LT1008IN8 - Precision Picoamp Op Amp | Analog Devices
Référence : LT1008IN8 ✓ ActifLT1008IN8 Présentation
An operational amplifier is an analog integrated circuit that amplifies the voltage difference between its non-inverting and inverting inputs while providing very high open-loop gain. The LT1008 belongs to the precision operational-amplifier category and, more broadly, to the signal-chain and analog IC hierarchy. Its unusually low bias current enables accurate sensing from high-impedance sources, sensors, transducers, and leakage-sensitive measurement circuits without adding substantial input-referred error.
The LT1008 combines picoampere bias currents maintained across the -55°C to 125°C temperature range with microvolt offset voltage, low offset drift, low voltage and current noise, and low power dissipation. According to the Analog Devices LT1008 datasheet, the amplifier can deliver 5 mA of load current while retaining high voltage gain. It also provides extremely high common-mode and power-supply rejection ratios, making it effective in systems where supply ripple or input-common-mode variation could otherwise degrade measurement accuracy.
The LT1008 is implemented as a bipolar precision amplifier. Its low bias current reduces error when the source impedance is high, while its precision reference and offset characteristics support stable null and calibration behavior over time and temperature. The amplifier is intended for general-purpose precision applications rather than high-speed signal conditioning, making stability and noise more important than slew rate or gain-bandwidth performance.
Typical uses include low-level sensor signal conditioning, electrochemical and biomedical instrumentation, photodiode amplifiers, precision current-to-voltage conversion, leakage measurement, strain-gauge bridges, and laboratory test equipment. Its low-noise and high-rejection characteristics are especially useful when the useful signal is small relative to the input offset or supply ripple.
For best performance, use suitable bypassing on the supply pins, keep input and feedback traces short, and avoid contamination or leakage pathways on high-impedance nodes. The offset specifications should be evaluated over the actual temperature range, and input protection must be designed to prevent excessive differential voltage or common-mode voltage. The IN8 suffix identifies the industrial-temperature PDIP package option, so board layout and thermal requirements should follow the package drawing rather than a surface-mount footprint.
This page consolidates the manufacturer's device information, distributor availability references, a precise package pinout, compatibility guidance, and practical design notes. It also distinguishes the only confirmed same-footprint alternative from functionally similar amplifiers that cannot be soldered directly into an existing PDIP-8 footprint.
Alternatives de remplacement direct pour LT1008IN8 — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.
LT1008CN8
✅ Remplacement direct ⚠️ Spécifications non vérifiées📋 Alternative de référence (hors catalogue)
LT1008IN8 Valeurs maximales et caractéristiques électriques
| Amplifier Type | Single precision operational amplifier |
| Number of Circuits | 1 circuit |
| Supply Voltage Range | ±3 V to ±18 V |
| Maximum Total Supply Voltage | 36 V |
| Input Offset Voltage | 320 µV maximum |
| Input Bias Current | 50 pA typical |
| Input Bias Current Temperature Range | Maintained from -55°C to 125°C |
| Input Voltage Noise Density | 7.5 nV/√Hz at 1 kHz |
| 0.1 Hz Noise Density | 22 nV/√Hz |
| Open-Loop Gain | 120 dB typical |
| Common-Mode Rejection Ratio | 120 dB typical |
| Power-Supply Rejection Ratio | 110 dB typical |
| Gain-Bandwidth Product | 800 kHz |
| Slew Rate | 0.11 V/µs |
| Output Drive Current | 5 mA |
| Plage de température de fonctionnement | -55°C to 125°C |
| Boîtier | 8-pin PDIP |
| Type de montage | Through-hole |
Configuration des broches de LT1008IN8
| Broche 1 | NC — Not connected |
| Broche 2 | - — Inverting input |
| Broche 3 | + — Non-inverting input |
| Broche 4 | V- — Negative power supply |
| Broche 5 | NC — Not connected |
| Broche 6 | OUT — Output |
| Broche 7 | V+ — Positive power supply |
| Broche 8 | NC — Not connected |
Applications typiques
LT1008IN8 convient pour 6 applications: High-Impedance Sensor Signal Conditioning, Photodiode Current-to-Voltage Conversion, Precision Strain-Gauge Bridge Amplification, Electrochemical and Biomedical Instrumentation, Precision Current-to-Voltage Measurement, Laboratory and Test-Instrument Front Ends.
High-Impedance Sensor Signal Conditioning
The LT1008IN8 fits high-impedance sensor front ends because its 50 pA typical input bias current limits the error introduced by the source and feedback impedances. That low leakage is especially valuable when sensor currents are picoampere-scale and the required measurement accuracy would otherwise be degraded by input bias. Place the amplifier close to the sensor connector, keep the summing node short, and use guarding where humidity or board contamination could create parallel leakage. The low 7.5 nV/√Hz voltage-noise density also helps preserve small-signal detail, although the circuit should avoid excessive bandwidth that could amplify high-frequency noise.
Recommandé
Photodiode Current-to-Voltage Conversion
The LT1008IN8 is appropriate for photodiode and phototransistor current measurements because picoampere input bias current reduces errors relative to the very small generated currents. In a transimpedance configuration, the feedback resistor converts photocurrent into voltage while the amplifier maintains low input voltage error across that resistor. Its 5 mA output-drive capability and low noise support practical signal levels, but the resistor value must balance conversion gain against bandwidth and stability. A guarded, contamination-free PCB layout is essential because surface leakage can rival the photodiode current itself.
Recommandé
Precision Strain-Gauge Bridge Amplification
The LT1008IN8 can amplify the small differential voltage produced by a strain-gauge bridge while rejecting supply variations and common-mode voltage. Its 120 dB typical common-mode rejection and 110 dB typical power-supply rejection reduce unwanted signals that could otherwise obscure the mechanical measurement. The 120 dB typical open-loop gain supports accurate closed-loop gain, while microvolt-level offset characteristics minimize output error. Designers should use stable low-temperature-coefficient feedback resistors, maintain balanced resistance networks, and provide local supply bypassing to preserve the benefit of the amplifier's rejection performance.
Recommandé
Electrochemical and Biomedical Instrumentation
The LT1008IN8 is well suited to electrochemical sensors and biomedical instrumentation where electrode currents can be extremely small and signal integrity depends on leakage control. Picoampere-scale input bias current limits bias-induced measurement error, while low voltage noise supports resolving small changes in sensor output. The extended -55°C to 125°C LT1008IN8 temperature grade is useful where environmental conditions vary substantially. PCB cleanliness, conformal coating strategy, connector insulation, and guarding should be reviewed as a complete system because external contamination can defeat the benefit of the low-leakage amplifier.
Recommandé
Precision Current-to-Voltage Measurement
The LT1008IN8 can measure small currents by applying a known sense resistor and amplifying the resulting voltage with high open-loop gain. Its 320 µV maximum input offset becomes a meaningful input-referred error when the measured current is small, so offset calibration and temperature drift should be included in the error budget. The low input bias current avoids additional error from the sense path, and 5 mA output drive permits useful range around the measurement node. Select resistor values carefully because large feedback values increase Johnson noise and can make PCB leakage significant.
Recommandé
Laboratory and Test-Instrument Front Ends
The LT1008IN8 fits precision laboratory measurement equipment requiring low noise, low offset, and low input leakage. Its 7.5 nV/√Hz voltage-noise density, 120 dB typical common-mode rejection, and 110 dB typical power-supply rejection help preserve accuracy when the source is small and the test bench introduces supply or ground disturbances. The 800 kHz gain-bandwidth product is adequate for many low-frequency precision measurements rather than wideband signal capture. Stable reference elements, low-leakage relays, clean connectors, and properly bypassed supplies remain essential to achieving the accuracy implied by the device specifications.
Recommandé
Récapitulatif des produits recommandés
Données de référence d'ingénierie pour LT1008IN8 — comparaison, recommandations de conception et informations de conformité.
Guide de sélection
Comparaison avec les alternatives
| Paramètre | Ce produit | LT1008CN8 |
|---|---|---|
| Brand | Analog Devices | Analog Devices |
| Package | PDIP-8 | PDIP-8 |
| Amplifier Type | Precision operational amplifier | Precision operational amplifier |
| Number of Circuits | 1 | 1 |
| Supply Voltage Range | ±3 V to ±18 V | ±3 V to ±18 V |
| Input Offset Voltage | 320 µV maximum | 320 µV maximum |
| Input Bias Current | 50 pA typical | 50 pA typical |
| Input Voltage Noise Density | 7.5 nV/√Hz at 1 kHz | 7.5 nV/√Hz at 1 kHz |
| Open-Loop Gain | 120 dB typical | 120 dB typical |
| Operating Temperature Range | -55°C to 125°C | -40°C to 85°C |
| Output Drive Current | 5 mA | 5 mA |
| Mounting Type | Through-hole | Through-hole |
Principaux différenciateurs
- Very low input bias for accurate high-impedance measurements (vs LT1008CN8)
- Extended industrial temperature operation (vs LT1008CN8)
- Precision offset and noise for small-signal amplification (vs LT1008CN8)
Notes de conception
Keep the inverting input and feedback component directly adjacent to pins 2 and 6, and route the non-inverting input on pin 3 away from supply, clock, and high-current traces. For high-impedance sources, shorten the input node, remove solder flux and contamination, and use a grounded guard where practical. PCB leakage can become comparable to the LT1008IN8's picoampere input bias current, so a clean board is part of the precision design rather than a manufacturing detail.
Place the supply-bypass capacitor close to pins 7 and 4 and provide a low-impedance ground return. Keep both supply rails within the ±3 V to ±18 V operating range and observe the 36 V maximum total supply voltage. Although the LT1008 has 110 dB typical power-supply rejection, that performance depends on clean local bypassing and a stable reference; excessive supply ripple or slow power-up can still create transient errors and possible saturation.
Do not choose an amplifier merely because its input offset is lower; verify input bias current, noise, common-mode range, output swing, supply range, and temperature grade. The LT1008IN8 is a precision, relatively low-bandwidth device with an 800 kHz gain-bandwidth product, so it should not be expected to replace a wideband amplifier. Conversely, a general-purpose op amp with acceptable offset may still introduce excessive leakage and noise in a picoampere measurement.
Account for input offset, offset drift, bias-current error, resistor tolerance, and temperature in the measurement uncertainty budget. With a feedback or sense resistance of R, the voltage error caused by 50 pA typical bias current is approximately 50 pA multiplied by R; for 1 GΩ, that is 50 µV. Use high-quality, stable resistors and consider input-offset calibration where the measurement resolution demands it.
Informations de conformité
The available manufacturer and distributor descriptions identify the device and its precision-amplifier characteristics but do not provide explicit compliance declarations.