TIOL221RGER Présentation

The Texas Instruments TIOL221RGER is a dual-channel IO-Link device physical layer (PHY) transceiver integrating two low-power output drivers with active reverse polarity protection, an integrated LDO, and an SPI interface in a 24-pin VQFN (4x4 mm) package. It provides a complete physical layer for IO-Link communication over a three-wire interface for industrial sensors and actuators.

An IO-Link transceiver is a specialized interface IC that bridges a local microcontroller to the IO-Link communication standard, enabling point-to-point communication between sensors or actuators and an IO-Link master. It converts MCU digital data into IO-Link physical layer signals on the CQ line and vice versa while adding power management and protection. In the component hierarchy it sits as: IO-Link PHY -> industrial communication interface -> sensor interface IC -> mixed-signal semiconductor.

Key features include dual-channel operation for two independent IO-Link ports in one package, an integrated LDO that simplifies power design, SPI-based configuration and diagnostics, and wake-up support: the device can sink or source at least 500 mA for the wake-up duration (typically 80 microseconds) depending on the CQ logic level, then asserts the WU pin low for tWUL to notify the local MCU. Surge robustness reaches 1.2 kV (500 ohm) per IEC 61000-4-5.

Technically, the TIOL221 provides fault reporting and internal protection for undervoltage, overcurrent, and overtemperature conditions, and can be configured to generate wake-up pulses, also supporting IO-Link master applications. An auxiliary DI channel adds digital input functionality. Active reverse polarity protection removes the need for external series diodes, reducing voltage drop and bill-of-material cost.

Typical applications include industrial proximity, pressure, and temperature sensors, actuators, and IO-Link master port circuitry. The dual-channel capability halves board area versus two single-channel PHYs.

Design tip: decouple the integrated LDO carefully and configure wake-up timing per the IO-Link specification; external TVS diodes may still be needed for surge levels beyond the built-in protection.

Alternatives de remplacement direct pour TIOL221RGER — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.

Outil de comparaison rapide — sélectionnez des références alternatives pour une comparaison côte à côte :

TIOL1125

⚡ Même boîtier
Texas Instruments
📦 VQFN (RGE)
IO-Link device transceiver with 5-V LDO · 7 V to 36 V · 5 V · 0.5 V typical at 200 mA · PNP, NPN, or IO-Link configurable · COM1 (4.8 kbps), COM2 (38.4 kbps), COM3 (230.4 kbps) · IEC 61131-9 IO-Link physical layer · Integrated

✓ En stock

$1.29 / unité

Voir la fiche technique →

TIOL1115RGER

⚡ Même boîtier ⚠️ Spécifications non vérifiées
📦 24-VQFN (RGE)
single-channel IO-Link PHY in same RGE 4x4mm footprint family; one CQ port instead of two

📋 Alternative de référence (hors catalogue)

ℹ️ 1 référence(s) à boîtier différent masquée(s) — un boîtier différent exige une retouche du PCB et ne constitue pas un remplacement direct. Contactez-nous si vous souhaitez des suggestions de boîtiers équivalents.

TIOL221RGER Spécifications

Fonction Dual-channel IO-Link device PHY transceiver
Canaux 2 (Tx/Rx) plus auxiliary DI
Protocol IO-Link (three-wire interface)
Integrated LDO Yes
Control Interface SPI
Wake-Up Current Capability >= 500 mA (typ. 80 us duration)
Wake-Up Pulse Generation Yes, configurable
Surge Immunity 1.2 kV (500 ohm) per IEC 61000-4-5
Protection Features Reverse polarity (active), undervoltage, overcurrent, overtemperature
IO-Link Master Support Yes
Boîtier 24-VQFN (4x4 mm), RGE
Type de montage Surface Mount
Statut RoHS Compliant

Configuration des broches de TIOL221RGER

Generic Component Pin Configuration Generic integrated-circuit pinout placeholder. Pin 1 indicated by dot; exact pin count and functions in the pin table below. 1 N 2 N-1 3 N-2 4 N-3 Pin Configuration See pin table below for pin functions Package-specific diagram not available
Broche [DATA_NEEDED] LDO_OUT — Integrated LDO output powering internal logic and external MCU
Broche [DATA_NEEDED] VDD — Supply input from IO-Link L+ line
Broche [DATA_NEEDED] CQ1 — Channel 1 CQ line driver/receiver
Broche [DATA_NEEDED] CQ2 — Channel 2 CQ line driver/receiver
Broche [DATA_NEEDED] WU — Wake-up indicator to MCU (asserted low for tWUL)
Broche [DATA_NEEDED] DI — Auxiliary digital input channel
Broche [DATA_NEEDED] SPI (CS/SCLK/MOSI/MISO) — SPI configuration and diagnostics interface
Broche [DATA_NEEDED] GND — Ground

Applications typiques

TIOL221RGER convient pour 6 applications: Industrial Proximity Sensors, IO-Link Master Stations, Pressure and Temperature Sensor Nodes, Actuator Control Modules, Motor Feedback and Encoder Interfaces, IIoT Sensor Hubs and Gateways.

🏭

Industrial Proximity Sensors

The TIOL221 fits IO-Link proximity sensor nodes because its dual low-power output drivers drive the three-wire L+/CQ interface directly while its active reverse polarity protection survives miswiring during installation. The >= 500 mA wake-up capability for ~80 microseconds meets IO-Link wake requirements without external power switches. The integrated LDO powers the sensor MCU from the 24V industrial rail, and the auxiliary DI channel can read a second sensor element, reducing external logic. Surge robustness of 1.2 kV (500 ohm) per IEC 61000-4-5 addresses cable-borne transients common on factory floors.

🌐

IO-Link Master Stations

The TIOL221 can be used in IO-Link master applications: it is configured to generate wake-up pulses, sinking or sourcing at least 500 mA for the typical 80 microsecond wake duration depending on CQ logic level. Two integrated channels let a master board drive two ports with one IC, halving PHY area versus discrete solutions. SPI control lets a host MCU configure each port independently and read fault status (undervoltage, overcurrent, overtemperature). Active reverse polarity protection protects master ports against field miswiring, improving mean time between failures in modular I/O systems.

🧩

Pressure and Temperature Sensor Nodes

For smart pressure and temperature transmitters, the TIOL221 provides the complete IO-Link physical layer: it converts MCU SPI-configured data to CQ-line signaling and reports wake events via the WU pin for tWUL. The integrated LDO derives low-noise logic power from the 24V line, and built-in overcurrent and overtemperature protection guards against shorted field cables. Designers pair the PHY with a precision ADC and MCU; the PHY's fault reporting lets the transmitter firmware flag diagnostic codes back to the PLC via IO-Link, supporting predictive maintenance schemes required in process industries.

🔧

Actuator Control Modules

Pneumatic valves, solenoids, and indicator actuators over IO-Link use the TIOL221's drivers to switch the CQ line between logic levels while its >= 500 mA capability covers the inrush of wake pulses. The SPI interface enables per-port configuration of driver modes and real-time diagnostics, letting the controller detect open-wire or overtemperature faults and report them per IO-Link ISDU parameters. Dual channels allow one IC to control two actuator ports in compact valve manifolds. The active reverse polarity protection is valuable in panel wiring where supply polarity errors occur during commissioning.

⚙️

Motor Feedback and Encoder Interfaces

Industrial encoders with IO-Link interfaces benefit from the TIOL221's robust PHY: 1.2 kV (500 ohm) surge immunity per IEC 61000-4-5 handles transients on long motor cables, and the undervoltage lockout prevents corrupted transmissions during brownouts. The device acts as the complete physical layer between the encoder ASIC/MCU and the three-wire IO-Link port, with the WU output letting encoder firmware wake from sleep on master requests to minimize power. The dual-channel version also supports auxiliary output signals alongside the IO-Link channel in hybrid encoder designs.

🖥️

IIoT Sensor Hubs and Gateways

In Industry 4.0 gateways aggregating multiple IO-Link devices, the TIOL221's dual channels reduce PHY component count: four ICs provide eight ports versus eight single-channel PHYs, cutting board area and cost. SPI bus configuration allows a central MCU to manage all PHYs and poll fault registers over the same SPI lines. Integrated protection (overcurrent, overtemperature, reverse polarity) plus 1.2 kV surge robustness suits the electrically noisy environments of dense industrial cabinets. The TIOL221EVM accelerates firmware bring-up of multi-port gateway designs before custom hardware.

Récapitulatif des produits recommandés

TPS7A78 Texas Instruments Utilisé dans : Industrial Proximity Sensors TLV3502 Texas Instruments Utilisé dans : Industrial Proximity Sensors TMUX8108 Texas Instruments Utilisé dans : IO-Link Master Stations ISO7742-Q1 Galvanic isolation for master port isolation Utilisé dans : IO-Link Master Stations ADS1220 Texas Instruments Utilisé dans : Pressure and Temperature Sensor Nodes MSPM0G3207 Sensor node microcontroller Utilisé dans : Pressure and Temperature Sensor Nodes TPS2054 Texas Instruments Utilisé dans : Actuator Control Modules UCC27511A Texas Instruments Utilisé dans : Actuator Control Modules TMS320F28034 C2000 MCU for motor control feedback processing Utilisé dans : Motor Feedback and Encoder Interfaces AM263P4 Sitara MCU for industrial gateway control Utilisé dans : IIoT Sensor Hubs and Gateways ISO1050QDUBRQ1 Texas Instruments Utilisé dans : IIoT Sensor Hubs and Gateways
What is the TIOL221?
The TIOL221 is a dual-channel IO-Link device physical layer (PHY) transceiver from Texas Instruments with an integrated LDO and SPI interface. It integrates dual low-power output drivers with active reverse polarity protection, provides fault reporting for undervoltage, overcurrent, and overtemperature conditions, and withstands 1.2 kV (500 ohm) surge per IEC 61000-4-5, per the TI datasheet.
What package does the TIOL221 come in?
The TIOL221 comes in a 24-pin VQFN (RGE) package measuring 4x4 mm. The TIOL221RGER is the tape-and-reel ordering part; DigiKey lists it as '2/2 Transceiver Half I/O-Link 24-VQFN (4x4)'. A VQFN-24 (QFN family, SMD mounting) allows compact dual-port IO-Link designs.
What is the difference between TIOL221 and TIOL1115 / TIOL1125?
The TIOL221 is a dual-channel IO-Link device PHY with integrated LDO and SPI; the TIOL1115 and TIOL1125 are single-channel IO-Link PHYs. All serve the same IO-Link physical layer function, but the TIOL221 integrates two ports plus an auxiliary DI channel in one 24-VQFN, roughly halving board space versus two single-channel devices.
Can TIOL221 be used in IO-Link master applications?
Yes. According to the TI product page, the TIOL221 can be configured to generate wake-up pulses and be used in IO-Link master applications. The device sinks or sources at least 500 mA for the wake-up duration (typically 80 microseconds) depending on the CQ logic level, meeting IO-Link master-side wake requirements.
How does TIOL221 wake-up detection work?
The TIOL221 detects a wake-up condition and signals the local microcontroller by asserting the WU pin low for the duration of tWUL. Per the TI datasheet, the device either sinks or sources current (>= 500 mA) for the wake-up duration, typically 80 microseconds, depending on the CQ logic level, in accordance with the IO-Link specification.
What protection features does the TIOL221 integrate?
The TIOL221 integrates active reverse polarity protection plus internal undervoltage, overcurrent, and overtemperature protection with fault reporting. It also withstands 1.2 kV (500 ohm) surge per IEC 61000-4-5. Active reverse polarity protection eliminates the external series diode used in discrete designs, reducing voltage drop and component count.
What are the key specifications of TIOL221RGER engineers should know?
Key facts: dual-channel IO-Link device PHY; integrated LDO; SPI configuration/diagnostics interface; wake-up capability of >= 500 mA for ~80 microseconds; 1.2 kV (500 ohm) surge per IEC 61000-4-5; undervoltage, overcurrent, overtemperature, and active reverse-polarity protection; auxiliary DI channel; 24-VQFN 4x4 mm package. Source: TI TIOL221 datasheet (SBVS...) and TI product page.
What is the best drop-in replacement for TIOL221?
There is currently no verified cross-manufacturer pin-compatible drop-in replacement for the dual-channel TIOL221 in a 24-VQFN. The closest in-family options are TI's single-channel TIOL1115 or TIOL1125, but these are functionally similar, not pin-identical dual-port replacements, so a PCB redesign would be required. Verify pinout before any substitution.
Is TIOL221 the same as TIOL1125?
No. The TIOL221 is a dual-channel device PHY with integrated LDO and SPI, while the TIOL1125 is a single-channel IO-Link device PHY with integrated LDO and I2C/SPI-style configuration. Both target IO-Link device nodes and share family protection features, but channel count and pinout differ, so they are not interchangeable.
When should I choose TIOL221 over TIOL1115?
Choose the TIOL221 when your IO-Link master or gateway needs two ports, or when you want to consolidate two single-channel PHYs (TIOL1115) into one package to save board area and BOM cost. Choose TIOL1115 for single-port sensor nodes where the dual-channel integration is unnecessary.
Where can I buy TIOL221RGER and what is the price?
TIOL221RGER is available from authorized distributors including DigiKey and Mouser, which list it as in stock and shipping today (as of 2026-08-29). Approximate pricing runs about $1.85-$3.20 depending on quantity (1 to 1000 units); check DigiKey, Mouser, or Findchips for real-time quotes.
Is there an evaluation board for TIOL221?
Yes. Texas Instruments offers the TIOL221EVM, an IO-Link interface evaluation module for the TIOL221 transceiver. It is stocked at DigiKey and other distributors (ships today as of 2026-08-29), letting engineers exercise the SPI configuration, wake-up, and driver functions before committing to PCB layout.
Where can I download the TIOL221 datasheet PDF?
The official TIOL221 datasheet PDF is available from Texas Instruments at ti.com/lit/gpn/TIOL221 (approximately 54 pages). Mirror copies exist on aggregator sites like alldatasheet.com, but always prefer the TI website for the latest revision, including pinout and wake-up timing parameters.

Données de référence d'ingénierie pour TIOL221RGER — comparaison, recommandations de conception et informations de conformité.

Guide de sélection

Choose the TIOL221RGER when your design needs two IO-Link ports - IO-Link masters, gateways, or dual-sensor nodes - because its dual channels and auxiliary DI consolidate two single-channel PHYs into one 24-VQFN package, saving board area and assembly cost. Choose the single-channel TIOL1125 (with integrated LDO) or TIOL1115 for simple single-port sensor nodes where the dual-channel integration would be wasted. There is no verified cross-brand pin-compatible dual-channel replacement as of 2026-08-29, so second-sourcing requires footprint-compatible TI family parts only. For surge environments exceeding the built-in 1.2 kV (500 ohm) IEC 61000-4-5 capability, budget external TVS protection regardless of PHY choice. All TIOL family members provide reverse polarity, overcurrent, overtemperature, and undervoltage protection; select based on channel count and control interface (SPI on TIOL221 vs simpler control on TIOL1115).

Comparaison avec les alternatives

Paramètre Ce produit TIOL1125 TIOL1115RGER TIOL1115DMRR
Package 24-VQFN (4x4 mm) VQFN (RGE) family 24-VQFN (4x4 mm) SON-8
Brand Texas Instruments Texas Instruments Texas Instruments Texas Instruments
Channels 2 (dual) + auxiliary DI 1 1 1
Integrated LDO Yes Yes Yes Yes
Configuration Interface SPI SPI/I2C-style per datasheet UART/parallel control UART/parallel control

Principaux différenciateurs

  • Dual-channel integration (vs TIOL1115RGER)
  • SPI-based configuration and diagnostics (vs TIOL1115DMRR)
  • Integrated LDO plus active reverse polarity protection (vs TIOL1125)

Notes de conception

Decouple the integrated LDO output with local ceramic capacitance per the TI TIOL221 datasheet and keep the LDO output trace short to the MCU supply pin. The PHY drives >= 500 mA wake pulses on CQ, so bulk capacitance on the L+ supply input must sustain the ~80 microsecond wake current without drooping below undervoltage thresholds, or false fault flags may occur.

Place the TIOL221 close to the IO-Link connector with a solid ground return for the CQ lines. Keep SPI traces short and route away from CQ switching paths. Although the device tolerates 1.2 kV (500 ohm) surge per IEC 61000-4-5, add external TVS diodes on L+ and CQ when the installation demands higher surge levels than the built-in protection.

Configure wake-up timing parameters (tWUL and the ~80 microsecond wake duration) per the IO-Link specification through the SPI interface; default register settings may not match your master or device role. Remember that wake current polarity depends on CQ logic level - sink or source mode must match your port wiring, or wake detection will fail.

Informations de conformité

RoHS
Compliant
REACH
Unknown
AEC-Q100
Not Applicable
Sans plomb
Yes
Sans halogène
Unknown
Minerais de conflit
Unknown

RoHS compliance per DigiKey/TI listings for TIOL221RGER. REACH and halogen-free status not stated in provided data.

Données vérifiées le : 2026-08-29 — données vérifiées et sélectionnées par l'équipe d'ingénierie composants de XAIPART

Recherches associées

TIOL221RGER TIOL221 datasheet PDF Texas Instruments TIOL221 dual channel IO-Link transceiver IC IO-Link PHY VQFN-24 4x4 TIOL221 vs TIOL1115 TIOL221 equivalent replacement TIOL221 IO-Link master wake-up pulse TIOL221RGER price buy IO-Link sensor interface IC with LDO and SPI what is TIOL221 used for TIOL221EVM evaluation board

Composants & termes associés

Texas Instruments TIOL221 TIOL221RGER TIOL221EVM TIOL1115 TIOL1125 IO-Link PHY IO-Link master transceiver integrated LDO SPI interface IEC 61000-4-5 RoHS 24-VQFN QFN family surface mount wake-up pulse reverse polarity protection overcurrent protection industrial sensors actuators
Guides techniques associés
TIOL221RGER PHY IO-Link double canal : guide technique complet, caractéristiques et guide d'achat (2026)
TIOL221RGER : PHY IO-Link double canal de TI avec LDO intégré, SPI, réveil ≥500 mA, surtension 1,2 kV (IEC 61000-4-5), 24-VQFN 4x4 mm. En st
8 min de lecture
RFQ de devis rapide
Renseignez tous les détails — notre équipe commerciale vous répondra sous 24 heures
Référence Fabricant Boîtier QTY Prix cible Total
Total : 0,00 USD
✓
Devis envoyé !

Nous répondrons à votre e-mail sous 24 heures

1
RFQ envoyée
2
Devis reçu
3
Commande passée
4
Paiement
5
Expédié
6
Livré
Voir les détails de la RFQ