Texas Instruments

ISO100CP - 750V Isolation Amplifier, 60kHz | Texas Instruments

Référence : ISO100CP ✗ Fin de vie
En stock Expédié sous 1 à 3 jours ouvrés
750 V Vdss VOUT/IIN = RF Id 18-CDIP, 0.300 inch, 7.62 mm Package
Contact pour connaître le prix
MOQ : 1 |
Prix mis à jour : 2026-10-22
Tarifs dégressifs
Qté Prix unitaire Total
1 $0 $0,00
10 $0 $0,00
100 $0 $0,00
500 $0 $0,00
1 000 $0 $0,00
ℹ️ Tous les prix sont en USD

ISO100CP Présentation

The Texas Instruments ISO100CP is an optically coupled isolation amplifier rated for 750 V continuous isolation voltage, featuring a 60 kHz signal bandwidth and a maximum input-side leakage current of 0.3 uA at 240 V RMS, 60 Hz. It is packaged as a single-channel amplifier in an 18-pin CDIP measuring 0.300 inch, or 7.62 mm.

An isolation amplifier belongs to the signal-chain hierarchy of operational amplifiers and instrumentation amplifiers, but its defining function is galvanic isolation between input and output domains. This category transfers an analog measurement across a high-impedance barrier while limiting electrical current between the two sides. The ISO100CP is therefore suited to systems where a sensor or shunt is electrically connected to hazardous, high-voltage, or earth-referenced equipment that must remain separately controlled.

The part supports two transfer relationships identified in the source material: VOUT/IIN equals RF for current-input use and VOUT/VIN equals RF/RIN for voltage-input use. Its 100% tested 750 V continuous isolation capability supports robust reinforced separation where the application and system safety requirements permit. The 60 kHz bandwidth is suitable for measurement signals that need accurate transfer without operating as an ultra-low-frequency instrumentation amplifier.

Optically coupled internal construction provides the barrier function, while the external resistors establish current- or voltage-to-output scaling. Because the verified source does not publish the complete electrical tables or a complete pin map, resistor values, gain tolerance, supply limits, common-mode range, and settling performance should be taken directly from the manufacturer datasheet before design release. Verify that the complete 18-pin CDIP footprint and pin names match the target PCB.

Typical uses include isolated current measurement, power-converter control feedback, industrial sensor interfaces, instrumentation channels, and high-voltage test equipment. The key engineering consideration is that isolation rating does not replace application-specific safety design: creepage, clearance, barrier construction, insulation coordination, and enclosure requirements must be evaluated separately.

The ISO100CP combines a 60 kHz isolation-amplifier channel, 750 V continuous isolation rating, 0.3 uA maximum leakage specification, and 18-CDIP package in one through-hole device. It is appropriate when the system needs a conventional resistor-programmed isolation signal path rather than a small surface-mount digital isolator.

This page synthesizes the supplied distributor information, manufacturer-linked datasheet material, package facts, sourcing context, and design cautions. Because no verified pin-compatible substitute was returned by the cross-reference search, it does not invent a five-part replacement list or present unreferenced competitor devices as drop-in alternatives.

Alternatives de remplacement direct pour ISO100CP — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.

Variantes de cette série

Modèles de la même série directement compatibles avec ISO100CP (même facteur de forme et même empreinte) — différant par Product Type.

Texas Instruments
Product Type: Optically coupled linear isolation amplifier
Comparer avec ISO100CP →

Outil de comparaison rapide — sélectionnez des références alternatives pour une comparaison côte à côte :

Aucune alternative de remplacement direct disponible pour ce produit.

Demander des alternatives

ISO100CP Valeurs maximales et caractéristiques électriques

Product Type Optically coupled isolation amplifier
Number of Channels 1 circuit
Continuous Isolation Voltage 750 V
Isolation Test 100% tested for breakdown
Maximum Isolation Leakage 0.3 uA at 240 V RMS, 60 Hz
Signal Bandwidth 60 kHz
Current-Input Transfer Relationship VOUT/IIN = RF
Voltage-Input Transfer Relationship VOUT/VIN = RF/RIN
Boîtier 18-CDIP, 0.300 inch, 7.62 mm
Nombre de broches 18 pins
Terminal Form Through-hole
Package Shape Rectangular
Type de montage Through-hole

Guide de configuration des broches du ISO100CP rectangular

Configuration des broches du ISO100CP (boîtier rectangular). Ce composant analogique comporte des broches d'entrée, de sortie et d'alimentation. Consultez la fiche technique du fabricant pour les configurations des broches d'annulation d'offset, de compensation et d'activation. Idéal pour le conditionnement de signaux et les circuits amplificateurs.

Schéma de brochage du boîtier rectangular pour le ISO100CP

Aucune donnée de brochage détaillée disponible pour ISO100CP.

Consultez la fiche technique pour la configuration complète des broches.

Applications typiques

ISO100CP convient pour 6 applications: Isolated Shunt Measurement, Industrial Sensor Isolation, Power-Converter Control Feedback, High-Voltage Test and Measurement, Current-Mode Control Interfaces, Instrumentation and Data Acquisition.

⚡

Isolated Shunt Measurement

The ISO100CP fits isolated current measurement because the verified datasheet text specifies VOUT/IIN = RF for current-input operation. A shunt can be placed on the high-side or low-side according to the application circuit, while the isolation amplifier transfers the measured current to a grounded controller side. Its 60 kHz bandwidth allows the channel to handle substantially faster variation than a precision low-frequency meter, although the shunt value and amplifier input network must satisfy the manufacturer's resistor and bias requirements.

🏭

Industrial Sensor Isolation

The Texas Instruments ISO100CP is applicable when a transducer is located at a high-impedance or earth-referenced boundary and its measurement must be transferred into another electrical domain. The optically coupled isolation topology and verified 750 V continuous isolation rating help limit electrical coupling, while 60 kHz bandwidth supports faster sensor signals than a static precision amplifier. The circuit must provide separate supply arrangements as required by the datasheet and must include filtering appropriate to the sensor output.

⚡

Power-Converter Control Feedback

ISO100CP can condition a feedback-control signal when the power stage and controller require isolation. The verified 60 kHz bandwidth is relevant to converter loops that cannot tolerate a very slow isolation path, and the 0.3 uA maximum leakage specification at 240 V RMS, 60 Hz provides evidence of low barrier leakage. Loop compensation, propagation delay, gain tolerance, and stable resistor values remain to be selected from the full datasheet rather than inferred from the brief source excerpt.

🧩

High-Voltage Test and Measurement

The ISO100CP is relevant to isolated test channels because it combines a 750 V continuous isolation rating with a 60 kHz bandwidth and through-hole 18-CDIP construction. It can transfer a bounded measurement signal from a hazardous test domain into lower-energy equipment, reducing common-mode effects across the isolation boundary. Engineering must still establish working voltage, clearance, creepage, pollution degree, insulation type, fuse or resistor strategy, and enclosure compliance for the complete apparatus.

🔧

Current-Mode Control Interfaces

The ISO100CP may be used where a current command or sensed current must cross an isolation boundary in a control system. Its current-input equation, VOUT/IIN = RF, provides a direct design starting point, while 60 kHz bandwidth gives the loop designer a stated operating band. The verified excerpt does not include input impedance, permitted common-mode voltage, or supply requirements; these values must be confirmed before selecting external current sources or protection components.

🖥️

Instrumentation and Data Acquisition

The ISO100CP supports an isolated instrumentation channel when a sensor output must be acquired without sharing a ground reference with the host system. Voltage-input and current-input configurations allow reuse across different transducers, while the 60 kHz bandwidth is useful for dynamic measurements. For multi-channel acquisition, evaluate channel-to-channel isolation, source impedance, settling behavior, anti-alias filtering, and calibration against the complete manufacturer data before finalizing the PCB.

What is the Texas Instruments ISO100CP?
The Texas Instruments ISO100CP is a single-channel, optically coupled isolation amplifier in an 18-CDIP package. According to the manufacturer datasheet indexed in the verified data, it supports VOUT/IIN = RF for current input and VOUT/VIN = RF/RIN for voltage input, allowing the same isolation concept to address different sensor outputs. The source identifies the device as one isolation-amplifier circuit rather than a general-purpose operational amplifier.
What is the isolation voltage of ISO100CP?
The ISO100CP provides 750 V continuous isolation voltage and is 100% tested for breakdown, according to the verified manufacturer-datasheet text. That rating describes the component's tested isolation capability, not permission to exceed it without a complete safety assessment. Designers must still verify working voltages, insulation type, pollution degree, creepage, clearance, and applicable system safety requirements before placing either side of the device at hazardous potential.
What is the bandwidth of ISO100CP?
The ISO100CP has a 60 kHz signal bandwidth in the supplied datasheet listing. This makes it applicable to analog measurement channels that require isolation and more bandwidth than a precision slow-speed instrumentation amplifier. The verified excerpt does not provide phase error, settling time, rise time, or full frequency-response plots, so those values must be read from the manufacturer datasheet before sizing filters or timing control loops.
What is the maximum leakage current of ISO100CP?
The ISO100CP is specified in the verified source for ultra-low leakage of no more than 0.3 uA at 240 V RMS, 60 Hz. That condition must be preserved during comparison: leakage is tied to the stated voltage and frequency and should not be extrapolated to other operating conditions without manufacturer data. It is particularly relevant when the isolated side is connected through high-impedance sensing circuits.
Where can I download the ISO100CP datasheet PDF?
The verified datasheet PDF is available at https://www.datasheets.com/texas-instruments/iso100cp/datasheet.pdf. The search results also identify ISO100 as an optically coupled isolation-amplifier family and link the ISO100CP data to ISO100AP and ISO100BP. Before using the document for design release, confirm the pin assignments, recommended external resistor values, supply limits, thermal limits, and test conditions in the actual PDF.
What package and pinout does ISO100CP use?
The ISO100CP uses an 18-pin CDIP measuring 0.300 inch, or 7.62 mm, with through-hole terminals. Distributor and cross-reference results identify 18 terminals, a rectangular DIP package, and through-hole construction. The supplied excerpts do not expose the pin-by-pin schematic, so a complete pinout cannot be reproduced reliably here; use the manufacturer pin configuration and verify every connection against the 18-pin footprint.
Where can I buy ISO100CP online?
ISO100CP is listed for online sourcing through DigiKey, with additional listings visible through Octopart and other distributors in the verified search results. DigiKey describes the part as a one-circuit, 18-CDIP isolation amplifier, while Heisener reports 5,328 pieces in its referenced listing. Stock and price are dynamic; request a current quote and confirm manufacturer condition, authorized-source status, and date before ordering as of 2026-10-22.
What is the price of ISO100CP?
The verified data does not provide a numeric unit price for ISO100CP, so no price can be stated reliably as of 2026-10-22. Heisener requests a quotation, Octopart reports comparison across six distributors, and other marketplace results require RFQ or inventory confirmation. Engineers should obtain a current authorized-distributor quote for the exact MPN and quantity, and separately assess any nonauthorized marketplace listing.
What is the lead time for ISO100CP?
The available Heisener result states that ISO100CP can ship immediately and shows an estimated delivery window of January 7 through January 12, but the year and fulfillment method are not established by the supplied excerpt. Therefore, no universal lead time can be confirmed as of 2026-10-22. Confirm current quantity, factory allocation, authorized-channel availability, and the supplier's promised lead time in writing.
Is ISO100CP in stock?
ISO100CP appears available from several marketplace listings in the verified results, but availability is not uniform across sellers. Heisener's page reports 5,328 pieces, while other suppliers use RFQ or stock-check language. Treat only a supplier's live confirmation as current inventory as of 2026-10-22, especially when traceability, date code, or authorized-channel provenance is important.
Can ISO100CP be used for current-sensor isolation?
Yes, ISO100CP supports current-input signal conditioning through the relationship VOUT/IIN = RF. Place the isolation amplifier in a circuit compatible with its input-side bias, supply, and common-mode requirements, then choose RF from the manufacturer resistor table. The verified 60 kHz bandwidth makes the device relevant to wider-band current measurements, but shunt impedance, burden voltage, and sensor rise time must remain within unverified limits taken directly from the datasheet.
Can ISO100CP measure voltage inputs?
The ISO100CP supports voltage-input configurations using VOUT/VIN = RF/RIN. The source text explicitly identifies this transfer relationship, making the device applicable to isolated voltage sensing when its input-side electrical limits are satisfied. Confirm the precise input range, impedance, offset, gain accuracy, and allowable source resistance in the manufacturer datasheet because those numerical values are not present in the supplied excerpts.
What can replace ISO100CP without changing the PCB?
No verified drop-in replacement for ISO100CP was found in the supplied cross-reference search. The results repeatedly identify the original TI device but do not establish another 18-CDIP isolation amplifier with the same pinout, 750 V continuous isolation rating, and compatible transfer equations. Do not substitute a generic isolation amplifier or different package based only on the 60 kHz bandwidth; validate the footprint, every electrical limit, barrier construction, and safety requirements first.
When should I choose ISO100CP over another isolation amplifier?
Choose ISO100CP when the design specifically needs an 18-CDIP isolation amplifier with 60 kHz bandwidth, 750 V continuous isolation voltage, and resistor-programmed current- or voltage-input transfer. The verified evidence does not support a meaningful comparison against a named substitute, so selection should prioritize exact circuit requirements rather than assumed compatibility. Consider alternatives only when a manufacturer documents the same footprint, pin functions, supply scheme, transfer equations, and isolation ratings.
Is ISO100CP suitable for industrial isolation and high-voltage test equipment?
ISO100CP is potentially suitable for industrial isolation and high-voltage measurement channels because its verified features include 750 V continuous isolation voltage, 60 kHz bandwidth, and low 0.3 uA maximum leakage at the stated test condition. Suitability still depends on the working voltage, insulation coordination, environmental contamination, temperature, and enclosure. These system-level details are not supplied, so treat this as component-level evidence rather than a complete safety approval.

Données de référence d'ingénierie pour ISO100CP — comparaison, recommandations de conception et informations de conformité.

Guide de sélection

Choose ISO100CP when the design specifically needs a through-hole 18-CDIP isolation amplifier with a verified 60 kHz bandwidth, 750 V continuous isolation rating, and resistor-programmed current- or voltage-input transfer. The most important constraints are the exact pin configuration, input-side bias and common-mode limits, supply arrangement, gain accuracy, and working-voltage conditions; none should be inferred from the brief search excerpts. The supplied cross-reference search found no defensible pin-compatible substitute, so changing platforms generally requires a design review rather than a simple distributor cross-reference. Use ISO100CP only after validating the complete application circuit, isolation geometry, filter requirements, and applicable safety rules. If the 18-CDIP footprint is unnecessary, a modern surface-mount isolation amplifier may offer easier assembly, but it must be treated as a redesign unless its manufacturer explicitly documents pin compatibility.

Comparaison avec les alternatives

Paramètre Ce produit
Package 18-CDIP, 0.300 inch, 7.62 mm
Brand Texas Instruments
Product Type Optically coupled isolation amplifier
Number of Channels 1 circuit
Continuous Isolation Voltage 750 V
Maximum Isolation Leakage 0.3 uA at 240 V RMS, 60 Hz
Signal Bandwidth 60 kHz
Current-Input Transfer VOUT/IIN = RF
Voltage-Input Transfer VOUT/VIN = RF/RIN
Mounting Type Through-hole

Principaux différenciateurs

  • Verified 750 V continuous isolation capability (vs No verified drop-in alternative supplied)
  • 60 kHz signal bandwidth (vs No verified drop-in alternative supplied)
  • Configurable current- and voltage-input transfer (vs No verified drop-in alternative supplied)

Notes de conception

Keep the isolated input and output networks physically separated so copper, solder mask, and exposed leads do not create an unintended low-impedance barrier path. Follow the manufacturer isolation-layout recommendations exactly, including component placement on only their respective domains. Do not route protective-earth or high-voltage conductors beneath the device unless the approved insulation system explicitly allows it.

Treat the two amplifier sides as separate circuit domains and verify every supply requirement from the manufacturer datasheet before adding bypass capacitors. The supplied source confirms the isolation mechanism but not supply voltage, current, sequencing, or grounding limits. In particular, do not connect grounds solely because they appear at the same schematic level; doing so can defeat the isolation function.

Do not equate the 750 V continuous isolation figure with unrestricted working voltage at every frequency, temperature, pollution degree, or overvoltage condition. The 0.3 uA leakage maximum applies specifically at 240 V RMS, 60 Hz, and the 60 kHz figure is signal bandwidth, not a guarantee of loop accuracy above that frequency. Confirm test conditions, derating rules, and application safety requirements from the complete datasheet.

Select RF and RIN only after checking the complete resistor tables and parasitic limits. The source text establishes VOUT/IIN = RF and VOUT/VIN = RF/RIN, but it does not provide resistor ranges, source-impedance restrictions, output drive capability, or tolerance curves. Place feedback and gain-setting parts close to their associated pins and provide filtering only after measuring the complete isolation path response.

Informations de conformité

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
Sans plomb
Unknown
Sans halogène
Unknown
Minerais de conflit
Unknown

The supplied verified excerpts do not state RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals status. No compliance claim is inferred from the manufacturer name or from general distributor listings.

Données vérifiées le : 2026-10-22 — données vérifiées et sélectionnées par l'équipe d'ingénierie composants de XAIPART

Recherches associées

ISO100CP Texas Instruments ISO100CP datasheet PDF ISO100CP 750V isolation amplifier ISO100CP 60kHz bandwidth ISO100CP 18-CDIP package ISO100CP pinout ISO100CP current input isolation amplifier ISO100CP drop-in replacement ISO100CP price and stock Where to buy ISO100CP online How does ISO100CP work ISO100CP isolation leakage 0.3 uA

Composants & termes associés

Texas Instruments ISO100CP ISO100 ISO100AP ISO100BP isolation amplifier instrumentation amplifier operational amplifier analog signal chain optical isolation galvanic isolation current-input signal conditioning voltage-input signal conditioning continuous isolation voltage isolation leakage current signal bandwidth 18-CDIP DIP package family through-hole surface-mount package hierarchy VOUT/IIN transfer relationship VOUT/VIN transfer relationship industrial sensor interface power-converter feedback high-voltage test equipment
RFQ de devis rapide
Renseignez tous les détails — notre équipe commerciale vous répondra sous 24 heures
Référence Fabricant Boîtier QTY Prix cible Total
Total : 0,00 USD
✓
Devis envoyé !

Nous répondrons à votre e-mail sous 24 heures

1
RFQ envoyée
2
Devis reçu
3
Commande passée
4
Paiement
5
Expédié
6
Livré
Voir les détails de la RFQ