A sampling ADC is a data-conversion IC that acquires an analog voltage, samples it during a defined acquisition interval, and converts that sample into a digital value. The AD7870 belongs to the broader hierarchy of analog-to-digital converter, data-converter IC, and semiconductor. Its sampling architecture is suited to instrumentation, industrial measurement, control, and signal-acquisition systems that require deterministic conversion timing without an external clock circuit.
Key characteristics include 12-bit resolution, a 100 kHz sampling rate, an 8 µs successive-approximation conversion time, and a 2 µs track-and-hold acquisition interval. The manufacturer also specifies 72 dB signal-to-noise ratio at a 10 kHz input frequency and 57 ns data-access time. The integrated 3 V buried-Zener reference and laser-trimmed clock reduce external timing-component requirements and support repeatable acquisition in multi-channel measurement systems.
The AD7870CQ uses a successive-approximation conversion architecture, balancing conversion speed with a complete integrated acquisition and reference subsystem. Parallel, byte, and serial output choices allow the converter to connect to microprocessors, digital signal processors, programmable logic, counters, and embedded control systems. The internal clock can be used when the application does not require an external sampling clock, while its interface flexibility supports both legacy parallel buses and serial data acquisition systems.
Typical applications include industrial process-control loops, instrumentation and test systems, multichannel data acquisition, digital voltmeter and measurement equipment, and embedded sensor interfaces. In each case, the 100 kHz conversion rate supports periodic measurements while the 12-bit word length provides 4096 digital code levels. The 2 µs acquisition interval must be considered when the source impedance, sample-and-hold capacitor, and input-network settling time are selected.
For reliable implementation, place the input, reference, and interface bypass capacitors close to their associated pins, maintain the analog and digital return-current paths separately, and verify acquisition settling with the complete source network. The interface mode and timing should be selected from the manufacturer pin-description table and data sheet before assigning PCB signals.
This page combines the manufacturer product information, distributor identification of the 24-CDIP variant, structured interface guidance, practical application analysis, and engineering-oriented replacement considerations. It also identifies which electrical, environmental, and lifecycle attributes require confirmation from the current Analog Devices documentation.
חלופות תחליף ישיר עבור AD7870CQ — אותו מארז, תואם פין-לפין. חלקים במארז שונה הדורשים עיבוד מחדש של ה-PCB אינם נכללים.
וריאנטים בסדרה זו
דגמים מאותה סדרה התואמים Drop-in עם AD7870CQ (אותו גורם צורה וטביעת רגל) — שונים ב Package, Converter Type, Internal Reference, Internal Clock, Track-and-Hold Amplifier.
AD7870
✅ Drop-In ⚠️ מפרטים לא מאומתים📋 חלופה להתייחסות (לא בקטלוג)
AD7870A
✅ Drop-In ⚠️ מפרטים לא מאומתים📋 חלופה להתייחסות (לא בקטלוג)
AD7870CN
✅ Drop-In ⚠️ מפרטים לא מאומתים📋 חלופה להתייחסות (לא בקטלוג)
AD7870CP
✅ Drop-In ⚠️ מפרטים לא מאומתים📋 חלופה להתייחסות (לא בקטלוג)
AD7870AQ
✅ Drop-In ⚠️ מפרטים לא מאומתיםצור קשר לקבלת מחיר
הצג גיליון נתונים ←AD7870CQ דירוגים מרביים ומאפיינים חשמליים
| Converter Type | 12-bit successive-approximation sampling ADC |
| רזולוציה | 12 bit |
| קצב דגימה | 100 kHz |
| Conversion Time | 8 µs |
| Track-and-Hold Acquisition Time | 2 µs |
| Number of Inputs | 1 input |
| Architecture | Successive approximation |
| Input Type | Single-ended unipolar input |
| Internal Reference | 3 V buried-Zener reference |
| Clock | Laser-trimmed internal clock |
| Signal-to-Noise Ratio | 72 dB at 10 kHz input frequency |
| Data Access Time | 57 ns |
| Digital Interface | Parallel, byte-oriented, and serial |
| מארז | 24-pin ceramic dual-in-line package |
| Lead Pitch | 0.3 inch |
| סוג הרכבה | Through-hole |
מדריך תצורת פינים של AD7870CQ 24-pin ceramic dual-in-line package
תצורת פינים עבור AD7870CQ (מארזת 24-pin ceramic dual-in-line package). רכיב אנלוגי זה כולל פיני כניסה, יציאה ואספקת מתח. יש לעיין בגיליון הנתונים של היצרן לתצורות פיני איפוס היסט, פיצוי והפעלה. אידיאלי למעגלי עיצוב אותות ומגברים.
אין נתוני פריסת פינים מפורטים עבור AD7870CQ.
עיינו ב- גיליון נתונים עבור תצורת פינים מלאה.
יישומים טיפוסיים
AD7870CQ מתאים עבור 6 יישוםs: Industrial Process Measurement, Data Acquisition Systems, Digital Test and Measurement, Embedded Sensor Conditioning, Audio and Vibration Analysis, Embedded Control and Monitoring.
Industrial Process Measurement
The AD7870CQ is appropriate for periodic process-variable acquisition because it combines 12-bit resolution with a 100 kHz sampling rate. Its 2 µs track-and-hold interval and 8 µs successive-approximation conversion stage fit transducers with established output networks, while the integrated 3 V buried-Zener reference reduces external reference complexity. The 24-CDIP package also suits legacy industrial controller boards with through-hole connector and isolation arrangements. Engineers should verify source settling, power-supply limits, and the operating-temperature grade before deployment.
מומלץ
Data Acquisition Systems
The AD7870CQ provides a compact acquisition front end for multichannel measurement systems because the track-and-hold amplifier, converter, reference, clock, and output logic are integrated in one 24-pin ceramic DIP. Its 100 kHz sampling capability supports repeated scans, while parallel, byte-oriented, and serial interfaces permit connection to different processor architectures. For multiplexed systems, the available acquisition interval, input-driver settling, and switching-transient margin require validation across the complete signal chain.
מומלץ
Digital Test and Measurement
For digital voltmeters, calibrators, and automated test equipment, the AD7870CQ offers 4,096 code levels from a 12-bit converter and a specified 72 dB SNR at 10 kHz input frequency. The 57 ns data-access time supports rapid transfer of conversion results to a controller, and the 100 kHz conversion rate allows repeated measurements without a complex external timing chain. Accuracy at the analog front end must still be established through reference layout, input filtering, calibration, and careful grounding.
מומלץ
Embedded Sensor Conditioning
The AD7870CQ can digitize conditioned outputs from resistive, temperature, pressure, and position sensors when the selected range matches the converter’s analog input specifications. Its integrated track-and-hold amplifier accepts a sampled voltage, and the internal 3 V buried-Zener reference supports a self-contained measurement chain. The 2 µs acquisition interval is important for high-impedance sources because the sampling network must charge fully before each 8 µs conversion begins. Use short signal paths and verify settling rather than assuming nominal acquisition time alone is sufficient.
מומלץ
Audio and Vibration Analysis
The AD7870CQ is applicable to controlled audio, vibration, and waveform-acquisition paths requiring 12-bit digital samples at up to 100 kHz. The successive-approximation architecture provides a defined 8 µs conversion interval, and the 2 µs acquisition period allows the track-and-hold stage to capture successive waveform points. The 72 dB SNR figure applies at a 10 kHz input frequency, so system-level signal-to-noise performance will also depend on anti-alias filtering, excitation level, grounding, and clock-interface implementation.
מומלץ
Embedded Control and Monitoring
The AD7870CQ fits embedded monitoring blocks that periodically measure an analog process variable and transfer the result to a microprocessor, DSP, or counter. The internal laser-trimmed clock removes external clock-timing components, while selectable parallel, byte, and serial outputs accommodate different bus widths. The 100 kHz maximum rate provides ample timing margin for supervisory control loops. Firmware must respect conversion completion, data-access timing, and interface-mode selection, and the PCB should isolate analog return currents from switching digital paths.
מומלץ
סיכום מוצרים מומלצים
נתוני עזר הנדסיים עבור AD7870CQ — השוואה, הנחיות תכנון ומידע על תאימות.
מדריך בחירה
השוואה עם חלופות
| פרמטר | מוצר זה | AD7870 | AD7870A | AD7870CN | AD7870CP | AD7870AQ |
|---|---|---|---|---|---|---|
| Brand | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices | Analog Devices |
| Package | 24-CDIP | 24-CDIP | 24-CDIP | 24-CDIP | 24-CDIP | 24-CDIP |
| Converter Type | Successive-approximation sampling ADC | Successive-approximation sampling ADC | Successive-approximation sampling ADC | Successive-approximation sampling ADC | Successive-approximation sampling ADC | Successive-approximation sampling ADC |
| Resolution | 12 bit | 12 bit | 12 bit | 12 bit | 12 bit | 12 bit |
| Sampling Rate | 100 kHz | 100 kHz | 100 kHz | 100 kHz | 100 kHz | 100 kHz |
| Conversion Time | 8 µs | 8 µs | 8 µs | 8 µs | 8 µs | 8 µs |
| Acquisition Time | 2 µs | 2 µs | 2 µs | 2 µs | 2 µs | 2 µs |
| Signal-to-Noise Ratio | 72 dB at 10 kHz | 72 dB at 10 kHz | 72 dB at 10 kHz | 72 dB at 10 kHz | 72 dB at 10 kHz | 72 dB at 10 kHz |
| Internal Reference | 3 V buried-Zener reference | 3 V buried-Zener reference | 3 V buried-Zener reference | 3 V buried-Zener reference | 3 V buried-Zener reference | 3 V buried-Zener reference |
| Digital Interface | Parallel, byte-oriented, and serial | Parallel, byte-oriented, and serial | Parallel, byte-oriented, and serial | Parallel, byte-oriented, and serial | Parallel, byte-oriented, and serial | Parallel, byte-oriented, and serial |
מבדילים עיקריים
- Complete integrated acquisition front end (לעומתAD7870)
- Flexible output architecture (לעומתAD7870A)
- Legacy-compatible ceramic DIP construction (לעומתAD7870CN)
הערות תכנון
Do not treat the 2 µs acquisition time as sufficient by itself for every source. The track-and-hold capacitor must charge from the chosen input impedance, amplifier output resistance, and external network within the available acquisition interval. Verify the complete settling curve at the lowest intended sampling rate and add acquisition time or a lower-impedance driver when the source cannot charge the internal sampling capacitor reliably.
Route the analog input directly to the converter and keep the track-and-hold signal path short. Place input and reference bypass components close to the relevant pins, maintain a continuous analog ground reference, and prevent digital output return currents from crossing the sensitive input area. The internal reference and clock reduce external components, but they do not remove the need for careful decoupling and return-path control.
Select the digital interface mode before laying out the PCB because parallel, byte-oriented, and serial operation can assign different signals to the same package leads. Check the manufacturer timing table for conversion completion and 57 ns data-access timing, then add adequate hold time at the receiving device. Unused outputs and configurable interface pins should be terminated according to the device guidance rather than left to float.
מידע על תאימות
The AD7870CQ is an industrial and instrumentation sampling ADC rather than an automotive-qualified AEC-Q100 device. No explicit RoHS, REACH, lead-free, halogen-free, or conflict-minerals declaration was established from the cited product information.