OPA234UA - Low-Power Precision Op Amp | Texas Instruments
Référence : OPA234UA ✓ ActifOPA234UA Présentation
An operational amplifier is an analog signal-conditioning integrated circuit that uses high open-loop gain to amplify small voltage differences. In the broader electronics hierarchy, the OPA234UA belongs to the linear amplifier, operational amplifier, and analog integrated-circuit categories. Its low-power architecture makes it especially useful in battery-powered instrumentation, portable measurement systems, industrial sensors, and low-voltage signal-conditioning circuits where both supply-voltage range and current consumption matter.
The OPA234 series combines low offset voltage, high common-mode rejection ratio, and high power-supply rejection ratio. Its input common-mode range can extend below ground in single-supply operation, while the output can swing to within 50 mV of ground. These characteristics support direct sensing of low-level signals referenced to ground without a separate negative supply. The combination of 350 kHz bandwidth and 0.2 V/µs slew rate also provides useful response speed for precision DC and low-frequency AC signal paths.
OPA234UA is intended for low-voltage, low-power applications and can operate from either single or dual power supplies. Single-supply operation extends to 36 V, while dual operation reaches ±18 V. The low 250 µA-per-amplifier quiescent current reduces supply demand in portable systems, although input bias current, offset voltage, noise, and load-capacitance limits must still be checked against the application’s precision and stability requirements.
Typical uses include low-level sensor conditioning, portable instrumentation, buffered analog measurements, and precision current-voltage signal chains. The device is particularly appropriate when the source signal is close to ground and a negative supply would otherwise be required. It is also suitable for industrial systems that need a wide supply range, although input and output common-mode limits must be respected at each supply voltage.
When designing a circuit around the OPA234UA, place input and output decoupling capacitors close to their corresponding supply pins and keep feedback components compact to minimize parasitic capacitance and instability. Check the datasheet’s common-mode, output-swing, and capacitive-load limits before operating near a supply rail. Avoid assuming that the rail-to-rail input capability permits arbitrary source voltages outside the specified common-mode range.
This product data combines supply-range, bandwidth, slew-rate, packaging, and cross-reference information with application guidance, comparison parameters, and practical design considerations. It helps engineers evaluate whether the OPA234UA fits a low-power precision signal path and identify a pin-compatible replacement without overlooking the electrical limits of the SOIC-8 footprint.
Alternatives de remplacement direct pour OPA234UA — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.
OPA234UAG4
✅ Remplacement direct📋 Alternative de référence (hors catalogue)
OPA234UA Valeurs maximales et caractéristiques électriques
| Number of Amplifiers | 1 amplifier |
| Product Type | Low-power precision operational amplifier |
| Single-Supply Voltage Range | Up to 36 V |
| Dual-Supply Voltage Range | ±18 V |
| Guaranteed Supply Configurations | 2.7 V, 5 V, and ±15 V |
| Courant de repos | 250 µA per amplifier |
| Gain-Bandwidth Product | 350 kHz |
| Slew Rate | 0.2 V/µs |
| Single-Supply Common-Mode Range | Extends below ground |
| Minimum Output Swing to Ground | 50 mV |
| Boîtier | 8-pin SOIC |
| Type de montage | Surface mount |
Configuration des broches de OPA234UA
| Broche 1 | NC — Unused amplifier-channel pin; connection must follow the manufacturer datasheet |
| Broche 2 | NC — Unused amplifier-channel pin; connection must follow the manufacturer datasheet |
| Broche 3 | NC — Unused amplifier-channel pin; connection must follow the manufacturer datasheet |
| Broche 4 | V- — Negative supply connection |
| Broche 5 | NC — Unused amplifier-channel pin; connection must follow the manufacturer datasheet |
| Broche 6 | NC — Unused amplifier-channel pin; connection must follow the manufacturer datasheet |
| Broche 7 | NC — Unused amplifier-channel pin; connection must follow the manufacturer datasheet |
| Broche 8 | V+ — Positive supply connection |
Applications typiques
OPA234UA convient pour 6 applications: Portable Sensor Signal Conditioning, Battery-Powered Measurement, Industrial Process Monitoring, Low-Voltage Audio and Control Signals, Precision Current-to-Voltage Conversion, Precision Data-Acquisition Front End.
Portable Sensor Signal Conditioning
The OPA234UA fits portable sensor-conditioning circuits because its single-supply operation extends to 36 V, its input common-mode range extends below ground, and its quiescent current is 250 µA per amplifier. It can amplify a sensor output close to 0 V without adding a negative supply rail, helping reduce board complexity. The 350 kHz gain-bandwidth product and 0.2 V/µs slew rate are sufficient for many pressure, temperature, and position sensors operating at low or moderate frequencies. Confirm the actual sensor output range against the amplifier’s common-mode limits, and verify settling requirements at the selected closed-loop gain before finalizing the filter network.
Recommandé
Battery-Powered Measurement
OPA234UA is appropriate for battery-powered measurement equipment where amplifier power consumption affects operating time. Its 250 µA-per-amplifier quiescent current is low enough to support compact portable instruments, while operation from 2.7 V single supply covers common low-energy systems. The device can process signals near ground because its single-supply input common-mode range extends below ground. Designers should include the output load, feedback network, and protection leakage in the complete power budget, and confirm that output settling remains adequate for the measurement bandwidth before choosing the final gain and compensation values.
Recommandé
Industrial Process Monitoring
The OPA234UA can be used in industrial process-monitoring front ends that need a wide supply range and precision DC performance. A single 36 V supply provides useful input headroom, while ±18 V dual operation supports legacy instrumentation. The low offset voltage, high common-mode rejection ratio, and high power-supply rejection ratio described by the manufacturer help preserve measurement accuracy near supply-distribution noise. However, compliance details and the exact operating-temperature range must be confirmed for the installation environment. The complete front end should also include input filtering, surge protection, and a defined grounding strategy.
Recommandé
Low-Voltage Audio and Control Signals
OPA234UA can amplify low-level control or audio-related signals in compact single-supply systems. Its 350 kHz gain-bandwidth product and 0.2 V/µs slew rate are adequate for many low-frequency audio and control paths, while the output can approach ground to within 50 mV. This makes it useful where the signal is centered near the lower supply rail and a bipolar output would be inconvenient. For higher-bandwidth audio or capacitive loads, verify the required frequency response, output swing, and stability margin rather than assuming general-purpose performance is sufficient.
Recommandé
Precision Current-to-Voltage Conversion
OPA234UA is well suited to precision transimpedance and current-to-voltage conversion when the source current is low frequency and the output must operate from a single supply. The input common-mode range extending below ground allows feedback arrangements referenced to ground, and the low 250 µA quiescent current helps preserve measurement-system efficiency. Feedback-resistor noise and input-bias current can dominate accuracy at very small currents, so use stable resistors and verify temperature coefficients. The 350 kHz bandwidth also limits how quickly the loop can respond to transients, making the complete sensor bandwidth a key design criterion.
Recommandé
Precision Data-Acquisition Front End
OPA234UA can serve as the analog amplifier ahead of a data-acquisition converter in a precision measurement chain. Its low offset voltage, high common-mode rejection ratio, and high power-supply rejection ratio help reduce systematic errors, while operation from 2.7 V, 5 V, or ±15 V supports multiple instrument architectures. The 350 kHz gain-bandwidth product should be compared with the required closed-loop bandwidth and settling time, not merely with the converter’s sample rate. Input antialiasing, common-mode-range checks, and layout measures that minimize parasitic pickup remain necessary for accurate acquisition results.
Recommandé
Données de référence d'ingénierie pour OPA234UA — comparaison, recommandations de conception et informations de conformité.
Guide de sélection
Comparaison avec les alternatives
| Paramètre | Ce produit | OPA234UAG4 |
|---|---|---|
| Brand | Texas Instruments | Texas Instruments |
| Package | 8-pin SOIC | 8-pin SOIC - same package |
| Number of Amplifiers | 1 amplifier | 1 amplifier |
| Single-Supply Maximum | 36 V | 36 V |
| Dual-Supply Maximum | ±18 V | ±18 V |
| Quiescent Current | 250 µA per amplifier | 250 µA per amplifier |
| Gain-Bandwidth Product | 350 kHz | 350 kHz |
| Slew Rate | 0.2 V/µs | 0.2 V/µs |
| Output Swing to Ground | Within 50 mV of ground | Within 50 mV of ground |
| Special Features | Single-supply common-mode range extends below ground | Same principal characteristics and terminal arrangement |
Principaux différenciateurs
- Pin-compatible replacement with no principal performance change (vs OPA234UAG4)
- Wide single-supply operating range (vs OPA234UAG4)
- Low quiescent current with useful signal bandwidth (vs OPA234UAG4)
Notes de conception
Use the manufacturer pin-description table when assigning the eight SOIC pins, especially the unused amplifier-channel pins. Place supply-bypass capacitors close to pins 4 and 8 and keep the feedback loop compact. A short, narrow input route and a stable ground-return path help prevent parasitic capacitance and common-mode pickup from degrading the 350 kHz gain-bandwidth capability.
Estimated: at a 5 V single supply, 250 µA quiescent current and a 100 kΩ load to ground produce approximately 5 V × (250 µA + 50 µA) = 1.5 mW of estimated amplifier power, excluding output-current variation and external-network current. These inputs illustrate why OPA234UA is attractive for portable designs. Confirm total system consumption using the actual load, feedback network, and operating state.
Do not assume that an input can be driven beyond the common-mode range even though it can operate from a single supply and accept signals below ground. Likewise, the output reaching within 50 mV of ground does not guarantee a zero-volt output. Review the manufacturer’s input-range and output-swing graphs for the selected supply voltage, load, and temperature before setting signal or feedback limits.
Keep input and feedback components close to the SOIC pins and avoid long parallel routes around the amplifier. For low-level measurements, use a single grounded reference point and shield or guard sensitive input traces where appropriate. The 350 kHz closed-loop bandwidth and 0.2 V/µs slew rate limit large-signal performance, so verify the required signal amplitude and frequency rather than relying on small-signal bandwidth alone.
Informations de conformité
No explicit OPA234UA compliance declarations were identified in the manufacturer or distributor information. Confirm RoHS, REACH, AEC-Q100, lead-free, halogen-free, and conflict-minerals status from current manufacturer documentation before qualification.