SY89296UMI - 1024-Tap Programmable Delay Line | Microchip
Référence : SY89296UMI ✓ ActifSY89296UMI Présentation
A programmable delay line is a clock-and-timing semiconductor that inserts a controlled interval between an input transition and an output transition. It belongs to the delay-line and timing-element hierarchy, where adjustable propagation delay supports calibration, trigger alignment, data acquisition, communications timing, and signal-conditioning applications. The SY89296UMI converts a programmable digital control into a fine-resolution delay across 1024 available taps.
The principal features include 1024 programmable taps, a 10 ps increment per tap, a 3.2 ns minimum programmed delay, a 14.8 ns maximum programmed delay, and a 2.375 V to 3.6 V operating supply range. Its exposed-pad VFQFN construction supports heat dissipation through the PCB copper area, while the surface-mount format reduces board area compared with many older delay packages.
The delay is established from the device's 1024-tap organization rather than through an external timing network. A 10 ps tap increment provides substantially finer control than coarse selectable-delay devices, allowing calibration or timing compensation to be adjusted in regular steps. The 3.2 ns to 14.8 ns range covers short propagation intervals suitable for precision synchronization, pulse qualification, and embedded timing correction.
Typical uses include clock and data capture systems, communications interface timing, pulse-generation and debounce circuits, test and measurement instrumentation, and clock-alignment networks. In these systems, the device can compensate for propagation differences introduced by external circuitry or provide a controlled delay between related signals.
PCB layout should preserve a continuous return path beneath the exposed pad and minimize sensitive timing traces near high-current switching nodes. Decoupling capacitors should be placed close to the supply and ground pins, while the control interface traces should be kept short to reduce control-timing skew. The device requires careful review of its pin description, control-code table, supply requirements, and timing characteristics before layout release.
This page combines the exact orderable MPN, programming details, package information, application guidance, replacement criteria, and engineering design notes needed to evaluate the SY89296UMI as a precision timing component.
Alternatives de remplacement direct pour SY89296UMI — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.
Aucune alternative de remplacement direct disponible pour ce produit.
Demander des alternativesSY89296UMI Spécifications
| Product Type | Programmable delay line IC |
| Product Series | Precision Edge SY89296U |
| Number of Taps | 1024 taps |
| Tap Increment | 10 ps |
| Programmable Delay Range | 3.2 ns to 14.8 ns |
| Minimum Delay to First Tap | 3.2 ns |
| Supply Voltage Range | 2.375 V to 3.6 V |
| Plage de température de fonctionnement | -40 °C to +85 °C |
| Boîtier | 32-pin VFQFN with exposed pad |
| Package Code | 32-MLF |
| Type de montage | Surface mount |
Guide de configuration des broches du SY89296UMI 32-mlf
Configuration des broches du SY89296UMI (boîtier 32-mlf). La numérotation des broches, les fonctions et les schémas de connexion sont définis dans la fiche technique du fabricant. Consultez-la pour l'empreinte exacte et les directives de soudage.
Aucune donnée de brochage détaillée disponible pour SY89296UMI.
Consultez la fiche technique pour la configuration complète des broches.
Applications typiques
SY89296UMI convient pour 6 applications: Clock and Data Alignment, Communications Signal Conditioning, Pulse Qualification and Debounce, Test and Measurement Instrumentation, Synchronous Interface Compensation, Industrial Timing Control.
Clock and Data Alignment
The SY89296UMI fits clock-and-data alignment networks that require fine, digitally adjustable propagation delay. Its 1024 taps and 10 ps increment let a system correct small timing offsets introduced by board traces, connectors, cables, or adjacent logic without changing discrete delay components. The selectable range of 3.2 ns to 14.8 ns is appropriate for short compensation intervals rather than long cable-delay emulation. Place the device where the delayed clock and data routes maintain matched impedance and controlled return paths. The exposed pad should be tied and thermally coupled according to the manufacturer layout guidance, while short control traces reduce the chance that programming transitions create unintended coupling into the timing output.
Recommandé
Communications Signal Conditioning
The SY89296UMI can add controlled propagation delay to communications signals when transmitters, receivers, or switching networks require skew management. Its 3.2 ns to 14.8 ns range covers compact timing-compensation requirements, while the 10 ps tap increment supports incremental alignment of related outputs. The part is most useful where a delay value must be changed during calibration or where fixed passive delays occupy too much board area. Designers should characterize insertion delay, output jitter, and control settling for the operating frequency. Keep the delay device close to the receiving circuitry when propagation matching matters, and isolate high-energy switching traces from the clock and control paths to preserve timing margin.
Recommandé
Pulse Qualification and Debounce
The SY89296UMI is suitable for pulse-qualification and debounce circuits requiring an adjustable interval between an incoming transition and the corresponding delayed output. Its 1024-step organization allows timing to be tuned in 10 ps increments within a 3.2 ns to 14.8 ns range, which can help resolve narrow timing relationships in control and instrumentation systems. The implementation should define the required pulse width, response polarity, and maximum acceptable latency before programming the device. Use short and shielded control traces, maintain a stable reference ground, and decouple the 2.375 V to 3.6 V supply close to the package to prevent supply disturbances from changing the timing behavior.
Recommandé
Test and Measurement Instrumentation
The SY89296UMI supports precision test and measurement systems that need repeatable, adjustable delay between trigger, sampling, or acquisition paths. A 10 ps tap increment can represent fine calibration offsets, while the 3.2 ns to 14.8 ns range covers compact timing relationships encountered in high-speed test fixtures. Calibration can be stored as a tap index and reapplied during production to improve fixture-to-fixture consistency. For best results, isolate the delay path from fixture reflections and provide a low-noise, decoupled supply. The timing budget should include device delay tolerance, control settling, clock jitter, and the variation introduced by connectors or cables rather than relying on the nominal tap increment alone.
Recommandé
Synchronous Interface Compensation
The SY89296UMI can compensate short propagation differences in synchronous interfaces where source and destination timing must be adjusted independently. Its programmable taps permit calibration without changing a board's physical trace length, while the 32-VFQFN exposed-pad package supports compact placement next to the receiving logic. Engineers should verify output transition timing, input threshold requirements, and control setup constraints for their specific interface. Route the delayed signal over a continuous reference plane and keep the programming interface away from the timing path. The device's 2.375 V to 3.6 V operating range must also match the interface's supply level, and suitable local decoupling should minimize supply-coupled jitter.
Recommandé
Industrial Timing Control
The SY89296UMI can be used in industrial timing-control modules where different sensor, actuator, or communication paths require adjustable alignment. Its 1024 taps provide fine calibration over 3.2 ns to 14.8 ns, allowing a controller to compensate for component and routing variation during production. The -40 °C to +85 °C operating range supports many industrial environments, although the complete enclosure temperature and the device's thermal behavior must be checked. Use the exposed pad to lower junction temperature and maintain supply integrity across temperature. Programming should occur only when the interface is inactive if the control architecture requires it, and the system should include a deterministic fallback delay when the control value is invalid.
Recommandé
Récapitulatif des produits recommandés
Données de référence d'ingénierie pour SY89296UMI — comparaison, recommandations de conception et informations de conformité.
Guide de sélection
Notes de conception
Follow the manufacturer land pattern for the 32-VFQFN exposed-pad package and connect the exposed pad to its specified pad net. Provide a continuous ground or return-plane connection beneath the device, using short thermal-via transitions where the board construction permits. Place supply-decoupling capacitors close to the associated supply and ground pins, and route control and clock inputs away from switch-node and high-current traces.
Treat the delay path as a timing-sensitive route even though the programmed interval is numerically precise. Match the input and output trace characteristics, avoid stubs and test pads where reflections could affect transitions, and keep the ground reference continuous beneath the timing nets. Program-control traces should be short and separated from the delayed output to minimize unintended coupling into the timing signal.
Operate the SY89296UMI only within its 2.375 V to 3.6 V supply range and confirm that connected I/O levels are compatible with the device's thresholds. Place local decoupling at the package pins and verify supply ripple, clock jitter, and power-up behavior in the final board. Because exact current and decoupling requirements are not listed on the product page, use the manufacturer datasheet before finalizing capacitor values.
Informations de conformité
No specific RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals declaration was identified for the exact MPN. Confirm compliance documentation with the manufacturer during procurement.