MAX3243EAI+TG1Z - 3.3V RS-232 Transceiver | Analog Devices
Référence : MAX3243EAI+TG1Z ✗ Fin de vieMAX3243EAI+TG1Z Présentation
An RS-232 transceiver is an interface IC that converts logic-level signals into RS-232 line levels and converts incoming RS-232 signals back into logic-level voltages. It belongs to the transceiver class within interface ICs and ultimately to the broader semiconductor and wired-communications hierarchy. The MAX3243 combines three transmitters, five receivers, and an always-active receiver designed for external monitoring, reducing the number of separate interface devices required in multi-channel equipment.
Principal features include three powered drivers, five receiver channels, operation from a 3 V supply, automatic shutdown and wakeup functions, and enhanced ESD protection. The automatic power-control functions help a system reduce consumption when the communication port is idle, while the always-active receiver permits continuous monitoring of an external RS-232 connection. These functions are especially useful in industrial controllers, test equipment, and embedded systems that combine communication and low-power operating modes.
The MAX3243E family is built for bidirectional point-to-point serial links using the EIA/TIA-232 standard. Each transmitter provides the voltage swing required by an RS-232 receiver, and each receiver translates the bipolar line voltage into a compatible digital signal. The interface operates from the same 3 V to 5.5 V supply range used by many modern embedded processors, reducing the need for a separate high-voltage interface supply. Exact data-rate, slew-rate, propagation-delay, and channel-isolation limits should be taken from the manufacturer datasheet for the selected temperature and supply conditions.
Typical applications include multi-port RS-232 instrumentation, industrial serial controllers, data-acquisition equipment, point-of-sale terminals, and service interfaces for embedded systems. The five receivers are useful when the product must monitor more than one incoming RS-232 signal, while three transmitters support several outbound connections. In portable or industrial equipment, automatic shutdown and wakeup can help control current use when no active peer device is present on the bus.
PCB design should preserve the RS-232 interface’s intended impedance and noise behavior, with short connections between the transceiver, protection network, connector, and ground structure. Place the interface-supply decoupling capacitor close to the device and route high-current return paths away from sensitive logic. Before a board revision, verify every signal, enable, and supply connection against the manufacturer pin-description table for the 28-pin SSOP variant.
This page combines the manufacturer’s family-level capabilities with exact package and ordering information for MAX3243EAI+TG1Z, then adds application guidance, design checks, and compatible family references. It is intended to help engineers confirm supply compatibility, channel count, package reuse, and the design implications of automatic RS-232 shutdown before releasing a PCB or production build.
Alternatives de remplacement direct pour MAX3243EAI+TG1Z — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.
Variantes de cette série
Modèles de la même série directement compatibles avec MAX3243EAI+TG1Z (même facteur de forme et même empreinte) — différant par Product Type, Supply Voltage Range, ESD Protection, Maximum Data Rate, Shutdown Supply Current.
MAX3243EEAI+TG1Z
✅ Remplacement directContactez-nous pour le prix
Voir la fiche technique →MAX3243EAI+
✅ Remplacement directContactez-nous pour le prix
Voir la fiche technique →MAX3243EAI+G1Z
✅ Remplacement directContactez-nous pour le prix
Voir la fiche technique →MAX3243EEUI+T
✅ Remplacement directContactez-nous pour le prix
Voir la fiche technique →MAX3243EAI+TG1Z Spécifications
| Product Type | RS-232 transceiver interface IC |
| Number of Transmitters | 3 channels |
| Number of Receivers | 5 channels |
| Supply Voltage Range | +3 V to +5.5 V |
| Supply Current Rating | 1 A |
| Communication Standard | EIA/TIA-232 |
| Supported Protocol | V.28 and V.24 |
| Power Management | Automatic shutdown and wakeup |
| ESD Protection | Enhanced electrostatic discharge protection |
| Always-Active Receiver | 1 receiver channel |
| Boîtier | 28-pin SSOP |
| Type de montage | Surface mount |
Guide de configuration des broches du MAX3243EAI+TG1Z 28-pin ssop
Configuration des broches du MAX3243EAI+TG1Z (boîtier 28-pin ssop). La numérotation des broches, les fonctions et les schémas de connexion sont définis dans la fiche technique du fabricant. Consultez-la pour l'empreinte exacte et les directives de soudage.
Aucune donnée de brochage détaillée disponible pour MAX3243EAI+TG1Z.
Consultez la fiche technique pour la configuration complète des broches.
Applications typiques
MAX3243EAI+TG1Z convient pour 6 applications: Industrial Serial Controllers, Data-Acquisition Equipment, Point-of-Sale Terminals, Test and Measurement Systems, Embedded Service Interfaces, Communication Port Concentrators.
Industrial Serial Controllers
The MAX3243EAI+TG1Z fits industrial serial controllers that need several RS-232 ports around a single embedded processor. Its three transmitters and five receivers provide more channel capacity than a basic one-driver, one-receiver transceiver, while the +3 V to +5.5 V supply range supports common embedded rails. Automatic shutdown and wakeup can reduce power use when the controller is idle. The enhanced ESD protection is useful near field-accessible equipment, although a properly engineered external protection and grounding strategy remains necessary.
Recommandé
Data-Acquisition Equipment
Data-acquisition equipment can use the MAX3243EAI+TG1Z to connect a controller to multiple RS-232 instruments and status inputs. Three transmitters support separate outbound commands, while five receivers can monitor responses or external equipment conditions. Operating from +3 V to +5.5 V simplifies integration with low-voltage control electronics, and the always-active receiver supports external monitoring. Engineers should confirm data-rate and propagation-delay limits for the shortest sampling interval and include connector-level surge protection for external cabling.
Recommandé
Point-of-Sale Terminals
Point-of-sale terminals can use the MAX3243EAI+TG1Z for a concentrated set of RS-232 peripheral connections. The five receivers allow several peripheral status signals to be monitored, while the three transmitters can address multiple devices or service connections. Its 28-pin SSOP package supports compact board layouts, and automatic shutdown and wakeup helps manage power when peripherals are inactive. Firmware should use deterministic timeouts and line-state checks because automatic wakeup does not replace protocol handshaking or correct RS-232 signal-state management.
Recommandé
Test and Measurement Systems
MAX3243EAI+TG1Z is suitable for test and measurement systems that need several RS-232 command outputs and monitoring inputs. The three transmitters can drive separate instruments, and the five receivers can collect responses, interlocks, or remote status signals without requiring one transceiver per direction. Its +3 V to +5.5 V operation is compatible with modern test-controller logic. For bench or field connections, combine the interface with appropriately rated protection, a controlled ground reference, and verified baud-rate margin for each supported instrument.
Recommandé
Embedded Service Interfaces
The MAX3243EAI+TG1Z can consolidate service and diagnostic connections in an embedded controller. Multiple transmitter channels support distinct service ports, while the receiver channels can monitor external service equipment or configuration tools. Automatic shutdown and wakeup is especially useful for systems that remain powered while most communications ports are idle. Because the device shares a 28-pin SSOP footprint with close family variants, a qualified redesign can preserve PCB routing when the exact ordering suffix and temperature requirements remain compatible.
Recommandé
Communication Port Concentrators
MAX3243EAI+TG1Z is appropriate for communication port concentrators that aggregate legacy RS-232 links onto one embedded controller. Its three transmitters and five receivers provide enough parallel connectivity for routing, monitoring, or configuration equipment without distributing the interface across many packages. The always-active receiver enables continuous external monitoring, while automatic shutdown and wakeup supports power-conscious operation. Design the interconnect so idle RS-232 lines do not create excessive ground current, and validate every channel against the system’s selected baud rate.
Recommandé
Récapitulatif des produits recommandés
Données de référence d'ingénierie pour MAX3243EAI+TG1Z — comparaison, recommandations de conception et informations de conformité.
Guide de sélection
Comparaison avec les alternatives
| Paramètre | Ce produit | MAX3243EEAI+TG1Z | MAX3243EAI+ | MAX3243EAI+G1Z | MAX3243EEUI+T |
|---|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Package | 28-pin SSOP | 28-pin SSOP | 28-pin SSOP | 28-pin SSOP | 28-pin SSOP |
| Transmitter Count | 3 | 3 | 3 | 3 | 3 |
| Receiver Count | 5 | 5 | 5 | 5 | 5 |
| Supply Voltage Range | +3 V to +5.5 V | +3 V to +5.5 V | +3 V to +5.5 V | +3 V to +5.5 V | +3 V to +5.5 V |
| Automatic Shutdown and Wakeup | Supported | Supported | Supported | Supported | Supported |
| ESD Protection | Enhanced | Enhanced | Enhanced | Enhanced | Enhanced |
Principaux différenciateurs
- Three transmitters and five receivers in one interface (vs MAX3221E)
- Consolidates multiple monitoring inputs (vs MAX3223E)
- Automatic shutdown and wakeup support (vs MAX3243EEAI+TG1Z)
Notes de conception
Place the interface-supply bypass capacitor immediately between the MAX3243EAI+TG1Z supply and ground pins. Keep the loop formed by the capacitor, device, and ground return as short as practical. Route RS-232 driver outputs directly toward the connector or protection network, and avoid sharing narrow high-current paths with sensitive analog or digital signals. This separation helps prevent supply transients and return currents from coupling into nearby logic.
Do not substitute a MAX3221E or MAX3223E pinout for the MAX3243EAI+TG1Z without a complete footprint and function review; those family members have different channel counts and may use different packages. Likewise, confirm that the exact TG1Z ordering variant satisfies the required temperature grade. After installation, verify transmitter polarity, receiver input assignments, shutdown behavior, and every supply pin against the manufacturer’s 28-pin SSOP pin-description table.
Keep the RS-232 connector, external protection components, and transceiver on a controlled signal path, with a low-impedance ground reference between the interface circuit and connector shell. Where the port connects to external cabling, use protection components selected for the required surge and ESD environment. Treat enhanced on-chip ESD protection as one layer of the solution rather than a substitute for correctly rated external protection, chassis grounding, and cable routing.
Informations de conformité
The MAX3243EAI+TG1Z is a commercial RS-232 interface IC, so AEC-Q100 qualification is not applicable. RoHS, REACH, lead-free, halogen-free, and conflict-minerals declarations require confirmation from the manufacturer or the applicable compliance documentation.