Texas Instruments

ISO120SG - Precision Isolation Amplifier | Texas Instruments

Référence : ISO120SG ✗ Fin de vie
En stock Expédié sous 1 à 3 jours ouvrés
1500 Vrms Vdss 16-CDIP according to the DigiKey listing; 24-CDIP with 16 leads according to the Heisener listing Package User controlled Speed
À partir de $471.7929 USD / unité
MOQ : 1 |
Prix mis à jour : 2026-10-22
Tarifs dégressifs
Qté Prix unitaire Total
1 $471.7929 $471,79
10 $471.7929 $4 717,93
100 $471.7929 $47 179,29
500 $471.7929 $235 896,45
1 000 $471.7929 $471 792,90
ℹ️ Tous les prix sont en USD

ISO120SG Présentation

The Texas Instruments ISO120SG is a precision, low-cost isolation amplifier with a 60 kHz bandwidth, low nonlinearity, and a 2 pF differential capacitive isolation barrier. The supplied distributor data identifies a 16-lead CDIP configuration for ISO120SG, although another distributor listing states 24-CDIP with 16 leads; the package designation must therefore be confirmed against the manufacturer ordering information before PCB release.

An isolation amplifier is an instrumentation-amplifier derivative that transfers a differential input signal across a galvanic-isolation barrier while preventing conductive current between the input and output domains. The ISO120 family uses duty-cycle modulation and demodulation to encode the analog input as a carrier signal, cross the capacitive barrier, and recover it at the output. This architecture makes the device suitable for measuring low-level signals in electrically noisy or hazardous environments where a common ground cannot be shared.

According to the supplied manufacturer and distributor references, the ISO120SG is a one-circuit isolation amplifier with 60 kHz signal bandwidth, bipolar operation, low nonlinearity, and user control of carrier frequency. The ISO120 family is also described as 100% tested for partial discharge and rated for 1500 Vrms isolation; these claims should be checked against the applicable ISO120 datasheet before using the part in a safety-critical design. The family supports operation without external components for 60 kHz bandwidth, while two external capacitors can enable precision specifications at reduced bandwidth.

Typical uses include industrial process-control channels, isolated sensor interfaces, medical monitoring equipment, power-conversion feedback, data-acquisition systems, and galvanically isolated communications. The isolation barrier allows a field-side input circuit and output-side signal chain to use separate ground domains, reducing common-mode current paths and protecting sensitive equipment from ground-potential differences.

The key design issue is package verification. DigiKey describes ISO120SG as a 16-CDIP part, while Heisener describes a 24-CDIP package with 16 leads. Do not select a footprint or publish a complete pinout until the exact ordering suffix and mechanical drawing are confirmed. Also verify whether the required isolation rating, creepage, clearance, and barrier construction fit the final safety standard.

This page consolidates the verified manufacturer identification, distributor descriptions, sourcing references, and application guidance while marking unresolved package and detailed electrical values rather than guessing them.

Alternatives de remplacement direct pour ISO120SG — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.

Variantes de cette série

Modèles de la même série directement compatibles avec ISO120SG (même facteur de forme et même empreinte) — différant par Carrier Frequency, Product Type, Package, Nonlinearity, Isolation Barrier.

Texas Instruments
Carrier Frequency: User control
Package: 24-CDIP hermetic DIP, 16 leads
Nonlinearity: ±0.01% maximum
Comparer avec ISO120SG →
Texas Instruments
Carrier Frequency: User-controlled (external capacitor)
Product Type: Isolation Amplifier
Package: 16-pin CDIP_SB (JVD) side-brazed ceramic DIP
Comparer avec ISO120SG →
Texas Instruments
Product Type: Precision isolated amplifier
Package: 16-CDIP
Nonlinearity: ±0.01% maximum
Comparer avec ISO120SG →

Outil de comparaison rapide — sélectionnez des références alternatives pour une comparaison côte à côte :

Aucune alternative de remplacement direct disponible pour ce produit.

Demander des alternatives

ISO120SG Valeurs maximales et caractéristiques électriques

Product Type Precision low-cost isolation amplifier
Isolation Architecture Duty-cycle modulation and demodulation across a 2 pF differential capacitive barrier
Signal Bandwidth 60 kHz
Isolation Voltage Rating 1500 Vrms
Nonlinearity ±0.01% maximum at the precision operating condition
Input Offset Voltage Drift 150 µV/°C maximum with the specified external-capacitor and reduced-bandwidth condition
Common-Mode Rejection High IMR at 60 Hz
Carrier Frequency User controlled
Supply Operation Bipolar operation
Number of Circuits 1 isolation amplifier per package
Package Information 16-CDIP according to the DigiKey listing; 24-CDIP with 16 leads according to the Heisener listing
Package Family Ceramic dual in-line package (CDIP)
Partial Discharge Qualification 100% tested for partial discharge
External Components None required for 60 kHz bandwidth; two external capacitors used for specified precision operation
Synchronization ISO120 family synchronization feature

Guide de configuration des broches du ISO120SG ceramic dual in-line package (cdip)

Configuration des broches du ISO120SG (boîtier ceramic dual in-line package (cdip)). Ce composant analogique comporte des broches d'entrée, de sortie et d'alimentation. Consultez la fiche technique du fabricant pour les configurations des broches d'annulation d'offset, de compensation et d'activation. Idéal pour le conditionnement de signaux et les circuits amplificateurs.

Schéma de brochage du boîtier ceramic dual in-line package (cdip) pour le ISO120SG

Aucune donnée de brochage détaillée disponible pour ISO120SG.

Consultez la fiche technique pour la configuration complète des broches.

Applications typiques

ISO120SG convient pour 6 applications: Industrial Process-Control Signal Isolation, Medical Patient-Monitoring Front End, Power-Conversion Feedback Isolation, Data-Acquisition and Instrumentation, Isolated Sensor Interface for Industrial Equipment, Isolated Communications and Control Interfaces.

🏭

Industrial Process-Control Signal Isolation

ISO120SG fits isolated process-control channels where a low-level differential sensor signal must cross from a field-side ground domain to a controller-side ground domain. Its 60 kHz bandwidth supports process signals without requiring the reduced-bandwidth precision configuration, while the 1500 Vrms family isolation rating can help separate hazardous or noisy field wiring from control electronics. The capacitive barrier avoids a conductive input-output path. Design confirmation is still required for the final isolation standard, working voltage, creepage, clearance, and temperature range.

💊

Medical Patient-Monitoring Front End

ISO120SG can be considered for isolated low-level biomedical signal acquisition because it transfers a differential analog signal across a capacitive barrier and offers a precision isolation-amplifier architecture. The 60 kHz mode is useful for many sensor and instrumentation signals, while the family’s low nonlinearity and drift-focused option support measurement accuracy. Medical use requires separate verification of applicable patient-protection requirements, isolation type, leakage, creepage, clearance, and certification; those claims are not established by the supplied snippets.

⚡

Power-Conversion Feedback Isolation

ISO120SG is suitable for power-conversion feedback paths when the controller needs a voltage or current measurement transferred across a high-common-mode barrier. Its 60 kHz bandwidth allows feedback information to pass without the extreme bandwidth of a communications isolator, and user-controlled carrier frequency provides a design variable for system filtering and interference management. The engineer must still verify supply voltage, input range, output swing, isolation working voltage, and thermal performance against the complete ISO120 datasheet.

🖥️

Data-Acquisition and Instrumentation

ISO120SG can isolate a differential instrumentation input from an ADC, data-acquisition module, or laboratory measurement system. The 60 kHz bandwidth is appropriate for many sensor and transducer signals, and the modulation approach avoids relying on barrier capacitance as a linear analog signal path. For high-resolution acquisition, the design should account for the device’s gain, input range, output settling, bandwidth, and accuracy specifications, which are not fully present in the supplied snippets and must be taken from the manufacturer datasheet.

🧩

Isolated Sensor Interface for Industrial Equipment

ISO120SG is a candidate for pressure, temperature, current, and other differential sensor interfaces where the sensor is exposed to substantial ground-potential differences. The capacitive barrier and high IMR at 60 Hz help reduce common-mode interference transfer, while the available 60 kHz mode preserves useful signal bandwidth. The package conflict in the supplied distributor records is especially important here: confirm whether the production suffix uses the 16-CDIP or 24-CDIP outline before selecting connectors, sockets, or PCB land patterns.

🌐

Isolated Communications and Control Interfaces

ISO120SG may be used where an analog control signal must pass between equipment domains with different ground potentials, such as an actuator-control partition or an industrial communication controller. The 60 kHz bandwidth is more than adequate for many slow analog-control signals, and user-controlled carrier frequency allows the system to select a compatible operating condition. Because this is an analog isolation amplifier rather than a digital isolator, signal integrity, bandwidth settling, and isolation capacitance must be evaluated in the actual channel.

What is the ISO120SG?
The ISO120SG is a Texas Instruments precision, low-cost isolation amplifier designed to transfer an analog signal across a capacitive isolation barrier. According to the verified Texas Instruments product reference and supplied datasheet results, it uses duty-cycle modulation and demodulation across a 2 pF differential capacitive barrier and provides 60 kHz signal bandwidth. The device is intended for instrumentation and signal-conditioning systems requiring galvanic isolation.
What is the ISO120SG bandwidth?
The ISO120SG provides 60 kHz bandwidth without external components according to the supplied ISO120 datasheet information. The family can use two external capacitors to obtain specified precision characteristics at reduced bandwidth, including 0.01% maximum nonlinearity and 150 µV/°C maximum offset-voltage drift. The precise capacitor values and bandwidth trade-off must be taken from the manufacturer datasheet for the implemented configuration.
How much isolation voltage does ISO120SG provide?
The supplied ISO120 family information states a 1500 Vrms isolation rating. This rating is associated with the ISO120 family and must not be interpreted as a complete safety certification for every ISO120SG application. The designer must still verify working voltage, creepage, clearance, package construction, insulation type, and applicable medical or industrial safety requirements.
Is ISO120SG a drop-in replacement for ISO121?
ISO120SG is not automatically a drop-in replacement for ISO121G or ISO121BG. The supplied comparison data indicates that ISO120 and ISO121 differ in package size and isolation-voltage rating, while both use related duty-cycle modulation techniques. A replacement requires exact package, pinout, isolation rating, supply, bandwidth, and safety-layout verification rather than a functional-family assumption.
What package does ISO120SG use?
The verified distributor information contains conflicting package descriptions: DigiKey lists ISO120SG as a 16-CDIP, while Heisener describes a 24-CDIP package with 16 leads. The exact package must be confirmed from the Texas Instruments ordering information and mechanical drawing. Do not use the PCB footprint or complete pinout until that conflict is resolved.
Where can I download the ISO120SG datasheet?
The official Texas Instruments datasheet link provided for this part is https://www.ti.com/lit/gpn/iso120. It is titled “Precision Low Cost Isolation Amplifier” and is the appropriate source for pin assignments, electrical limits, isolation details, application circuits, and package drawings. Search results also identify an 18-page copy, but the page count should be verified from the current PDF rather than relied on as ordering information.
Does ISO120SG require external capacitors?
The ISO120 family does not require external components for its 60 kHz bandwidth mode, according to the supplied manufacturer datasheet result. Two external capacitors can be added for specified precision operation at a lower bandwidth, including improved guaranteed nonlinearity and offset-drift behavior. The exact topology and capacitor values must follow the manufacturer application guidance.
Where can I buy ISO120SG online?
ISO120SG is listed by DigiKey at https://www.digikey.com/en/products/detail/texas-instruments/ISO120SG/301063, where the result states “Buy now, ships today.” Other supplied distributor references include Heisener, DiGi-Electronics, Semiconductors-IC.com, and datasheet.com. Availability and price can change, so request a current quotation and confirm authorized sourcing before placing a production order.
What is the ISO120SG price?
The supplied Heisener result gives a unit price of $471.7929 for ISO120SG, with the price shown for reference only and shipment timing subject to seller confirmation. The current price is therefore $471.7929 as of the supplied web result dated 2026-10-22, not a guaranteed quote. Use the distributor checkout or RFQ for a binding commercial price.
What is the lead time for ISO120SG?
The supplied Heisener listing states that ISO120SG can ship immediately and gives an estimated delivery window of February 2 through February 7, without a clearly identified year. This is a source listing rather than a guaranteed current lead time. Because the current date is 2026-10-22, confirm inventory, date, quantity, and shipping terms directly with the distributor before release.
Is ISO120SG in stock?
ISO120SG is shown as in stock by the supplied Heisener result, which reports 18,948 pieces and immediate shipping capability. DigiKey also uses a “ships today” call-to-action in its result title. Stock figures are dynamic and may not apply to your requested quantity, so verify allocation and seller authorization at the time of purchase.
When should I choose ISO120SG over another isolation amplifier?
Choose ISO120SG when the design needs a precision, low-cost isolation amplifier with 60 kHz bandwidth, user-controlled carrier frequency, low nonlinearity, and a capacitive isolation barrier. It is particularly useful when the input and output domains cannot share ground and when a low-frequency precision mode is acceptable. Choose a different device when the required isolation class, package, bandwidth, supply voltage, or safety certification does not match the verified ISO120 family data.
What can replace ISO120SG?
No verified, pin-compatible drop-in replacement for ISO120SG was identified in the supplied cross-reference search. ISO120G, ISO120BG, ISO121G, and ISO121BG appear in related family and comparison results, but the available snippets do not establish identical package pinout, isolation rating, and electrical parameters. Treat them as related devices requiring engineering review, not drop-in replacements.
What is the best cross-brand equivalent for ISO120SG?
No cross-brand drop-in equivalent is verified by the supplied web data. The returned cross-reference results are generic lubricant, component-finder, or Texas Instruments family references and do not identify another manufacturer’s part with the same package and pinout. A cross-brand alternative should not be selected until its isolation rating, package drawing, pinout, bandwidth, accuracy, supply requirements, and safety qualification are independently verified.
Is ISO120SG suitable for industrial sensor isolation?
ISO120SG is suitable in principle for industrial sensor-isolation interfaces because it provides capacitive isolation, 60 kHz bandwidth, high IMR at 60 Hz, and user-controlled carrier frequency. The final suitability depends on the sensor signal range, required accuracy, isolation class, surge environment, creepage, clearance, and operating temperature. Those application-specific limits are not all supplied in the verified snippets.
How should ISO120SG be used in a precision measurement circuit?
Use ISO120SG as the analog isolation stage between a differential sensor input and the downstream measurement or control circuitry, keeping the input and output grounds separated. Configure the carrier frequency according to the manufacturer guidance and use the specified external capacitors only when the required reduced-bandwidth precision mode is acceptable. Confirm grounding, bypass capacitors, creepage, clearance, and package details against the official datasheet.

Données de référence d'ingénierie pour ISO120SG — comparaison, recommandations de conception et informations de conformité.

Guide de sélection

Choose ISO120SG when the system needs a low-cost, precision analog isolation amplifier, approximately 60 kHz bandwidth, a capacitive barrier, and user control of carrier frequency. It is a strong candidate for industrial sensor interfaces, power-conversion feedback, and data-acquisition channels where separate input and output grounds are mandatory. The related ISO120G and ISO120BG parts may be useful, but the supplied web results do not prove exact pin compatibility. ISO121G and ISO121BG should not be selected as drop-in substitutes without checking their different package size and 3500 Vrms family isolation rating. No cross-brand drop-in replacement is verified. Before release, confirm the exact ISO120SG package because supplier listings conflict, obtain the official datasheet, validate supply and signal ranges, and check all isolation, creepage, clearance, temperature, and qualification requirements.

Comparaison avec les alternatives

Paramètre Ce produit ISO120G ISO120BG ISO121G ISO121BG
Package CDIP package; supplier descriptions conflict CDIP package; exact suffix must be verified CDIP package; exact suffix must be verified CDIP package; exact suffix must be verified CDIP package; exact suffix must be verified
Brand Texas Instruments Texas Instruments Texas Instruments Texas Instruments Texas Instruments
Product Type Precision isolation amplifier Related ISO120 isolation amplifier Related ISO120 isolation amplifier Related ISO121 isolation amplifier Related ISO121 isolation amplifier

Principaux différenciateurs

  • Low-cost precision isolation-amplifier positioning (vs Generic isolated signal-chain solutions)
  • User-controlled carrier frequency (vs ISO121 family variants listed in supplied comparison data)
  • Low nonlinearity in precision configuration (vs Higher-bandwidth communication-oriented isolation devices)

Notes de conception

Resolve the package conflict before layout: DigiKey identifies ISO120SG as a 16-CDIP, while the Heisener result describes a 24-CDIP with 16 leads. Use the Texas Instruments ordering information, package drawing, and pin table as the authority. A wrong footprint can prevent assembly or cause incorrect connections to the isolation barrier and supply pins.

Treat the isolation barrier, input-side ground, and output-side ground as separate layout regions. Keep the analog input path and associated filtering away from output-side switching nodes, maintain the manufacturer’s required creepage and clearance, and avoid placing high-voltage or fast-current copper beneath the barrier. Verify the final layout against the applicable isolation and safety requirements rather than relying only on nominal isolation voltage.

Use the 60 kHz no-external-component mode only when the resulting signal bandwidth is adequate. When precision nonlinearity and offset-drift limits are required, use the manufacturer’s two-capacitor configuration and accept the corresponding bandwidth reduction. Place input, output, bypass, and optional compensation capacitors according to the datasheet return path so that parasitic loading does not distort the isolation channel.

Informations de conformité

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
Sans plomb
Unknown
Sans halogène
Unknown
Minerais de conflit
Unknown

The supplied data identifies partial-discharge testing for the ISO120 family but does not provide verified ISO120SG RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals declarations. Compliance must be confirmed from the current manufacturer product documentation.

Données vérifiées le : 2026-10-22 — données vérifiées et sélectionnées par l'équipe d'ingénierie composants de XAIPART

Recherches associées

ISO120SG ISO120SG datasheet PDF Texas Instruments ISO120SG ISO120SG isolation amplifier ISO120SG 60 kHz bandwidth ISO120SG CDIP package ISO120SG 1500 Vrms isolation ISO120SG industrial sensor isolation ISO120SG vs ISO121G ISO120SG drop-in replacement ISO120SG buy price ISO120SG pinout precision capacitive isolation amplifier ISO120SG medical monitoring interface ISO120SG lead time and stock

Composants & termes associés

Texas Instruments ISO120SG ISO120 ISO121 precision low-cost isolation amplifier isolation amplifier instrumentation amplifier duty-cycle modulation duty-cycle demodulation 2 pF differential capacitive barrier galvanic isolation 60 kHz bandwidth 1500 Vrms isolation ISO121G ISO121BG ISO120G ISO120BG CDIP ceramic dual in-line package partial-discharge testing industrial sensor isolation power-conversion feedback medical monitoring data acquisition carrier frequency nonlinearity offset-voltage drift high IMR
RFQ de devis rapide
Renseignez tous les détails — notre équipe commerciale vous répondra sous 24 heures
Référence Fabricant Boîtier QTY Prix cible Total
Total : 0,00 USD
✓
Devis envoyé !

Nous répondrons à votre e-mail sous 24 heures

1
RFQ envoyée
2
Devis reçu
3
Commande passée
4
Paiement
5
Expédié
6
Livré
Voir les détails de la RFQ