S-series generation, different VCE(sat)/switching-loss balance

📋 Alternative de référence (hors catalogue)

CM600C1Y-24T

✅ Remplacement direct
📦 Insulated chassis-mount module
same 1200 V class dual package family, differs in internal topology/diode characteristics

📋 Alternative de référence (hors catalogue)

CM600DY-24A

✅ Remplacement direct
📦 Insulated chassis-mount module
A-series standard type, 1200 V 600 A 3670 W, earlier generation with higher losses

📋 Alternative de référence (hors catalogue)

CM600DY-24NFH

✅ Remplacement direct ⚠️ Spécifications non vérifiées
📦 Insulated chassis-mount module
NFH-series generation, same 1200 V 600 A dual footprint, different VCE(sat) class

📋 Alternative de référence (hors catalogue)

CM600DY-24T Valeurs maximales et caractéristiques électriques

Configuration Dual (Half-Bridge)
Collector-Emitter Voltage (VCES) 1200 V
Continuous Collector Current (IC) 600 A
Series T-Series Standard Type
Package Type Insulated chassis-mount module
Type de montage Chassis Mount (screw terminals)
Freewheeling Diode Integrated (dual configuration)
TIM Option CM600DY-24T#330G variant with PC-TIM pre-applied

Guide de configuration des broches du CM600DY-24T insulated chassis-mount module

Configuration des broches du CM600DY-24T (boîtier insulated chassis-mount module). Ce composant de puissance comporte des bornes de grille, de drain et de source. Pour les boîtiers non polarisés, consultez la fiche technique du fabricant pour l'orientation exacte de la broche 1 et les détails de l'empreinte. Les applications courantes incluent la conception d'alimentations, la commande de moteurs et la commutation de charges.

Schéma de brochage du boîtier insulated chassis-mount module pour le CM600DY-24T

Aucune donnée de brochage détaillée disponible pour CM600DY-24T.

Consultez la fiche technique pour la configuration complète des broches.

Zone de fonctionnement sûr

Fonctionnement continu en CC

Applications typiques

CM600DY-24T convient pour 6 applications: Industrial Motor Drives, Uninterruptible Power Supplies (UPS), Welding Power Supplies, Servo Amplifiers, Induction Heating Power Supplies, Renewable Energy Inverters.

🏭

Industrial Motor Drives

The CM600DY-24T fits large-frame 400 V AC industrial motor drives where its 1200 V rating covers DC bus excursions to roughly 800 V and its 600 A per-switch current supports hundreds of kW output. One dual module forms a complete inverter leg; three modules build a full three-phase bridge. Its low-power-loss T-Series technology reduces heatsink demand at typical 2-16 kHz PWM frequencies, while the insulated baseplate permits direct mounting to grounded drive chassis. Use laminated busbars to minimize overvoltage spikes at turn-off, and verify switching-loss budgets against the datasheet curves at your modulation depth and carrier frequency.

⚡

Uninterruptible Power Supplies (UPS)

In three-phase UPS inverters and rectifier stages, the CM600DY-24T provides the 1200 V blocking voltage needed for 400/480 V AC systems and 600 A current capability for high-kVA frames. The half-bridge configuration maps directly to a phase leg of the UPS inverter bridge, minimizing component count and stray inductance. Its integrated freewheeling diodes handle reactive current between battery and load sides. Thermal design should assume continuous full-load conduction plus switching losses, making the PC-TIM-equipped #330G variant attractive for consistent production thermal performance. Gate drivers with DESAT and soft-turn-off protection improve short-circuit survival in utility environments.

🔧

Welding Power Supplies

Heavy-duty industrial welding inverters benefit from the CM600DY-24T's rugged 600 A rating and 1200 V margin, tolerating the repeated load transients and short-circuit events inherent to arc welding. The dual half-bridge supports full-bridge and half-bridge resonant inverter topologies operating at 20-40 kHz, where T-Series low switching losses limit heatsink size. Rugged module construction withstands vibration and thermal cycling in shop-floor equipment. Designers should apply cycle-by-cycle current limiting and desaturation detection, and mount the module with the specified screw torque to endure thermal cycling without die-attach fatigue over the equipment lifetime.

🏭

Servo Amplifiers

High-power servo amplifiers driving large axis motors use the CM600DY-24T as the inverter power stage, exploiting its 600 A peak capability for rapid acceleration and deceleration torque. The 1200 V class suits 400 V AC servo supply buses with regenerative bus-pump-up margins. The half-bridge structure keeps commutation loop inductance low, preserving current-control bandwidth at high PWM frequencies. Because servo duty includes frequent overload pulses, designers must size the heatsink for the RMS current and confirm the datasheet safe-operating-area covers peak current pulses at the chosen bus voltage. The isolated package allows chassis-mounted cooling compatible with sealed industrial cabinets.

⚡

Induction Heating Power Supplies

Industrial induction heating inverters for forging, heat treatment, and melting employ the CM600DY-24T in full-bridge or half-bridge resonant configurations at 1-30 kHz. The module's 1200 V rating accommodates resonant tank voltage peaks, and its 600 A capability addresses high-current tank circuits typical of medium-frequency melting installations. T-Series low tail-current losses improve efficiency in soft-switching resonant operation. Layout should use coaxial or laminated busbar connections to the resonant capacitor bank, and gate timing must guarantee dead time to prevent shoot-through. The insulated baseplate simplifies integration with water-cooled heatsinks standard in this equipment class.

💡

Renewable Energy Inverters

Central photovoltaic and wind grid-tie inverters in the 100-500 kW class use the CM600DY-24T in the inverter bridge and boost stages, where 1200 V devices pair with 800-1000 V DC bus architectures common in utility-scale solar strings. The 600 A rating permits high per-module power density, and the dual package completes a phase leg with minimal loop inductance. Low conduction and switching losses raise European-weighted efficiency, directly affecting revenue in solar plants. Designers should model thermal cycling from irradiance variation, use PC-TIM or high-quality grease, and apply desat-protected isolated gate drivers to survive grid faults and DC-link short circuits.

What is the voltage and current rating of CM600DY-24T?
The CM600DY-24T is rated 1200 V collector-emitter voltage (VCES) and 600 A collector current in a dual half-bridge configuration. According to Mitsubishi Electric, it is a T-Series standard-type insulated IGBT module for high-power switching use, typically serving one complete inverter leg in 400 V AC class industrial drives.
Where can I buy CM600DY-24T online?
The CM600DY-24T is available through Mouser, which lists inventory and pricing for the Mitsubishi Electric CM600DY-24T, and through distributor networks aggregated on Octopart, where 4 distributors are compared. Pricing on XAIPART is quoted on request due to the unit cost class of high-power modules; request a quote for current pricing as of 2026-10-11.
What is the price of CM600DY-24T?
CM600DY-24T unit pricing is not published as a fixed catalogue price in the verified data; high-power IGBT modules of this class are typically quote-based. Octopart compares bulk pricing from 4 distributors for this part. Contact XAIPART for a quote valid as of 2026-10-11, and compare against Mouser and Octopart listings for the best bulk discount.
What is the difference between CM600DY-24T and CM600DY-24A?
Both are 1200 V, 600 A dual (half-bridge) IGBT modules in the same Mitsubishi-family insulated package. The CM600DY-24A belongs to an earlier/parallel standard series, while the CM600DY-24T is the T-Series standard type; the T-Series offers lower power loss. The Powerex CM600DY-24A is listed at 1200 V, 600 A, 3670 W on DigiKey, confirming the same form-factor class and drop-in intent.
What is the best drop-in replacement for CM600DY-24T?
The closest drop-in replacement is the Mitsubishi Electric CM600DY-24T#330G, which is the same module with pre-applied PC-TIM thermal interface material - identical electrical ratings and footprint. Within the same family, CM600DX-24T and CM600DY-24S share the dual-module footprint per Avaq cross-reference comparisons. Always verify pin/terminal assignment and gate-resistor design against the datasheet before substitution.
Where can I download the CM600DY-24T datasheet PDF?
The official CM600DY-24T datasheet PDF is hosted by Mitsubishi Electric at mitsubishielectric.com in the T-Series IGBT module datasheet section, titled 'IGBT Modules CM600DY-24T HIGH POWER SWITCHING USE INSULATED TYPE'. Mirrors exist at Darrah Electric and Ineltron. Always prefer the manufacturer-hosted PDF as the authoritative source for ratings and characteristic curves.
Is CM600DY-24T suitable for a 400V AC motor drive?
Yes. The 1200 V VCES rating of the CM600DY-24T provides adequate margin for 400 V AC industrial drive DC buses, which typically reach 540-650 V under regeneration and line-swell conditions. The 600 A per-switch rating supports large frame motor drives. Verify junction temperature and switching-loss budgets at your PWM frequency using the datasheet loss curves.
Is CM600DY-24T the same as CM600DY-24S?
No. The CM600DY-24T and CM600DY-24S are both Mitsubishi dual IGBT modules in the same footprint family, but they belong to different technology generations with different switching-loss and saturation-voltage characteristics. Avaq publishes a specification comparison of the two parts; consult it and both datasheets to confirm whether the S-series electrical behavior is acceptable in your T-series design.
What are the key specifications of CM600DY-24T that engineers should know?
Key CM600DY-24T specifications: 1200 V VCES, 600 A collector current, dual half-bridge configuration with integrated freewheeling diodes, insulated chassis-mount package for high-power switching, Mitsubishi T-Series standard type, and a #330G variant with pre-applied PC-TIM. These parameters suit industrial inverters, UPS, and welding supplies on 400 V class AC lines.
What is the Mitsubishi equivalent of CM600DY-24T in the same family?
Within Mitsubishi Electric, the CM600C1Y-24T and CM600DX-24T are same-footprint 1200 V-class dual modules, and the CM600DY-24T#330G is the exact electrical equivalent with PC-TIM pre-applied. The Powerex CM600DY-24A (1200 V, 600 A, 3670 W per DigiKey) is the recognized cross-brand/family alternate widely stocked in North America.
Does CM600DY-24T need a thermal interface material?
The base CM600DY-24T requires externally applied thermal grease or a thermal pad between the module baseplate and heatsink. The CM600DY-24T#330G variant ships with pre-applied PC-TIM (phase-change thermal interface material), which gives more consistent thermal resistance across production units and reduces assembly variability - recommended for volume manufacturing.
How should I mount the CM600DY-24T on a heatsink?
Mount the CM600DY-24T on a flat heatsink with the manufacturer-specified screw torque and sequence, using thermal grease or choosing the #330G PC-TIM variant. Uneven mounting torque or heatsink bowing stresses the internal solder and die attach, a leading cause of power-cycling failures in 600 A class modules. Isolated baseplate construction means no additional isolation pad is required for basic insulation.
What gate drive considerations apply to CM600DY-24T?
Use a dedicated half-bridge gate driver with appropriate dead time for the CM600DY-24T, such as isolated drivers in the UCC21520 or UCC21750 class, and size the gate resistors per the datasheet switching-loss curves. Because the module is a 600 A device, layout inductance in the gate loop and DC bus (use laminated busbar) strongly affects switching behavior and spike susceptibility.
What is the lead time and stock situation for CM600DY-24T?
Stock and lead time for CM600DY-24T vary by distributor; Mouser lists inventory status and Octopart compares availability across 4 distributors. High-power IGBT modules frequently carry multi-week lead times when allocated. XAIPART confirms availability by quote as of 2026-10-11; the CM600DY-24T#330G variant is a commonly stocked alternative if grease application in-house is acceptable.

Données de référence d'ingénierie pour CM600DY-24T — comparaison, recommandations de conception et informations de conformité.

Guide de sélection

Choose the CM600DY-24T when you need a proven 1200 V, 600 A dual half-bridge module for a 400 V class industrial drive, UPS, welding supply, or solar inverter, and want T-Series efficiency at standard-type pricing. Select the CM600DY-24T#330G for identical electricals with factory PC-TIM, ideal for volume production consistency. Choose the CM600DX-24T if your efficiency targets justify the newer X-Series technology in the same footprint. The CM600DY-24S and CM600DY-24A are legacy-generation options - prefer them only for form-fit-function replacement in existing S/A-series designs, accepting higher losses. Verify terminal assignment and gate characteristics against both datasheets before any substitution, since family members share the footprint but not identical switching behavior.

Comparaison avec les alternatives

Paramètre Ce produit CM600DY-24T#330G CM600DX-24T CM600DY-24S CM600DY-24A
Package Insulated chassis-mount module Same package with PC-TIM pre-applied Same dual module footprint Same dual module footprint Same dual module footprint
Brand Mitsubishi Electric Mitsubishi Electric Mitsubishi Electric Mitsubishi Electric Mitsubishi Electric / Powerex
VCES 1200 V 1200 V 1200 V 1200 V 1200 V
IC (Continuous) 600 A 600 A 600 A 600 A 600 A
Technology Generation T-Series (7th Generation standard type per MEUS) T-Series (same die) X-Series (newer) S-Series (older) A-Series (older)
Thermal Interface User-applied grease PC-TIM pre-applied User-applied User-applied User-applied
Configuration Dual (Half-Bridge) Dual (Half-Bridge) Dual (Half-Bridge) Dual (Half-Bridge) Dual (Half-Bridge)
Relative Power Loss Low (T-Series) Same as CM600DY-24T Lower (X-Series) Higher (older generation) Higher (older generation)

Principaux différenciateurs

  • Newest standard-type generation in the CM600DY-24x family (vs CM600DY-24A)
  • PC-TIM factory-applied variant available (vs CM600DX-24T)
  • Trade-off: not the lowest-loss generation (vs CM600DX-24T)

Notes de conception

Thermal management is the primary reliability lever for the CM600DY-24T. Estimated: a 300 A RMS half-bridge load with a typical T-Series VCE(sat) near 2 V gives roughly 600 W conduction loss plus switching losses; with a junction-to-case thermal resistance on the order of tenths of a C/W per the datasheet, heatsink selection dominates junction temperature. Use the official datasheet loss curves for your exact bus voltage, PWM frequency, and modulation, and consider the CM600DY-24T#330G PC-TIM variant to remove grease-application variability in production.

Keep the DC bus loop (DC+ to DC- through the half bridge) as low-inductance as possible using laminated busbars directly bolted to the module terminals. At 600 A turn-off, even tens of nanohenries of stray inductance produce significant VCE overshoot that erodes the 1200 V margin. Place snubber or DC-link film capacitors at the module terminals, and route gate drive traces twisted-pair or coaxial with independent emitter (Kelvin) returns per the module auxiliary terminals.

Apply the manufacturer-specified mounting screw torque in the datasheet sequence; uneven torque bows the baseplate, creating hot spots and accelerating solder fatigue under power cycling. Do not exceed the datasheet VGES limit on the gate, and never operate without the specified dead time - shoot-through at 600 A destroys modules within microseconds. Verify short-circuit withstand time in the datasheet and pair the module with a desat-protected gate driver such as the UCC21750.

Informations de conformité

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Sans plomb
Unknown
Sans halogène
Unknown
Minerais de conflit
Unknown

Compliance status not stated in verified web data; consult the official Mitsubishi Electric product page or datasheet for RoHS/REACH declarations.

Données vérifiées le : 2026-10-11 — données vérifiées et sélectionnées par l'équipe d'ingénierie composants de XAIPART

Recherches associées

CM600DY-24T CM600DY-24T datasheet PDF Mitsubishi Electric CM600DY-24T IGBT module 1200V 600A dual IGBT module CM600DY-24T equivalent replacement CM600DY-24T vs CM600DY-24A CM600DY-24T price buy CM600DY-24T motor drive inverter module CM600DY-24T#330G PC-TIM IGBT module what is the rating of CM600DY-24T CM600DY-24T pinout terminal connection half bridge IGBT module 400V AC drive

Composants & termes associés

Mitsubishi Electric CM600DY-24T CM600DY-24T#330G CM600DX-24T CM600DY-24S CM600DY-24A CM600C1Y-24T Powerex IGBT module insulated-gate bipolar transistor T-Series half-bridge topology 1200 V 600 A PC-TIM VCE(sat) freewheeling diode industrial motor drive UPS inverter welding power supply laminated busbar chassis-mount insulated package VCMOSFET gate driver UCC21750 RoHS
RFQ de devis rapide
Renseignez tous les détails — notre équipe commerciale vous répondra sous 24 heures
Référence Fabricant Boîtier QTY Prix cible Total
Total : 0,00 USD
✓
Devis envoyé !

Nous répondrons à votre e-mail sous 24 heures

1
RFQ envoyée
2
Devis reçu
3
Commande passée
4
Paiement
5
Expédié
6
Livré
Voir les détails de la RFQ