ICL7106SCPL - 3.5-Digit LCD A/D Converter | Harris
Référence : ICL7106SCPL ✓ ActifICL7106SCPL Présentation
An A/D converter transforms a continuously varying analog quantity into a numeric representation. A dual-slope integrating converter integrates the unknown input over a fixed interval, then measures the time required for a reference ramp to return to its starting level. This technique offers good noise rejection, particularly for frequencies near the converter's internal control frequency, while requiring relatively few external components. The ICL7106 belongs to the hierarchy ADC, data converter, analog-to-digital converter, and integrated circuit.
The ICL7106 integrates the A/D conversion function, reference circuitry, clock, seven-segment decoder, and multiplexed LCD backplane drive. According to the manufacturer ICL7106 data sheet, the device supports a 3.5-digit display format and a parallel-display architecture. The multiplexed backplane output reduces the number of display connections compared with driving every LCD segment independently, making the device suitable for compact digital meters and panel displays.
The ICL7106SCPL is a single-channel converter using a dual-slope conversion method. A typical measurement cycle integrates both an unknown input and a reference voltage, after which the converter compares the input against the reference and reports the result as decimal digits. Its integrated LCD circuitry requires compatible segment and backplane wiring, while the external reference and input network determine input range, scale factor, noise behavior, and the relationship between the measured voltage and the displayed result.
Typical uses include laboratory digital multimeters, panel meters, temperature controllers, laboratory scales, process-monitoring displays, and portable instrumentation. The LCD-specific ICL7106 is appropriate when the display uses liquid crystal segments; it should not be selected for a design requiring direct LED segment drive. Instrument designers can use the integrated decoder and display driver to reduce the number of external components and simplify the display interface.
A careful design must account for reference accuracy, input integration time, display timing, and LCD contrast. Follow the manufacturer data sheet for the reference capacitor, integration and deintegration capacitor values, clock selection, LCD segment mapping, and printed-board layout. Because the device uses a PDIP package, verify socket availability, board spacing, and assembly clearance before committing to a through-hole design.
This product record combines the manufacturer overview, distributor specifications, price evidence, package information, and practical implementation guidance. It also identifies the closest documented same-family replacement while distinguishing LCD display-driver operation from the LED-display version of the ICL7107, helping engineers make a safer PCB and sourcing decision.
Alternatives de remplacement direct pour ICL7106SCPL — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.
Variantes de cette série
Modèles de la même série directement compatibles avec ICL7106SCPL (même facteur de forme et même empreinte) — différant par Package.
ICL7106CPL+
✅ Remplacement directContactez-nous pour le prix
Voir la fiche technique →ICL7106CPLZ
✅ Remplacement directContactez-nous pour le prix
Voir la fiche technique →ICL7106SCPL Valeurs maximales et caractéristiques électriques
| Converter Type | 3.5-digit dual-slope A/D converter |
| Display Type | Multiplexed LCD |
| Output Interface | Parallel display output |
| Number of Channels | 1 channel |
| Résolution | 16-bit internal conversion |
| Conversion Rate | Approximately 3 samples per second |
| Tension d'alimentation | 15 V |
| Température de fonctionnement | 0°C to 70°C |
| Boîtier | 40-pin PDIP, 0.600 in (15.24 mm) pitch |
| Type de montage | Through hole |
| Carrier Type | Tube |
| Minimum Order Quantity | 99 units |
| Integrated Functions | Seven-segment decoder, LCD display driver, voltage reference, and clock |
| Input Type | Dual-slope integrating ADC |
| Display Format | 3.5-digit LCD |
| Statut RoHS | Compliant |
Guide de configuration des broches du ICL7106SCPL 40-pin pdip, 0.600 in (15.24 mm) pitch
Configuration des broches du ICL7106SCPL (boîtier 40-pin pdip, 0.600 in (15.24 mm) pitch). Ce composant analogique comporte des broches d'entrée, de sortie et d'alimentation. Consultez la fiche technique du fabricant pour les configurations des broches d'annulation d'offset, de compensation et d'activation. Idéal pour le conditionnement de signaux et les circuits amplificateurs.
Aucune donnée de brochage détaillée disponible pour ICL7106SCPL.
Consultez la fiche technique pour la configuration complète des broches.
Applications typiques
ICL7106SCPL convient pour 6 applications: Digital Panel Meter, Laboratory Digital Multimeter, Temperature Controller Display, Laboratory Scale Indicator, Process Monitoring Display, Portable Measurement Instrument.
Digital Panel Meter
The ICL7106SCPL is suited to a digital panel meter because it combines a one-channel, 3.5-digit dual-slope A/D converter with a seven-segment decoder and multiplexed LCD drive. The 40-pin PDIP footprint supports through-hole instrument construction, while the approximately 3 samples per second update rate is suitable for continuously changing panel readings. The meter designer can use the integrated backplane outputs to reduce display wiring and external logic. Input conditioning, reference accuracy, and the display segment map should be established from the manufacturer application circuit, and the LCD should be checked for contrast and multiplex timing over the full 0°C to 70°C operating range.
Recommandé
Laboratory Digital Multimeter
ICL7106SCPL provides the measurement and display core for a laboratory digital multimeter requiring a compact 3.5-digit LCD readout. Its integrated reference, clock, seven-segment decoder, and LCD backplane drive reduce the component count compared with a separate converter and display controller. The dual-slope architecture is particularly useful when rejecting periodic noise at the internal control frequency. At approximately 3 samples per second, the converter suits general voltage, current, and resistance measurements rather than high-speed waveform acquisition. Input switching, protection networks, reference calibration, and low-leakage resistor selection remain outside the IC and must be designed around the manufacturer’s recommended circuit.
Recommandé
Temperature Controller Display
ICL7106SCPL can display a temperature-derived voltage on a three-and-a-half-digit LCD in thermometers, process controllers, and industrial monitoring panels. The 15 V device operating range and 0°C to 70°C commercial specification fit many ambient industrial enclosures, while the approximately 3 samples per second refresh rate provides a readable update for slowly changing temperatures. A sensor amplifier, linearization circuit, or thermocouple cold-junction reference must convert the temperature into an analog voltage accepted by the converter. Because multiplexed LCD operation influences segment visibility, designers should test contrast, update rate, and viewing angle with the selected glass and follow the manufacturer’s component values for the reference and integration network.
Recommandé
Laboratory Scale Indicator
ICL7106SCPL forms the numeric readout of a laboratory scale or precision weighing indicator when the load-cell signal is conditioned into a suitable analog voltage. Its 3.5-digit format matches common zero, gross-weight, and net-weight indications, while the integrated LCD drive simplifies the display interface. The approximately 3 samples per second conversion rate is adequate for readings that change gradually, and the dual-slope method helps suppress repetitive interference. The instrument designer must account for excitation stability, bridge amplification, offset and gain calibration, decimal-point placement, and display refresh. The 40-pin PDIP construction also makes the converter appropriate for through-hole instrument boards where a socket may be used for serviceability.
Recommandé
Process Monitoring Display
ICL7106SCPL is useful in a process-monitoring panel that presents a pressure, flow, position, or concentration measurement on an LCD. The one-channel architecture accommodates a conditioned analog process signal, and the integrated reference, clock, decoder, and LCD backplane driver provide a compact measurement subsystem. At approximately 3 samples per second, the displayed value is appropriate for variables whose changes do not require high update bandwidth. The input network should include protection and filtering suited to the industrial environment, while the display refresh should avoid suggesting precision beyond the converter’s actual noise and reference performance. Follow the manufacturer’s layout guidance to keep sensitive analog and reference connections away from noisy switching nodes.
Recommandé
Portable Measurement Instrument
ICL7106SCPL supports portable handheld instruments where low component count, stable numeric conversion, and an integrated LCD interface are important. The device combines a 3.5-digit dual-slope converter with display decoding and backplane drive in one 40-pin PDIP device, simplifying a repairable through-hole assembly. Its listed 15 V supply and 0°C to 70°C temperature range suit many indoor instruments, while the approximately 3 samples per second rate is adequate for handheld meters measuring slow or quasi-static quantities. Battery operation requires attention to the regulator, display contrast, and input-signal leakage. Confirm startup behavior, reference settling, capacitor tolerances, and LCD visibility in the manufacturer’s recommended application circuit before production.
Recommandé
Récapitulatif des produits recommandés
Données de référence d'ingénierie pour ICL7106SCPL — comparaison, recommandations de conception et informations de conformité.
Guide de sélection
Comparaison avec les alternatives
| Paramètre | Ce produit | ICL7106CPL | ICL7106CPLZ |
|---|---|---|---|
| Brand | Harris Corporation | Harris Corporation | Harris Corporation |
| Package | 40-pin PDIP | 40-pin PDIP | 40-pin PDIP |
| Product Type | Display Driver Parallel 40-PDIP | 3.5-digit ADC 40-DIP | ICL7106 family 40-pin PDIP |
| Display Type | Multiplexed LCD | LCD | LCD |
| Number of Channels | 1 channel | 1 channel | 1 channel |
| Conversion Method | Dual-slope | Dual-slope | Dual-slope |
| Mounting Type | Through hole | Through hole | Through hole |
Principaux différenciateurs
- Integrated LCD-specific display drive (vs ICL7107CPLZ)
- Commercial-temperature PDP device (vs ICL7106CPL)
- Single-package meter subsystem (vs ICL7106CPLZ)
Notes de conception
Use the manufacturer’s printed-board layout as the starting point for the analog input, reference, clock, and display connections. Keep the high-impedance input and reference nodes short and shield them from display backplane and supply-return currents. The PDIP footprint requires 0.600 in (15.24 mm) lead pitch and approximately 0.600 in row spacing, so verify connector alignment, socket availability, and assembly clearance before layout release.
Do not substitute the ICL7107 for the ICL7106 without redesigning the display interface. The ICL7106 provides multiplexed LCD backplane drive, while the ICL7107 targets direct LED display drive. Although both families use a similar 40-pin PDIP outline, the segment-driver topology is functionally different. Confirm the display technology, segment count, polarity, and backplane connections against the exact manufacturer data sheet before treating either device as interchangeable.
Follow the manufacturer’s recommended reference and timing capacitor types and values, and account for capacitor tolerance and dielectric temperature coefficient when setting measurement accuracy. The 15 V supply must remain within the device rating, and reference-node disturbance can appear directly as measurement error. Decouple the supply close to the package and avoid routing switching-regulator or display-current paths across the analog reference area.
Design the LCD segment and backplane traces with the selected glass in mind. Multiplexed displays can exhibit flicker, ghosting, or contrast loss if segment timing, bias, and capacitor values are incorrect. Validate the display with the actual meter glass over the full 0°C to 70°C operating range. If leakage from the LCD, input protection network, or PCB surface contamination affects the dual-slope integration period, clean the board and review the input guarding arrangement.
Informations de conformité
The LCSC product listing identifies ICL7106SCPL as RoHS compliant. No AEC-Q100, REACH, halogen-free, lead-free, or conflict-minerals declaration was identified, so those attributes remain unknown.