ISO121G Présentation

The Texas Instruments ISO121G is a precision low-cost isolated amplifier with a ±10 V input range, one amplifier circuit, and a 16-pin CDIP package. According to the Texas Instruments product page, it is designed for precision voltage sensing, while the manufacturer datasheet identifies low nonlinearity, bipolar operation, and duty-cycle modulation-demodulation as central characteristics. Its isolation barrier transfers the signal digitally rather than relying on analog leakage through the barrier, helping preserve signal integrity in electrically noisy or high-voltage environments.

An isolated amplifier is a signal-conditioning component that transfers a measured voltage across an electrically isolated barrier while preventing direct conductive coupling between the input and output domains. The ISO121G belongs to the broader isolation-amplifier and instrumentation-amplifier hierarchy: it measures a differential voltage, encodes that measurement through a modulated carrier, reconstructs it on the isolated side, and drives a precision output. This makes it useful where a measurement reference must be separated from the control or processing ground.

The ISO121 datasheet highlights a differential capacitive barrier of 2 pF, user control of carrier frequency, and low nonlinear operation of ±0.01% maximum. The search data also identifies the ISO121 as rated for 3500 Vrms partial-discharge testing, high common-mode transient immunity at 60 Hz, and bipolar input operation across a stated 0.3-wide range in the source summary. Exact operating limits, gain settings, supply-current values, and timing parameters must be taken from the complete manufacturer datasheet rather than inferred from search snippets.

The ISO121G is suited to industrial voltage monitoring, isolated process-control interfaces, power-converter feedback, instrumentation, and test systems. The device is a through-hole 16-CDIP part, so its mechanical footprint is appropriate for conventional through-hole PCB layouts rather than compact surface-mount assemblies. The isolated barrier and precision signal path should be treated as a complete analog-measurement subsystem, with attention to input common-mode range, supply sequencing, isolation creepage and clearance, decoupling, grounding, and output loading.

The key design consideration is that isolation does not remove the need for careful analog layout. Keep input traces short, place supply and bypass capacitors near their associated pins, maintain the required barrier spacing, and avoid routing sensitive input nets beneath or beside isolation-related structures. Confirm the complete datasheet limits before selecting resistor values, carrier frequency, output filtering, or external protection components. This page combines distributor availability, manufacturer references, and engineering guidance to support initial design review rather than replacing the official datasheet.

This page also provides procurement context and selection guidance for engineers comparing ISO121G with related isolation-amplifier options. Available distributor pricing and stock can change, so confirm current pricing, lifecycle status, and exact package details before committing a production BOM.

Alternatives de remplacement direct pour ISO121G — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.

Variantes de cette série

Modèles de la même série directement compatibles avec ISO121G (même facteur de forme et même empreinte) — différant par Carrier Frequency, Product Type, Package, Nonlinearity, Isolation Barrier.

Texas Instruments
Carrier Frequency: User control
Product Type: Precision low-cost isolation amplifier
Package: 24-CDIP hermetic DIP, 16 leads
Comparer avec ISO121G →
Texas Instruments
Product Type: Precision low-cost isolation amplifier
Nonlinearity: ±0.01% maximum at the precision operating condition
Comparer avec ISO121G →
Texas Instruments
Carrier Frequency: User-controlled (external capacitor)
Product Type: Isolation Amplifier
Package: 16-pin CDIP_SB (JVD) side-brazed ceramic DIP
Comparer avec ISO121G →

Outil de comparaison rapide — sélectionnez des références alternatives pour une comparaison côte à côte :

ISO121BG

✅ Remplacement direct
Texas Instruments
📦 16-CDIP
Isolation Amplifier · 1 · ±10 V · 3500 Vrms · ±0.01 % · ±4.5 V to ±18 V · High (per datasheet) · Duty-cycle modulation/demodulation

✓ En stock

$19.2 / unité

Voir la fiche technique →

ISO120BG

✅ Remplacement direct
Texas Instruments
📦 16-CDIP
Precision low-cost isolation amplifier · 1 circuit · 60 kHz · ±0.01% maximum · Bipolar operation · 1500 Vrms · 100% tested · 2 pF differential capacitive barrier

✓ En stock

Contactez-nous pour le prix

Voir la fiche technique →

ISO120SG

✅ Remplacement direct
Texas Instruments
📦 16-CDIP
Precision low-cost isolation amplifier · Duty-cycle modulation and demodulation across a 2 pF differential capacitive barrier · 60 kHz · 1500 Vrms · ±0.01% maximum at the precision operating condition · 150 µV/°C maximum with the specified external-capacitor and reduced-bandwidth condition · High IMR at 60 Hz · User controlled

✓ En stock

$471.7929 / unité

Voir la fiche technique →

ISO121G Valeurs maximales et caractéristiques électriques

Product Type Precision isolated amplifier
Input Signal Range ±10 V
Isolation Rating 3500 Vrms partial-discharge tested
Differential Capacitive Barrier 2 pF
Nonlinearity ±0.01% maximum
Input Operation Bipolar operation
Carrier Frequency User controlled
Common-Mode Transient Immunity High at 60 Hz; quantitative value not provided
Amplifier Circuit Count 1 circuit
Boîtier 16-CDIP
Type de montage Through-hole
Nombre de broches 16 pins
AEC-Q100 Qualification Not specified in verified data

Guide de configuration des broches du ISO121G 16-cdip

Configuration des broches du ISO121G (boîtier 16-cdip). Ce composant analogique comporte des broches d'entrée, de sortie et d'alimentation. Consultez la fiche technique du fabricant pour les configurations des broches d'annulation d'offset, de compensation et d'activation. Idéal pour le conditionnement de signaux et les circuits amplificateurs.

Schéma de brochage du boîtier 16-cdip pour le ISO121G

Aucune donnée de brochage détaillée disponible pour ISO121G.

Consultez la fiche technique pour la configuration complète des broches.

Applications typiques

ISO121G convient pour 6 applications: Isolated Industrial Voltage Sensing, Power-Converter Feedback, Instrumentation and Signal Conditioning, Test and Measurement Systems, Isolated Process-Control Interface, Isolated Data Acquisition.

🏭

Isolated Industrial Voltage Sensing

The ISO121G fits isolated voltage sensing when the sensed signal is within its verified ±10 V input range and the measurement system must be separated from the control or processing ground. Its precision isolated-amplifier architecture is intended to preserve measurement integrity across a barrier, while the 3500 Vrms partial-discharge-tested isolation specification provides a useful basis for high-voltage design review. The circuit should include local input conditioning, supply decoupling, and output filtering selected from the complete manufacturer datasheet.

⚡

Power-Converter Feedback

Use ISO121G in power-converter feedback when the feedback voltage falls within the verified ±10 V range and galvanic isolation is required between the power stage and control circuitry. The device’s duty-cycle modulation-demodulation architecture transfers the measurement across the 2 pF differential capacitive barrier, reducing dependence on analog barrier transmission. Designers should account for propagation behavior, carrier-frequency selection, output settling, and the complete electrical limits before closing a power-control loop.

📟

Instrumentation and Signal Conditioning

ISO121G is suitable for instrumentation front ends that must measure bipolar voltages while maintaining an isolated signal path. The verified datasheet summary identifies low nonlinearity of ±0.01% maximum and bipolar operation, making the device relevant to precision measurement rather than ordinary high-voltage switching. Use it with stable supplies, well-defined grounding, input protection, and output buffering as required by the measurement bandwidth and calibration plan.

🧪

Test and Measurement Systems

The ISO121G can be used in isolated test fixtures and measurement systems where the input source must remain electrically separated from the instrument ground. Its ±10 V input range covers many external analog measurement signals, and the barrier architecture supports robust signal transfer when common-mode transients are present. Calibration should account for the complete gain, offset, bandwidth, and temperature specifications from the official data, which are not fully exposed in the supplied search snippets.

🏭

Isolated Process-Control Interface

ISO121G supports process-control interfaces that need a bipolar voltage transferred across an isolation barrier before conversion or control. Its precision isolation architecture is appropriate when the process ground and controller ground must remain separate, and its verified 3500 Vrms partial-discharge testing is relevant to barrier validation. The implementation must still address isolation creepage, clearance, surge protection, input filtering, and output settling according to the application’s safety and measurement requirements.

🖥️

Isolated Data Acquisition

ISO121G can be placed between a bipolar sensor or divider network and an isolated data-acquisition front end. The ±10 V input specification gives the analog path a defined signal range, while low nonlinearity and user-controlled carrier frequency support measurement-system planning. Keep the input network close to the device, use low-noise grounding, and confirm output compatibility with the following ADC before layout is released. The complete TI datasheet remains the authority for gain, bandwidth, and timing calculations.

What is the ISO121G?
The ISO121G is a Texas Instruments precision isolated amplifier designed for isolated voltage sensing. According to the Texas Instruments product page, it accepts a ±10 V input, and the manufacturer datasheet describes a duty-cycle modulation-demodulation architecture that transfers the signal across a 2 pF differential capacitive barrier. The part is used when a measurement signal must cross an isolation boundary without direct conductive coupling between input and output grounds.
What is the input voltage range of ISO121G?
The ISO121G supports a ±10 V input range, as stated on the Texas Instruments ISO121 product page. That means the nominal input specification covers signals from negative 10 V through positive 10 V under the conditions and limitations defined by the complete datasheet. Designers should also verify the input common-mode limits, gain configuration, supply requirements, and absolute maximum ratings before applying the part.
Where can I download the ISO121G datasheet PDF?
The official ISO121G datasheet PDF is available from Texas Instruments at https://www.ti.com/lit/ds/symlink/iso121.pdf. The manufacturer product page is also available at https://www.ti.com/product/ISO121. The search data identifies the ISO121G as a single-circuit, 16-CDIP precision isolation amplifier. Use the manufacturer document for final electrical limits, pin functions, test conditions, and application guidance.
Where can I find the ISO121G pinout?
The ISO121G pinout should be taken from the official Texas Instruments ISO121 datasheet and its 16-CDIP package drawing. The verified distributor information identifies a 16-CDIP package, but the supplied search snippets do not include the individual pin names or pin numbers. Therefore, the complete pin assignments cannot be reconstructed safely here. Review the datasheet package drawing before laying out a PCB or connecting supplies, inputs, outputs, and carrier-control components.
How much does ISO121G cost and where can I buy it?
The verified LCSC listing reports an ISO121G price of $160.4014 and identifies the part as in stock, while DigiKey and Mouser also provide product listings. Pricing is distributor- and date-sensitive; the available price should therefore be confirmed as of 2026-10-22 before purchase. The verified data does not establish a single universal market price or a complete quantity-break schedule for every supplier.
Is ISO121G in stock?
ISO121G is reported as in stock by the verified LCSC listing as of the supplied retrieval data. The same data also includes DigiKey, Mouser, Win Source, and Rochester Electronics listings, but their snippets do not provide a consistent stock quantity. Treat LCSC availability as source-specific and time-sensitive, and confirm current inventory, lead time, and authorized-channel status before placing an order.
What is the lead time for ISO121G?
A numeric ISO121G lead time is not provided in the verified web data. The LCSC result states that the component is in stock, while other distributor pages list pricing and availability without exposing a guaranteed lead time. Request a current quotation from the distributor and confirm the required quantity, date code, and delivery location. Do not infer a production lead time from a search-result stock label alone.
Is ISO121G a drop-in replacement for ISO120G?
The verified cross-reference results include comparisons between ISO120-family and ISO121-family devices, but they do not provide a manufacturer recommendation or complete quantitative pin-and-parameter comparison. Because ISO120 and ISO121 share a family architecture, ISO121G may appear in same-package comparisons; however, a replacement should not be approved without checking the exact package, pinout, input range, gain, supply limits, isolation rating, and timing behavior. Treat any substitution as an engineering validation item, not an automatic drop-in claim.
What is the best drop-in replacement for ISO121G?
The verified data does not establish five or more validated drop-in replacements for ISO121G, so a best replacement cannot be named responsibly. The search results show ISO121-related and ISO120-related comparison pages, but they do not provide enough verified package, pin, and electrical data to claim drop-in equivalence. A valid replacement must use the same 16-CDIP footprint, match pin functions, and meet the required ±10 V input, isolation, gain, supply, and accuracy specifications.
What is the difference between ISO121G and ISO121BG?
ISO121G and ISO121BG are both listed as 16-CDIP isolated amplifier variants, but the verified snippets do not provide a complete manufacturer comparison of their orderable temperature grades, lifecycle terms, or electrical differences. The Utmel comparison identifies ISO121BG as a single isolation amplifier in a 16-CDIP package, while the DigiKey results identify ISO121G as a single-circuit 16-CDIP part. Verify the suffix-specific datasheet, marking, temperature grade, and supply availability before substitution.
ISO121G vs ISO121BG: which one should I choose?
Choose ISO121G when its manufacturer ordering information and current distributor availability match the required production specification; choose ISO121BG only after confirming that its suffix-specific electrical and environmental ratings meet the design. The verified data confirms that both names are associated with 16-CDIP isolation-amplifier entries, but it does not provide a complete parameter table. Compare the exact suffix datasheet entries, temperature range, qualification status, and lifecycle information rather than relying on the base-family comparison.
Can ISO120BG replace ISO121G?
ISO120BG should not be treated as an automatic replacement for ISO121G. The verified search results include an ISO121G-versus-ISO120BG comparison and describe both parts as belonging to the precision isolation-amplifier family, but the supplied data does not prove identical pin functions or equivalent key parameters. Verify the ±10 V input requirement, gain, carrier-frequency control, isolation rating, supply range, package dimensions, and timing before using ISO120BG as a replacement.
When should I choose ISO121G over an ISO120-family device?
Choose ISO121G when the design specifically requires the ISO121 family’s verified ±10 V input range and its associated precision isolated-measurement characteristics. Choose an ISO120-family device only after its exact data sheet confirms that its input range, gain, bandwidth, isolation performance, pinout, and power requirements satisfy the same system requirements. The verified data supports the ISO121G family identification but does not provide a complete ISO120-versus-ISO121 decision matrix.
What are the key specifications of ISO121G that engineers should know?
The key verified ISO121G facts are a ±10 V input range, one isolation-amplifier circuit, a 16-CDIP package, a 2 pF differential capacitive barrier, and low nonlinearity of ±0.01% maximum. The manufacturer datasheet also describes user-controlled carrier frequency and bipolar operation, while the supplied data identifies 3500 Vrms partial-discharge testing. Supply voltage, gain, bandwidth, temperature range, and complete pin assignments remain datasheet-dependent.
What design considerations apply when using ISO121G?
Use ISO121G with careful isolation and analog-layout practices. Place bypass capacitors near the supply pins, keep the isolated input section physically separated from the output and logic domains, preserve the required creepage and clearance, and route high-impedance input traces away from switching nodes. Because the verified snippets do not provide the complete pinout or recommended layout values, follow the official TI datasheet and application guidance for final component placement and protection.

Données de référence d'ingénierie pour ISO121G — comparaison, recommandations de conception et informations de conformité.

Guide de sélection

Choose ISO121G when your system needs the verified ISO121-family ±10 V input range, bipolar measurement capability, and a 16-CDIP isolation-amplifier implementation. Its duty-cycle modulation-demodulation architecture and 2 pF differential capacitive barrier are appropriate for transferring measurements across an isolation boundary. ISO121BG may be considered only after confirming its suffix-specific electrical and environmental ratings. ISO120BG and ISO120SG are related family options, but the supplied data does not prove drop-in equivalence; their lower stated ISO120 partial-discharge rating and unspecified key parameters require direct comparison. For production, confirm lifecycle status, current stock, lead time, and manufacturer support because the verified results report inconsistent availability and only one explicit price.

Comparaison avec les alternatives

Paramètre Ce produit ISO121BG ISO120BG ISO120SG
Brand Texas Instruments Texas Instruments Texas Instruments Texas Instruments
Package 16-CDIP 16-CDIP 16-CDIP 16-CDIP
Isolation Architecture Duty-cycle modulation-demodulation ISO121-family precision isolation amplifier ISO120-family precision isolation amplifier ISO120-family precision isolation amplifier

Principaux différenciateurs

  • Verified ISO121-family input range (vs ISO120BG)
  • Higher partial-discharge test rating in the supplied family summary (vs ISO120BG)
  • Precision low-cost isolated measurement positioning (vs ISO120SG)

Notes de conception

Treat the isolation barrier as a layout-controlled region. Preserve the manufacturer-specified creepage and clearance between input-side and output-side copper, avoid placing high-voltage or fast-switching traces beneath the barrier, and keep the input return path physically associated with the isolated input domain. The supplied snippets do not provide PCB dimensions or pad geometry, so use the official TI package drawing and application guidance for the final layout.

Keep the ±10 V input network close to ISO121G and minimize loop area before the first filtering or protection node. Place input protection, divider components, and any anti-alias filter according to the signal bandwidth and source impedance rather than only its DC voltage. The verified datasheet summary identifies user-controlled carrier frequency, so carrier selection and filtering must be evaluated together with settling time and required measurement accuracy.

Verify supply voltage, supply-current, sequencing, and output-loading requirements directly from the complete ISO121G datasheet before designing the power rails. Add local decoupling close to the device pins and account for the current drawn by both isolated domains. Because the supplied data does not state the supply range or quiescent current, do not select regulators or bulk capacitors from search-result information alone.

Informations de conformité

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Sans plomb
Unknown
Sans halogène
Unknown
Minerais de conflit
Unknown

The supplied product and distributor snippets do not provide verified RoHS, REACH, lead-free, halogen-free, conflict-minerals, or AEC-Q100 statements. ISO121G is an analog isolation amplifier, so AEC-Q100 is recorded as not applicable rather than inferred.

Données vérifiées le : 2026-10-22 — données vérifiées et sélectionnées par l'équipe d'ingénierie composants de XAIPART

Recherches associées

ISO121G Texas Instruments ISO121G datasheet PDF ISO121G ±10 V isolated amplifier ISO121G 16-CDIP pinout ISO121G price ISO121G buy online ISO121G vs ISO121BG ISO121G vs ISO120BG ISO121G drop-in replacement precision isolated voltage sensing amplifier 16-CDIP isolation amplifier ISO121G industrial voltage sensing where to buy ISO121G what can replace ISO121G

Composants & termes associés

Texas Instruments ISO121G ISO121 ISO121BG ISO120BG ISO120SG precision isolated amplifier isolation amplifier instrumentation amplifier voltage sensing duty-cycle modulation-demodulation differential capacitive barrier 2 pF capacitive barrier ±10 V input 3500 Vrms partial-discharge testing 1500 Vrms ISO120 partial-discharge testing bipolar operation user-controlled carrier frequency ±0.01% nonlinearity 16-CDIP through-hole package industrial process control power-converter feedback test and measurement
RFQ de devis rapide
Renseignez tous les détails — notre équipe commerciale vous répondra sous 24 heures
Référence Fabricant Boîtier QTY Prix cible Total
Total : 0,00 USD
✓
Devis envoyé !

Nous répondrons à votre e-mail sous 24 heures

1
RFQ envoyée
2
Devis reçu
3
Commande passée
4
Paiement
5
Expédié
6
Livré
Voir les détails de la RFQ