ICL7106SCPL - 3.5-Digit LCD A/D Converter | Harris
MPN: ICL7106SCPL ✓ 啟用中ICL7106SCPL 概覽
An A/D converter transforms a continuously varying analog quantity into a numeric representation. A dual-slope integrating converter integrates the unknown input over a fixed interval, then measures the time required for a reference ramp to return to its starting level. This technique offers good noise rejection, particularly for frequencies near the converter's internal control frequency, while requiring relatively few external components. The ICL7106 belongs to the hierarchy ADC, data converter, analog-to-digital converter, and integrated circuit.
The ICL7106 integrates the A/D conversion function, reference circuitry, clock, seven-segment decoder, and multiplexed LCD backplane drive. According to the manufacturer ICL7106 data sheet, the device supports a 3.5-digit display format and a parallel-display architecture. The multiplexed backplane output reduces the number of display connections compared with driving every LCD segment independently, making the device suitable for compact digital meters and panel displays.
The ICL7106SCPL is a single-channel converter using a dual-slope conversion method. A typical measurement cycle integrates both an unknown input and a reference voltage, after which the converter compares the input against the reference and reports the result as decimal digits. Its integrated LCD circuitry requires compatible segment and backplane wiring, while the external reference and input network determine input range, scale factor, noise behavior, and the relationship between the measured voltage and the displayed result.
Typical uses include laboratory digital multimeters, panel meters, temperature controllers, laboratory scales, process-monitoring displays, and portable instrumentation. The LCD-specific ICL7106 is appropriate when the display uses liquid crystal segments; it should not be selected for a design requiring direct LED segment drive. Instrument designers can use the integrated decoder and display driver to reduce the number of external components and simplify the display interface.
A careful design must account for reference accuracy, input integration time, display timing, and LCD contrast. Follow the manufacturer data sheet for the reference capacitor, integration and deintegration capacitor values, clock selection, LCD segment mapping, and printed-board layout. Because the device uses a PDIP package, verify socket availability, board spacing, and assembly clearance before committing to a through-hole design.
This product record combines the manufacturer overview, distributor specifications, price evidence, package information, and practical implementation guidance. It also identifies the closest documented same-family replacement while distinguishing LCD display-driver operation from the LED-display version of the ICL7107, helping engineers make a safer PCB and sourcing decision.
直接替換替代品,適用於 ICL7106SCPL — 相同封裝,腳位對腳位相容。需重新設計 PCB 的不同封裝零件不列入。
此系列的變體
與下列產品可直接替換的同系列型號: ICL7106SCPL (相同外形與佔位) — 差異在於 Package.
ICL7106CPL+
✅ 直接替換聯絡詢價
查看資料表 →ICL7106CPLZ
✅ 直接替換聯絡詢價
查看資料表 →ICL7106SCPL 最大額定值與電氣特性
| Converter Type | 3.5-digit dual-slope A/D converter |
| Display Type | Multiplexed LCD |
| Output Interface | Parallel display output |
| Number of Channels | 1 channel |
| 解析度 | 16-bit internal conversion |
| Conversion Rate | Approximately 3 samples per second |
| 供應電壓 | 15 V |
| 工作溫度 | 0°C to 70°C |
| 封裝 | 40-pin PDIP, 0.600 in (15.24 mm) pitch |
| 安裝類型 | Through hole |
| Carrier Type | Tube |
| Minimum Order Quantity | 99 units |
| Integrated Functions | Seven-segment decoder, LCD display driver, voltage reference, and clock |
| Input Type | Dual-slope integrating ADC |
| Display Format | 3.5-digit LCD |
| RoHS 狀態 | Compliant |
ICL7106SCPL 40-pin pdip, 0.600 in (15.24 mm) pitch 腳位配置指南
ICL7106SCPL(40-pin pdip, 0.600 in (15.24 mm) pitch 封裝)的腳位配置。 此類比元件具有輸入、輸出與電源腳位。偏移歸零、補償與致能腳位配置請參閱製造商資料表。適用於訊號調理與放大器電路。
無詳細腳位定義資料: ICL7106SCPL.
請參閱 資料表 以查看完整腳位配置。
典型應用
ICL7106SCPL 適用於 6 應用s: Digital Panel Meter, Laboratory Digital Multimeter, Temperature Controller Display, Laboratory Scale Indicator, Process Monitoring Display, Portable Measurement Instrument.
Digital Panel Meter
The ICL7106SCPL is suited to a digital panel meter because it combines a one-channel, 3.5-digit dual-slope A/D converter with a seven-segment decoder and multiplexed LCD drive. The 40-pin PDIP footprint supports through-hole instrument construction, while the approximately 3 samples per second update rate is suitable for continuously changing panel readings. The meter designer can use the integrated backplane outputs to reduce display wiring and external logic. Input conditioning, reference accuracy, and the display segment map should be established from the manufacturer application circuit, and the LCD should be checked for contrast and multiplex timing over the full 0°C to 70°C operating range.
推薦
Laboratory Digital Multimeter
ICL7106SCPL provides the measurement and display core for a laboratory digital multimeter requiring a compact 3.5-digit LCD readout. Its integrated reference, clock, seven-segment decoder, and LCD backplane drive reduce the component count compared with a separate converter and display controller. The dual-slope architecture is particularly useful when rejecting periodic noise at the internal control frequency. At approximately 3 samples per second, the converter suits general voltage, current, and resistance measurements rather than high-speed waveform acquisition. Input switching, protection networks, reference calibration, and low-leakage resistor selection remain outside the IC and must be designed around the manufacturer’s recommended circuit.
推薦
Temperature Controller Display
ICL7106SCPL can display a temperature-derived voltage on a three-and-a-half-digit LCD in thermometers, process controllers, and industrial monitoring panels. The 15 V device operating range and 0°C to 70°C commercial specification fit many ambient industrial enclosures, while the approximately 3 samples per second refresh rate provides a readable update for slowly changing temperatures. A sensor amplifier, linearization circuit, or thermocouple cold-junction reference must convert the temperature into an analog voltage accepted by the converter. Because multiplexed LCD operation influences segment visibility, designers should test contrast, update rate, and viewing angle with the selected glass and follow the manufacturer’s component values for the reference and integration network.
推薦
Laboratory Scale Indicator
ICL7106SCPL forms the numeric readout of a laboratory scale or precision weighing indicator when the load-cell signal is conditioned into a suitable analog voltage. Its 3.5-digit format matches common zero, gross-weight, and net-weight indications, while the integrated LCD drive simplifies the display interface. The approximately 3 samples per second conversion rate is adequate for readings that change gradually, and the dual-slope method helps suppress repetitive interference. The instrument designer must account for excitation stability, bridge amplification, offset and gain calibration, decimal-point placement, and display refresh. The 40-pin PDIP construction also makes the converter appropriate for through-hole instrument boards where a socket may be used for serviceability.
推薦
Process Monitoring Display
ICL7106SCPL is useful in a process-monitoring panel that presents a pressure, flow, position, or concentration measurement on an LCD. The one-channel architecture accommodates a conditioned analog process signal, and the integrated reference, clock, decoder, and LCD backplane driver provide a compact measurement subsystem. At approximately 3 samples per second, the displayed value is appropriate for variables whose changes do not require high update bandwidth. The input network should include protection and filtering suited to the industrial environment, while the display refresh should avoid suggesting precision beyond the converter’s actual noise and reference performance. Follow the manufacturer’s layout guidance to keep sensitive analog and reference connections away from noisy switching nodes.
推薦
Portable Measurement Instrument
ICL7106SCPL supports portable handheld instruments where low component count, stable numeric conversion, and an integrated LCD interface are important. The device combines a 3.5-digit dual-slope converter with display decoding and backplane drive in one 40-pin PDIP device, simplifying a repairable through-hole assembly. Its listed 15 V supply and 0°C to 70°C temperature range suit many indoor instruments, while the approximately 3 samples per second rate is adequate for handheld meters measuring slow or quasi-static quantities. Battery operation requires attention to the regulator, display contrast, and input-signal leakage. Confirm startup behavior, reference settling, capacitor tolerances, and LCD visibility in the manufacturer’s recommended application circuit before production.
推薦
推薦產品摘要
工程參考資料,適用於 ICL7106SCPL — 比較、設計指引及合規資訊。
選型指南
與替代品比較
| 參數 | 本產品 | ICL7106CPL | ICL7106CPLZ |
|---|---|---|---|
| Brand | Harris Corporation | Harris Corporation | Harris Corporation |
| Package | 40-pin PDIP | 40-pin PDIP | 40-pin PDIP |
| Product Type | Display Driver Parallel 40-PDIP | 3.5-digit ADC 40-DIP | ICL7106 family 40-pin PDIP |
| Display Type | Multiplexed LCD | LCD | LCD |
| Number of Channels | 1 channel | 1 channel | 1 channel |
| Conversion Method | Dual-slope | Dual-slope | Dual-slope |
| Mounting Type | Through hole | Through hole | Through hole |
主要差異化特點
- Integrated LCD-specific display drive (對比ICL7107CPLZ)
- Commercial-temperature PDP device (對比ICL7106CPL)
- Single-package meter subsystem (對比ICL7106CPLZ)
設計說明
Use the manufacturer’s printed-board layout as the starting point for the analog input, reference, clock, and display connections. Keep the high-impedance input and reference nodes short and shield them from display backplane and supply-return currents. The PDIP footprint requires 0.600 in (15.24 mm) lead pitch and approximately 0.600 in row spacing, so verify connector alignment, socket availability, and assembly clearance before layout release.
Do not substitute the ICL7107 for the ICL7106 without redesigning the display interface. The ICL7106 provides multiplexed LCD backplane drive, while the ICL7107 targets direct LED display drive. Although both families use a similar 40-pin PDIP outline, the segment-driver topology is functionally different. Confirm the display technology, segment count, polarity, and backplane connections against the exact manufacturer data sheet before treating either device as interchangeable.
Follow the manufacturer’s recommended reference and timing capacitor types and values, and account for capacitor tolerance and dielectric temperature coefficient when setting measurement accuracy. The 15 V supply must remain within the device rating, and reference-node disturbance can appear directly as measurement error. Decouple the supply close to the package and avoid routing switching-regulator or display-current paths across the analog reference area.
Design the LCD segment and backplane traces with the selected glass in mind. Multiplexed displays can exhibit flicker, ghosting, or contrast loss if segment timing, bias, and capacitor values are incorrect. Validate the display with the actual meter glass over the full 0°C to 70°C operating range. If leakage from the LCD, input protection network, or PCB surface contamination affects the dual-slope integration period, clean the board and review the input guarding arrangement.
合規資訊
The LCSC product listing identifies ICL7106SCPL as RoHS compliant. No AEC-Q100, REACH, halogen-free, lead-free, or conflict-minerals declaration was identified, so those attributes remain unknown.