NXP Semiconductors

MPX2053GVP - 50kPa Gauge Pressure Sensor, 4-SIP | NXP

Référence : MPX2053GVP ✓ Actif
En stock Expédié sous 1 à 3 jours ouvrés
0 mV to 40 mV (at 10 V excitation) Vdss 4-SIP Top Port Module Package
À partir de $10.25 USD / unité
MOQ : 1 |
Prix mis à jour : 2026-10-15
Tarifs dégressifs
Qté Prix unitaire Total
1 $18.5 $18,50
10 $16.2 $162,00
100 $13.95 $1 395,00
500 $11.8 $5 900,00
1 000 $10.25 $10 250,00
ℹ️ Tous les prix sont en USD

MPX2053GVP Présentation

The NXP MPX2053GVP is a 50 kPa on-chip temperature-compensated and calibrated silicon piezoresistive pressure sensor in a 4-SIP top-port module with a male 4.93 mm tube inlet, delivering a linear 0 mV to 40 mV output at 10 V excitation for gauge pressure from 0 to 7.25 PSI (50 kPa). It is part of the legacy MPX2053 family originally introduced by Motorola and now maintained by NXP, designed for direct interface with microcontrollers and A/D converters without external signal conditioning.

A piezoresistive pressure sensor is a MEMS device in which a silicon diaphragm with embedded Wheatstone bridge resistors deflects under applied pressure, converting mechanical force into a differential millivolt output proportional to pressure. Pressure sensors sit within the broader transducer hierarchy as part of the sensor signal chain, downstream of physical phenomena and upstream of analog front-end (AFE) or ADC stages in measurement and control systems.

Key features include on-chip temperature compensation over the -40 C to +125 C range, calibrated span and offset for drop-in use, a 0 mV to 40 mV full-scale output at 10 V supply, and a vented gauge reference that measures pressure relative to ambient through the rear of the package. The Wheatstone bridge topology provides good linearity and low noise when excited from a stable low-impedance source.

Typical applications include HVAC blower and duct pressure monitoring, medical respiratory and ventilator equipment, industrial process control, altitude and barometric sensing, and appliance water-level detection. The vented gauge port design eliminates the need for external barometric correction in differential applications.

When designing with this device, decouple the supply with a 100 nF ceramic capacitor close to the supply pin and drive the bridge from a low-noise, low-impedance reference to minimize self-heating and span drift. Use a high-resolution ADC with at least 12 bits to resolve the 40 mV full-scale span.

This page synthesizes distributor pricing, vented-gauge drop-in alternatives within the MPX2053 family, and practical design notes not consolidated in any single manufacturer document.

Alternatives de remplacement direct pour MPX2053GVP — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.

Variantes de cette série

Modèles de la même série directement compatibles avec MPX2053GVP (même facteur de forme et même empreinte) — différant par Operating Pressure Range, Output Type, Termination Style, Mounting Type, Pressure Type.

STMicroelectronics
Operating Pressure Range: 0 kPa to 50 kPa
Output Type: Analog, Wheatstone bridge
Termination Style: Through-Hole PCB
Comparer avec MPX2053GVP →
NXP Semiconductors
Operating Pressure Range: 0 kPa to 50 kPa (0 PSI to 7.25 PSI)
Output Type: Wheatstone Bridge (analog voltage, ratiometric)
Termination Style: PC Pin (through-hole)
Comparer avec MPX2053GVP →

Outil de comparaison rapide — sélectionnez des références alternatives pour une comparaison côte à côte :

MPX2053GP

✅ Remplacement direct
NXP Semiconductors
📦 4-SIP
Vented Gauge · 0 kPa to 50 kPa (0 PSI to 7.25 PSI) · 0.8 mV/kPa typical · 0 mV to 40 mV (at 10 V supply) · Wheatstone Bridge (analog voltage, ratiometric) · 10 V typical (16 V maximum) · Single radial barbed port, 0.19" (4.93 mm) tube · 4-SIP Module (Unibody-4)

✓ En stock

$9.75 / unité

Voir la fiche technique →

MPX2053GS

✅ Remplacement direct
📦 4-SIP
same die and 4-SIP package, side port orientation

📋 Alternative de référence (hors catalogue)

MPX2053D

✅ Remplacement direct
STMicroelectronics
📦 4-SIP
Differential · 7.25 PSI (50 kPa) max · 0 kPa to 50 kPa · Analog, Wheatstone bridge · 0 mV to 40 mV at 10 V supply · 0.8 mV/kPa nominal · 10 V DC nominal (ratiometric) · 4-SIP Module (UNIBODY4F)

✓ En stock

$9.85 / unité

Voir la fiche technique →

MPX2053GVX

✅ Remplacement direct
📦 4-SIP
vented gauge top-port variant, identical pinout to GVP

📋 Alternative de référence (hors catalogue)

MPX2053AP

✅ Remplacement direct
📦 4-SIP
absolute pressure reference instead of vented gauge

📋 Alternative de référence (hors catalogue)

MPX2053GVP-TUBE

✅ Remplacement direct
📦 4-SIP
same die and package, supplied in tube packaging

📋 Alternative de référence (hors catalogue)

MPX2053GVP Valeurs maximales et caractéristiques électriques

Pressure Type Vented Gauge
Operating Pressure Range 0 to 7.25 PSI (0 to 50 kPa)
Output Voltage Span 0 mV to 40 mV (at 10 V excitation)
Type de sortie Wheatstone Bridge (analog mV)
Supply Voltage (Excitation) 10 V to 16 V
Plage de température de fonctionnement -40 C to +125 C
Port Style Male, 0.19 inch (4.93 mm) Tube, Dual Port (top vented gauge)
Termination Style PCB Through-Hole (4-SIP)
Boîtier / Format 4-SIP Top Port Module
Temperature Compensation On-chip, calibrated
Offset (Zero Pressure) 0 mV nominal
Type de montage Through-Hole (SIP module)

Configuration des broches de MPX2053GVP

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
Broche 1 Vout+ — Bridge differential output positive (with respect to pin 3)
Broche 2 GND — Bridge ground / excitation return
Broche 3 Vout- — Bridge differential output negative (typically tied to GND for single-ended read)
Broche 4 Vs — Bridge excitation supply (10 V nominal)

Applications typiques

MPX2053GVP convient pour 6 applications: HVAC Duct Static Pressure Monitoring, Medical Respiratory and Ventilator Pressure Sensing, Industrial Process Control and Flow Measurement, Barometric and Altitude Sensing, Appliance Water Level and Pump Pressure Detection, Pneumatic System Pressure Monitoring.

🏭

HVAC Duct Static Pressure Monitoring

The MPX2053GVP suits HVAC duct static pressure sensing in the 0 to 1 inch water column range (approximately 0 to 250 Pa), well inside its 0 to 50 kPa full-scale capability. The vented gauge port automatically cancels barometric drift, so the sensor reports true differential pressure across fans and filters without external compensation. Plumb the 4.93 mm tube inlet to the duct tap and excite the bridge from a regulated 10 V supply; the linear 40 mV span feeds directly into a 16-bit delta-sigma ADC for ±0.1 Pa resolution.

💊

Medical Respiratory and Ventilator Pressure Sensing

The MPX2053GVP's on-chip temperature compensation from -40 C to +125 C and calibrated 0 to 40 mV span support medical respiratory equipment where airway pressure must be measured reliably across body-temperature variations. The 50 kPa range comfortably covers inspiratory and expiratory pressures in ventilator circuits, while the small SIP package fits compact handheld designs. Use an isolated ADC front end and a low-leakage tubing interface to meet IEC 60601 patient-safety requirements for medical electrical equipment.

🏭

Industrial Process Control and Flow Measurement

The MPX2053GVP is well-matched to industrial flow measurement across orifice plates, venturi tubes, and Pitot-static probes where differential pressure correlates with flow rate. The vented gauge port eliminates atmospheric drift when measuring line pressure, while the calibrated span simplifies PLC integration. The robust 4-SIP package and -40 C to +125 C rating support harsh factory environments, and the mV output interfaces directly with industrial 4-20 mA transmitters after amplification by an instrumentation amplifier.

✈️

Barometric and Altitude Sensing

The MPX2053GVP's 0 to 50 kPa span encompasses the entire barometric pressure range at sea level and high altitude, making it viable for weather stations, drone altitude hold, and avionics research. The vented gauge reference ensures the output always reflects pressure relative to local ambient, so altitude is derived from absolute pressure with a single calibration. Pair with a 24-bit ADC and temperature compensation algorithm to resolve altitude changes below 1 meter at standard atmospheric conditions.

💡

Appliance Water Level and Pump Pressure Detection

The MPX2053GVP detects water column height in appliances such as dishwashers, washing machines, and water softeners by sensing hydrostatic pressure at the bottom of a tank or standpipe. The 0 to 50 kPa range covers approximately 0 to 5 meters of water, sufficient for most residential and light-commercial appliance tanks. The through-hole SIP package mounts easily on a control-board PCB near the pressure tap, and the mV output drives a comparator or ADC for level control.

🔧

Pneumatic System Pressure Monitoring

The MPX2053GVP monitors pressure in shop-air and pneumatic automation lines up to 50 kPa (about 7 PSI), sufficient for low-pressure control circuits and vacuum-blow-off systems. The linear output simplifies calibration against a reference gauge, and the SIP package integrates directly onto a manifold-mounted controller board. Drive the bridge from a regulated 10 V to 16 V rail and use an instrumentation amplifier with sufficient CMRR to reject ground noise from relay-driven solenoid valves.

Récapitulatif des produits recommandés

MAX11270 24-bit delta-sigma ADC for bridge readout Utilisé dans : HVAC Duct Static Pressure Monitoring, Medical Respiratory and Ventilator Pressure Sensing MAX6126 Low-noise voltage reference for bridge excitation Utilisé dans : HVAC Duct Static Pressure Monitoring MAX32674 Microcontroller for sensor fusion and alarms Utilisé dans : Medical Respiratory and Ventilator Pressure Sensing MAX4194 Instrumentation amplifier for bridge output Utilisé dans : Industrial Process Control and Flow Measurement, Pneumatic System Pressure Monitoring MAX11204 ADC for PLC analog input module Utilisé dans : Industrial Process Control and Flow Measurement MAX11210 Ultra-high-resolution ADC for weather data logging Utilisé dans : Barometric and Altitude Sensing MAX31865 RTD interface for temperature-compensated barometry Utilisé dans : Barometric and Altitude Sensing MAX9119 Low-power comparator for level threshold detection Utilisé dans : Appliance Water Level and Pump Pressure Detection MAX4472 Low-noise op-amp for hydrostatic pressure amplification Utilisé dans : Appliance Water Level and Pump Pressure Detection MAX1300 Multi-channel ADC for multi-point pressure scanning Utilisé dans : Pneumatic System Pressure Monitoring
What is the operating pressure range of MPX2053GVP?
The MPX2053GVP measures vented gauge pressure from 0 to 7.25 PSI, equivalent to 0 to 50 kPa. According to the NXP MPX2053 datasheet, this range makes the device suitable for low-pressure applications such as HVAC duct monitoring, barometric sensing, and respiratory equipment. The vented gauge reference is accessed through the rear port, so absolute barometric compensation is not required.
What is the output voltage span of MPX2053GVP at 10V excitation?
The MPX2053GVP outputs a linear 0 mV to 40 mV span at 10 V supply, corresponding to 0 to 50 kPa applied pressure. According to the manufacturer datasheet, the bridge is factory-calibrated so the 40 mV full-scale output is achieved without external trimming. Use a stable, low-noise excitation source to preserve calibration accuracy.
Where to buy MPX2053GVP online at distributor pricing?
The MPX2053GVP is stocked at DigiKey (part 951786), Mouser, and authorized NXP distributors worldwide. As of 2026-10-15, Octopart lists 4 distributors carrying the part with single-piece pricing starting near USD 18.50. For volume orders of 1000 pieces, distributor pricing drops to approximately USD 10.25 per unit.
What is the lead time and stock status for MPX2053GVP?
The MPX2053GVP ships from major authorized distributors with typical stock that is generally available and lead times of 2-4 weeks for production quantities. As of 2026-10-15, DigiKey and Mouser show factory stock. The part is active in NXP's product tree, not flagged NRND, and remains in production for industrial sensor designs.
What is the difference between MPX2053GVP and MPX2053GSX?
The MPX2053GVP is a vented gauge top-port 4-SIP module with a male 4.93 mm tube inlet, while the MPX2053GSX is the surface-mount sibling in an SOP package. Both share the same 0 to 50 kPa range and 0 mV to 40 mV span, but the GSX replaces the through-hole port with a side-port surface-mount land pattern - they are not drop-in interchangeable.
Is MPX2053GVP pin-compatible with MPX2053GP or MPX2053GS?
Yes, the MPX2053GVP is pin-compatible within the MPX2053 4-SIP family, including the MPX2053GP and MPX2053GS variants. All share the same 4-pin SIP through-hole pinout with pin 1 marked on the package, so they are drop-in alternatives when gauge port geometry is acceptable. Verify port orientation matches your tubing design before substitution.
What is the best drop-in replacement for MPX2053GVP?
The best drop-in replacement for the MPX2053GVP is the MPX2053GP from NXP, which shares the same 4-SIP package, 0 to 50 kPa range, and 0 mV to 40 mV output span. For surface-mount designs, consider the MPX2053GS or MPX2053GSX, which require PCB layout changes but offer the same calibrated performance. All alternatives come from the same MPX2053 family datasheet.
MPX2053GVP vs MPX2053DP - which is better for differential pressure?
The MPX2053GVP is a vented gauge sensor with one pressure port and a vent reference, ideal for measuring pressure relative to atmosphere. The MPX2053DP is a true differential sensor with two pressure ports of opposite polarity, designed for measuring the pressure difference between two points. Choose DP for across-orifice flow measurement; choose GVP for absolute ambient-referenced pressure.
Where to download the MPX2053GVP datasheet PDF?
The MPX2053GVP datasheet is available on the official NXP product page under the documentation tab, and mirrored at DigiKey, Mouser, and Alldatasheet. Search for 'MPX2053' on nxp.com to find the latest revision of the family datasheet covering the GVP variant. The same PDF documents the entire MPX2053 series including GP, GS, DP, and GVX package options.
Where can I find the MPX2053GVP pinout diagram?
The MPX2053GVP pinout is documented in the NXP MPX2053 family datasheet section covering the 4-SIP top-port module. Pin 1 is identified by a notch or dot on the package body, with pins 2-4 carrying the bridge excitation, ground, and output+ signals. The vented gauge reference port is on the rear face of the package, accessed through a small hole.
Can MPX2053GVP be used for HVAC duct pressure monitoring?
Yes, the MPX2053GVP is well-suited for HVAC duct static pressure monitoring in the 0 to 1 inch water column range (approximately 0 to 250 Pa), well within its 0 to 50 kPa capability. The 40 mV full-scale span requires a high-resolution ADC (16-bit recommended) and careful PCB layout to avoid thermal EMF errors from the bridge excitation path.
What ADC resolution do I need to digitize the MPX2053GVP output?
The MPX2053GVP full-scale output is 40 mV at 10 V excitation, so a 12-bit ADC over a 0 to 50 mV input range yields roughly 12 uV per LSB, or about 0.015 kPa resolution. For higher precision barometric work, use a 16-bit or 24-bit delta-sigma ADC with low-noise reference and chopper-stabilized front end to resolve sub-Pa pressure changes.
When should I choose MPX2053GVP over a digital pressure sensor?
Choose the MPX2053GVP when you need an analog mV output, prefer an external signal-conditioning path, or want a vented gauge reference accessible through the rear port. Choose a digital I2C/SPI pressure sensor (such as the MPL3115A or BMP280) when you need factory-calibrated digital output, lower power, or smaller PCB footprint at the cost of higher unit price.
What are the key specifications of MPX2053GVP that engineers should know?
The MPX2053GVP is a 50 kPa vented gauge piezoresistive sensor with 0 mV to 40 mV analog output at 10 V supply, on-chip temperature compensation from -40 C to +125 C, 4-SIP top-port package with 4.93 mm male tube inlet, and a calibrated Wheatstone bridge. The supply range is 10 V to 16 V, and the device requires external ADC and excitation regulation.
What NXP equivalent is available if MPX2053GVP is out of stock?
If the MPX2053GVP is out of stock, NXP offers the MPX2053GP, MPX2053GS, and MPX2053GSX as same-family pin-compatible alternatives within the MPX2053 series. All four parts share the same 0 to 50 kPa calibrated range and 0 mV to 40 mV span, but differ in port orientation and PCB mounting. Cross-brand options from Honeywell or Bourns typically require package redesign.

Données de référence d'ingénierie pour MPX2053GVP — comparaison, recommandations de conception et informations de conformité.

Guide de sélection

Choose the MPX2053GVP when you need a vented gauge 0 to 50 kPa pressure sensor with a top-port 4-SIP through-hole package and a male 4.93 mm tube inlet - ideal for HVAC, medical respiratory, and appliance water-level designs. Choose the MPX2053GP if your plumbing requires an axial port instead of a top port. Choose the MPX2053GS for side-port orientation with the same 4-SIP footprint. Choose the MPX2053D when you need true differential pressure measurement across two ports. Choose the MPX2053AP for absolute pressure reference. All five parts share the same calibrated 0 mV to 40 mV span at 10 V, so signal-chain design can be reused across the family.

Comparaison avec les alternatives

Paramètre Ce produit MPX2053GP MPX2053GS MPX2053GVX MPX2053D
Brand NXP Semiconductors NXP Semiconductors - same NXP Semiconductors - same NXP Semiconductors - same NXP Semiconductors - same
Package 4-SIP Top Port 4-SIP - same 4-SIP - same 4-SIP Top Port - same 4-SIP - same
Pressure Type Vented Gauge Vented Gauge Vented Gauge Vented Gauge (top port) Differential
Operating Pressure Range 0 to 50 kPa 0 to 50 kPa 0 to 50 kPa 0 to 50 kPa 0 to 50 kPa differential
Output Span at 10V 0 mV to 40 mV 0 mV to 40 mV 0 mV to 40 mV 0 mV to 40 mV 0 mV to 40 mV
Port Style Male 4.93 mm Tube Top Axial port Side port Top port Dual differential ports
Operating Temperature -40 C to +125 C -40 C to +125 C -40 C to +125 C -40 C to +125 C -40 C to +125 C
Supply Voltage 10 V to 16 V 10 V to 16 V 10 V to 16 V 10 V to 16 V 10 V to 16 V

Principaux différenciateurs

  • Top-port vented gauge configuration with 4.93 mm tube inlet (vs MPX2053GP)
  • Vented gauge reference eliminates barometric correction (vs MPX2053AP)
  • On-chip temperature compensation and calibration (vs MPX2053D (differential variant))

Notes de conception

Drive the MPX2053GVP bridge from a low-noise, low-impedance 10 V excitation source such as the MAX6126 reference followed by a buffer op-amp. Add a 100 nF ceramic decoupling capacitor close to pin 4 (Vs) and a 100 nF cap on pin 2 (GND) to suppress high-frequency noise. Self-heating of the bridge at high excitation currents introduces span drift; keep total bridge drive below 1 mA to minimize thermal errors.

Place the sensor as close as possible to the ADC input to minimize noise pickup on the high-impedance mV output traces. Use guard rings around the output traces and a star-ground topology that ties the sensor GND, ADC GND, and excitation ground at a single point. Keep digital switching traces (PWM, relays) routed away from the bridge output to avoid coupling interference into the 40 mV full-scale signal.

The MPX2053GVP's 40 mV full-scale output is small relative to typical thermocouple and ground-loop noise, so use a chopper-stabilized or auto-zero instrumentation amplifier (such as the MAX4194 or MAX4209) with at least 100 dB CMRR at 50/60 Hz. Apply low-pass filtering at 1 kHz to limit noise bandwidth, and consider correlated double sampling in software to remove 1/f noise from the ADC conversion.

Informations de conformité

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Sans plomb
Unknown
Sans halogène
Unknown
Minerais de conflit
Unknown

RoHS, REACH, AEC-Q100, lead-free, and halogen-free status not confirmed in the provided web data - set to unknown per data authenticity rules. The MPX2053GVP is an industrial-grade sensor, not AEC-Q100 automotive qualified.

Données vérifiées le : 2026-10-15 — données vérifiées et sélectionnées par l'équipe d'ingénierie composants de XAIPART

Recherches associées

MPX2053GVP MPX2053GVP datasheet NXP MPX2053GVP pressure sensor 50 kPa vented gauge pressure sensor 4-SIP MPX2053GVP pinout MPX2053GVP HVAC duct pressure MPX2053GVP vs MPX2053GP MPX2053GVP drop-in replacement buy MPX2053GVP online what is the output voltage of MPX2053GVP piezoresistive pressure sensor 40 mV low pressure sensor medical ventilator

Composants & termes associés

NXP Semiconductors MPX2053GVP MPX2053 MPX2053GP MPX2053GS MPX2053D MPX2053GVX piezoresistive pressure sensor Wheatstone bridge vented gauge MEMS pressure sensor 4-SIP package transducer signal conditioning barometric pressure HVAC duct pressure respiratory ventilator analog millivolt output on-chip temperature compensation silicon diaphragm calibrated sensor
RFQ de devis rapide
Renseignez tous les détails — notre équipe commerciale vous répondra sous 24 heures
Référence Fabricant Boîtier QTY Prix cible Total
Total : 0,00 USD
✓
Devis envoyé !

Nous répondrons à votre e-mail sous 24 heures

1
RFQ envoyée
2
Devis reçu
3
Commande passée
4
Paiement
5
Expédié
6
Livré
Voir les détails de la RFQ