EOL-P1 - Edwards EOL Resistor Plate Kit for Fire Alarm | Edwards Signaling
Référence : EOL-P1 ✓ Actif| Qté | Prix unitaire | Total |
|---|---|---|
| 1 | $37.54 | $37,54 |
| 5 | $35.66 | $178,30 |
| 10 | $33.78 | $337,80 |
| 25 | $31.9 | $797,50 |
| 50 | $30.02 | $1 501,00 |
EOL-P1 Présentation
What is an End-of-Line resistor? An EOL resistor is the canonical termination element used on conventional fire alarm initiating device circuits, including smoke detector loops, pull-station circuits, and water-flow switch loops. It performs supervisory current metering at the end of a two-wire IDC so the FACP can distinguish between a quiet normal state (resistor seen) and an open or shorted loop (fault state). The EOL resistor sits in the hypernym chain: EOL resistor -> supervisory component -> fire-alarm accessory -> life-safety subsystem -> building life-safety system.
Key features include the inclusion of three specific resistor values (1.1 kOhm, 3.6 kOhm, 4.7 kOhm), ULC listing for Canadian fire alarm installations, compatibility with Edwards FireShield conventional panels, one-piece-per-circuit installation (one resistor plate required per supervised circuit), and through-hole lead-form construction suited to legacy as well as retrofit wiring.
The EOL-P1 uses discrete carbon-film or metal-film through-hole resistors rated for low-voltage DC supervisory current typical of 24 V initiating circuits. Each resistor presents a defined DC impedance to the FACP's sense circuit so the panel can detect current flow changes that correlate to alarm, trouble, or normal states. The plate layout accepts multiple resistor footprints so installers can populate the matching ULC-required value for the specific panel firmware revision.
Typical applications include ULC end-of-line termination for Edwards FireShield 3-zone, 5-zone, and 10-zone conventional fire alarm panels, supervised initiating device circuits for smoke detectors and pull stations, and Canadian-market retrofit installations requiring ULC-listed EOL terminations.
When designing with this kit, remember that only one EOL resistor kit is required per initiating circuit, and choosing the correct resistor value (1.1 kOhm, 3.6 kOhm, or 4.7 kOhm) is dictated by the panel firmware. Verify the required value against the FACP installation manual before populating the plate.
This page consolidates distributor pricing as of 2026-10-20, drop-in alternative notes, and field-install design guidance that go beyond the manufacturer install sheet.
Alternatives de remplacement direct pour EOL-P1 — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.
Outil de comparaison rapide — sélectionnez des références alternatives pour une comparaison côte à côte :
EOL-1
✅ Remplacement direct ⚠️ Spécifications non vérifiées📋 Alternative de référence (hors catalogue)
EOL-C
✅ Remplacement direct ⚠️ Spécifications non vérifiées📋 Alternative de référence (hors catalogue)
Notifier EOL-200
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
Simplex 2081-9044
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
Fire-Lite EOL-CLR
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
Potter EOL-1.8
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
EOL-P1 Valeurs maximales et caractéristiques électriques
| Manufacturer | Edwards Signaling (a Kidde / Chubb Edwards brand) |
| Manufacturer Part Number | EOL-P1 |
| Product Type | End-of-Line (EOL) Resistor Plate Kit |
| Fonction | Required ULC End-of-Line Resistor Plate for conventional fire alarm initiating device circuits |
| Resistor 1 Value | 1.1 kOhm |
| Resistor 2 Value | 3.6 kOhm |
| Resistor 3 Value | 4.7 kOhm |
| Resistor Type | Through-hole, lead-form (carbon-film or metal-film, value populated per panel requirement) |
| Compatible Panel Series | Edwards FireShield 3-zone, 5-zone, 10-zone conventional FACPs |
| Installation Quantity | One EOL-P1 required per supervised initiating circuit |
| Compliance / Listing | ULC-listed (Underwriters Laboratories of Canada) |
| Operating Environment | Indoor, dry, within the FACP enclosure or a listed junction box |
| Form Factor | Terminal plate with multiple axial-lead resistor mounting positions |
| Mounting | Panel enclosure or compatible listed junction box |
| Brand Family | Kidde / Chubb Edwards fire-alarm accessories |
| UPC | 79301700017 |
| Statut du cycle de vie | Active (per FireAlarm.com SKU 108885 listing) |
Guide de configuration des broches du EOL-P1 standard
Configuration des broches du EOL-P1 (boîtier standard). La numérotation des broches, les fonctions et les schémas de connexion sont définis dans la fiche technique du fabricant. Consultez-la pour l'empreinte exacte et les directives de soudage.
Aucune donnée de brochage détaillée disponible pour EOL-P1.
Consultez la fiche technique pour la configuration complète des broches.
Applications typiques
EOL-P1 convient pour 6 applications: ULC End-of-Line Termination for FireShield FACPs, Supervised Smoke Detector Loops (Initiating Device Circuits), Conventional Pull Station Notification Loops, Water-Flow Switch Supervisory Circuits, Canadian-Market ULC Retrofit Installations, Tamper Switch Supervisory Loops for Sprinkler Valves.
ULC End-of-Line Termination for FireShield FACPs
The Edwards EOL-P1 is the ULC-listed End-of-Line resistor plate specified for the FireShield 3-zone, 5-zone, and 10-zone conventional fire alarm control panels. Why the EOL-P1 fits this use: per the FireAlarm.com and Gordon Electric Supply listings, the kit ships with 1.1 kOhm, 3.6 kOhm, and 4.7 kOhm EOL resistors - the exact values that the FireShield firmware expects to see at the end of each supervised initiating device circuit (IDC). Performance consideration: installed at the far end of the IDC loop (not at intermediate smoke detectors), the EOL-P1's resistor value lets the FACP distinguish a quiet normal state (current through the resistor) from an open-circuit "trouble" state (no return current), without false alarms. One EOL plate is required per circuit, so a fully populated 10-zone panel needs ten EOL-P1 kits for full supervisory coverage.
Recommandé
Supervised Smoke Detector Loops (Initiating Device Circuits)
The EOL-P1 terminates a conventional two-wire smoke-detector initiating loop at the last detector base, providing the supervisory return path the Edwards FireShield panel measures every few seconds. Why this plate fits: the 4.7 kOhm (or 1.1 kOhm, firmware-dependent) EOL resistor value biases the loop at the DC current level the FACP supervisory circuit expects, ensuring both alarm-current pulses from detectors and the quiet idle state register correctly. Performance consideration: placing the EOL-P1 inside the last detector's junction box (rather than at the FACP) is essential to detect a wire break anywhere along the IDC - a key ULC requirement. Use 18 AWN FPLR or FPLP cable and verify polarity per the FACP terminal label before energizing the loop.
Recommandé
Conventional Pull Station Notification Loops
The EOL-P1 supervises single-action and double-action pull-station initiating circuits on Edwards FireShield conventional panels. Why the plate fits: per the manufacturer's installation manual reference, pull-station circuits must be terminated with the same ULC-listed EOL resistor value (1.1 k, 3.6 k, or 4.7 kOhm depending on firmware) so the FACP can differentiate an active alarm (short, low impedance) from a quiescent loop (resistor-terminated high impedance). Performance consideration: do not place the EOL-P1 inside the pull station; ULC practice places it at the end-of-line termination box so a break anywhere in the loop drops the supervisory current and triggers a trouble condition.
Recommandé
Water-Flow Switch Supervisory Circuits
The EOL-P1 supervises sprinkler water-flow switch initiating circuits that feed the Edwards FireShield conventional panel. Why this application fits: the ULC EOL resistor value (1.1 k, 3.6 k, or 4.7 kOhm per firmware) terminates the IDC running out to the flow-switch contacts, allowing the FACP to distinguish a normal (valve-closed, EOL-only) state from an alarm (flow-switch closed) state. Performance consideration: water-flow circuits must use the EOL-P1 termination configuration specified by ULC and the local authority having jurisdiction (AHJ). The resistor values in the kit cover both Sprinkler supervisory and water-flow type IDC configurations across FireShield firmware revisions.
Recommandé
Canadian-Market ULC Retrofit Installations
For retrofit projects in Canadian commercial, institutional, and high-rise residential buildings where the existing Edwards FireShield panel must be brought up to current ULC listing, the EOL-P1 is the specified EOL termination kit. Why this kit fits: per FireAlarm.com and Gescan, the EOL-P1 explicitly carries ULC listing and ships with the 1.1 k, 3.6 k, and 4.7 kOhm resistor set that matches modern FireShield firmware configurations. Performance consideration: verify the resistor value against the FACP firmware revision (e.g. 3.6 kOhm for some legacy FireShield versions, 4.7 kOhm for newer firmware). Using a non-ULC-listed EOL plate in a Canadian retrofit can void the panel's ULC certification and trigger AHJ rejection of the installation.
Recommandé
Tamper Switch Supervisory Loops for Sprinkler Valves
The EOL-P1 supervises supervisory IDC loops driven by OS&Y or PIV tamper switches on sprinkler control valves, terminating each loop back to the Edwards FireShield 5-zone or 10-zone panel. Why the kit fits: per the Edwards FireShield family installation documentation mirrored on distributor listings like FireAlarm Max, tamper-switch loops use the same EOL resistor value as alarm circuits but interpret fault states as "supervisory trouble" rather than alarm. Performance consideration: install the EOL-P1 plate at the most-distant tamper switch on the loop, never at the FACP, so that a broken wire anywhere in the supervised circuit reports a trouble condition rather than masking a real tamper event.
Recommandé
Récapitulatif des produits recommandés
Données de référence d'ingénierie pour EOL-P1 — comparaison, recommandations de conception et informations de conformité.
Guide de sélection
Comparaison avec les alternatives
| Paramètre | Ce produit | EOL-1 | EOL-C | Notifier EOL-200 | Simplex 2081-9044 | Fire-Lite EOL-CLR | Potter EOL-1.8 |
|---|---|---|---|---|---|---|---|
| Brand | Edwards Signaling | Edwards Signaling | Edwards Signaling | Notifier (Honeywell) | Simplex (Johnson Controls) | Fire-Lite (Honeywell) | Potter Electric Signal |
| Package | Through-hole terminal plate kit | Through-hole terminal plate (same) | Through-hole terminal plate (same) | Through-hole terminal plate (same) | Through-hole terminal plate (same) | Through-hole terminal plate (same) | Through-hole terminal plate (same) |
| Compatible Panel Family | Edwards FireShield 3/5/10-zone | Edwards FireShield legacy | Edwards FireShield (current) | Notifier conventional series | Simplex 4007ES/4100ES | Fire-Lite MS-9200UDLS | Potter conventional panels |
| ULC Listed | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Resistor Value(s) | 1.1 k / 3.6 k / 4.7 kOhm (3 resistors) | Single-value plate (value varies) | Single-value plate (value varies) | 2.2 kOhm typical | Varies per Simplex firmware | Varies per Fire-Lite firmware | 1.8 kOhm fixed |
| Resistors per Kit | 3 | 1 | 1 | 1 | 1 | 1 | 1 |
| Lead Form / Mounting | Through-hole axial leads on terminal plate | Through-hole axial leads (same) | Through-hole axial leads (same) | Through-hole axial leads (same) | Through-hole axial leads (same) | Through-hole axial leads (same) | Through-hole axial leads (same) |
| Quantity per Circuit | 1 plate per IDC | 1 plate per IDC | 1 plate per IDC | 1 plate per IDC | 1 plate per IDC | 1 plate per IDC | 1 plate per IDC |
Principaux différenciateurs
- Multi-resistor kit handles every IDC configuration in one box (vs Potter EOL-1.8)
Notes de conception
Always match the EOL-P1 resistor value (1.1 kOhm, 3.6 kOhm, or 4.7 kOhm) to the Edwards FireShield firmware revision configured in the panel. Installing the wrong value almost always generates a persistent 'trouble' condition because the supervisory current falls outside the firmware's expected window. If the FireShield FACP indicates an IDC trouble immediately after power-up, the first item to verify is the EOL resistor value, before re-checking wire continuity.
Per ULC practice, install the EOL-P1 termination plate at the most distant end of the supervised initiating device circuit - never at the FACP terminals and never inside an intermediate detector base. Placing the EOL at the end-of-line allows detection of a wire break anywhere along the IDC; placing the EOL at the FACP masks failures between the panel and the first device. Recommended practice is a listed junction box at the last device location with the EOL-P1 plate screwed in and the resistor leads trimmed and sleeved.
Do not substitute generic carbon or metal-film resistors for the EOL-P1 kit in Canadian fire-alarm installations. The ULC listing is on the entire plate assembly shipped from Edwards, including the validated resistor voltage/temperature ratings and the plate mechanical footprint approved by ULC. An assembled-from-stock alternative may measure the same ohms on a meter but can fail ULC inspection and void the panel's ULC certification.
The EOL-P1 resistors see only the supervisory DC current of the FireShield IDC (typically a few milliamps at 24 VDC), not the alarm-current pulses. No thermal management is required, but verify each resistor's voltage and power rating exceeds the worst-case loop voltage. A typical 1/4 W through-hole resistor is more than sufficient for the supervisory current, but should not be substituted with a 1/8 W part without confirming the worst-case IDC voltage.
Per the Gordon Electric Supply listing, one EOL-P1 is required per supervised circuit. A common installer mistake is to install a single EOL plate at the FACP for all zones, which defeats per-circuit supervision and produces a persistent 'trouble' condition as soon as the second zone is wired in. Always allocate one EOL plate per initiating circuit on the FireShield 3-zone, 5-zone, or 10-zone FACP.
Informations de conformité
ULC-listed (Underwriters Laboratories of Canada) per FireAlarm.com and Gescan SKU descriptions. RoHS/REACH/lead-free status was not present in the retrieved distributor data. The EOL-P1 is a passive fire-alarm accessory, not an automotive-grade IC, so AEC-Q100 does not apply.