Microchip Technology

SY89296UMI - 1024-Tap Programmable Delay Line | Microchip

MPN: SY89296UMI ✓ Aktif
2.375 V to 3.6 V Vdss 32-pin VFQFN with exposed pad Package
MOQ: 1 |

SY89296UMI Ringkasan

The Microchip Technology SY89296UMI is a Precision Edge programmable delay line featuring 1024 taps, a 10 ps tap increment, and a programmable delay range of 3.2 ns to 14.8 ns. It operates from a 2.375 V to 3.6 V supply and is packaged in a 32-pin VFQFN surface-mount package with an exposed pad.

A programmable delay line is a clock-and-timing semiconductor that inserts a controlled interval between an input transition and an output transition. It belongs to the delay-line and timing-element hierarchy, where adjustable propagation delay supports calibration, trigger alignment, data acquisition, communications timing, and signal-conditioning applications. The SY89296UMI converts a programmable digital control into a fine-resolution delay across 1024 available taps.

The principal features include 1024 programmable taps, a 10 ps increment per tap, a 3.2 ns minimum programmed delay, a 14.8 ns maximum programmed delay, and a 2.375 V to 3.6 V operating supply range. Its exposed-pad VFQFN construction supports heat dissipation through the PCB copper area, while the surface-mount format reduces board area compared with many older delay packages.

The delay is established from the device's 1024-tap organization rather than through an external timing network. A 10 ps tap increment provides substantially finer control than coarse selectable-delay devices, allowing calibration or timing compensation to be adjusted in regular steps. The 3.2 ns to 14.8 ns range covers short propagation intervals suitable for precision synchronization, pulse qualification, and embedded timing correction.

Typical uses include clock and data capture systems, communications interface timing, pulse-generation and debounce circuits, test and measurement instrumentation, and clock-alignment networks. In these systems, the device can compensate for propagation differences introduced by external circuitry or provide a controlled delay between related signals.

PCB layout should preserve a continuous return path beneath the exposed pad and minimize sensitive timing traces near high-current switching nodes. Decoupling capacitors should be placed close to the supply and ground pins, while the control interface traces should be kept short to reduce control-timing skew. The device requires careful review of its pin description, control-code table, supply requirements, and timing characteristics before layout release.

This page combines the exact orderable MPN, programming details, package information, application guidance, replacement criteria, and engineering design notes needed to evaluate the SY89296UMI as a precision timing component.

Pilihan pengganti yang segera untuk SY89296UMI — sama paket, pin-pin kompatibel. Bahagian paket yang berbeza memerlukan kerja ulang PCB diasingkan.

Tiada pilihan pengganti yang segera untuk produk ini.

Minta Alternatif

SY89296UMI Spesifikasi

Product Type Programmable delay line IC
Product Series Precision Edge SY89296U
Number of Taps 1024 taps
Tap Increment 10 ps
Programmable Delay Range 3.2 ns to 14.8 ns
Minimum Delay to First Tap 3.2 ns
Supply Voltage Range 2.375 V to 3.6 V
Gambaran Suhu Operasi -40 °C to +85 °C
Kemasan 32-pin VFQFN with exposed pad
Package Code 32-MLF
Jenis Pemasangan Surface mount

Panduan Konfigurasi Pin SY89296UMI 32-mlf

Konfigurasi pin untuk SY89296UMI (32-mlf pakai). Penomeran pin, fungsi, dan garis bentuk koneksi ditakrifkan dalam dokumen pengeluar. Rujuk dokumen untuk kebentuk dan pedoman pengasman.

Garis bentuk pengecah pakai 32-mlf untuk SY89296UMI

Tiada data garisan pin yang diperoleh untuk SY89296UMI.

Rujuk kepada lembaran data untuk konfigurasi pin penuh.

Aplikasi Biasa

SY89296UMI patut untuk 6 aplikasis: Clock and Data Alignment, Communications Signal Conditioning, Pulse Qualification and Debounce, Test and Measurement Instrumentation, Synchronous Interface Compensation, Industrial Timing Control.

🌐

Clock and Data Alignment

The SY89296UMI fits clock-and-data alignment networks that require fine, digitally adjustable propagation delay. Its 1024 taps and 10 ps increment let a system correct small timing offsets introduced by board traces, connectors, cables, or adjacent logic without changing discrete delay components. The selectable range of 3.2 ns to 14.8 ns is appropriate for short compensation intervals rather than long cable-delay emulation. Place the device where the delayed clock and data routes maintain matched impedance and controlled return paths. The exposed pad should be tied and thermally coupled according to the manufacturer layout guidance, while short control traces reduce the chance that programming transitions create unintended coupling into the timing output.

📡

Communications Signal Conditioning

The SY89296UMI can add controlled propagation delay to communications signals when transmitters, receivers, or switching networks require skew management. Its 3.2 ns to 14.8 ns range covers compact timing-compensation requirements, while the 10 ps tap increment supports incremental alignment of related outputs. The part is most useful where a delay value must be changed during calibration or where fixed passive delays occupy too much board area. Designers should characterize insertion delay, output jitter, and control settling for the operating frequency. Keep the delay device close to the receiving circuitry when propagation matching matters, and isolate high-energy switching traces from the clock and control paths to preserve timing margin.

⚡

Pulse Qualification and Debounce

The SY89296UMI is suitable for pulse-qualification and debounce circuits requiring an adjustable interval between an incoming transition and the corresponding delayed output. Its 1024-step organization allows timing to be tuned in 10 ps increments within a 3.2 ns to 14.8 ns range, which can help resolve narrow timing relationships in control and instrumentation systems. The implementation should define the required pulse width, response polarity, and maximum acceptable latency before programming the device. Use short and shielded control traces, maintain a stable reference ground, and decouple the 2.375 V to 3.6 V supply close to the package to prevent supply disturbances from changing the timing behavior.

🖥️

Test and Measurement Instrumentation

The SY89296UMI supports precision test and measurement systems that need repeatable, adjustable delay between trigger, sampling, or acquisition paths. A 10 ps tap increment can represent fine calibration offsets, while the 3.2 ns to 14.8 ns range covers compact timing relationships encountered in high-speed test fixtures. Calibration can be stored as a tap index and reapplied during production to improve fixture-to-fixture consistency. For best results, isolate the delay path from fixture reflections and provide a low-noise, decoupled supply. The timing budget should include device delay tolerance, control settling, clock jitter, and the variation introduced by connectors or cables rather than relying on the nominal tap increment alone.

🔧

Synchronous Interface Compensation

The SY89296UMI can compensate short propagation differences in synchronous interfaces where source and destination timing must be adjusted independently. Its programmable taps permit calibration without changing a board's physical trace length, while the 32-VFQFN exposed-pad package supports compact placement next to the receiving logic. Engineers should verify output transition timing, input threshold requirements, and control setup constraints for their specific interface. Route the delayed signal over a continuous reference plane and keep the programming interface away from the timing path. The device's 2.375 V to 3.6 V operating range must also match the interface's supply level, and suitable local decoupling should minimize supply-coupled jitter.

🏭

Industrial Timing Control

The SY89296UMI can be used in industrial timing-control modules where different sensor, actuator, or communication paths require adjustable alignment. Its 1024 taps provide fine calibration over 3.2 ns to 14.8 ns, allowing a controller to compensate for component and routing variation during production. The -40 °C to +85 °C operating range supports many industrial environments, although the complete enclosure temperature and the device's thermal behavior must be checked. Use the exposed pad to lower junction temperature and maintain supply integrity across temperature. Programming should occur only when the interface is inactive if the control architecture requires it, and the system should include a deterministic fallback delay when the control value is invalid.

Ringkasan Produk Disebarkan

SY89296U Precision Edge programmable delay-line series Dipergunakan di: Clock and Data Alignment, Communications Signal Conditioning, Pulse Qualification and Debounce, Test and Measurement Instrumentation, Synchronous Interface Compensation, Industrial Timing Control SY89296 Base family designation Dipergunakan di: Clock and Data Alignment, Communications Signal Conditioning, Pulse Qualification and Debounce, Test and Measurement Instrumentation, Synchronous Interface Compensation, Industrial Timing Control
What is the SY89296UMI?
The SY89296UMI is a Microchip Technology Precision Edge programmable delay line with 1024 taps and a 3.2 ns to 14.8 ns delay range. According to the manufacturer's product information, the tap increment is 10 ps, and the device is supplied in a 32-pin VFQFN package with an exposed pad. It is designed for precision clock alignment, pulse timing, and communications signal conditioning.
How many taps and what delay range does SY89296UMI provide?
The SY89296UMI provides 1024 programmable taps across a 3.2 ns to 14.8 ns delay range. The manufacturer identifies a 10 ps increment per tap, allowing delay to be selected in fine, regular steps. This resolution is useful when a system must align a clock or data signal with picosecond-scale timing adjustments rather than coarse fixed-delay intervals.
What is the operating voltage of SY89296UMI?
The SY89296UMI operates from 2.375 V to 3.6 V. The manufacturer product listing identifies this supply range, while the device also appears in a 32-MLF VFQFN package with an exposed pad. The power rails and I/O thresholds should be checked against the circuit that drives the delay-control and clock signals before implementation.
Where can I find the SY89296UMI datasheet and pinout?
The SY89296UMI manufacturer product page is available at the datasheet link on this page, and the package is a 32-pin VFQFN with an exposed pad. Use the manufacturer's pin-description table and connection diagram when assigning pins and PCB tracks. The exact signal names for all 32 pins should be taken from that table because they are not reproduced here.
What can replace the SY89296UMI?
A true drop-in replacement for the SY89296UMI must use the same 32-pin VFQFN footprint, preserve pin-to-pin signal assignments, and match the 1024-tap organization, 3.2 ns to 14.8 ns range, 10 ps increment, and 2.375 V to 3.6 V supply requirements. The cross-reference results did not identify a confirmed interchangeable part, so use the Microchip cross-reference search and compare the complete pin and timing tables before approving a substitute.
Is the SY89296UMI the same as the SY89296U series?
The SY89296UMI is an orderable member of the Microchip SY89296U Precision Edge delay-line series. The family description identifies programmable delay-line functionality, 1024 taps, a 10 ps tap increment, and a 3.2 ns to 14.8 ns range. Package, temperature, and order-code differences should still be checked for each exact suffix before treating another family member as interchangeable.
Where can I buy SY89296UMI online?
Use the Request a Quote form on this page to request SY89296UMI availability, order quantity, and lead time. The form provides a direct purchasing route for the exact 32-VFQFN orderable MPN. Stock status can change rapidly, so confirm the quantity, suffix, and manufacturing traceability with the supplier when the quotation is returned.
What is the price of SY89296UMI?
Current commercial terms for the SY89296UMI should be obtained through the Request a Quote form on this page. The quote should identify the exact 32-MLF orderable MPN, quantity, packaging, and any required traceability documentation. This avoids relying on a stale catalog amount when availability or volume requirements may have changed.
What is the lead time for SY89296UMI?
The current lead time for SY89296UMI should be requested through the Request a Quote form on this page. Include the required order quantity, target date, and whether the shipment must be in the manufacturer's standard 32-MLF packaging. The form allows purchasing to confirm current manufacturing and allocation status for the exact MPN.
Is SY89296UMI in stock?
Use the Request a Quote form on this page to check current SY89296UMI stock and allocation status. Availability depends on quantity and replenishment conditions, so a general catalog indication should not be treated as a firm allocation. The request should specify the required order quantity and target delivery schedule.
When should I choose the SY89296UMI for a timing circuit?
Choose the SY89296UMI when a design needs fine delay adjustment in 10 ps increments across a 3.2 ns to 14.8 ns range. Its 1024-tap control makes it appropriate for clock alignment, calibration, pulse qualification, and short propagation-delay compensation. It is less suitable when a much longer delay, a different supply range, or a different package is required.
Is SY89296UMI suitable for clock and data alignment?
Yes, the SY89296UMI is suitable for short clock-and-data alignment intervals because it provides 1024 taps and a 3.2 ns to 14.8 ns programmable range. The 10 ps tap increment permits fine correction of propagation differences in acquisition, communications, and synchronization systems. Validate the control settling behavior and output timing against the system budget before finalizing the design.
How do I select a drop-in alternative to SY89296UMI?
Select a SY89296UMI alternative only when its pinout, 32-VFQFN exposed-pad footprint, 1024-tap control interface, 3.2 ns to 14.8 ns delay range, 10 ps tap increment, and 2.375 V to 3.6 V supply operation match. A matching package alone is insufficient because control-code or timing differences can prevent operation. Use the Microchip cross-reference search and compare every assigned pin and timing parameter.
What are the key specifications of SY89296UMI that engineers should know?
The key SY89296UMI specifications are 1024 programmable taps, a 10 ps tap increment, a 3.2 ns to 14.8 ns delay range, a 2.375 V to 3.6 V supply range, and a -40 °C to +85 °C operating range. The device is packaged in a 32-pin VFQFN with an exposed pad. Its principal engineering value is fine-grained, digitally adjustable propagation delay in a compact surface-mount package.
Does SY89296UMI need special PCB layout for its exposed pad?
The SY89296UMI should be laid out with its exposed pad connected to the device's specified ground or pad-net assignment, with a continuous thermal and electrical return path through PCB copper. Place input, output, control, and decoupling connections close to their associated pins, and avoid routing timing-sensitive traces beside fast-switching nodes. The manufacturer pin and land-pattern instructions govern the final footprint.

Data referensi kejuruteraan untuk SY89296UMI — perbandingan, panduan rancangan, dan maklumat kesediaan

Panduan Pilihan

Choose the SY89296UMI when a compact timing circuit requires digitally adjustable delay with 1024 taps, a 10 ps increment, and a 3.2 ns to 14.8 ns range. It is well suited to clock alignment, short propagation compensation, communications timing, pulse qualification, and test fixtures where fine calibration is valuable. The 32-VFQFN exposed-pad package supports space-constrained surface-mount designs and provides an effective thermal path when the PCB is laid out correctly. Do not select it for long-delay networks, incompatible supply levels, or applications requiring a larger package and broader delay range. A replacement should be approved only after its pin assignments, exposed-pad net, programming codes, delay resolution, timing tolerance, supply range, and temperature limits have been compared with the SY89296UMI.

Catatan Desain

Follow the manufacturer land pattern for the 32-VFQFN exposed-pad package and connect the exposed pad to its specified pad net. Provide a continuous ground or return-plane connection beneath the device, using short thermal-via transitions where the board construction permits. Place supply-decoupling capacitors close to the associated supply and ground pins, and route control and clock inputs away from switch-node and high-current traces.

Treat the delay path as a timing-sensitive route even though the programmed interval is numerically precise. Match the input and output trace characteristics, avoid stubs and test pads where reflections could affect transitions, and keep the ground reference continuous beneath the timing nets. Program-control traces should be short and separated from the delayed output to minimize unintended coupling into the timing signal.

Operate the SY89296UMI only within its 2.375 V to 3.6 V supply range and confirm that connected I/O levels are compatible with the device's thresholds. Place local decoupling at the package pins and verify supply ripple, clock jitter, and power-up behavior in the final board. Because exact current and decoupling requirements are not listed on the product page, use the manufacturer datasheet before finalizing capacitor values.

Maklumat Kesediaan

RoHS
Unknown
REACH
Unknown
AEC-Q100
Unknown
Bosong logam timbal
Unknown
Bosong halogen
Unknown
Mineral konflik
Unknown

No specific RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals declaration was identified for the exact MPN. Confirm compliance documentation with the manufacturer during procurement.

Data disahkan pada: 2026-11-16 — data yang disahkan dan disusun semula oleh pasukan kejuruteraan komponen XAIPART

Pencarian Berhubungan

SY89296UMI datasheet SY89296UMI pinout SY89296UMI specifications SY89296UMI 1024 tap delay line SY89296UMI 32 VFQFN SY89296UMI replacement SY89296UMI equivalent SY89296UMI price SY89296UMI stock Microchip SY89296UMI

Komponen dan Tanda berkaitan

Microchip Technology SY89296UMI SY89296U SY89296 Precision Edge programmable delay line delay line IC timing element clock and timing IC integrated circuit semiconductor 1024 taps 10 ps tap increment 3.2 ns minimum delay 14.8 ns maximum delay 32-VFQFN 32-MLF QFN family surface-mount package exposed pad clock alignment communications timing pulse qualification test and measurement 2.375 V to 3.6 V supply
RFRC Saring Pantas
Isikan butiran lengkap — pasukan jualan kami akan bertindak balas dalam masa 24 jam
Nombor Bahagian Pengeluar Pakej QTY Harga Target Lengkap
✓
Pesan diskon sudah disubmit!

Kami akan bertindak balas kepada emel anda dalam tempoh 24 jam

1
RFQ Diserahkan
2
kutipan Diterima
3
Order Dipesan
4
Pembayaran
5
Dihantar
6
Diantar
Lihat Perincian RFQ