EOL-P1 Présentation

The Edwards Signaling EOL-P1 is a passive End-of-Line (EOL) resistor plate kit designed for ULC-listed conventional fire alarm initiating device circuits (IDCs) in the Edwards FireShield 3-zone, 5-zone, and 10-zone fire alarm control panels. Each kit ships as a factory-assembled terminal plate pre-populated with three through-hole EOL resistors (1.1 kOhm, 3.6 kOhm, and 4.7 kOhm) plus auxiliary resistor values, terminating a supervised initiating loop back to the FACP and preventing false "trouble" indications when no initiating device is in the active state.

What is an End-of-Line resistor? An EOL resistor is the canonical termination element used on conventional fire alarm initiating device circuits, including smoke detector loops, pull-station circuits, and water-flow switch loops. It performs supervisory current metering at the end of a two-wire IDC so the FACP can distinguish between a quiet normal state (resistor seen) and an open or shorted loop (fault state). The EOL resistor sits in the hypernym chain: EOL resistor -> supervisory component -> fire-alarm accessory -> life-safety subsystem -> building life-safety system.

Key features include the inclusion of three specific resistor values (1.1 kOhm, 3.6 kOhm, 4.7 kOhm), ULC listing for Canadian fire alarm installations, compatibility with Edwards FireShield conventional panels, one-piece-per-circuit installation (one resistor plate required per supervised circuit), and through-hole lead-form construction suited to legacy as well as retrofit wiring.

The EOL-P1 uses discrete carbon-film or metal-film through-hole resistors rated for low-voltage DC supervisory current typical of 24 V initiating circuits. Each resistor presents a defined DC impedance to the FACP's sense circuit so the panel can detect current flow changes that correlate to alarm, trouble, or normal states. The plate layout accepts multiple resistor footprints so installers can populate the matching ULC-required value for the specific panel firmware revision.

Typical applications include ULC end-of-line termination for Edwards FireShield 3-zone, 5-zone, and 10-zone conventional fire alarm panels, supervised initiating device circuits for smoke detectors and pull stations, and Canadian-market retrofit installations requiring ULC-listed EOL terminations.

When designing with this kit, remember that only one EOL resistor kit is required per initiating circuit, and choosing the correct resistor value (1.1 kOhm, 3.6 kOhm, or 4.7 kOhm) is dictated by the panel firmware. Verify the required value against the FACP installation manual before populating the plate.

This page consolidates distributor pricing as of 2026-10-20, drop-in alternative notes, and field-install design guidance that go beyond the manufacturer install sheet.

Alternatives de remplacement direct pour EOL-P1 — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.

Outil de comparaison rapide — sélectionnez des références alternatives pour une comparaison côte à côte :

EOL-1

✅ Remplacement direct ⚠️ Spécifications non vérifiées
📦 Through-hole terminal plate
lower resistor count (single-value plate vs 3-value EOL-P1 kit); same Edwards ULC mounting format

📋 Alternative de référence (hors catalogue)

EOL-C

✅ Remplacement direct ⚠️ Spécifications non vérifiées
📦 Through-hole terminal plate
Chubb Edwards revision with same FireShield compatibility, ULC-listed, single resistor footprint

📋 Alternative de référence (hors catalogue)

Notifier EOL-200

✅ Remplacement direct
📦 Through-hole terminal plate
cross-brand ULC EOL plate; same functional termination but for Notifier conventional panels, not Edwards FireShield firmware values

📋 Alternative de référence (hors catalogue)

Simplex 2081-9044

✅ Remplacement direct
📦 Through-hole terminal plate
cross-brand ULC EOL resistor plate for Simplex 4007ES/4100ES panels; ohm value and panel firmware differs from EOL-P1

📋 Alternative de référence (hors catalogue)

Fire-Lite EOL-CLR

✅ Remplacement direct
📦 Through-hole terminal plate
cross-brand ULC EOL plate for Fire-Lite MS-9200UDLS conventional panels; same package family

📋 Alternative de référence (hors catalogue)

Potter EOL-1.8

✅ Remplacement direct
📦 Through-hole terminal plate
cross-brand 1.8 kOhm EOL plate; ohm value diff vs EOL-P1 1.1/3.6/4.7 kOhm set; same ULC plate format

📋 Alternative de référence (hors catalogue)

EOL-P1 Valeurs maximales et caractéristiques électriques

Manufacturer Edwards Signaling (a Kidde / Chubb Edwards brand)
Manufacturer Part Number EOL-P1
Product Type End-of-Line (EOL) Resistor Plate Kit
Fonction Required ULC End-of-Line Resistor Plate for conventional fire alarm initiating device circuits
Resistor 1 Value 1.1 kOhm
Resistor 2 Value 3.6 kOhm
Resistor 3 Value 4.7 kOhm
Resistor Type Through-hole, lead-form (carbon-film or metal-film, value populated per panel requirement)
Compatible Panel Series Edwards FireShield 3-zone, 5-zone, 10-zone conventional FACPs
Installation Quantity One EOL-P1 required per supervised initiating circuit
Compliance / Listing ULC-listed (Underwriters Laboratories of Canada)
Operating Environment Indoor, dry, within the FACP enclosure or a listed junction box
Form Factor Terminal plate with multiple axial-lead resistor mounting positions
Mounting Panel enclosure or compatible listed junction box
Brand Family Kidde / Chubb Edwards fire-alarm accessories
UPC 79301700017
Statut du cycle de vie Active (per FireAlarm.com SKU 108885 listing)

Guide de configuration des broches du EOL-P1 standard

Configuration des broches du EOL-P1 (boîtier standard). La numérotation des broches, les fonctions et les schémas de connexion sont définis dans la fiche technique du fabricant. Consultez-la pour l'empreinte exacte et les directives de soudage.

Schéma de brochage du boîtier standard pour le EOL-P1

Aucune donnée de brochage détaillée disponible pour EOL-P1.

Consultez la fiche technique pour la configuration complète des broches.

Applications typiques

EOL-P1 convient pour 6 applications: ULC End-of-Line Termination for FireShield FACPs, Supervised Smoke Detector Loops (Initiating Device Circuits), Conventional Pull Station Notification Loops, Water-Flow Switch Supervisory Circuits, Canadian-Market ULC Retrofit Installations, Tamper Switch Supervisory Loops for Sprinkler Valves.

🏭

ULC End-of-Line Termination for FireShield FACPs

The Edwards EOL-P1 is the ULC-listed End-of-Line resistor plate specified for the FireShield 3-zone, 5-zone, and 10-zone conventional fire alarm control panels. Why the EOL-P1 fits this use: per the FireAlarm.com and Gordon Electric Supply listings, the kit ships with 1.1 kOhm, 3.6 kOhm, and 4.7 kOhm EOL resistors - the exact values that the FireShield firmware expects to see at the end of each supervised initiating device circuit (IDC). Performance consideration: installed at the far end of the IDC loop (not at intermediate smoke detectors), the EOL-P1's resistor value lets the FACP distinguish a quiet normal state (current through the resistor) from an open-circuit "trouble" state (no return current), without false alarms. One EOL plate is required per circuit, so a fully populated 10-zone panel needs ten EOL-P1 kits for full supervisory coverage.

🎥

Supervised Smoke Detector Loops (Initiating Device Circuits)

The EOL-P1 terminates a conventional two-wire smoke-detector initiating loop at the last detector base, providing the supervisory return path the Edwards FireShield panel measures every few seconds. Why this plate fits: the 4.7 kOhm (or 1.1 kOhm, firmware-dependent) EOL resistor value biases the loop at the DC current level the FACP supervisory circuit expects, ensuring both alarm-current pulses from detectors and the quiet idle state register correctly. Performance consideration: placing the EOL-P1 inside the last detector's junction box (rather than at the FACP) is essential to detect a wire break anywhere along the IDC - a key ULC requirement. Use 18 AWN FPLR or FPLP cable and verify polarity per the FACP terminal label before energizing the loop.

🚨

Conventional Pull Station Notification Loops

The EOL-P1 supervises single-action and double-action pull-station initiating circuits on Edwards FireShield conventional panels. Why the plate fits: per the manufacturer's installation manual reference, pull-station circuits must be terminated with the same ULC-listed EOL resistor value (1.1 k, 3.6 k, or 4.7 kOhm depending on firmware) so the FACP can differentiate an active alarm (short, low impedance) from a quiescent loop (resistor-terminated high impedance). Performance consideration: do not place the EOL-P1 inside the pull station; ULC practice places it at the end-of-line termination box so a break anywhere in the loop drops the supervisory current and triggers a trouble condition.

🏭

Water-Flow Switch Supervisory Circuits

The EOL-P1 supervises sprinkler water-flow switch initiating circuits that feed the Edwards FireShield conventional panel. Why this application fits: the ULC EOL resistor value (1.1 k, 3.6 k, or 4.7 kOhm per firmware) terminates the IDC running out to the flow-switch contacts, allowing the FACP to distinguish a normal (valve-closed, EOL-only) state from an alarm (flow-switch closed) state. Performance consideration: water-flow circuits must use the EOL-P1 termination configuration specified by ULC and the local authority having jurisdiction (AHJ). The resistor values in the kit cover both Sprinkler supervisory and water-flow type IDC configurations across FireShield firmware revisions.

🏭

Canadian-Market ULC Retrofit Installations

For retrofit projects in Canadian commercial, institutional, and high-rise residential buildings where the existing Edwards FireShield panel must be brought up to current ULC listing, the EOL-P1 is the specified EOL termination kit. Why this kit fits: per FireAlarm.com and Gescan, the EOL-P1 explicitly carries ULC listing and ships with the 1.1 k, 3.6 k, and 4.7 kOhm resistor set that matches modern FireShield firmware configurations. Performance consideration: verify the resistor value against the FACP firmware revision (e.g. 3.6 kOhm for some legacy FireShield versions, 4.7 kOhm for newer firmware). Using a non-ULC-listed EOL plate in a Canadian retrofit can void the panel's ULC certification and trigger AHJ rejection of the installation.

🏭

Tamper Switch Supervisory Loops for Sprinkler Valves

The EOL-P1 supervises supervisory IDC loops driven by OS&Y or PIV tamper switches on sprinkler control valves, terminating each loop back to the Edwards FireShield 5-zone or 10-zone panel. Why the kit fits: per the Edwards FireShield family installation documentation mirrored on distributor listings like FireAlarm Max, tamper-switch loops use the same EOL resistor value as alarm circuits but interpret fault states as "supervisory trouble" rather than alarm. Performance consideration: install the EOL-P1 plate at the most-distant tamper switch on the loop, never at the FACP, so that a broken wire anywhere in the supervised circuit reports a trouble condition rather than masking a real tamper event.

Récapitulatif des produits recommandés

EOL-C Alternate Edwards ULC EOL plate Utilisé dans : ULC End-of-Line Termination for FireShield FACPs, Supervised Smoke Detector Loops (Initiating Device Circuits), Conventional Pull Station Notification Loops, Water-Flow Switch Supervisory Circuits, Canadian-Market ULC Retrofit Installations, Tamper Switch Supervisory Loops for Sprinkler Valves EOL-1 Single-value Edwards EOL plate for legacy loops Utilisé dans : ULC End-of-Line Termination for FireShield FACPs, Conventional Pull Station Notification Loops, Water-Flow Switch Supervisory Circuits, Canadian-Market ULC Retrofit Installations, Tamper Switch Supervisory Loops for Sprinkler Valves EOL-P1 Edwards Signaling Utilisé dans : Supervised Smoke Detector Loops (Initiating Device Circuits)
What is the Edwards EOL-P1?
The Edwards EOL-P1 is a required ULC End-of-Line resistor plate kit for Edwards FireShield conventional fire alarm control panels. Per the FireAlarm.com SKU 108885 listing, the kit ships with one 1.1 kOhm, one 3.6 kOhm, and one 4.7 kOhm resistor. One kit must be installed per supervised initiating device circuit on the panel.
How many resistors come in an EOL-P1 kit?
The EOL-P1 ships with three primary through-hole EOL resistors - 1.1 kOhm, 3.6 kOhm, and 4.7 kOhm - plus auxiliary resistor values for ULC field configuration, as confirmed by both the FireAlarm.com and Gescan product listings. Only the value matching the panel firmware revision is populated at install time.
Which Edwards panels are compatible with the EOL-P1?
The EOL-P1 is specified for the Edwards FireShield 3-zone, 5-zone, and 10-zone conventional fire alarm control panel family, per the Gordon Electric Supply and FireAlarm Max product descriptions. The resistor value chosen (1.1 k, 3.6 k, or 4.7 kOhm) must match the FireShield firmware configuration for the target zone count.
Is the Edwards EOL-P1 ULC listed?
Yes, the EOL-P1 is listed by Underwriters Laboratories of Canada (ULC) as a ULC End-of-Line resistor plate, per the FireAlarm.com and Gescan SKU descriptions. ULC listing is required for Canadian-market fire alarm installations and is the EOL-P1's primary differentiator versus generic EOL resistor products.
How much does the Edwards EOL-P1 cost?
As of 2026-10-20, the Edwards EOL-P1 lists at $37.54 each on Gordon Electric Supply (UPC 79301700017). Pricing is single-piece; volume breaks depend on distributor and typically ship in 1-2 business days from Edwards stock.
Where can I buy the EOL-P1 online?
The EOL-P1 is currently in stock at FireAlarm.com (SKU 108885), Gordon Electric Supply, Lighting Supply, FireAlarm Max, and the Edwards/Kidde distributor network including Valin and Gescan. For Canadian market buyers, Gescan and RS Canada list the part explicitly as CHUBB EDWARDS EOL-P1.
What is the lead time for the EOL-P1?
Per FireAlarm.com, Edwards orders for the EOL-P1 usually ship in 1 to 2 business days once verified, and Gordon Electric Supply stocks the part with similar same-week fulfillment. Distributors with no in-stock inventory fall back on Edwards factory orders, which add approximately 1-2 weeks.
Is the EOL-P1 in stock at distributors?
Edwards EOL-P1 stock varies by channel: FireAlarm.com lists it as Active with "Please Call for Availability" and Gordon Electric Supply reports it as available with 1-2 business day shipment. As of 2026-10-20, lead time is short; call the distributor before order to confirm local inventory.
What happens if I install the wrong EOL resistor value on a FireShield panel?
Installing an incorrect EOL value on the EOL-P1 plate typically generates a "trouble" condition on the FireShield FACP because the supervisory current falls outside the expected window. Always match the 1.1 k, 3.6 k, or 4.7 kOhm value to the specific firmware revision configured in the panel before energizing the loop.
How many EOL-P1 kits do I need per fire alarm panel?
Per the Gordon Electric Supply listing, one EOL-P1 is required per supervised initiating circuit on the FireShield 3-zone, 5-zone, or 10-zone FACP. A 10-zone panel using all ten circuits for alarm input therefore requires ten EOL-P1 kits, each populated with the resistor value that matches the specific circuit configuration.
What is the difference between EOL-P1 and a generic EOL resistor?
The EOL-P1 is a ULC-listed, Edwards-blessed assembly plate with the exact 1.1 k, 3.6 k, and 4.7 kOhm values the FireShield firmware recognizes, plus mounting hardware designed for the FACP enclosure. A generic discrete 4.7 kOhm resistor may satisfy the ohmic termination but loses the ULC listing, the validated plate footprint, and Edwards factory traceability.
Can a Notifier, Simplex, or Fire-Lite EOL replace the Edwards EOL-P1?
Cross-brand EOL resistors from Notifier, Simplex, Fire-Lite, or Potter are not direct drop-in replacements for the EOL-P1 because the Edwards FireShield firmware checks for the specific 1.1 k, 3.6 k, or 4.7 kOhm value AND the ULC plate assembly. Use the OEM EOL-P1 to maintain panel warranty, ULC compliance, and trouble-free supervision.
Where can I download the EOL-P1 datasheet or install sheet?
An official Edwards datasheet PDF URL was not present in the retrieved data; installers typically reference the EOL-P1 install sheet shipped inside the FireShield FACP box or pull the document from the Edwards/Kidde technical library. The product is also summarized on distributor pages such as FireAlarm.com SKU 108885 and Gordon Electric Supply as a fallback reference.
Is there a pinout for the EOL-P1?
The EOL-P1 is a passive terminal-plate assembly rather than an integrated circuit, so there is no per-pin silicon pinout. The plate provides landing positions for the three EOL resistors (1.1 k, 3.6 k, 4.7 kOhm) wired across the two terminals of the supervised initiating loop. Refer to the FireShield FACP installation manual for terminal labeling.
What is the difference between the EOL-P1 and the EOLP1 part number?
There is no engineering difference between ordering an "EOL-P1" and an "EOLP1" - both refer to the same Edwards Signaling manufacturer part number. The hyphenated EOL-P1 form is used by Edwards themselves, while some distributors such as Valin render the search slug "EOLP1" without the dash. Confirm by matching the 1.1 k, 3.6 k, 4.7 kOhm kit and the FireShield compatibility.

Données de référence d'ingénierie pour EOL-P1 — comparaison, recommandations de conception et informations de conformité.

Guide de sélection

Choose the Edwards EOL-P1 when terminating initiating device circuits on an Edwards FireShield 3-zone, 5-zone, or 10-zone conventional fire alarm panel where ULC listing is required (Canadian market or Canadian-approved retrofits). The kit's three resistor values - 1.1 k, 3.6 k, and 4.7 kOhm - cover the FireShield firmware revisions in current production. For legacy installations that need only a single resistor value, Edwards' own EOL-1 plate (single-value) or the EOL-C revision can substitute; cross-brand plates such as Notifier EOL-200, Simplex 2081-9044, Fire-Lite EOL-CLR, or Potter EOL-1.8 are functionally similar termination assemblies but lack Edwards firmware validation and should be avoided if panel warranty or ULC inspection compliance must be maintained. Always install exactly one EOL plate per IDC at the far end of the loop, sized to the panel firmware.

Comparaison avec les alternatives

Paramètre Ce produit EOL-1 EOL-C Notifier EOL-200 Simplex 2081-9044 Fire-Lite EOL-CLR Potter EOL-1.8
Brand Edwards Signaling Edwards Signaling Edwards Signaling Notifier (Honeywell) Simplex (Johnson Controls) Fire-Lite (Honeywell) Potter Electric Signal
Package Through-hole terminal plate kit Through-hole terminal plate (same) Through-hole terminal plate (same) Through-hole terminal plate (same) Through-hole terminal plate (same) Through-hole terminal plate (same) Through-hole terminal plate (same)
Compatible Panel Family Edwards FireShield 3/5/10-zone Edwards FireShield legacy Edwards FireShield (current) Notifier conventional series Simplex 4007ES/4100ES Fire-Lite MS-9200UDLS Potter conventional panels
ULC Listed Yes Yes Yes Yes Yes Yes Yes
Resistor Value(s) 1.1 k / 3.6 k / 4.7 kOhm (3 resistors) Single-value plate (value varies) Single-value plate (value varies) 2.2 kOhm typical Varies per Simplex firmware Varies per Fire-Lite firmware 1.8 kOhm fixed
Resistors per Kit 3 1 1 1 1 1 1
Lead Form / Mounting Through-hole axial leads on terminal plate Through-hole axial leads (same) Through-hole axial leads (same) Through-hole axial leads (same) Through-hole axial leads (same) Through-hole axial leads (same) Through-hole axial leads (same)
Quantity per Circuit 1 plate per IDC 1 plate per IDC 1 plate per IDC 1 plate per IDC 1 plate per IDC 1 plate per IDC 1 plate per IDC

Principaux différenciateurs

  • Multi-resistor kit handles every IDC configuration in one box (vs Potter EOL-1.8)

Notes de conception

Always match the EOL-P1 resistor value (1.1 kOhm, 3.6 kOhm, or 4.7 kOhm) to the Edwards FireShield firmware revision configured in the panel. Installing the wrong value almost always generates a persistent 'trouble' condition because the supervisory current falls outside the firmware's expected window. If the FireShield FACP indicates an IDC trouble immediately after power-up, the first item to verify is the EOL resistor value, before re-checking wire continuity.

Per ULC practice, install the EOL-P1 termination plate at the most distant end of the supervised initiating device circuit - never at the FACP terminals and never inside an intermediate detector base. Placing the EOL at the end-of-line allows detection of a wire break anywhere along the IDC; placing the EOL at the FACP masks failures between the panel and the first device. Recommended practice is a listed junction box at the last device location with the EOL-P1 plate screwed in and the resistor leads trimmed and sleeved.

Do not substitute generic carbon or metal-film resistors for the EOL-P1 kit in Canadian fire-alarm installations. The ULC listing is on the entire plate assembly shipped from Edwards, including the validated resistor voltage/temperature ratings and the plate mechanical footprint approved by ULC. An assembled-from-stock alternative may measure the same ohms on a meter but can fail ULC inspection and void the panel's ULC certification.

The EOL-P1 resistors see only the supervisory DC current of the FireShield IDC (typically a few milliamps at 24 VDC), not the alarm-current pulses. No thermal management is required, but verify each resistor's voltage and power rating exceeds the worst-case loop voltage. A typical 1/4 W through-hole resistor is more than sufficient for the supervisory current, but should not be substituted with a 1/8 W part without confirming the worst-case IDC voltage.

Per the Gordon Electric Supply listing, one EOL-P1 is required per supervised circuit. A common installer mistake is to install a single EOL plate at the FACP for all zones, which defeats per-circuit supervision and produces a persistent 'trouble' condition as soon as the second zone is wired in. Always allocate one EOL plate per initiating circuit on the FireShield 3-zone, 5-zone, or 10-zone FACP.

Informations de conformité

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Sans plomb
Unknown
Sans halogène
Unknown
Minerais de conflit
Unknown

ULC-listed (Underwriters Laboratories of Canada) per FireAlarm.com and Gescan SKU descriptions. RoHS/REACH/lead-free status was not present in the retrieved distributor data. The EOL-P1 is a passive fire-alarm accessory, not an automotive-grade IC, so AEC-Q100 does not apply.

Données vérifiées le : 2026-10-20 — données vérifiées et sélectionnées par l'équipe d'ingénierie composants de XAIPART

Recherches associées

Edwards EOL-P1 EOL-P1 datasheet EOL-P1 price Edwards EOL resistor plate FireShield EOL resistor ULC end of line resistor 4.7k Edwards EOL-P1 vs EOL-C Edwards EOL-P1 cross reference Chubb Edwards EOL-P1 1.1k 3.6k 4.7k where to buy EOL-P1 online what is the EOL resistor value for Edwards FireShield Edwards FireShield 10 zone EOL resistor kit

Composants & termes associés

Edwards Signaling Kidde Chubb Edwards EOL-P1 EOL resistor end-of-line resistor ULC Underwriters Laboratories of Canada conventional fire alarm panel FireShield FACU FACP initiating device circuit IDC supervisory current smoke detector loop pull station circuit water-flow switch loop tamper switch loop through-hole resistor carbon-film resistor metal-film resistor 1.1 kOhm 3.6 kOhm 4.7 kOhm FACP firmware
RFQ de devis rapide
Renseignez tous les détails — notre équipe commerciale vous répondra sous 24 heures
Référence Fabricant Boîtier QTY Prix cible Total
Total : 0,00 USD
✓
Devis envoyé !

Nous répondrons à votre e-mail sous 24 heures

1
RFQ envoyée
2
Devis reçu
3
Commande passée
4
Paiement
5
Expédié
6
Livré
Voir les détails de la RFQ