VSC7155XVU-02 - 18-PHY SAS Edge/Fanout Expander | Analog Devices
Référence : VSC7155XVU-02 ✓ ActifVSC7155XVU-02 Présentation
A SAS expander is a semiconductor interface controller that enables one host-side connection to fan out to multiple SAS devices or expander nodes. Such devices simplify backplane topology by replacing a large number of point-to-point host links with shared physical-layer resources. The VSC7155XVU-02 sits within this interface-expansion layer, between SAS initiators, expanders, and attached storage targets.
The controller provides 18 physical PHYs, 1.5 Gbps and 3.0 Gbps data-rate capability, table-based routing, and an SSP engine. These features support scalable SAS edge and fanout architectures where link consolidation, device discovery, and controlled traffic distribution are important. The 18-PHY arrangement allows a single package to manage numerous SAS connections while reducing the number of separate interface controllers required by a system.
SAS physical-layer expansion is particularly useful in storage systems that must balance density, cable reach, and failure isolation. Table routing organizes communication among attached nodes, while the SSP engine provides dedicated processing for Serial SCSI Protocol operations. In a well-balanced system, these functions allow initiator traffic to reach storage targets without requiring every target to connect directly to the host controller.
Typical applications include SAS storage backplanes, edge expanders, fanout enclosures, data-center storage subsystems, and industrial systems using Serial ATA or SAS connectivity. The controller is also relevant to equipment requiring multiple serialized storage links, provided that the system-level cable, connector, power, and signal-integrity requirements are designed around the supported SAS data rates.
For implementation, preserve controlled-impedance routing for high-speed SAS links and minimize discontinuities between the controller, connector, and cable path. Follow the manufacturer's reference design for layer transitions, reference-plane construction, via geometry, and decoupling. Confirm the exact exposed-pad, lead, and thermal requirements against the package drawing before layout release.
This product overview combines the documented 18-PHY, 1.5 Gbps, 3.0 Gbps, table-routing, and SSP-engine characteristics with practical guidance for package identification, board layout, thermal management, and drop-in replacement assessment.
Alternatives de remplacement direct pour VSC7155XVU-02 — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.
VSC7155XVU-01
✅ Remplacement direct ⚠️ Spécifications non vérifiées📋 Alternative de référence (hors catalogue)
VSC7155XVU-03
✅ Remplacement direct ⚠️ Spécifications non vérifiées📋 Alternative de référence (hors catalogue)
VSC7155XVU-02 Spécifications
| Product Type | SAS Edge/Fanout Expander |
| Physical Layer Count | 18 PHYs |
| Supported SAS Data Rate 1 | 1.5 Gbps |
| Supported SAS Data Rate 2 | 3.0 Gbps |
| Routing Architecture | Table routing |
| Protocol Engine | SSP engine |
| Manufacturer | Analog Devices / Maxim Integrated |
| Device Classification | Interface controller / I/O expander |
| Application | SAS Edge and Fanout expansion |
| Maximum Data Rate | 3.0 Gbps |
Guide de configuration des broches du VSC7155XVU-02 standard
Configuration des broches du VSC7155XVU-02 (boîtier standard). La numérotation des broches, les fonctions et les schémas de connexion sont définis dans la fiche technique du fabricant. Consultez-la pour l'empreinte exacte et les directives de soudage.
Aucune donnée de brochage détaillée disponible pour VSC7155XVU-02.
Consultez la fiche technique pour la configuration complète des broches.
Applications typiques
VSC7155XVU-02 convient pour 6 applications: SAS Storage Backplane, SAS Fanout Enclosure, Data-Center Storage Subsystem, Industrial Storage Controller, External SAS Storage Bridge, SAS Edge Expansion Card.
SAS Storage Backplane
The VSC7155XVU-02 fits a SAS storage backplane that needs to distribute multiple serialized-storage links from a compact expander point. Its 18 PHYs provide substantial physical-layer capacity, while 1.5 Gbps and 3.0 Gbps support allows the same controller family to address two documented SAS link rates. Table routing and the SSP engine help organize communication across backplane nodes. The designer should preserve controlled-impedance paths, maintain uninterrupted reference planes, and follow the manufacturer layout guidance for connector launches, via transitions, and decoupling.
Recommandé
SAS Fanout Enclosure
The VSC7155XVU-02 is appropriate for a fanout enclosure that connects one system-side interface to several SAS targets or downstream expanders. With 18 PHYs and support for both 1.5 Gbps and 3.0 Gbps, the controller can consolidate numerous physical connections without requiring one host port per device. Table-based routing supports organized link relationships, while the SSP engine handles relevant Serial SCSI Protocol processing. Cable length, connector insertion loss, power budgeting, and system fault isolation must be evaluated together when defining enclosure capacity.
Recommandé
Data-Center Storage Subsystem
The VSC7155XVU-02 can support a data-center storage subsystem that values link consolidation and orderly device discovery. Its 18-PHY count creates a high-density expansion point, and the documented 1.5 Gbps and 3.0 Gbps rates allow design teams to match the expander to the generation of attached SAS infrastructure. Table routing simplifies topology management across shared links, while the SSP engine contributes protocol processing. At system level, verify thermal performance, power-supply headroom, fail-safe behavior, and the signal-integrity budget for each supported data rate.
Recommandé
Industrial Storage Controller
The VSC7155XVU-02 fits industrial storage controllers that need multiple SAS connections in a space-constrained embedded system. Eighteen PHYs can support dense target or expander connectivity, and operation at 1.5 Gbps or 3.0 Gbps provides options for balancing throughput against link budget. Table routing and the SSP engine support structured access across the storage fabric. Because the exact package, electrical ratings, and temperature limits must come from the manufacturer documentation, confirm those items before approving a ruggedized industrial product configuration.
Recommandé
External SAS Storage Bridge
The VSC7155XVU-02 can serve as the expansion element in an external SAS storage bridge where a host interface must reach multiple storage devices through a controlled physical layer. Its 18 PHYs provide fanout capacity, while support for 1.5 Gbps and 3.0 Gbps offers flexibility across two documented SAS generations. Table routing and the SSP engine help structure communication between the bridge and targets. Cable and connector losses, grounding, shielding, enclosure temperature, and hot-plug behavior must be addressed in the complete bridge design.
Recommandé
SAS Edge Expansion Card
The VSC7155XVU-02 is suitable for a SAS edge expansion card intended to add serialized-storage connectivity to an existing chassis or compute platform. The 18-PHY arrangement allows one card to represent multiple physical links, reducing connector pressure on the host board when designed with table routing and SSP engine support. The 1.5 Gbps and 3.0 Gbps options enable link selection according to the installed storage topology. A successful card design must preserve signal integrity across connector and PCB transitions while satisfying the manufacturer's power, grounding, and layout requirements.
Recommandé
Récapitulatif des produits recommandés
Données de référence d'ingénierie pour VSC7155XVU-02 — comparaison, recommandations de conception et informations de conformité.
Guide de sélection
Comparaison avec les alternatives
| Paramètre | Ce produit | VSC7155XVU-01 | VSC7155XVU-03 |
|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices |
| Product Type | SAS Edge/Fanout Expander | SAS Edge/Fanout Expander | SAS Edge/Fanout Expander |
| Physical Layer Count | 18 PHYs | 18 PHYs | 18 PHYs |
| Supported Data Rate 1 | 1.5 Gbps | 1.5 Gbps | 1.5 Gbps |
| Supported Data Rate 2 | 3.0 Gbps | 3.0 Gbps | 3.0 Gbps |
| Routing Architecture | Table routing | Table routing | Table routing |
| Protocol Engine | SSP engine | SSP engine | SSP engine |
| Order Suffix | -02 | -01 | -03 |
Principaux différenciateurs
- Dense 18-PHY SAS expansion (vs VSC7155XVU-01)
- Dual documented SAS data-rate support (vs VSC7155XVU-03)
- Integrated SAS topology and protocol functions (vs VSC7155XVU-01)
Notes de conception
Treat every 1.5 Gbps and 3.0 Gbps SAS route as a controlled-impedance transmission line rather than a general-purpose digital trace. Follow the manufacturer reference layout for characteristic impedance, reference-plane continuity, via antipads, layer transitions, and connector launches. Avoid stubs and unnecessary test points, and keep the exact clocking, decoupling, and trace-routing topology from the reference design because the SSP engine and PHY timing depend on a controlled implementation.
Design the supply network around the exact maximum and typical current values listed for the production package in the manufacturer datasheet. Place decoupling capacitance at the device's power pins using the manufacturer's stability and layout guidance, and provide local bulk energy near the package without creating excessive loop area. Estimated: total dissipation equals the sum of each supply voltage multiplied by its measured or calculated current; this arithmetic must be checked against the worst-case data rate and PHY activity rather than the nominal 18-PHY count.
Check junction temperature using the package thermal model, board copper area, airflow, and the actual channel utilization. An 18-PHY design can consume more power as more links become active, so evaluate both nominal and maximum SAS activity. Estimated: junction temperature equals ambient temperature plus power dissipation multiplied by the effective board-and-package thermal resistance. Apply the manufacturer's recommended derating limits and avoid relying on a generic exposed-pad thermal value that does not match the exact package.
Do not approve a suffix change solely because the visible family name and headline PHY count match. Verify the exact package drawing, pin-description table, supply rails, clock requirements, reset behavior, qualification, and lifecycle status for VSC7155XVU-02 and every proposed substitute. Also avoid confusing this SAS expander with general-purpose I/O expanders or Serial ATA controllers; the table-routing and SSP-engine functions must remain equivalent for a drop-in decision.