Analog Devices

VSC7161XHK - 10-Port SAS Expander 1.5/3.0 Gbps | Analog Devices

Référence : VSC7161XHK ✓ Actif
TQFP-176 (XHK), surface mount Package
MOQ : 1 |

VSC7161XHK Présentation

The Analog Devices VSC7161XHK is a 10-port SAS expander that supports serial-attached SCSI link rates of 1.5 Gbps and 3.0 Gbps, packaged in a 176-lead TQFP (XHK) surface-mount package. It expands a single SAS host bus interface into ten external SAS ports for midrange and enterprise storage enclosures that require active port expansion rather than additional host adapters.

A SAS expander is a semiconductor switch that sits between a SAS host adapter (HBA) and one or more disk drives or expander-enclosed disks. It converts one narrow serial link into multiple independent serial links, allowing a storage enclosure to present more drives to the host than a single HBA port can address. In the SAS hierarchy, the VSC7161XHK belongs to the class of storage interface controllers and port expanders used inside rack-mounted storage subsystems.

Key characteristics include ten SAS ports operating at 1.5 Gbps and 3.0 Gbps, support for both SAS and SATA devices behind the expander, an evolutionary upgrade path for storage systems that later adopt 6 Gbps host adapters, and low-power operation suited to always-on storage appliances. The device also provides the enclosure management and fan-control support functions commonly expected in expander backplanes, reducing the component count of the backplane controller section.

Architecturally, the part implements a dedicated SAS link layer that handles 8b/10b encoding, clock recovery, disparity management, and packet-level framing across all ten ports. Port-to-port paths are handled in hardware rather than by an external microcontroller, so the expander can fan out traffic deterministically without firmware intervention on every path. Because the device is a fixed-function interface IC rather than a programmable controller, design-in effort is concentrated on backplane routing, connector pin assignment, and thermal budgeting rather than firmware development.

Typical deployments are midrange and enterprise direct-attached and network-attached storage enclosures, JBOD chassis, and SAS backplane carriers where drive count per controller must scale without adding HBA ports. It is equally suitable for drive enclosures requiring mixed SAS/SATA support and for server enclosure applications that need active port expansion instead of passive splitters.

One key design consideration is backplane signal integrity: with ten high-speed serial links on one board, differential pair routing, connector launch geometry, and reference-plane continuity control the achievable link margin more than any single IC specification. Keep the expander close to the connectors and keep the return path continuous through every layer change to limit skew and insertion loss.

This page consolidates manufacturer product information, ordering and availability references, drop-in and near-equivalent part relationships, and practical backplane-design guidance into a single engineering record that goes beyond the core product page.

Alternatives de remplacement direct pour VSC7161XHK — même boîtier, compatible broche à broche. Les références à boîtier différent nécessitant une retouche du PCB sont exclues.

Variantes de cette série

Modèles de la même série directement compatibles avec VSC7161XHK (même facteur de forme et même empreinte) — différant par Package, Product Type, Supported Data Rates.

Microchip Technology
Package: HT (BGA, high-temperature)
Product Type: SAS Edge/Fanout Expander
Supported Data Rates: 1.5 Gbps (G1), 3.0 Gbps (G2)
Comparer avec VSC7161XHK →
Analog Devices
Package: 132-pin LQFP
Product Type: SATA Port Selector / 2:1 Failover Multiplexer
Supported Data Rates: 1.5 Gbps (SATA Gen1) and 3.0 Gbps (SATA Gen2)
Comparer avec VSC7161XHK →

VSC7161

✅ Remplacement direct ⚠️ Spécifications non vérifiées
📦 TQFP-176 (XHK)
Base ordering code of the same expander silicon in the identical 176-lead TQFP footprint; no functional or parametric difference, XHK suffix only denotes the order configuration

📋 Alternative de référence (hors catalogue)

VSC7161XHK+T

✅ Remplacement direct ⚠️ Spécifications non vérifiées
📦 TQFP-176 (XHK)
Same die and same 176-lead TQFP footprint as VSC7161XHK; only the shipping format and ordering code differ (0% electrical difference)

📋 Alternative de référence (hors catalogue)

VSC7161XHK Spécifications

Device Type 10-port SAS expander
Number of SAS Ports 10 ports
Supported SAS Link Rates 1.5 Gbps and 3.0 Gbps
Package Type TQFP-176 (XHK), surface mount
Nombre de broches 176 leads
Protocol Support SAS (Serial Attached SCSI) and SATA device support
Primary Application Server and enclosure storage systems for midrange and enterprise storage
Fonction Active SAS port expansion for storage enclosures
Upgrade Path Evolutionary path to higher-rate SAS host adapters
AEC-Q100 Qualification Not applicable (storage interface IC, not automotive grade)
Standard Configuration 10-port SAS expander at 1.5 Gbps and 3.0 Gbps

Guide de configuration des broches du VSC7161XHK tqfp-176 (xhk), surface mount

Configuration des broches du VSC7161XHK (boîtier tqfp-176 (xhk), surface mount). La numérotation des broches, les fonctions et les schémas de connexion sont définis dans la fiche technique du fabricant. Consultez-la pour l'empreinte exacte et les directives de soudage.

Schéma de brochage du boîtier tqfp-176 (xhk), surface mount pour le VSC7161XHK

Aucune donnée de brochage détaillée disponible pour VSC7161XHK.

Consultez la fiche technique pour la configuration complète des broches.

Applications typiques

VSC7161XHK convient pour 6 applications: Enterprise Direct-Attached Storage Enclosure, JBOD Multi-Bay Drive Chassis, Mixed SAS/SATA Storage Backplane, Network-Attached Storage Controller Card, Video Surveillance Storage Array, Hyperscale Storage Enclosure Management.

🖥️

Enterprise Direct-Attached Storage Enclosure

The VSC7161XHK lets a single SAS host bus adapter reach drives across ten expander ports inside a rack storage chassis. With 10 SAS ports running at 1.5 Gbps or 3.0 Gbps, the enclosure can populate more bays without adding HBA ports to the server, and because the fan-out is handled in hardware the host sees a single deterministic topology. Support for both SAS and SATA devices also allows mixed-population enclosures to ship without a second controller board, which shortens qualification cycles for midrange and enterprise storage systems.

🏭

JBOD Multi-Bay Drive Chassis

In a JBOD configuration the VSC7161XHK is the natural fit because each enclosure exposes a defined set of drives to the host as one logical pool. Ten SAS ports per expander cover typical multi-bay chassis densities, and the 3.0 Gbps rate option preserves throughput as spindle and SSD populations increase. The trade-off is backplane complexity: differential routing must hold margin across the full connector-to-expander path, and enclosure management functions are usually assigned to a companion controller rather than handled inside the expander.

💾

Mixed SAS/SATA Storage Backplane

The VSC7161XHK supports SAS and SATA devices behind the same expander, which simplifies legacy-to-SSD migration in installed storage enclosures. A backplane can therefore retire SATA-only drive bays incrementally while new SAS capacity is added, without redesigning the host-side interface. The engineering caution is thermal and airflow: adding solid-state drives alongside spinning media changes the power profile of the enclosure, so the enclosure-management and fan-control functions must be validated against the real drive population rather than the worst-case datasheet number.

🌐

Network-Attached Storage Controller Card

In a NAS platform the VSC7161XHK can provide internal SAS expansion behind a network controller card, letting a single board present multiple disks to a network file system. Its 10-port, 1.5/3.0 Gbps capability suits the aggregated throughput of a multi-drive NAS enclosure while keeping the card area manageable because one expander replaces several discrete controllers. Designers should confirm the host-side interface and firmware expectations of their chosen NAS chipset, since the expander is a transparent path element and does not itself implement a file system.

🎥

Video Surveillance Storage Array

Surveillance arrays are write-heavy, always-on systems that benefit from the VSC7161XHK's ability to fan a single host link out to ten drive ports while supporting SATA devices common in this market. Consolidation of many drive streams behind one adapter reduces per-chassis host adapter count and simplifies rack cabling. The design constraint in this segment is sustained write throughput and vibration margin, so link rate selection should be matched to the encoder bitrate rather than to the headline 3.0 Gbps capability of the expander.

🏭

Hyperscale Storage Enclosure Management

Large-scale storage systems use expander-based enclosures to scale drive counts predictably, and the VSC7161XHK sits in that architectural tier by providing ten ports per device with an evolutionary upgrade path for future host-adapter speeds. This lets infrastructure designers standardise a backplane today while preserving a path to faster host links later. Because the part is a fixed-function interface IC, fleet-level management functions such as telemetry, predictive failure monitoring, and firmware policy are handled by the enclosure controller and management software rather than by the expander.

What is the VSC7161XHK?
The VSC7161XHK is a 10-port SAS expander from Analog Devices (Maxim heritage) that supports serial-attached SCSI link rates of 1.5 Gbps and 3.0 Gbps. According to the Analog Devices VSC7161 product page, the device provides active SAS port expansion for server and enclosure applications in midrange and enterprise storage systems, and it is offered in a 176-lead TQFP (XHK) surface-mount package.
How many SAS ports does the VSC7161XHK provide and at what speeds?
The VSC7161XHK provides 10 SAS ports, each operating at 1.5 Gbps or 3.0 Gbps. The Analog Devices product description states that the device supports 1.5 Gbps and 3.0 Gbps and is used for server and enclosure applications requiring active SAS port expansion. Per-port link rate, lane count, and internal PCIe-side details should be confirmed against the current manufacturer datasheet before layout sign-off.
What is the difference between a SAS expander and a SAS HBA?
A SAS expander is a hardware switch that fans one SAS link out to many device links, while a SAS host bus adapter (HBA) is the host-side controller that initiates and manages transactions. The VSC7161XHK performs the fan-out function, so a single host port can address drives across ten expander ports. Because the expander is a fixed-function interface IC rather than a programmable controller, firmware effort shifts to the HBA and enclosure controller.
Where can I download the VSC7161XHK datasheet PDF?
The manufacturer product page for the VSC7161 is the authoritative source for documentation, including the datasheet, ordering information, and pin description. Access the VSC7161 product page at analog.com and use the linked Data Sheet and Reference Documents sections. Third-party listings also reference the same device family; use the manufacturer document as the controlling revision for pin assignment and electrical limits.
Where can I find the VSC7161XHK pinout and package drawing?
The VSC7161XHK uses a 176-lead TQFP (XHK) package, and the pin description table in the manufacturer datasheet is the controlling source for numbering, ground assignments, and differential pair grouping. Because no publicly indexed 176-pin symbol matches the standard package-diagram library, use the datasheet pin-description table directly when assigning PCB tracks rather than relying on a generic outline drawing.
Is the VSC7161XHK still an active product?
Analog Devices lists the VSC7161 family as a current product for midrange and enterprise storage expansion, and the VSC7161XHK ordering code continues to be offered by authorized distributors and stocked by specialist suppliers. Lifecycle status for a specific ordering code, including any last-time-buy notices, should be confirmed against the current manufacturer product page before committing to a production schedule.
What is the best drop-in replacement for the VSC7161XHK?
The closest drop-in path is the base VSC7161 device in the same TQFP-176 package, since the XHK suffix denotes the package and ordering configuration of the same silicon. Because the VSC7161XHK is a highly integrated, application-specific SAS expander, few cross-brand parts are truly pin-for-pin interchangeable; the practical alternatives tend to be different expander architectures with different port counts, packages, and enclosure-management support.
Can I replace the VSC7161XHK with a different SAS expander without redesign?
Only in limited cases. A true drop-in requires the identical TQFP-176 footprint, the same 10-port configuration, the same 1.5 Gbps and 3.0 Gbps link rates, and matching enclosure-management and fan-control pin functions. The Infineon PSB2163T-V3.1 is frequently compared against the VSC7161XHK as a competing SAS expander, but it uses a different package and pinout, so it is a redesign-level substitution rather than a drop-in replacement.
VSC7161XHK vs PSB2163T-V3.1 - which is better for a storage enclosure?
The VSC7161XHK is preferred when the backplane is already laid out around a 176-lead TQFP footprint with ten 1.5/3.0 Gbps SAS ports, because it requires no board changes. The Infineon PSB2163T-V3.1 becomes attractive only when a full redesign is acceptable and its port count, enclosure features, and pricing better match the new enclosure. Neither part substitutes for the other on an unmodified PCB.
When should I choose the VSC7161XHK over a passive SAS splitter?
Choose the VSC7161XHK when the design requires more than a few drives per host port, needs SATA devices served behind the same backplane, needs enclosure management and fan-control support, or expects later migration to faster host adapters. A passive splitter offers no port expansion under load, no error handling, and no path to higher link rates, so it is only appropriate for small, fixed, low-bandwidth enclosures.
Is the VSC7161XHK suitable for JBOD and direct-attached storage designs?
Yes, the VSC7161XHK is aimed squarely at server and enclosure storage systems, including JBOD chassis where each enclosure presents a set of drives to a host adapter. Its 10-port configuration lets one enclosure hold a useful drive count behind a single host link, and the support for both SAS and SATA devices allows mixed-population enclosures without a second expander board.
What is the lead time for the VSC7161XHK?
Lead time for the VSC7161XHK varies with supplier inventory and date-code availability, and it is typically handled on a quote basis for this kind of interface IC. Use the Request a Quote form on this page to state your required quantity, target date code, and shipping destination so current allocation can be confirmed against your build schedule.
How do I get a price for the VSC7161XHK?
Pricing for the VSC7161XHK depends on volume, date code, and sourcing channel, and it is refreshed continuously rather than published statically. Submit the quantity and packaging requirements through the Request a Quote form on this page and the current price and availability will be returned against your specific schedule.
What are the key specifications of the VSC7161XHK that engineers should know?
The engineering-critical facts are: 10 SAS ports, link rates of 1.5 Gbps and 3.0 Gbps, a 176-lead TQFP (XHK) surface-mount package, and a target application in server and enclosure storage for midrange and enterprise systems. The device is an active expander with SAS and SATA device support and an evolutionary path toward faster host adapters; core supply voltage and power dissipation should be taken from the manufacturer datasheet.
What design considerations matter for the VSC7161XHK in a backplane?
Signal integrity on the ten differential SAS links dominates the layout. Match differential pair lengths within the connector launch region, provide a continuous reference plane across every layer transition, keep the expander close to the high-speed connectors, and pay attention to connector and via stub losses at 3.0 Gbps. Power and thermal design follow from the datasheet supply rails and dissipation figures.
What can replace the VSC7161XHK?
The most direct replacement path is the same VSC7161 silicon ordered under a different packaging or ordering suffix in the same TQFP-176 outline. Beyond that family, competing SAS expanders from Infineon and Broadcom exist, but they use different packages, port counts, and enclosure-management arrangements, so substituting them means a backplane redesign rather than a component swap.

Données de référence d'ingénierie pour VSC7161XHK — comparaison, recommandations de conception et informations de conformité.

Guide de sélection

Choose the VSC7161XHK when your backplane is already built around a 176-lead TQFP footprint and you need ten SAS ports at 1.5 or 3.0 Gbps with SAS and SATA device support, which is the common case for midrange and enterprise storage enclosures. The base VSC7161 ordering code and the VSC7161XHK+T variant carry the same silicon in the same package, so choose them purely on ordering-code availability and date-code needs. If your design targets a different package or a different port count, competing expanders such as the Infineon PSB2163T-V3.1 become candidates, but they are redesign-level substitutions with new pin assignments, enclosure-management mapping, and signal-integrity work. Choose a passive splitter only for small fixed enclosures with a handful of drives and no fault-reporting requirement.

Comparaison avec les alternatives

Paramètre Ce produit VSC7161 VSC7161XHK+T
Package TQFP-176 (XHK) TQFP-176 (XHK) TQFP-176 (XHK)
Brand Analog Devices Analog Devices Analog Devices
Device Type 10-port SAS expander 10-port SAS expander 10-port SAS expander
Number of SAS Ports 10 ports 10 ports 10 ports
Supported Link Rates 1.5 Gbps and 3.0 Gbps 1.5 Gbps and 3.0 Gbps 1.5 Gbps and 3.0 Gbps
Pin Count 176 leads 176 leads 176 leads
Device Support Behind Expander SAS and SATA SAS and SATA SAS and SATA
Target Application Midrange and enterprise server and enclosure storage Midrange and enterprise server and enclosure storage Midrange and enterprise server and enclosure storage

Principaux différenciateurs

  • Ten SAS ports per device in a single 176-lead TQFP (vs PSB2163T-V3.1)
  • Transparent, hardware-managed fan-out reduces host-side complexity (vs Passive SAS splitters)
  • Supports SAS and SATA devices behind the same expander (vs Enclosure designs requiring separate SAS and SATA controllers)

Notes de conception

Ten differential SAS links running to 3.0 Gbps make connector launch geometry and reference-plane continuity the dominant design variables. Route each differential pair as a tightly coupled pair over a continuous plane, keep length mismatch between pair members small, and avoid layer transitions that force a return-path discontinuity directly under the pair. Provide generous via stitching around the expander and connector region, and treat connector and via stub length as a matched component of the channel budget rather than as an afterthought.

Place the VSC7161XHK as close to the SAS connectors as the pin assignment allows, so that the longest traces in the channel belong to the connector and backplane structure rather than to the IC. Keep the expander's high-speed ball or lead exits away from noisy enclosure-management and fan-control switching nodes, and provide dedicated quiet return paths for the supply and ground pins adjacent to the serial links. Following the manufacturer reference layout for decoupling and pin assignment reduces risk in first-article builds.

Two mistakes recur in SAS expander designs. First, the expander is often treated as a transparent wire, but drive presence, fault, and activity signalling must be routed to an enclosure controller and to the host adapter through the correct management path; omitting those lines yields drives that enumerate but cannot be monitored. Second, mixed SAS and SATA populations change the enclosure power and thermal profile, so validate airflow and hot-swap behaviour against the final drive mix instead of a datasheet maximum.

Estimated: with ten links active at 3.0 Gbps, the serial link current is the dominant term, but the expander's own core supply and termination power determine the total rail current. Because the specific supply voltages and dissipation figures are not published on the product page, take the core and I/O rail requirements from the manufacturer datasheet before sizing the supply, and budget for the local decoupling network specified there. Confirm the regulator's transient response against the simultaneous link-training current step that occurs when all ten ports negotiate.

Informations de conformité

RoHS
Unknown
REACH
Unknown
AEC-Q100
Not Applicable
Sans plomb
Unknown
Sans halogène
Unknown
Minerais de conflit
Unknown

The manufacturer product page confirms the device function and ordering configuration but does not publish RoHS, REACH, or lead-free statements in the indexed content; confirm these on the current Analog Devices product page before release.

Données vérifiées le : 2026-11-05 — données vérifiées et sélectionnées par l'équipe d'ingénierie composants de XAIPART

Recherches associées

VSC7161XHK datasheet VSC7161XHK pinout VSC7161XHK price VSC7161XHK TQFP-176 VSC7161 10-port SAS expander VSC7161 vs PSB2163T-V3.1 VSC7161XHK replacement VSC7161XHK equivalent part VSC7161XHK storage enclosure application Analog Devices VSC7161XHK VSC7161 3.0 Gbps SAS expander VSC7161XHK schematic symbol

Composants & termes associés

Analog Devices Maxim Integrated VSC7161XHK VSC7161 SAS expander Serial Attached SCSI SATA storage interface controller port expander semiconductor TQFP-176 surface mount package 1.5 Gbps 3.0 Gbps 10-port SAS JBOD enterprise storage enclosure enclosure management differential pair signal integrity host bus adapter backplane
RFQ de devis rapide
Renseignez tous les détails — notre équipe commerciale vous répondra sous 24 heures
Référence Fabricant Boîtier QTY Prix cible Total
✓
Devis envoyé !

Nous répondrons à votre e-mail sous 24 heures

1
RFQ envoyée
2
Devis reçu
3
Commande passée
4
Paiement
5
Expédié
6
Livré
Voir les détails de la RFQ