An octal counter is a sequential digital-logic component that advances through a fixed sequence of states when driven by clock transitions. The MC14022B family uses a four-stage Johnson counter followed by an integrated decoder. A Johnson counter circulates a defined pattern through four internal stages, while the decoder converts that pattern into eight mutually timed output signals. Within the broader semiconductor hierarchy, the device belongs to the counters and dividers category of CMOS logic ICs.
The primary features of the MC14022BD include eight decoded outputs, positive-edge triggering, and spike-free output behavior. Its 3 V to 18 V operating range allows use in both lower-voltage 5 V systems and conventional 15 V industrial logic environments. The four-stage counter provides the basis for dividing an input frequency into eight output periods, while the built-in code converter simplifies implementation compared with a separate binary counter and decoder arrangement.
Internally, the part combines four Johnson-counter stages with decoding logic. Each decoded output is normally low and becomes high only during its assigned octal time period. The outputs change on the positive-going edge of the clock pulse, making edge polarity an essential consideration when cascading multiple counters or synchronizing the circuit with other positive-edge-triggered logic. The design supports cascaded frequency division and ordered pulse generation without requiring an external binary-to-octal decoder.
Typical applications include divide-by-eight clock generation, programmable timing sequences, industrial control sequencing, digital waveform generation, and phase-distribution circuits. The device can also serve as a compact state decoder when a system requires eight outputs corresponding to successive input-clock intervals. In cascaded arrangements, multiple MC14022BD devices can create longer timing sequences or additional frequency divisions while retaining a consistent positive-edge operating model.
Designers should account for output rise and fall times, supply decoupling, and clock-signal integrity when operating near the upper frequency capability of the device. Place the decoupling capacitor close to the supply pins and route the clock away from output lines to avoid unintended coupling. Because the outputs change on the positive-going clock edge, downstream circuitry should use compatible triggering conventions or deliberate inversion where required.
This page combines the MC14022BD device description with practical design guidance, verified source links, application-focused engineering context, and a structured comparison of compatible family members. It also organizes sourcing information, compliance fields, package details, and technical search terms to help engineers evaluate the MC14022BD for counter, divider, timing, and sequencing designs.
Alternatives de remplacement direct pour MC14022BD — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.
MC14022BDG
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
MC14022BDR2
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
MC14022BDEBS
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
MC14022BD Valeurs maximales et caractéristiques électriques
| Counter Type | 4-stage Johnson octal counter with built-in code converter |
| Number of Output States | 8 states |
| Counter Elements | 1 element |
| Counter Width | 4 bit |
| Clock Edge | Positive edge |
| Supply Voltage Range | 3 V to 18 V |
| Configuration de sortie | 8 decoded outputs |
| Output Transition Edge | Positive-going clock edge |
| Output Behavior | Spike-free decoded outputs |
| Initial Output State | Normally low |
| Boîtier | 16-SOIC, 0.154 in (3.90 mm) width |
| Type de montage | Surface mount |
| Logic Family | CMOS counter |
Guide de configuration des broches du MC14022BD 16-soic, 0.154 in (3.90 mm) width
Configuration des broches du MC14022BD (boîtier 16-soic, 0.154 in (3.90 mm) width). Ce circuit intégré numérique comprend des GPIO, des interfaces de communication (UART, SPI, I2C) et des broches d'alimentation. Consultez la fiche technique du fabricant pour les fonctions alternatives des broches et les options de configuration. Indispensable pour la conception de systèmes embarqués et la conception de circuits imprimés.
Aucune donnée de brochage détaillée disponible pour MC14022BD.
Consultez la fiche technique pour la configuration complète des broches.
Applications typiques
MC14022BD convient pour 6 applications: Divide-by-Eight Clock Generation, Digital Timing Sequence Control, Industrial Step Sequencing, Waveform and Pulse Pattern Generation, Frequency Division and Cascaded Counters, Instrumentation and Measurement Control.
Divide-by-Eight Clock Generation
The MC14022BD is well suited to divide-by-eight clock generation because its four-stage Johnson counter and built-in decoder produce eight ordered output periods from one positive-edge clock. According to the manufacturer datasheet, the decoded outputs change on the rising clock edge and are designed to avoid output spikes. This makes the 16-SOIC device useful when a downstream circuit requires several phase-related timing signals rather than only a single divided square wave. Designers should confirm the required operating frequency, output drive, and cascade timing against the electrical characteristics before fixing the clock rate.
Recommandé
Digital Timing Sequence Control
The eight decoded outputs of the MC14022BD can represent successive portions of a clock cycle, making the device useful for deterministic timing-sequence control. Each output is normally low and asserts only during its designated octal interval, while transitions occur on the positive-going clock edge. Compared with a binary counter followed by a separate decoder, the integrated 16-SOIC implementation reduces package count and simplifies board routing. Logic should be designed around the specified edge polarity so that connected state machines do not interpret the decoded sequence differently.
Recommandé
Industrial Step Sequencing
In industrial equipment, the MC14022BD can turn a system clock into eight ordered output intervals for step sequencing, actuator timing, or repeatable control phases. Its 3 V to 18 V operating range supports common logic supply levels, and the built-in Johnson-to-octal decoding avoids the component count of a separate counter and decoder. The normally-low output convention provides a defined inactive state between asserted intervals. For machinery applications, add galvanic isolation, drive circuitry, and safety controls as required; the counter is a timing element rather than a power driver.
Recommandé
Waveform and Pulse Pattern Generation
The MC14022BD can generate an ordered sequence of decoded pulses because each of its eight outputs corresponds to a defined octal time period. This arrangement is useful in test equipment, signal-generation modules, and periodic control systems that require more than one phase from a compact counter. The manufacturer describes the Johnson design as providing high-speed operation and spike-free outputs, reducing unwanted transients in the decoded pattern. Confirm output rise and fall times in the datasheet and preserve adequate clock and supply routing to maintain deterministic behavior.
Recommandé
Frequency Division and Cascaded Counters
The MC14022BD can divide a periodic input into eight decoded intervals and can participate in cascaded timing chains that require longer cycles or additional outputs. Positive-edge operation provides a consistent clocking model when multiple counters are interconnected, provided propagation delays and clock-edge compatibility are checked. The 3 V to 18 V range allows common industrial logic rails, while the 16-SOIC package limits board area compared with multiple discrete decoding stages. Cascaded designs should include a defined reset sequence and verify worst-case timing across all counter and feedback paths.
Recommandé
Instrumentation and Measurement Control
The MC14022BD can establish repeatable acquisition, measurement, or calibration intervals by supplying eight ordered timing windows from a master clock. Its decoded outputs are normally low and assert one at a time according to the octal sequence, simplifying multiplexer drive or timing-enable generation. The integrated counter and code converter also reduce the number of external logic packages in compact instrumentation. Designers should synchronize control signals to the rising clock edge and evaluate ground bounce, clock routing, and supply decoupling for high fan-out loads.
Recommandé
Récapitulatif des produits recommandés
Données de référence d'ingénierie pour MC14022BD — comparaison, recommandations de conception et informations de conformité.
Guide de sélection
Comparaison avec les alternatives
| Paramètre | Ce produit | MC14022BDG | MC14022BDR2 | MC14022BDEBS |
|---|---|---|---|---|
| Package | 16-SOIC | 16-SOIC | 16-SOIC | 16-SOIC |
| Brand | onsemi | onsemi | onsemi | onsemi |
| Counter Architecture | 4-stage Johnson octal counter | 4-stage Johnson octal counter | 4-stage Johnson octal counter | 4-stage Johnson octal counter |
| Counter Width | 4 bit | 4 bit | 4 bit | 4 bit |
| Clock Edge | Positive edge | Positive edge | Positive edge | Positive edge |
| Supply Voltage Range | 3 V to 18 V | 3 V to 18 V | 3 V to 18 V | 3 V to 18 V |
| Decoded Outputs | 8 outputs | 8 outputs | 8 outputs | 8 outputs |
| Output Behavior | Spike-free decoded outputs | Spike-free decoded outputs | Spike-free decoded outputs | Spike-free decoded outputs |
| Output Transition | Positive-going clock edge | Positive-going clock edge | Positive-going clock edge | Positive-going clock edge |
Principaux différenciateurs
- Integrated Johnson counter and octal decoder (vs MC14022BCPG)
- Eight individually decoded timing outputs (vs A binary counter with external decoding)
- Spike-free Johnson-counter output behavior (vs MC14022BDG)
Notes de conception
Place the supply-decoupling capacitor close to the MC14022BD power and ground pins, and keep the clock route short and isolated from the eight decoded outputs. The positive-going clock edge causes several decoded outputs to change state around the same timing event, so inductive and capacitive coupling on clock or output traces can create unwanted transitions in downstream logic.
Design cascaded counters around a consistent positive-edge clock convention. Check propagation delay, output transition time, and clock-to-output timing in the manufacturer datasheet before selecting the maximum operating frequency. At high fan-out, use short traces, a ground reference, and buffered clock distribution rather than relying on a general-purpose output to drive multiple counter inputs.
Do not treat the decoded outputs as an ordinary binary count. The MC14022BD generates eight decoded, mutually timed outputs whose transitions occur on the positive-going clock edge. Reset-state behavior, active levels, and clock polarity should therefore be confirmed in the pin-description and timing sections before connecting outputs to latches, relays, or firmware-controlled sequencing logic.
Informations de conformité
The MC14022B manufacturer datasheet is the technical source for the counter architecture, supply range, output behavior, and package. RoHS, REACH, lead-free, halogen-free, and conflict-minerals status require confirmation from the current manufacturer product or material documentation.