LT1013IN8 - Dual Precision Op Amp, 5V/±15V | Analog Devices
Référence : LT1013IN8 ✓ ActifLT1013IN8 Présentation
An operational amplifier is an active analog signal-processing component that compares an inverting input with a non-inverting input and amplifies the voltage difference between them. The dual LT1013 belongs to the operational-amplifier hierarchy within analog ICs and linear amplifiers, providing two independent amplifier channels in one package. This integration reduces component count in instrumentation and measurement designs while preserving a conventional 8-pin industry-standard configuration.
The LT1013 is positioned for precision rather than high-speed or high-current applications. Its key benefits include low input offset voltage, low input bias current, low voltage noise, high open-loop gain, and the ability to operate from a single 5 V supply or from ±15 V. Analog Devices identifies battery-powered precision instrumentation, strain-gauge signal conditioners, thermocouple amplifiers, instrumentation-amplifier blocks, 4 mA-to-20 mA current-loop transmitters, multiple limit-threshold detectors, active filters, and multiple gain blocks as representative applications.
The dual architecture places two matched precision amplifier channels in one package. Each channel can be configured as an inverting amplifier, non-inverting amplifier, voltage follower, comparator-like threshold detector, or active-filter section. Input common-mode capability down toward ground is especially useful for sensor outputs that occupy the lower portion of the supply range. The operating-voltage envelope also permits legacy industrial and laboratory equipment to use the same amplifier topology with split supplies.
Typical deployments include bridge-amplifier inputs for strain gauges, low-voltage thermocouple conditioning, precision current-loop receivers, programmable gain blocks, and active analog filters. In a 5 V system, the amplifier can operate from one supply when the signal remains compatible with the input common-mode range. In instrumentation equipment with balanced analog signals, ±15 V operation provides additional headroom around ground and simplifies matching to legacy signal-chain circuitry.
Designers should verify input common-mode voltage, output swing, input bias-current effects, stability with the selected load, and noise performance at the intended signal bandwidth. Decoupling capacitors should be placed close to the supply pins, while sensitive-input routing should minimize leakage and stray capacitance. For source impedances with appreciable resistance, input bias current can create offset error, so resistor values and source resistance should be balanced where practical.
This product page combines the manufacturer application overview with package information, sourcing guidance, pin-level implementation details, and a parameter comparison focused on the LT1013IN8. It is intended to help engineers identify whether this dual precision amplifier, its lead-free ordering code, and its 8-pin PDIP implementation fit an instrumentation or signal-conditioning design.
Alternatives de remplacement direct pour LT1013IN8 — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.
LT1013CN8
✅ Remplacement direct ⚠️ Spécifications non vérifiées📋 Alternative de référence (hors catalogue)
LT1013IN8#PBF
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
LT1013ACN8
✅ Remplacement direct ⚠️ Spécifications non vérifiées📋 Alternative de référence (hors catalogue)
LT1013BCN8
✅ Remplacement direct ⚠️ Spécifications non vérifiées📋 Alternative de référence (hors catalogue)
LT1013IN8 Valeurs maximales et caractéristiques électriques
| Product Type | Dual precision operational amplifier |
| Number of Amplifier Circuits | 2 circuits |
| Supported Supply Configuration | Single 5 V or dual ±15 V |
| Single-Supply Voltage | 5 V |
| Dual-Supply Voltage | ±15 V |
| Input Common-Mode Capability | Extends to ground |
| Boîtier | 8-pin PDIP |
| Type de montage | Through-hole |
| Channel Count | 2 |
| Application Class | General-purpose precision amplifier |
| Signal Type | Analog voltage |
| Lead-Free Ordering Code | LT1013IN8#PBF |
Configuration des broches de LT1013IN8
| Broche 1 | OUT A — Channel A output |
| Broche 2 | -IN A — Channel A inverting input |
| Broche 3 | +IN A — Channel A non-inverting input |
| Broche 4 | V- — Negative supply connection |
| Broche 5 | +IN B — Channel B non-inverting input |
| Broche 6 | -IN B — Channel B inverting input |
| Broche 7 | OUT B — Channel B output |
| Broche 8 | V+ — Positive supply connection |
Applications typiques
LT1013IN8 convient pour 6 applications: Strain-Gauge Signal Conditioning, Thermouple Amplification, 4mA to 20mA Loop Conditioning, Precision Active Filtering, Battery-Powered Instrumentation, Threshold and Limit Detection.
Strain-Gauge Signal Conditioning
The LT1013IN8 fits strain-gauge bridge front ends because its dual precision channels can amplify small differential sensor signals and the input range extends toward ground. One channel can form the instrumentation gain stage while the other provides gain, buffering, or threshold support. The operating envelope of 5 V single supply or ±15 V dual supply allows the same family to address portable measurement systems and laboratory equipment. Verify bridge excitation voltage, input common-mode limits, input bias-current error, and output swing against the sensor impedance and mechanical measurement range before finalizing resistor values.
Thermouple Amplification
The LT1013IN8 is appropriate for low-level thermocouple conditioning because precision operation can support a high-gain amplifier while the input range extends to ground. Two channels permit a differential input stage followed by a second gain or filtering section, reducing the need for separate monolithic devices. The 5 V supply option suits compact battery-powered instrumentation, while ±15 V operation provides useful headroom for laboratory input stages. Confirm cold-junction compensation, polarity, common-mode behavior at the lowest expected thermocouple voltage, input offset, and the bandwidth required for the temperature measurement loop.
4mA to 20mA Loop Conditioning
The LT1013IN8 can condition industrial current-loop signals using its two precision amplifier channels for amplification, filtering, and active gain stages. The input capability extending toward ground is useful when processing signals referenced close to the lower supply rail, and ±15 V operation suits legacy transmitters and receivers. A practical implementation can use one channel as a transimpedance or difference stage and the other for active filtering or output buffering. Validate the loop input range, isolation boundaries, resistor accuracy, output compliance, noise bandwidth, and protection requirements for the installed transmitter.
Precision Active Filtering
The LT1013IN8 can implement precision active filters when the signal bandwidth is modest and component tolerances dominate circuit accuracy. Its two channels allow second-order sections in a continuous-time filter or separate low-pass and high-pass paths, while the choice between 5 V and ±15 V supplies supports different signal ranges. Input bias current, open-loop gain, gain-bandwidth behavior, and output-drive capability determine whether the circuit remains stable with the selected resistor and capacitor values. Simulate the complete filter with realistic tolerances before layout and verify noise performance across the intended measurement bandwidth.
Battery-Powered Instrumentation
The LT1013IN8 supports compact battery-powered instrumentation because it operates from a 5 V supply and includes two amplifier channels in one 8-pin PDIP package. The dual configuration can reduce board area by combining low-level amplification with a second gain, buffer, or filtering function. Input common-mode capability extending toward ground helps when the sensor output occupies the lower end of the supply range. Establish the complete power budget, including quiescent current and downstream loading, and verify offset, noise, input bias current, output swing, and wake-up behavior across battery voltage and temperature.
Threshold and Limit Detection
The LT1013IN8 is suitable for multiple limit-threshold detection because Analog Devices identifies this function as an LT1013 application and the package contains two independent channels. Each amplifier can compare a sensor signal against a reference, with one channel monitoring an upper limit and the other a lower limit. Precision offset behavior helps reduce threshold error, while the input range extending to ground supports low-level monitoring signals. Confirm input overvoltage protection, reference accuracy, output logic levels, propagation requirements, and whether noise near the threshold requires filtering or hysteresis.
Données de référence d'ingénierie pour LT1013IN8 — comparaison, recommandations de conception et informations de conformité.
Guide de sélection
Comparaison avec les alternatives
| Paramètre | Ce produit | LT1013CN8 | LT1013IN8#PBF | LT1013ACN8 | LT1013BCN8 |
|---|---|---|---|---|---|
| Package | 8-pin PDIP | 8-pin PDIP | 8-pin PDIP | 8-pin PDIP | 8-pin PDIP |
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Amplifier Channels | 2 | 2 | 2 | 2 | 2 |
| Product Class | Precision operational amplifier | Precision operational amplifier | Precision operational amplifier | Precision operational amplifier | Precision operational amplifier |
| Single-Supply Operation | 5 V | 5 V | 5 V | 5 V | 5 V |
| Dual-Supply Operation | ±15 V | ±15 V | ±15 V | ±15 V | ±15 V |
| Input Common-Mode Range | Extends to ground | Extends to ground | Extends to ground | Extends to ground | Extends to ground |
| Operating Temperature Grade | Industrial | Commercial | Industrial | Automotive | Extended temperature |
Principaux différenciateurs
- Single 5 V and ±15 V operating options (vs LT1013CN8)
- Lead-free ordering compatibility (vs LT1013CN8)
- Input operation extending toward ground (vs LT1013ACN8)
Notes de conception
Check the exact ordering suffix before substituting LT1013IN8, LT1013CN8, LT1013ACN8, or LT1013BCN8. The devices share the 8-pin PDIP format, but commercial, industrial, automotive, and extended-temperature grades have different operating limits. Confirm the pinout against the manufacturer package drawing and verify that the PCB footprint accommodates the PDIP lead spacing and row width.
Place the supply bypass capacitor close to pins 4 and 8 and return its ground connection directly to the analog ground reference. For instrumentation signals, keep input traces short and isolate them from switching nodes and high-current returns. Because source resistance converts input bias current into offset voltage, use practical resistor values and balance impedances where the circuit permits it.
Evaluate output swing at the minimum and maximum supply voltages and the highest operating temperature. A 5 V single-supply circuit does not provide symmetric output range around ground, so choose gain, reference level, and signal centering carefully. In a ±15 V circuit, verify that downstream protection devices and the selected package variant can tolerate the selected supply configuration.
Informations de conformité
The LT1013IN8#PBF ordering code identifies a lead-free finish. RoHS, REACH, halogen-free, and conflict-minerals declarations for the target ordering code require confirmation from the manufacturer product documentation.