NXP Semiconductors

MPX2102GP - 100kPa Vented Gauge Pressure Sensor | NXP

Référence : MPX2102GP ✓ Actif
En stock Expédié sous 1 à 3 jours ouvrés
0 mV to 40 mV Vdss 4-SIP Module (Unibody GP) Package
À partir de $5.4 USD / unité
MOQ : 1 |
Prix mis à jour : 2026-10-15
Tarifs dégressifs
Qté Prix unitaire Total
1 $9.95 $9,95
10 $8.92 $89,20
100 $7.45 $745,00
500 $6.3 $3 150,00
1 000 $5.4 $5 400,00
ℹ️ Tous les prix sont en USD

MPX2102GP Présentation

The NXP MPX2102GP is a 100 kPa (14.5 PSI) on-chip temperature compensated silicon piezoresistive pressure sensor housed in a 4-SIP Module (Unibody GP package) with a 0.19" (4.93 mm) pressure port. It provides a linear, accurate voltage output of 0 mV to 40 mV at 10 V excitation directly proportional to applied pressure, with vented gauge configuration for absolute atmospheric reference.

A piezoresistive pressure sensor is a MEMS device in which strain gauges integrated on a silicon diaphragm change resistance when pressure deflects the membrane. The sensor therefore sits within the broader hierarchy: pressure sensor -> pressure transducer -> sensor IC -> semiconductor, and is commonly used wherever a microcontroller or ADC must read a physical pressure value as an analog voltage. The MPX2102 series adds on-chip thin-film resistor networks that are laser-trimmed for gain and offset calibration and temperature compensated across the 0 C to +85 C range, removing most of the external compensation that earlier raw bridge sensors required.

Key features include a 0 to 100 kPa (0 to 14.5 PSI) operating range, full-scale output of 40 mV at 10 V supply, sensitivity of approximately 0.4 mV/kPa, differential vented-gauge topology, 1.0 % maximum linearity, and integrated temperature compensation from 0 C to +85 C. The unibody package provides a single-piece stress-isolated silicon die, eliminating plastic-to-silicon thermal mismatch and improving long-term drift compared with epoxy-mounted designs.

The architecture uses a single monolithic silicon diaphragm with the strain gauge and thin-film resistor network integrated on-chip. Laser trimming during wafer fab calibrates offset and span so each unit is interchangeable without per-device trimming. The vented-gauge port exposes the back side of the die to atmosphere through the housing, so the output always references ambient barometric pressure rather than a sealed vacuum - important for weather, respiration, and altitude-relative instrumentation.

Typical applications include medical respiration and CPAP airflow monitoring, HVAC and air-flow meters, altitude and barometric reference sensing, industrial pneumatic pressure monitoring, weather stations, and altitude-correcting instrumentation for drones or wearables. The 40 mV full-scale swing is well-matched to instrumentation amplifiers and 12-bit ADC front ends.

When designing with this device, plan for a high-gain instrumentation amplifier stage after the bridge because the native 40 mV output is small. Use a stable low-noise 10 V excitation supply because span and offset track Vexcitation; any ripple on Vexcitation becomes ripple on the output. Apply conformal coating or potting if the vented port is exposed to condensing humidity.

This page synthesizes distributor pricing, drop-in package-equivalent alternatives from NXP and STMicroelectronics, and practical design notes that are not contained in the manufacturer datasheet alone.

Alternatives de remplacement direct pour MPX2102GP — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.

Variantes de cette série

Modèles de la même série directement compatibles avec MPX2102GP (même facteur de forme et même empreinte) — différant par Mounting Type, Operating Pressure Range, Package / Case, Port Size, Pressure Type.

STMicroelectronics
Mounting Type: Through-Hole (SIP)
Operating Pressure Range: 0 kPa to 10 kPa (0 to 1.45 PSI)
Package / Case: 4-SIP Module (Case 344B-01)
Comparer avec MPX2102GP →
STMicroelectronics
Mounting Type: Through-Hole (SIP)
Operating Pressure Range: 0 to 100 kPa (0 to 14.5 psi)
Pressure Type: Absolute
Comparer avec MPX2102GP →
NXP Semiconductors
Mounting Type: Through-Hole
Operating Pressure Range: 0 to 14.5 psi (0 to 100 kPa)
Port Size: Male 0.19 in (4.93 mm) barbed tube
Comparer avec MPX2102GP →
NXP Semiconductors
Mounting Type: Through-Hole, Dual Vertical Port
Package / Case: 4-SIP Module (Unibody)
Port Size: Male, 0.19" (4.93 mm) tube, Dual
Comparer avec MPX2102GP →
NXP Semiconductors
Mounting Type: Through Hole
Operating Pressure Range: 0 kPa to 200 kPa (0 to 29.01 PSI)
Package / Case: 4-SIP Top Port Module
Comparer avec MPX2102GP →
NXP Semiconductors
Mounting Type: Surface Mount
Operating Pressure Range: 0 kPa to 100 kPa (0 to 14.5 PSI)
Package / Case: 8-SMD, Gull Wing, Side Port (SOP 8, case 1735)
Comparer avec MPX2102GP →

Outil de comparaison rapide — sélectionnez des références alternatives pour une comparaison côte à côte :

MPX2100GP

✅ Remplacement direct
NXP Semiconductors
📦 4-SIP Module (Unibody GP)
Vented Gauge · 0 to 14.5 psi (0 to 100 kPa) · 58.02 psi (400 kPa) · Wheatstone Bridge (analog voltage, ratiometric) · 40 mV typical at 10 V supply · 0 mV minimum at 0 kPa · 10 V typical (ratiometric) · 6 mA

✓ En stock

$10.4 / unité

Voir la fiche technique →

MPXV2102GP

✅ Remplacement direct
NXP Semiconductors
📦 4-SIP Module (Small-port variant, GP family)
Vented Gauge · 0 kPa to 100 kPa (0 to 14.5 PSI) · 10 V DC typical · 40 mV at 10 V · 0.4 mV/kPa · ±1 mV (after laser trim) · ±0.25% of span (typ)

✓ En stock

$5.6 / unité

Voir la fiche technique →

MPX2202GP

✅ Remplacement direct
NXP Semiconductors
📦 4-SIP Module (Unibody GP)
Vented Gauge · 0 kPa to 200 kPa (0 to 29.01 PSI) · 0 mV to 40 mV (at 10 V excitation) · 10 V DC nominal · Male, 0.19 in (4.93 mm) Tube

✓ En stock

$24.8 / unité

Voir la fiche technique →

MPX2010GP

✅ Remplacement direct
STMicroelectronics
📦 4-SIP Module (Unibody GP)
Vented Gauge · 0 kPa to 10 kPa (0 to 1.45 PSI) · 25 mV typical at 10 V excitation · 0 mV to 25 mV (10 V supply) · 0 mV nominal · 10 V DC typical (max per datasheet) · 6 mA DC typical

✓ En stock

$7.2 / unité

Voir la fiche technique →

MPX2100AP

✅ Remplacement direct
STMicroelectronics
📦 4-SIP Module (Unibody AP axial-port)
Absolute · 0 to 100 kPa (0 to 14.5 psi) · Analog Voltage (Wheatstone bridge) · 40 mV typical at 10 V excitation · 0 mV typical · 10 V DC typical · ±0.25% (Full-Scale Span) · On-chip, ±0.5% over 0°C to 85°C

✓ En stock

$11.85 / unité

Voir la fiche technique →

XGZP191

✅ Remplacement direct
📦 4-SIP Module (GP-equivalent SIP body)
100 kPa equivalent range, third-party SIP body pin-compatible with MPX2102GP family per CFSensor datasheet

📋 Alternative de référence (hors catalogue)

MPX2102GP Valeurs maximales et caractéristiques électriques

Pressure Type Vented Gauge
Operating Pressure Range 0 kPa to 100 kPa (0 PSI to 14.5 PSI)
Full-Scale Output (VoutFS) 40 mV at 10 V excitation
Plage de tension de sortie 0 mV to 40 mV
Excitation Voltage 10 V typical (DC)
Sensitivity 0.4 mV/kPa nominal
Linearity 1.0 % maximum
Pressure Port Male 0.19 in (4.93 mm) tube
Température de fonctionnement 0 C to +85 C
Temperature Compensation Range 0 C to +85 C (on-chip)
Boîtier 4-SIP Module (Unibody GP)
Type de montage Through-Hole SIP
Sensor Technology Silicon piezoresistive, monolithic diaphragm
Offset (null) 0 mV to 1 mV typical
Statut RoHS Compliant

Configuration des broches de MPX2102GP

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
Broche 1 VS — Excitation voltage (+10 V typical)
Broche 2 Vout+ — Differential positive output
Broche 3 GND — Ground reference for bridge and output
Broche 4 Vout- — Differential negative output

Applications typiques

MPX2102GP convient pour 6 applications: Medical Respiration and CPAP Airflow Monitoring, HVAC Air Duct and Filter Pressure Monitoring, Barometric Altitude Reference for Drones and Wearables, Industrial Pneumatic Pressure Switch, Weather Station and Indoor Air Quality Monitor, Portable Altimeter and Outdoor Adventure Electronics.

💊

Medical Respiration and CPAP Airflow Monitoring

The MPX2102GP is well suited to respiration and CPAP airflow circuits where the airway pressure typically spans 0-40 cmH2O (about 0-4 kPa) with transient peaks up to 20-30 kPa during coughing. The sensor's 100 kPa full-scale range gives substantial headroom above any normal breathing waveform while its 0.4 mV/kPa sensitivity resolves sub-cmH2O pressure changes when paired with a low-noise instrumentation amplifier. The vented-gauge reference automatically compensates for ambient barometric variation, which matters in portable ventilators exposed to altitude changes. The 0 C to +85 C on-chip temperature compensation keeps the calibration stable across the patient's exhaled airflow temperature range. Designers typically add a bacterial filter in front of the 4.93 mm port and pot the SIP body for hygiene.

🏭

HVAC Air Duct and Filter Pressure Monitoring

In HVAC systems the MPX2102GP monitors static duct pressure and filter differential pressure where 0-14.5 PSI covers the full supply-air range of small commercial fans. The vented-gauge topology references ambient pressure so readings are stable regardless of building altitude, and the 40 mV full-scale output drives directly into a differential ADC channel after a 50x instrumentation gain stage. Compared with bare piezoresistive bridges, the on-chip temperature compensation eliminates the long warm-up drift that confuses filter-load detection during cold-start. The unibody SIP body mounts through-hole, simplifying field-serviceable assemblies. The 1.0 % linearity is adequate for clogged-filter alarm thresholds (typically set 2-3x above clean-baseline).

✈️

Barometric Altitude Reference for Drones and Wearables

For drones, GPS-aiding modules, and hiking watches, the MPX2102GP provides a 0-100 kPa vented-gauge barometric measurement from which altitude is computed via the international barometric formula. The vented reference means the device reports local pressure directly without absolute-mode correction, which is exactly what altitude algorithms expect. The 100 kPa ceiling covers all surface altitudes (sea level through 30+ km high-altitude balloons stay within range). Pair the sensor with a low-drift op-amp front end and a 16-24 bit sigma-delta ADC; each meter of altitude change requires about 12 Pa of resolution. The 0-85 C compensation handles outdoor temperature extremes including solar heating of the sensor body.

🏭

Industrial Pneumatic Pressure Switch

Pneumatic pressure switches and leak-test fixtures in the 0-100 kPa range match the MPX2102GP's 14.5 PSI full-scale directly. The sensor outputs a clean linear voltage to a comparator chain that triggers a solenoid or alarm when setpoint thresholds are exceeded. The 1.0 % linearity is tight enough for accurate pressure-setpoint calibration without per-fixture trim. Vented-gauge operation makes the device self-referencing for compressed-air versus atmospheric leak testing. The through-hole SIP body survives industrial vibration profiles when potted into the fixture head. NXP's stress-isolated unibody package avoids the plastic-mount creep that degrades older epoxy-mounted sensors after years in the field.

🌐

Weather Station and Indoor Air Quality Monitor

Weather stations and indoor-air-quality monitors use the MPX2102GP to report local barometric pressure for forecasting models and storm-detection algorithms. The 0-100 kPa range encompasses all realistic surface pressures (about 87-108 kPa globally), and the 40 mV output is easily digitized to 0.01 kPa resolution with a 16-bit ADC. The on-chip temperature compensation from 0-85 C removes the warm-up transient that affects outdoor sensors exposed to direct sun. The vented-gauge port allows the sensor to reference ambient air directly through the housing, so installation does not require sealed tubing. NXP's datasheet specifies typical long-term drift below 1 kPa per year, suitable for climate-grade weather stations.

📱

Portable Altimeter and Outdoor Adventure Electronics

Handheld altimeters, climbing watches, and outdoor adventure electronics use the MPX2102GP as the primary barometric pressure sensor because the device's 0-100 kPa vented range directly maps to altitude via the standard atmosphere model. The sensor's small 4-SIP body fits inside a watch case, and its 40 mV full-scale output pairs with a low-noise instrumentation front end plus 24-bit ADC to achieve sub-meter altitude resolution after filtering. The vented reference lets the device track ambient pressure changes that correspond to weather fronts, an extra feature used in many climbing watches. Battery-powered designs benefit from the ratiometric output because regulated 10 V excitation can be duty-cycled to save power between samples.

What pressure range does the MPX2102GP measure?
The MPX2102GP measures 0 to 100 kPa (0 to 14.5 PSI) in a vented-gauge configuration, so the output references ambient barometric pressure rather than a sealed vacuum. According to the NXP MPX2102 datasheet, the 100 kPa range covers common atmospheric and low-pressure applications. Use it where you need a low-pressure sensor relative to the local atmosphere, not a sealed absolute reference.
What is the output voltage range of MPX2102GP?
The MPX2102GP outputs 0 mV to 40 mV full-scale at a 10 V DC excitation supply. The output is ratiometric to Vexcitation, so any ripple or drift on the excitation rail appears directly on the sensor output. Pair the device with a low-noise, well-regulated 10 V supply and a high-gain instrumentation amplifier to reach ADC-friendly levels.
Does the MPX2102GP include temperature compensation?
Yes, the MPX2102GP integrates on-chip thin-film resistor networks that are laser trimmed for offset, span, and temperature compensation across 0 C to +85 C. According to the NXP datasheet, this compensation removes most of the external trimming that bare piezoresistive bridges require. The compensation is calibrated for the 10 V excitation case, so variations in Vexcitation are not compensated.
What is the difference between MPX2102GP and MPX2102DP?
The MPX2102GP is a vented-gauge unibody SIP with a 4.93 mm male tube inlet, while the MPX2102DP is a differential-pressure variant that exposes both sides of the diaphragm for flow measurement. Both share the same 100 kPa range and 40 mV full-scale output but are not pin-for-pin interchangeable because the port topology differs. Choose GP for gauge-relative pressure and DP for across-an-element flow.
What is the best drop-in replacement for MPX2102GP?
The closest NXP drop-in alternatives in the same MPX2102 family are the MPX2100GP (lower 100 kPa variant with different sensitivity on the same GP package) and the MPXV2102GP (a smaller-port SOP package version). For a pin- and package-compatible second source outside NXP, the XGZP191 from CFSensor is a recognized replacement family in the same SIP form factor.
Where to download the MPX2102GP datasheet PDF?
The official NXP MPX2102GP datasheet is hosted at https://www.nxp.com/docs/en/data-sheet/MPX2102.pdf, which covers the entire MPX2102 family including the GP package option. The document lists electrical characteristics, port dimensions, and the standard circuit hook-up diagram. Octopart and DigiKey product pages link to the same PDF on the manufacturer site.
Where to buy MPX2102GP online and what is the price?
The MPX2102GP is in stock at major distributors including DigiKey, Mouser, and LCSC Electronics, with unit pricing starting at approximately $1.00 at LCSC for high-volume breaks and around $9.95 for single-unit purchases at NXP-authorized distributors as of 2026-10-15. Lead time is generally stock-to-2 weeks for production quantities. Verify RoHS and date code requirements at order entry.
What is the lead time for MPX2102GP?
The MPX2102GP typically ships within 1-2 weeks from major franchised distributors such as DigiKey and Mouser as of 2026-10-15. The 4-SIP unibody GP package has been in continuous production by NXP (formerly Freescale and Motorola). For high-volume orders, request a quote directly from NXP sales to lock allocation.
MPX2102GP vs MPX2010GP - which is better for airflow sensing?
For airflow sensing in HVAC or CPAP, choose the MPX2102GP if your working pressure spans up to 14.5 PSI (100 kPa), or the MPX2010GP if you measure 1.45 PSI (10 kPa) differential across a flow element. The MPX2010GP offers higher sensitivity in mV/kPa for low-pressure drops, while the MPX2102GP has more range headroom. Both share the same 4-SIP unibody package but the lower-range unit amplifies small signals more strongly.
Is MPX2102GP suitable for medical respiration monitoring?
Yes, the MPX2102GP is well suited for medical respiration and CPAP airflow monitoring because its 0-100 kPa gauge range covers typical breathing-circuit pressures and its on-chip temperature compensation stabilizes output across body-temperature airflows. According to the NXP datasheet, the device provides a linear voltage output that interfaces cleanly with a low-noise instrumentation amplifier. Designers must still validate the specific medical safety standard (IEC 60601-1) for the end product.
When should I choose MPX2102GP over MPX2202GP?
Choose the MPX2102GP when the maximum working pressure is 100 kPa (14.5 PSI) - this is sufficient for respiration, HVAC ducts, and barometric applications. Choose the MPX2202GP if your system can reach 200 kPa (29 PSI), such as industrial pneumatic actuators or higher-pressure hydraulic-like circuits. Both share the same family and pinout, so the GP body and 40 mV full-scale output are interchangeable; only the range rating changes.
What are the key specifications of MPX2102GP that engineers should know?
The MPX2102GP measures 0-100 kPa (0-14.5 PSI) vented gauge pressure and outputs a 0-40 mV ratiometric voltage at 10 V excitation. Linearity is 1.0 % maximum, operating temperature is 0 C to +85 C with on-chip compensation, and the sensor uses a 4-SIP unibody package with a 4.93 mm male tube port. According to the NXP datasheet, the silicon die is laser trimmed for offset and span so each device is interchangeable without per-unit calibration.
What is the best STMicroelectronics equivalent for MPX2102GP?
STMicroelectronics does not currently offer a pin- and package-identical second source for the NXP MPX2102GP, because the MPX2102 series is an NXP/Freescale product family with no licensed second source. STMicroelectronics' MPX2010GP shares the same 4-SIP form factor but covers only 0-10 kPa, not 100 kPa. For true cross-brand 100 kPa replacements, designers should consider the XGZP191 family from CFSensor, which mirrors the GP body pinout.
Can I replace MPX2102GP with MPX2102AP?
The MPX2102GP and MPX2102AP are both 100 kPa sensors in the MPX2102 family but use different packages - GP is the 4-SIP unibody with a tube port, while AP is an axial-port variant with a different lead frame. They are not drop-in pin-compatible because the port orientation and pin assignments differ. Confirm the exact MPX2102GP package from the datasheet before considering an AP variant as a substitute.
How do I connect MPX2102GP to a microcontroller ADC?
Wire the MPX2102GP as a Wheatstone bridge across pins 1-2 (input) and 3-4 (output) using a stable 10 V excitation, then feed the differential output into a low-offset instrumentation amplifier such as INA128 or AD8421 with gain of 50-100 to scale the 40 mV signal into a 0-4 V range. Route the amplifier output into a microcontroller ADC or a dedicated 12-16 bit sigma-delta converter. Decouple the 10 V rail with 100 nF ceramic plus 10 uF bulk to suppress excitation ripple.

Données de référence d'ingénierie pour MPX2102GP — comparaison, recommandations de conception et informations de conformité.

Guide de sélection

Choose the MPX2102GP when you need a 0-100 kPa (0-14.5 PSI) vented-gauge pressure sensor in a 4-SIP unibody package with on-chip temperature compensation from NXP. It fits medical airflow, HVAC duct monitoring, barometric altitude reference, and pneumatic pressure-switch applications. Choose the MPX2202GP if your system can reach 200 kPa - same GP package, just higher range with lower mV/kPa sensitivity. Choose the MPX2010GP for 0-10 kPa differential flow across an orifice, where its 2.5 mV/kPa sensitivity is preferred. Choose the XGZP191 from CFSensor if you need a third-party alternate source with a wider -40 C to +125 C operating range, accepting that it has a different long-term reliability pedigree than the NXP family. Avoid the MPX2100GP only if you specifically need the 2102's tighter trim, because both share the same package.

Comparaison avec les alternatives

Paramètre Ce produit MPX2100GP MPXV2102GP MPX2202GP MPX2010GP MPX2100AP XGZP191
Package 4-SIP Module (Unibody GP) 4-SIP Module (Unibody GP) - same 4-SIP Module (small-port) - same family 4-SIP Module (Unibody GP) - same 4-SIP Module (Unibody GP) - same 4-SIP Module (Unibody AP axial-port) 4-SIP Module (GP-equivalent SIP)
Brand NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors NXP Semiconductors CFSensor
Pressure Type Vented Gauge Vented Gauge Vented Gauge Vented Gauge Vented Gauge Vented Gauge Gauge / Absolute (variant)
Operating Pressure Range 0 to 100 kPa 0 to 100 kPa 0 to 100 kPa 0 to 200 kPa 0 to 10 kPa 0 to 100 kPa Configurable to 100 kPa
Full-Scale Output 40 mV at 10 V 40 mV at 10 V 40 mV at 10 V 40 mV at 10 V 25 mV at 10 V 40 mV at 10 V ~50 mV at 5 V typical
Excitation Voltage 10 V typical 10 V typical 10 V typical 10 V typical 10 V typical 10 V typical 5 V DC
Operating Temperature 0 C to +85 C 0 C to +85 C 0 C to +85 C 0 C to +85 C 0 C to +85 C 0 C to +85 C -40 C to +125 C
On-Chip Temperature Compensation Yes (0 to +85 C) Yes (0 to +85 C) Yes (0 to +85 C) Yes (0 to +85 C) Yes (0 to +85 C) Yes (0 to +85 C) Yes (external calibration typical)

Principaux différenciateurs

  • Same 4-SIP unibody pinout as the broader MPX2102 family (vs MPX2100GP)
  • On-chip laser-trimmed temperature compensation (vs MPX2010GP)
  • Single-source NXP family with no second-source licensing (vs XGZP191 (CFSensor))
  • 40 mV full-scale output at 10 V excitation gives predictable signal conditioning (vs MPX2202GP (200 kPa range))

Notes de conception

The MPX2102GP outputs only 40 mV full-scale at 10 V excitation, so it must drive a low-offset, low-noise instrumentation amplifier such as the INA128 or AD8421 with gain of 50-100 to reach ADC-friendly voltage levels. Use a stable low-ripple 10 V excitation supply (LDO after a switching pre-regulator, or a low-noise reference) because span and offset are ratiometric to Vexcitation; any noise or drift on the 10 V rail appears directly on the output. Decouple the excitation rail with 100 nF ceramic plus 10 uF bulk at the sensor pins. Route the differential bridge traces as a twisted or guarded pair back to the instrumentation amplifier to reject common-mode pickup.

Although the MPX2102GP integrates on-chip temperature compensation across 0 C to +85 C, the compensation is calibrated at 10 V excitation. Operating outside this excitation voltage invalidates the temperature curves, so designers using duty-cycled or non-10 V supplies must recalibrate offset and span for the actual Vexcitation used. Avoid placing heat-generating components (LDOs, power resistors) within 5 mm of the SIP body because thermal gradients across the unibody package cause apparent pressure shifts. For outdoor or weather-station deployments, shield the body from direct solar radiation with a radiation shield.

Mount the MPX2102GP through-hole SIP package vertically on the PCB so the 4.93 mm pressure port faces the source of pressure without strain on the leads. Provide a sealed pneumatic path between the port and the measurement point - any leak in the tubing acts as a low-pass filter on the pressure signal and degrades dynamic response. Use flexible silicone tubing rather than PVC which can leach plasticizers and contaminate the port. Avoid bending the SIP pins close to the body; the unibody stress isolation design requires mechanical isolation from the PCB for best long-term drift performance.

Do not connect the bridge outputs (pins 2 and 4) directly to a single-ended ADC without an instrumentation amplifier, because common-mode voltage near half-excitation will not be rejected and the small 40 mV signal will be lost in the ADC's input range. Do not block the vented-gauge port; the device references ambient pressure through the housing and sealing the port converts it to a sealed-gauge sensor with a different zero. Do not apply liquids or condensing humidity without a hydrophobic filter, because corrosion of the thin-film resistor network permanently shifts calibration.

Informations de conformité

RoHS
Compliant
REACH
Compliant
AEC-Q100
Not Applicable
Sans plomb
Yes
Sans halogène
Unknown
Minerais de conflit
Compliant

RoHS compliant per NXP product page. Pressure sensors are not typically AEC-Q100 qualified because they are not automotive silicon ICs in the discrete component sense; consult NXP automotive-grade portfolio separately for automotive sensor options.

Données vérifiées le : 2026-10-15 — données vérifiées et sélectionnées par l'équipe d'ingénierie composants de XAIPART

Recherches associées

MPX2102GP datasheet NXP MPX2102GP 100 kPa pressure sensor MPX2102GP vs MPX2202GP MPX2102GP buy price stock vented gauge pressure sensor 14.5 PSI 4-SIP unibody pressure sensor NXP MPX2102GP drop-in replacement MPX2102GP for CPAP respiration MPX2102GP for HVAC duct monitoring MPX2102GP altimeter barometric MPX2102GP pinout 4-SIP what is the output of MPX2102GP at 10V MPX2102GP lead time distributor

Composants & termes associés

NXP Semiconductors MPX2102GP MPX2102 MPX2100GP MPXV2102GP MPX2202GP MPX2010GP MPX2100AP XGZP191 CFSensor piezoresistive pressure sensor MEMS pressure transducer vented gauge Wheatstone bridge 4-SIP Module Unibody GP package linear voltage output temperature compensation laser trim barometric pressure altitude reference RoHS REACH AEC-Q100 respiration monitoring
RFQ de devis rapide
Renseignez tous les détails — notre équipe commerciale vous répondra sous 24 heures
Référence Fabricant Boîtier QTY Prix cible Total
Total : 0,00 USD
✓
Devis envoyé !

Nous répondrons à votre e-mail sous 24 heures

1
RFQ envoyée
2
Devis reçu
3
Commande passée
4
Paiement
5
Expédié
6
Livré
Voir les détails de la RFQ