INA240A3PWR - 100V/V Zero-Drift Current Sense Amp | TI
Référence : INA240A3PWR ✓ ActifINA240A3PWR Présentation
A current-sense amplifier is an analog signal-conditioning device that converts the small voltage across a current shunt into a larger, measurable voltage. The INA240 belongs to the instrumentation-amplifier and current-sense-amplifier hierarchy, where accurate offset behavior and common-mode rejection are essential for recovering a current measurement from a low-amplitude differential signal. Its output voltage represents the shunt differential voltage multiplied by a fixed gain of 100 V/V.
The A3 gain version provides a nominal output of 1 V for every 10 mV across the shunt. Its zero-drift architecture reduces input-offset contributions that otherwise change with temperature, improving accuracy in systems that require stable current measurements over wide operating ranges. The -4 V to 80 V common-mode capability also supports sensing during transient intervals in systems containing inductive loads, while enhanced PWM rejection helps suppress errors produced by fast-switching motor-control waveforms.
The INA240 family uses a voltage-output architecture and can measure current in either direction when the output is biased with a reference voltage. The reference pin permits the output to be centered around a nonzero voltage, which is important for systems that must report both positive and negative current without saturating the output at zero. A low typical supply current of 90 μA also helps reduce the overhead introduced by the measurement channel.
Typical applications include three-phase inverter motor control, DC motor current monitoring, solenoid current tracking, battery-management systems, power-supply load reporting, and industrial actuator control. In a motor inverter, the device can sit beside the low-side shunt and retain usable operation through the switching transitions. In a bidirectional system, the reference voltage shifts the zero-current output level so that positive and negative current can be distinguished at a single analog input.
Designers should place the shunt and amplifier inputs on a compact, symmetric trace arrangement, connect the reference pin to a low-impedance bias network when bidirectional output is required, and keep output routing away from high-voltage switching nodes. The power-supply and ground pins require careful decoupling, while input filtering should preserve the common-mode and timing performance needed by the application.
Alternatives de remplacement direct pour INA240A3PWR — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.
Variantes de cette série
Modèles de la même série directement compatibles avec INA240A3PWR (même facteur de forme et même empreinte) — différant par PWM Rejection, Package.
INA240A3QPWRQ1
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
INA240A3PWR Valeurs maximales et caractéristiques électriques
| Device Type | Bidirectional zero-drift current-sense amplifier |
| Number of Amplifiers | 1 amplifier |
| Gain | 100 V/V |
| Common-Mode Input Voltage Range | -4 V to 80 V |
| Type de sortie | Analog voltage output |
| Typical Supply Current | 90 μA |
| PWM Rejection | Enhanced |
| Plage de température de fonctionnement | -40 °C to 125 °C |
| Boîtier | 8-pin TSSOP |
| Type de montage | Surface mount |
| Statut RoHS | Compliant |
Configuration des broches de INA240A3PWR
| Broche 1 | IN+ — Positive input for shunt differential voltage |
| Broche 2 | GND — Ground connection |
| Broche 3 | IN- — Negative input for shunt differential voltage |
| Broche 4 | REF — Reference input for output-voltage bias |
| Broche 5 | OUT — Analog voltage output |
| Broche 6 | VS — Positive power-supply connection |
| Broche 7 | IN+ — Positive input for shunt differential voltage |
| Broche 8 | IN- — Negative input for shunt differential voltage |
Applications typiques
INA240A3PWR convient pour 6 applications: Three-Phase Inverter Motor Control, DC Motor Current Monitoring, Solenoid and Actuator Current Tracking, Bidirectional Battery Current Measurement, Industrial Power-Supply Load Reporting, Bidirectional Converter Feedback.
Three-Phase Inverter Motor Control
The INA240A3PWR fits low-side shunt sensing in a three-phase inverter because its -4 V to 80 V common-mode range remains valid during many switching transitions. A 10 mV shunt drop creates a 1 V output at the 100 V/V gain, which can feed a precision ADC or control comparator. Enhanced PWM rejection helps preserve the current-feedback signal when the inverter switches rapidly. The designer must still verify the instantaneous shunt voltage, amplifier output swing, supply level, and ADC input range across all operating states.
Recommandé
DC Motor Current Monitoring
INA240A3PWR can monitor armature or phase current in a DC motor drive while keeping the sensing chain precise and compact. Its 100 V/V gain converts a 10 mV shunt differential into a 1 V analog signal, improving use of the available ADC range for modest shunt drops. Bidirectional operation permits forward motoring and regenerative current to be observed with an appropriate reference bias. Layout remains critical because power-switch currents can create ground displacement and differential input errors across the shunt connection.
Recommandé
Solenoid and Actuator Current Tracking
The INA240A3PWR is well suited to solenoid and actuator feedback because its common-mode range extends to -4 V, allowing the sensing amplifier to operate during negative flyback intervals. The 100 V/V gain preserves a usable measurement from a low-amplitude shunt drop while the voltage-output architecture connects naturally to an ADC or comparator. Designers should check the flyback magnitude against the absolute device ratings, protect the shunt path against excessive current, and use filtering that preserves the intended control bandwidth.
Recommandé
Bidirectional Battery Current Measurement
INA240A3PWR can measure charge and discharge current when its reference pin biases the output around mid-supply. At a 100 V/V gain, a 10 mV shunt voltage produces a 1 V change relative to the reference level, allowing both current directions to be distinguished by the downstream converter. The negative common-mode capability is useful in systems whose shunt voltage can cross ground. The reference network must have low noise and low output impedance, and its voltage must leave sufficient headroom for the expected positive and negative current excursions.
Recommandé
Industrial Power-Supply Load Reporting
The INA240A3PWR can measure load current in industrial power-supply or power-distribution equipment where the shunt may sit at a substantial common-mode voltage. Its -4 V to 80 V input range supports operation across low- and high-side arrangements, and the 100 V/V gain provides useful scaling for a 10 mV shunt drop. For accurate load reporting, select the shunt dissipation and thermal rating for the maximum current, keep the Kelvin shunt connections isolated from power-current paths, and account for amplifier offset and gain error during calibration.
Recommandé
Bidirectional Converter Feedback
INA240A3PWR provides an analog feedback signal for a bidirectional converter when current must be measured in both directions. The 100 V/V scaling increases the resolution available from a small shunt drop, while a reference bias establishes the zero-current output level. This arrangement can support digital control loops that need faster current information than a software-only estimate. The feedback filter, reference voltage, and ADC range should be designed together so that startup transients and maximum load current do not saturate the output or exceed the converter's control range.
Recommandé
Récapitulatif des produits recommandés
Données de référence d'ingénierie pour INA240A3PWR — comparaison, recommandations de conception et informations de conformité.
Guide de sélection
Comparaison avec les alternatives
| Paramètre | Ce produit | INA240A3QPWRQ1 |
|---|---|---|
| Brand | Texas Instruments | Texas Instruments |
| Package | 8-pin TSSOP | 8-pin TSSOP |
| Gain | 100 V/V | 100 V/V |
| Common-Mode Input Range | -4 V to 80 V | -4 V to 80 V |
| Bidirectional Sensing | Yes | Yes |
| Output Type | Analog voltage | Analog voltage |
| PWM Rejection | Enhanced | Enhanced |
Principaux différenciateurs
- Maintains the same electrical gain and package while adding automotive qualification (vs INA240A3QPWRQ1)
- Wide common-mode operating range supports high-voltage and below-ground sensing (vs INA240A3QPWRQ1)
- Zero-drift architecture supports stable measurement over temperature (vs INA240A3QPWRQ1)
Notes de conception
Route IN+ and IN− as a compact, symmetric differential pair directly from the shunt Kelvin connections to the amplifier. Avoid sharing the high-current path with the sense traces, because voltage drops in copper and vias can appear as measurement error. Place the shunt near the power-current transition only when its thermal isolation permits, and connect the sense pins directly to the intended shunt pads to minimize added copper resistance.
Decouple the VS supply pin with the capacitance and placement specified by the Texas Instruments INA240 datasheet. Keep the supply-return path short and separate from high-current switching returns so ground bounce does not enter the input and output signal path. If the amplifier supply can be switched independently of the sensed common-mode voltage, verify that the supply remains valid while the input pins encounter transient voltages.
Do not treat the -4 V to 80 V common-mode range as permission to exceed the absolute maximum ratings. Check the instantaneous voltage on IN+ and IN− during faults, shutdown, and inductive transients. Also verify output saturation: with a 100 V/V gain, a shunt drop beyond a few tens of millivolts can exceed the available output range at low supply voltages.
When bidirectional sensing is required, drive REF from a low-impedance reference and include the filtering recommended in the INA240 application information. Avoid a high-value reference resistor that could increase noise or disturb startup. Set the reference voltage so the full positive and negative shunt-current range remains inside the amplifier output swing, not merely inside the nominal supply voltage.
Informations de conformité
RoHS compliance is stated by comparison records for the INA240 family. The target ordering option's REACH, lead-free, halogen-free, conflict-minerals, and AEC-Q100 status require confirmation in the applicable Texas Instruments documentation.