AD7712AR - 24-Bit Dual-Channel Sigma-Delta ADC | Analog Devices
MPN: AD7712AR ✓ פעילAD7712AR סקירה
A sigma-delta ADC is a type of analog-to-digital converter that uses oversampling, digital filtering, and noise shaping to obtain high resolution at relatively low sample rates. The AD7712 belongs to the broader hierarchy of signal-chain IC, data-converter IC, ADC/DAC, and analog-to-digital converter categories. It is particularly suited to sensors and instrumentation where the wanted signal changes slowly compared with the converter's internal sampling rate.
The AD7712's headline specifications are 24-bit resolution, two analog input channels, and operation in a 24-SOIC package. According to the Analog Devices AD7712 datasheet, the device uses a sigma-delta conversion technique to achieve up to 24 bits of no-missing-codes performance. Its differential-input capability and software-configurable channel selection, gain, and signal polarity support flexible sensor measurement and microcontroller-based system designs.
The converter produces a serial digital word through a configurable bidirectional serial interface. Input channel selection, gain settings, and polarity can therefore be controlled by firmware rather than fixed in hardware. This programmability makes the ADC useful in multichannel measurement systems where several transducers share one precision analog front end. The manufacturer identifies the AD7712 as suitable for smart, microcontroller-based systems and for low-level inputs connected directly to transducers.
Typical applications include pressure and temperature measurement, bridge-based sensor instrumentation, process-control monitoring, portable data acquisition, and industrial diagnostic equipment. The AD7712AR can also accept higher-level signals up to ±4 × VREF when the transducer does not require the low-level input range. Its sigma-delta architecture favors slowly varying signals and high-resolution measurements rather than high-bandwidth waveform acquisition.
When designing the circuit, provide the analog and reference paths with short, shielded or guarded traces, place bypass capacitors close to the supply and reference pins, and keep switching-converter routing away from the sensitive input nodes. Select external resistor and capacitor values using the Analog Devices AD7712 datasheet's recommended application circuit and calibration guidance. System clocking and serial-interface timing must also meet the electrical characteristics specified for the selected operating mode.
This product resource combines manufacturer specifications, package and pin-assignment guidance, interface design considerations, application fit, and a clear assessment of compatible alternatives. It is designed to help engineers move from device selection to a defensible low-frequency measurement design while recognizing where an exact drop-in substitute has or has not been established.
חלופות תחליף ישיר עבור AD7712AR — אותו מארז, תואם פין-לפין. חלקים במארז שונה הדורשים עיבוד מחדש של ה-PCB אינם נכללים.
וריאנטים בסדרה זו
דגמים מאותה סדרה התואמים Drop-in עם AD7712AR (אותו גורם צורה וטביעת רגל) — שונים ב Resolution.
AD7712ARZ
✅ Drop-In📋 חלופה להתייחסות (לא בקטלוג)
AD7712AR דירוגים מרביים ומאפיינים חשמליים
| Converter Type | Sigma-delta ADC |
| רזולוציה | 24 bits |
| No Missing Codes | Up to 24 bits |
| Analog Input Channels | 2 channels |
| Input Architecture | Differential input |
| Low-Level Input Support | Direct transducer input |
| High-Level Input Span | ±4 × VREF |
| Maximum Sample Rate | 1.028 kSPS |
| Output Format | Serial digital word |
| Serial Port | Bidirectional, software-configurable |
| Configurable Parameters | Input channel, gain, and signal polarity |
| Process Technology | Production CMOS |
| מארז | 24-pin SOIC |
| סוג הרכבה | Surface mount |
מדריך תצורת פינים של AD7712AR 24-pin soic
תצורת פינים עבור AD7712AR (מארזת 24-pin soic). רכיב אנלוגי זה כולל פיני כניסה, יציאה ואספקת מתח. יש לעיין בגיליון הנתונים של היצרן לתצורות פיני איפוס היסט, פיצוי והפעלה. אידיאלי למעגלי עיצוב אותות ומגברים.
אין נתוני פריסת פינים מפורטים עבור AD7712AR.
עיינו ב- גיליון נתונים עבור תצורת פינים מלאה.
יישומים טיפוסיים
AD7712AR מתאים עבור 6 יישוםs: Pressure Sensor Instrumentation, Temperature Measurement, Industrial Process Monitoring, Portable Data Acquisition, Load Cell Measurement, Laboratory Sensor Interface.
Pressure Sensor Instrumentation
The AD7712AR suits slow-changing pressure and other resistive-bridge signals because it combines 24-bit sigma-delta conversion with differential inputs and programmable gain. Two analog channels allow closely related bridge outputs to be measured without changing the converter architecture. The 1.028 kSPS maximum sample rate is appropriate for many static or slowly varying pressure systems. Place the sensor return at the differential input, provide the specified excitation and reference circuitry, and use the manufacturer calibration sequence to remove offset and gain errors. Differential routing also helps reject common-mode voltage present on long sensor wiring.
מומלץ
Temperature Measurement
The AD7712AR is appropriate for resistance-based temperature sensors and low-level temperature signals that change more slowly than the converter's 1.028 kSPS conversion capability. Its 24-bit resolution can preserve small sensor changes, while two channels can support redundant sensing or a reference comparison. Use the differential input structure to connect the sensor network, and apply the input-filter and reference arrangements specified in the Analog Devices AD7712 datasheet. Firmware can select the channel, gain, and polarity through the serial interface, reducing the need for analog switches close to the sensor.
מומלץ
Industrial Process Monitoring
The AD7712AR fits process-monitoring loops where variables such as level, pressure, or temperature vary slowly and require more resolution than a conventional low-cost ADC. Its two analog input channels, differential measurement capability, and programmable signal conditioning allow a single device to monitor two related inputs. The serial interface supports software-controlled operating modes, which is useful for periodic sampling and calibration in industrial equipment. Keep the analog section away from switching supplies and motor-control traces, and validate the converter's digital filter settling time against the required measurement rate.
מומלץ
Portable Data Acquisition
The AD7712AR can form the precision measurement section of a portable or compact data-acquisition system that records low-frequency sensor data. Its 24-bit output supports detailed measurements without requiring a high-speed ADC, and its two input channels help reduce analog-front-end complexity. A microcontroller can configure channel selection, gain, polarity, and conversion timing through the bidirectional serial port. Because sigma-delta conversion requires digital filtering and settling, design the acquisition cycle around the selected data rate and filter mode rather than treating every filter output as an instantaneous sample.
מומלץ
Load Cell Measurement
The AD7712AR is appropriate for load-cell and weighing systems where the bridge output is small, changes slowly, and benefits from differential measurement. The converter's low-level transducer input support avoids placing a separate low-noise analog amplifier ahead of the ADC when the application does not require one. Programmable gain and polarity allow firmware to handle excitation-induced offsets and signal direction. Use shielded sensor wiring, a quiet reference, and the input-filter network shown in the manufacturer application circuit. Calibration should be performed at the intended excitation level because gain and offset errors depend on the complete analog path.
מומלץ
Laboratory Sensor Interface
The AD7712AR is useful in laboratory instruments that acquire slow sensor outputs while requiring high resolution and programmable signal conditioning. Two analog channels can be assigned to separate transducers, and the software-configurable serial interface enables calibration tables, filtering, and gain control under host command. The 1.028 kSPS maximum rate suits temperature, force, displacement, and laboratory pressure measurements more closely than audio or waveform acquisition. For bench equipment, provide a stable reference source, shielded analog routing, and sufficient settling time for the configured digital filter.
מומלץ
סיכום מוצרים מומלצים
נתוני עזר הנדסיים עבור AD7712AR — השוואה, הנחיות תכנון ומידע על תאימות.
מדריך בחירה
השוואה עם חלופות
| פרמטר | מוצר זה | AD7712ARZ |
|---|---|---|
| Package | 24-SOIC | 24-SOIC |
| Brand | Analog Devices | Analog Devices |
| Converter Type | Sigma-delta ADC | Sigma-delta ADC |
| Resolution | 24 bits | 24 bits |
| Analog Input Channels | 2 channels | 2 channels |
| Maximum Sample Rate | 1.028 kSPS | 1.028 kSPS |
| Input Capability | Low-level transducer input or up to ±4 × VREF | Low-level transducer input or up to ±4 × VREF |
| Interface Configuration | Bidirectional serial port with configurable channel, gain, and polarity | Bidirectional serial port with configurable channel, gain, and polarity |
מבדילים עיקריים
- Two-channel precision measurement in one converter (לעומתAD7712ARZ)
- Full 24-bit conversion capability (לעומתAD7712ARZ)
- Low-frequency signal conditioning integrated into the ADC (לעומתAD7712ARZ)
הערות תכנון
Route the differential input and reference paths as short, quiet nets, and keep switching-regulator, clock, and digital return currents away from high-impedance analog nodes. Use a continuous ground reference beneath the analog section where the board design permits. When the sensor is connected through a cable, use twisted differential wiring and grounded shielding to prevent environmental pickup from corrupting the low-level input.
Do not configure the converter as though it were a high-speed, instantaneous-sampling ADC. Sigma-delta outputs emerge after the selected digital filter settles, so the conversion cycle, channel-switching delay, and calibration routine must be sequenced correctly. Review the mode-dependent data rates and settling requirements in the AD7712 datasheet before establishing the acquisition timing used by the host controller.
Place the required bypass capacitors directly beside the supply and reference pins, and provide a clean reference source with the decoupling recommended by Analog Devices. Verify the analog and digital supply voltages, common-mode range, and reference limits from the current datasheet before connecting external circuitry. Separating noisy supply conversion from the analog section reduces the chance that ripple will dominate the 24-bit measurement resolution.
מידע על תאימות
The product description identifies the AD7712 as production CMOS but does not provide explicit RoHS, REACH, AEC-Q100, lead-free, halogen-free, or conflict-minerals declarations. Confirm current material compliance using Analog Devices product documentation and the selected ordering code.